Professional Documents
Culture Documents
CDS v2.7 QuickReferenceSheet en
CDS v2.7 QuickReferenceSheet en
com/chem/openlabcds
Part Number M8410-90061 Rev. C
Edition 04/2022
Document Number D0002171en Rev. B
Access Instruments and Projects Acquire Data Analyze and Report Data
CONTROL PANEL CREATE ACQUISITION METHOD REVIEW DATA
Use the Desktop icon to launch OpenLab Control Panel. Define acquisition and instrument parameters for runs using this To load data, double-click node in the Data Selection view
method. Pin injections or result sets for comparison
Download to instrument to use new parameters immediately. Use Peak Explorer to view a sequence at a glance and
MANAGE USERS
identify trends or artifacts.
ROLE: SYSTEM ADMIN Create custom result sets based on existing injections (right-click
Assign users to groups
RUN A SINGLE SAMPLE
nodes in the injection tree to add them, click Create new Result Set
Assign roles to groups Enter sample parameters in the ribbon).
Use default roles or assign privileges to roles Include acquisition method and (optional) processing method
Use the Integration Optimizer to quickly adjust peak baselines.
(use role Chemist for Acquisition and Data Analysis) Run
Edit security policy
Manage licenses INJECTIONS AND PROCESSING METHODS
RUN A SEQUENCE
A processing method may already be linked (assigned) to the data.
Create a new sequence If not, create new master method
PROJECTS Open and edit a previously saved sequence
Link injections to the master processing method
Import sequence from a result set or a CSV file (also possible via
ROLE: PROJECT ADMIN drag and drop) A result set method (stored in result set folder) is generated
Create projects to organize your data: Click Apply Template to apply a sequence creation template on linking the master method to the injections.
Activate method audit trails Reprocess (automatic after linking, or manually)
SEQUENCE
Apply project-specific options
Add custom parameters for samples and compounds Edit sequence table:
Right-click and use Fill-down to edit rows, copy/paste entire rows, EDIT PROCESSING METHOD
pin columns at the front Processing methods are divided in sections: e.g.
Create shortcut for Data Analysis with a project.
Edit injections and sequence parameters: Integration Events for all or for specific signals
Launch Data Analysis for a project. For automated processing and reporting: enter existing processing Compounds:
method Add compounds: Right-click a peak, or right-click the compound table.
Define name of the result set Calibration: Set number of calibration levels in the General tab
INSTRUMENTS
Spectra: MS or UV reference spectra for confirmation or purity checks
ROLE: INSTRUMENT ADMIN SEQUENCE CREATION TEMPLATE
Extraction > Spectrum: Background correction settings
Create and configure instruments Create a new template in the Sequence Creation Template window:
Tools > Custom Calculation: Extend default calculations
Monitor instruments
Create shortcut for acquisition with an instrument. Use for cyclic sequences with varying numbers of samples.
REPORT AND PRINT
Launch Acquisition for an instrument.
Import default templates into your project
STATUS (start customizing templates from here):
View Run Queue, Instrument status, Online signals Data Selection > Import Default Templates
Print results manually:
In Data Analysis, edit the processing method Reports section,
LAUNCH DATA ANALYSIS
and link the method. Click Print all in the ribbon.
Click icon in the History tab of the Run Queue to review completed Print processing method:
single injections or sequences in Data Analysis. Go to Data Processing > File ribbon tab > Print Method
Print Individual PDF:
Go to Reporting > Preview > Save as PDF
Sequence summary report: submenu Save result set summary report