Download as pdf
Download as pdf
You are on page 1of 4
PT. LARAS BANGUN KREASI JL. BINTARO JAYA NO. 54 JAKARTA SELATAN 12560 REPORT NO LOCATION TELP. (021) 7345734 / 081314990519 2009/05/24 DATE 1 24-05-2021 SPEC API :74 SUMMARY RESULT REPORT JAKARTA ITEM] QTY DECRIPION REMARKS USED DRILING TOOL INSPECTION SERVICES IN ACCORDANCE WITH API 5A VISUAL THREAD INSPECTION, FULL LENGTH DRIFT, MAGNETIC, PARTICLE INSPECTION BIT SUB 2-7/8" REG BOX X 2-3/8" IF BOX, SIZE OD 3-1/2", ID 1-1/2", LENGTH 16" MATERIAL 4140; PRODUK : LOKAL (INDONESIA); C/W . C.0.C & INPECTION REPORT TRIPARTY DARI LBK BIT SUB 3-1/2" REG BOX X 2-7/8" IF BOX, SIZE OD 4", ID 1-1/2", LENGTH 16" MATERIAL 4140; PRODUK : LOKAL (INDONESIA); C/W . C.0.C & INPECTION REPORT TRIPARTY DARI LBK BIT, SUB, 3-1/2" REG BOX X 2-3/8" IF BOX, SIZE OD 4", 1D.1.5", LENGTH 16" MATERIAL 4140; PRODUK : LOKAL (INDONESIA); C/W . C.0.C & INPECTION REPORT TRIPARTY DARI LBK REMARK : NOTE : VISUAL THREAD INSPECTION ONLY MAGNETIC PARTICLE INSPECTION FULL LENGTH DRIFT ITTED THREAD 'HREAD DAMAGED ALLED THREAD EAL DAMAGED AB 4.SB=SWOLLENBOX = INSPECTOR: SURONO ASNT LEVEL II PT. LARAS BANGUN KREASI JL. BINTARO JAYA NO. 54 JAKARTA SELATAN 12560 TELP. (021) 7345734 / 081314990519 REPORTNO —:.009/05/24 PIPE TALLY Bit Sub LOCATION : JAKARTA TYPE OF PIPE : BIT SUB DATE 1 24-05-2021 SPEC API :74 SIZE : 2-7/8" CONNS : 2-7/8” REG BOX X 2-3/8” IF BOX GRADE: 4140 NO JOINT NO. LENGTH | BOX Box BODY REMARKS 1 352-05-2021 16” OK OK OK REMARK : 1. VISUAL THREAD INSPECTION ONLY MAGNETIC PARTICLE INSPECTION FULL LENGTH DRIFT NOTE: 41, PT = PITTED THREAD 2. TD = THREAD DAMAGED GALLED THREAD SWOLLEN BOX SEAL DAMAGED A INSPECTOR: SURONO ‘ASNT LEVEL Il REPORT NO LOCATION 1009/05/21 : JAKARTA TYPE OF PIPE : BIT SUB PIPE TALLY Bit Sub PT. LARAS BANGUN KREASI JL. BINTARO JAYA NO. 54 JAKARTA SELATAN 12560 TELP. (021) 7345734 / 081314990519 DATE 1 24-05-2021 SPEC API :74 SIZE : 3-4/2” CONNS : 3-1/2” REG BOX X 2-7/8” IF BOX GRADE: 4140 NO JOINT NO. LENGTH | BOX Box BODY REMARKS 1 353-05-2021 16” OK OK OK 2 354-05-2021 16” OK OK OK 3 355-05-2021 16” ok OK OK REMARK : 1. VISUAL THREAD INSPECTION ONLY MAGNETIC PARTICLE INSPECTION FULL LENGTH DRIFT NOTE: 41, PT = PITTED THREAD 2. TD = THREAD DAMAGED GALLED THREAD SWOLLEN BOX . SD = SEAL DAMAGED I INSPECTOR: SURONO ‘ASNT LEVEL Il PT. LARAS BANGUN KREASI JL. BINTARO JAYA NO. 54 JAKARTA SELATAN 12560 TELP. (021) 7345734 / 081314990519 REPORTNO —: 09/05/21. DATE + 24-05-2021 SPEC API :74 PIPE TALLY Bit Sub LOCATION JAKARTA TYPE OF PIPE : BIT SUB SIZE : 3-4/2” CONNS : 3-1/2” REG BOX X 2-3/8” IF BOX GRADE: 4140 NO JOINT NO. LENGTH BOX BOx BODY REMARKS 4 356-05-2021 16” OK OK OK 2 357-05-2021 16” OK OK OK REMARK : 1. VISUAL THREAD INSPECTION ONLY MAGNETIC PARTICLE INSPECTION FULL LENGTH DRIFT NOTE: 41, PT = PITTED THREAD LBK 2. TD = THREAD DAMAGED qa = GALLED THREAD . SWOLLEN BOX INSPECTOR: SURONO SEAL DAMAGED ASNT LEVEL II

You might also like