Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

M

D
L

B
G

C
J

A
PROJECT:-

MSWIL PATHREDI
1

1
GENERAL NOTES:
01 Do not SCale from this Drawing.

SE S 02 All dimensions are in mm unless noted otherwise.


03 The dimensions are to be read and not scaled off the drawing.

E 200 200 200 2.9m High AAC Block


04 Any discrepancy in the drawing shall be brought to the notice of the
ARCHITECTS and shall not be changed or altered without the permission
of the architect/ engineer concerned.
4655 690 W2 Wall with Tie Beam above W2 2.9m High AAC Block Wall with Tie Beam above 05 This drawing is to be read in conjunction with other relevant drawings
200

200
Y3 and specification given.

180
245
Exit Entry MD1 200 06 See enlarged floor plans and details for additional dimensions and
1205 2200 1250 975 1500 975 975 1500 975 1325 1500 1300 3190 810 partition types.
450 440 200 200 200 200
5100 200 DRAWING APPROVAL
2

2
Entry ARCHITECTURAL DRAWINGS

2010
DRAWN BY

MUSARRAT..................
CHECKED BY
4900

5000

POOJA..............................
HAND WASH-AREA Drinking

6875 c/c
F.F.L+100.00 lvl. water area VALIDATED BY

6675

2300
W1 QC HEAD .......................................
2.9m High
SERVING AREA APPROVED BY
AAC Block Wall F.F.L+100.00 lvl.
3

3
with Tie Beam above
HOD .......................................
200

100

REFER DETAILS 1200 2200 1900


DINING AREA
12075
A
D B
200
4000
200
SW

2080
C
120 PAx
F.F.L+100.00 lvl.

13750 c/c
2535

2535

F.F.L+100.00 lvl.

14635 o/o
as/detail

410
200
Y2
200 200 MD1
200
4

4
2150 2270 680 10575 2.9m High 1500 710

990
Eq Eq AAC Block Wall 225
DUST BIN 1200
450

180

975
with Tie Beam above
200

200
600

2.9m High
200

AAC Block Wall DW

1500
with Tie Beam above W2
5100 R0 ISSUED FOR CONSTRUCTION mail 21.07.22

NE
2520

2520

2400
REVISION DESCRIPTION COPIES DATE

PURPOSE OF SENDING

6875 c/c
990
FOR APPROVAL FOR REFERENCE
DISH / POT
5

5
200

200

200
PREPARATION AREA

7360
WASH AREA FOR TENDER GOOD FOR CONSTRUCTION
F.F.L+99.988 lvl. F.F.L+100.00 lvl.
850
6400

FOR ESTIMATION FOR AS BUILT

990
5800

CHECK LIST APPLICABLE ...............................

2660
DUMB IMPACT ON UTILITIES ...............................
1200

MD2 WAITER AS
3480

1500
PROJECT:
W2 / DETAILS
PROPOSED FACTORY EXPANSION PROJECT AT
400

MSWIL PATHREDI

1220
6

6
2685

990
1230

200 200
5500 200 Y1
2300 2600 590 2505 2300 2620 560 2395 1325 2300 1225 650 DRAWING GROUND FLOOR CANTEEN CIVIL PLAN
200

200
TITLE (MAIN BUILDING)
200

200

200
2.4m High AAC Block Wall DRAWING NO MSWIL_PATH_WD_AR-335
W1 W1 W1
with Tie Beam above CLIENT MSWIL PATHREDI

W JOB NUMBER ---

N
SCALE 1:500 @ A2
8000 c/c
NW16000 c/c 8000 c/c
ISSUE DATE
02.12.2022
REVISION NO. NORTH
7

7
SE

R0
S

REVISION DATE

SW
21975 o/o

NE

W
N NW

---

CONSULTANT NAME:
X13 X14 X15
CANTEEN CIVIL LAYOUT
GROUND FLOOR
DECLARATION:-
This drawing is the sole property of Systematic Conscom Ltd.
The drawing should not be reproduced, translated of
transmitted in any from without prior permission from the
8

8
proprietors.

Systematic Conscom Ltd


C-1, A & B, FIRST FLOOR, SECTOR-1, NOIDA-201301
M

E
L

B
G

C
J

You might also like