SCT/DAICEC/JC-1.

901
DAICEC JOB CARD APPLICATION OF WATER BASE ENAMEL PAINT Rev. No. 00
Page 01 of 02

Sector & Zone: C,D L 03, ZONE C,D C09,C10,D07,D10 Date of Inspection: 6/15/2019

Grid and level : L 03 Time of Inspection:


Measurement Remarks/
CODE SURFACE PREPARATION Importance Tolerance/ Requirements
SIL SCT Comments

1.901.2.1 Accessibility : Safe access to area visually (Evaluate and write 1 to 5) 2 Safe Access

1.901.2.2 Safety: Adequate Safety precautions being taken (Evaluate and Write 1 to 5) 3 comply safety requirement

1.901.2.3 Lighting : Provision of ambient task lighting facility (evaluate 0 or 1) 3 Non-Critical lighting

No dust, no mortar drops, no


1.901.2.4 Standard clearance : Dry surface clearance to be obtained. (Evaluate and write 1 to 5) 2
contamination,

remove loose particles,


Surface Preparation :- Sand the surface with emery paper no. 180, gradual grind and wipe
1.901.2.5 2 paint, dust, cracked & flaked
clean. (Evaluate and write 1 to 5)
paint

1.901.2.6 Moisture content : Check for Moisture content of substrate (Record moisture content in %) 3 Max. 15%

SIL Samsung C&T

Construction Representative QA/QC Engineer Construction Representative QA/QC Engineer


CODE Application of ICI Water Based Cement Primer.

ratio of 1:0.5 with graduated


1.901.3.1 Mixing : Mix ICI water based cement primer with water (write 0 or 1) 2
measuring jar

1.901.3.2 Consistency : Stir with spindle mechanically for homogeneity (evaluate and write 1 to 5) 2 Consistent homogeneity

Shall be applied uniformly


1.901.3.3 Application : Apply ICI water based cement primer uniformly (evaluate and write 1 to 5) 3 and coverage 120-150
sqft/litre

as per TDS : Overnight


1.901.3.4 Drying time : Check for drying time (Write 0 for non confirming and 1 for confirming) 2
drying time

SIL Samsung C&T

Construction Representative QA/QC Engineer Construction Representative QA/QC Engineer


CODE Application of First Coat of ICI Acrylic Wall Putty

Surface preparation: Smoothen the surface by filling dents with ICI Acrylic wall putty up Sand with emery paper 180
1.901.3.5 2
to maximum thickness of 3-4 mm . (write 0 or 1) if irregularities are observed

1.901.3.6 Application : Apply ICI acrylic wall putty on surface (evaluate and write 1 to 5) 2 With Putty blade uniformly

Coverage 20 sqft/kg sample


1.901.3.7 Coverage : Weigh the mix using weighing machine. (Write 0 or 1) 3
it for 1 sqm area

Min : 4-6 hours - As per


1.901.3.8 Drying time : Check for drying time (Write 0 or 1) 2
TDS

SIL Samsung C&T

Construction Representative QA/QC Engineer Construction Representative QA/QC Engineer


CODE Application of Second Coat of ICI Acrylic Wall Putty

Surface preparation: Sand the surface with emery paper 180 and wipe clean. (Write 0 or Uniform surface shall be
1.901.3.9 2
1) achieved

1.901.3.10 Application : Apply ICI acrylic wall putty on surface (evaluate and write 1 to 5) 2 With Putty blade uniformly

Coverage 20 sqft/kg sample


1.901.3.11 Coverage : Weigh the mix using weighing machine. (Write 0 or 1) 3
it for 1 sqm area

Min : 4-6 hours - As per


1.901.3.12 Drying time : Check for drying time (Write 0 or 1) 2
TDS

SIL Samsung C&T

Construction Representative QA/QC Engineer Construction Representative QA/QC Engineer


SCT/DAICEC/JC-1.901
DAICEC JOB CARD APPLICATION OF WATER BASE ENAMEL PAINT Rev. No. 00
Page 01 of 02

Sector & Zone: C,D L 03, ZONE C,D C09,C10,D07,D10 Date of Inspection: 6/15/2019

Grid and level : L 03 Time of Inspection:


Measurement Remarks/
CODE Application of ICI Water Based Cement Primer Importance Tolerance/ Requirements
SIL SCT Comments

Surface preparation: Sand the surface with emery paper 180 and wipe clean. (Write 0 or Uniform surface shall be
1.901.3.13 2
1) achieved

ratio of 1:0.5 with graduated


1.901.3.14 Mixing : Mix ICI water based cement primer with water (Write 0 or 1) 2
measuring jar

1.901.3.15 Consistency : Stir with spindle mechanically (evaluate and write 1 to 5) 2 Consistent homogeneity

Shall be applied uniformly


1.901.3.16 Application : Apply ICI water based cement primer (evaluate and write 1 to 5) 3 and coverage 120-150
sqft/litre

Overnight drying time as per


1.901.3.17 Drying time : Check for drying time (Write 0 or 1) 2
TDS

SIL Samsung C&T

Construction Representative QA/QC Engineer Construction Representative QA/QC Engineer


CODE Application of first coat of Dulux Satin stay bright (Colour : SPL OC 65)

Surface preparation: Sand the surface with emery paper 380 and wipe clean. (Write 0 or Uniform surface shall be
1.901.3.18 2
1) achieved

Mixing : Mix Dulux Satin stay bright (SPL OC 65) with water and stir with spindle In ratio of 1:0.25
1.901.3.19 2
mechanically (Write 0 or 1) (Emulsion : Water)

Application : Apply Dulux Satin stay bright (Colour : SPL OC 65) (evaluate and write 1 to Uniform Coverage 100-120
1.901.3.20 3
5) sqft/ half litre

1.901.3.21 Drying time : Check for drying time (Write 0 or 1) 2 Min 6 hours as per TDS

SIL Samsung C&T

Construction Representative QA/QC Engineer Construction Representative QA/QC Engineer


CODE Application of Second Coat of Dulux Satin stay bright (Colour : SPL OC 65)
Uniform and levelled
Surface preparation: Sand the surface with emery paper 380 and wipe clean. (Write 0 or
1.901.3.22 2 surface free from any visual
1)
defects

Mixing : Mix Dulux Satin stay bright (SPL OC 65) with water and stir with spindle In ratio of 1:0.25
1.901.3.23 2
mechanically (Write 0 or 1) (Emulsion : Water)

Application : Apply Dulux Satin stay bright (Colour : SPL OC 65) (evaluate and write 1 to Coverage 100-120
1.901.3.24 3
5) sqft/ half litre

1.901.3.25 Drying time : Check for drying time (Write 0 or 1) 2 Min 6 hours as per TDS

1.901.3.26 Post two coats of Dulux Satin stay bright (Colour : SPL OC 65)

Final Finish : undulations shall be minimised and shall match to mock up (Evaluate and
1.901.3.27 3 match to SPL OC 65
write 1 to 5)

Uniformity of shade : Check colour shade comparing with approved sample in provided
1.901.3.28 3 no change in shade
lighting. (Evaluate and write 1 to 5)

Joint marks : Check for joint mark between adjacent coated area in provided lighting.
1.901.3.29 3 no joint mark
(Evaluate and write 1 to 5)

Overall workmanship

No Objection by the Samsung C&T's Representative shall not relieve SIL of its obligation to complete all the work in accordance with Contract Documents.

Action date to be mentioned for rectification of the defects in the Painting -

Comments:

SIL Samsung C&T

Construction Representative QA/QC Engineer Construction Representative QA/QC Engineer

You might also like