Download as pdf
Download as pdf
You are on page 1of 2
Model T6100 Lock Features i. * Locks in“Last Position” to 4 accurately capture setpoint * Etremely low drift after power loss. permits transaucer 10 maintain set point © IPAS Rating tn handle moist applications * Single part number makes it easy to specify and cover all your needs * Superior Construction including a mois ture rocictant PCB an ‘components. Operating Principles Uniquely the T6100 “Lock in Last Place” feature now provides flexibilty reliabilty and safety in applications requiring protection from signal falures to ertical contra system instru- ments, Design of the T6100 relies on a proprietary integrated sulenokl valve module inferpoeed between the fapper-nazzle pilot and the bbosttor eection. Upsn signal fallure, an clos trical charge stored within the active electronic 2 citeult controlling the integrated solenoid valve ‘module maintains the current to the voice coll at ts last setpoint. Simultaneously, 2 high energy pulse closes the solenoid valve, | trapping the signal pressure within the sig- 9. rial chamber at the last setpoint, Ine booster continues to provide its normal forward and ‘exhaust Now, wilh Ue costal igi pressure - - now captured and maintained within the signal chamber, The elertronie civil antivates the calennid valve immediately upon detection of a signal that falls below a base value of 35mA. Upon restoration of the signal, the electron cir- cult sends a high energy pulse to open the solenoid valve, restoring the pilot section's pressure control of the signal pressure to ‘ie booster as in a typical wanscucer_ine electronic detection circuit, in series with the T0100'> signal voritioiny civil, merely adds an additional voltage drop to the T6100's noma corr ioop, Aavanced valve tice LI design ofthe T6100 increases ts forward flow zal capacity to a minimum of 5-scfm at 21-psig + cay irecwe ee 800-334-8422 iS FAIRCHILD www.fairchildproducts.com Mode! T6100 Model T6100 Lock In Place Electro-Pheum: i Technical Specifications: output psig a5 aanwe ant nm ues} (a00) ‘suv ot a Pressure! (AR (i524) KPa} dst) Mini i 5 Span ean} 033) fe ‘s) Impedance 4-20mA vo ‘Ar Consumption 39 cant tperisasst.t) sorH Independent Linearty 05% (perisassi.t Hysteresis & Repeatability 025K FS ors 50 1) ‘Supply Pressure Effect on Output abot iP OAT (Phy re 2 poi [1.7 CARY, (1704 ty hanes Fon Rate crm (G5 mn 2 pg [1.7 BAR (1704Pa) Sup 89 psig, OG BAR) (@iPa) ouput RFL/EMI Effect {ess han 05% f Span @ 30 Yn ass 3 Band ABC cnt000 mi) pr SeuEnu-ss rosieane as nash Span Gu emire dau ‘the Bord pe IEG Sandard 60-3 64 EMC Drecve O2S5EEC Exropean Noms EN 5000-2 and EN SO0E22 ‘Temperature Range (per ISA $51.1) -20F to +150, (3010 to 485°C) Materials of Construction Randy and Hruicing Sharir Trim Zine Plated Stee! Diaphragm. Nite Ort Nickel Plated Brass: Weight 1000 grams Mounting |, Burface Mounting, oF 2” pipe mount bia avaliable ‘Mounting Postion ..... Verical Preferred: Other positions re-zero Dearee of Protection IP 65 Ratina Failure Mode - Output Pressure locks at last value when signal flis Drift Rate 2% per hour Maximum Etectical Connection ‘33mm square DIN 43650 connector tirantahle infor eects 7, FAIRCHILD ic UP Transducer Ordering Information Catalog No.: TL stoo CP) Elecical Connection HESNT Condut Feng DIN 43650 Connection Son ex Inout 420mA (8, TVokropmasmim e207) ‘Ouyput S15 pag oF 02-1.0 BAR 1" 20100 KPa a opt BSPT Thread” uv * Special Ranges Avalable Upon Request * Qtanndard Peumatic Comections ave 1/4" NPT Installation For mstatiation instructions, rerer to ine Feairentia moder ToTUy Lock In Place Electro-Pneumatic IP. Transducer Installation, [Uperation ana maintenance insiructons, 15-IUULUB UU, 800-334-8422 www fairchildproducts.com

You might also like