3. Please open the cover of radar and check terminal board inside radar.
The voltage between terminal no.1 and no.2 should be about 10.5V to
11V.
Voltage between terminal No.1 and No.2 was found to 9.99V
continuously.
Please put F4 fuse 250mA not 500A, it may destroy the card and radar
as well.
Most of the time the Fuse blown is due to shorting at the radar (water
ingress).
Vessel did not have same size 250 mA fuse of same size but had 250
mA fuse of different size. Same was soldered to electrical cable and
fixed in fuse slot.