Professional Documents
Culture Documents
Project No 2
Project No 2
2
7. If a carport is allotted for the
PROJECT TITLE: project with a paved surface area of
A proposed Two-Storey, Two 15sqm, what would be the allowed
Bedroom Single-Attached Residential length of the abutment wall?
Project on an R-2 zone with a five a. 6.00m b. 7.00m
percent (5%) slope c. 5.00m d. 10.00m
22. What is the actual length of the 31. What is the BHL for the project?
firewall? a. 6m b. 9m
a. 5.20m b. 6.20m c. 10m d. 7.5m
c. 6.00m d. 5.10m
32. What is the actual FLAR for the
23. What custom accessory is allowed project?
for the project? a. 111.5sqm b. 112sqm
a. Generic Pharmacy c. 112.5sqm d. 110.5sqm
b. Hometels
c. PCSO 33. What is the fire resistive rating
d. Motels for the firewall?
a. 1 hour b. 2 hours
24. What principal use is allowed for c. 3 hours d. 4 hours
the project?
a. Lying-in Clinic 34. What is the ceiling height
b. Water Refill Station provided for a habitable room with
c. Bakery artificial ventilation?
d. Home for the Aged a. 3.00m b. 2.70m
c. 2.10m d. 2.40m
25. What conditional use is allowed
for the project? 35. What is the ceiling height
a. LPG retail shop provided for a habitable room with
b. Plant nursery natural ventilation?
c. Pre-school a. 3.00m b. 2.70m
d. Convent c. 2.10m d. 2.40m
26. What is the area allowed for a 36. What is the air space requirement
business office for the project? for the business office, if
a. 5.70sqm b. 5.75sqm introduced?
c. 5.80sqm d. 6.75sqm a. 11cu.m of air space per
person b. 10cu.m of air space
27. What is the area allowed for per person
beauty parlor should the wife engaged c. 12cu.m of air space per
in home occupation? person d. 13cu.m of air space
a. 5.70sqm b. 5.75sqm per person
c. 5.80sqm d. 6.75sqm
37. What is the minimum size for a ¾
28. What is the minimum requirement bath?
for air changes in an LPG retail shop? a. 1.5m x 1.8m b. 1.0m x 1.8m
a. 0.21cu.m/min c. 1.5m x 2.0m d. 1.2m x 1.8m
b. 0.20 cu.m/min
c. 0.22cu.m/min 38. If the area of the business office
d. 0.23cu.m/min is as stated in this project, what is
the actual area for the window(s)
openings? 47. What is the recommended space for
a. .0620sqm b. .0650sqm a total dining area for 4 persons?
c. .0675sqm d. .0625sqm a. 10.80sqm b. 16.20sqm
c. 12.60sqm d. 14.40sqm
PROJECT NO. 2 SITE PLANNING
48. Where do you place a divan?
39. What minimum tree calliper is a. Living area
allowed alongside the perimeter fence? b. Dining area
a. 200mm b. 180mm c. Side Terrace
c. 150mm d. 250mm d. Foyer
40. Where is the best location for the 49. What furniture is recommended for
Service Entry/Exit? the dining area?
a. back of the house a. side table b. console table
b. side of the house c. coffee table d. Shelves
c. at the West sector
d. none of the above 50. What flooring finish is best for
the bedroom?
41. Where should the principal front a. Ceramic tile
of the project be placed? b. wood planks
a. facing the minor road c. Vigan tile
b. facing the major road d. Linoleum
c. corner of the house
d. does not matter 51. What floor finish is best for the
living area?
PROJECT NO. 2 ARCHITECTURAL INTERIORS a. Vinyl sheet
42. What type of lighting should be b. Granite tile
placed the Entry Porch? c. Granite strip
a. Task lighting d. Ceramic
b. Diffused lighting
c. General lighting 52. What wall finish is recommended
d. Downlight for the splash wall of the kitchen?
a. Unglazed tile
43. What type of lighting is best b. Enamel paint
placed at the Foyer? c. Textured tile
a. Task lighting d. Glazed tile
b. Decorative lighting
c. General lighting 53. What type of window would you
d. Downlight recommend for the bedroom?
a. Sliding b. Casement
44. What type of lighting is c. Awning d. Jalousies
appropriate for the Stairway?
a. Task lighting 54. What type of window is best for
b. Diffused lighting the living area?
c. General lighting a. Hooper b. Casement
d. Downlight c. Awning d. Jalousies