FLEXIBILITY

Master MPS is suitable for a wide range


of applications including IT and the most
demanding industrial environments.
The UPS is suitable for power capacitive
loads such as blade servers, from 0.9
leading to 0.8 lagging. With a broad range
of accessories and options, complex
configurations and system architectures
can be achieved to guarantee maximum
power availability and the option to add
new UPS without interruption to existing
installation.

BATTERY CARE SYSTEM:


MAXIMUM BATTERY CARE
Normally the batteries are kept charged
by the rectifier; when mains power fails,
Detail of connection area
the UPS uses this energy source to
power the consumers. Proper battery
care is therefore critical to ensuring
correct UPS operation under emergency • Graphic display panel for remote OPTIONS
conditions. The Riello UPS battery care connection. • UPS Group Synchroniser (UGS)
system consists of a series of functions Allows two or more non-parallel UPS
designed to optimise battery management MAXIMUM RELIABILITY AND devices to remain synchronised even
and achieve the best performance and AVAILABILITY during mains power failure.
operating life possible. • Distributed or centralised parallel The UGS also enables a Riello UPS to be
Master MPS is also compatible with configuration of up to 8 units redundant synchronised with another power source
different battery technologies: vented (N+1) or power parallel system. Parallel that is independent and of a different
open lead acid, VRLA AGM, Gel, NiCd, configurations using models with power rating.
Flywheels, Supercaps and Lithium. different power ratings are also possible;
• Hot System Expansion (HSE): allows • Parallel Systems Joiner (PSJ)
SPECIFIC SOLUTIONS the addition of a further UPS into an Allows two groups of UPS to be
The UPS can be adapted to meet the most existing system, without the need to connected in parallel whilst operating,
specific requirements. Contact our TEC switch off the existing UPS or transfer in the event of maintenance (with no
team to discuss specific solutions and them to bypass mode. This guarantees interruption to the output), using a power
options not listed in this catalogue. maximum load protection, even during coupling switch.
maintenance and system expansion; Should one of the UPS in one of the
ADVANCED • Maximum levels of availability, even parallel groups fail, it is automatically
COMMUNICATIONS in the event of an interruption to the excluded.
• Compatible with Riello Connect for parallel bus cable: the system is “FAULT The PSJ connects the remaining UPS, to
remote monitoring; TOLERANT”. the other parallel group via an external
• Advanced multi-platform It is not affected by connection cable bypass, in order to continue to guarantee
communications for all operating faults and continues powering the load load redundancy.
systems and network environments: without disruption, signalling an alarm
PowerShield3 monitoring and shutdown condition;
software included for Windows operating • Efficiency Control System (ECS): a
systems 10, 8, 7, Hyper-V, 2019, 2016, system to optimise the operating
2012, and previous versions, Mac OS X, efficiency of parallel systems, according
Linux, VMWare ESXi, Citrix XenServer and to the power required by the load. N+1
other Unix operating systems; redundancy is guaranteed, with every
• Double RS232 serial; UPS working in parallel at the best load
• 2 slots for the installation of optional level possible to achieve higher overall
communications accessories such efficiency.
as network adapters, potential free
contacts, etc.;
• REPO Remote Emergency Power Off
for switching off the UPS via a remote
emergency button;
• Input for the connection of the auxiliary
contact of an external manual bypass;
• Input for synchronisation from an
external source;