Professional Documents
Culture Documents
FG VELODUCT Technical Catalogue Technical UN
FG VELODUCT Technical Catalogue Technical UN
VELODUCT®
TECHNICAL DATA
Round ducting VELODUCT® - Technical data 3
CONTENTS
DUCT
bbb
STANDARD SIZES
Weight
BDEK-a-bbb
(kg/m)
-008 0.9 Sizes 025–125
-010 1.1
-012 1.4
-016 1.8
-020 2.7
-025 3.3
-031 4.1
-040 6.5
-050 8.2
-063 12.2
-080 15.4
-100 25.5
-125 31.9
OTHER SIZES
Weight
BDEK-a-bbb
(kg/m)
-014 1.6
-015 1.7
-018 2.3
-022 3.0
-028 3.7
-030 4.0
-035 5.8
-045 7.4
-056 10.7
DUCT
STANDARD SIZES
t Weight
EKOD-a-bbb-1
(mm) (kg/m)
-008 0.5 1.1 Sizes 031–125
-010 0.5 1.3
-012 0.5 1.7
-016 0.5 2.1
-020 0.5 2.7
-025 0.5 3.3
-031 0.5 3.9
-040 0.7 7.9
-050 0.7 10.0
-063 0.7 12.2
-080 0.7 15.4
-100 0.9 25.5
-125 0.9 31.9
DUCT
Sizes 010–025
STANDARD SIZES
t Weight
ESAD-a-bbb-1
(mm) (kg/m)
-010 0.7 2.0
-012 0.7 2.5
-016 0.7 3.2 Sizes 031–100
-020 0.7 4.0
-025 0.7 5.0
-031 0.7 6.3
-040 0.7 7.9
-050 0.7 10.0
-063 0.7 12.2
-080 0.7 15.5
-100 0.9 25.5
OTHER SIZES
t Weight
ESAD-a-bbb-1
(mm) (kg/m)
-015 0.7 3.0
-030 0.7 6.0
-056 0.7 11.2
L STANDARD SIZES
L Weight
EFLE-bbb-1
(mm) (kg)
-010 250 0.16
-012 250 0.19
-016 250 0.23
-020 250 0.28
-025 250 0.34
bbb -031 250 0.42
-040 250 0.53
-050 250 0.65
-063 250 0.81
-080 250 1.02
-100 250 1.26
DUCT VELOFLEX
aaa-012
aaa-040
STANDARD SIZES
Weight
FLEK-aaa-120 aaa-120
(kg)
-010 1.50
-012 1.96
-016 2.42
STANDARD SIZES
Length Length Weight
FLEX-aaa-bbb
max min (kg)
-010-012 200 153 0.30
-010-040 640 438 0.86
-010-120 1720 1188 2.26
-012-012 200 153 0.37
-012-040 640 438 1.11
-012-120 1720 1188 2.91
-016-012 200 153 0.42
-016-040 640 438 1.39
-016-120 1720 1188 2.64
JOINT
Lp Lp Lp
INSERTION JOINT
bbb
bbb bbb
Li Li Li
BEND
OTHER SIZES
L r Li Weight
BDEB-15-bbb
(mm) (mm) (mm) (kg)
-014 20 140 35 0.22
-015 20 150 35 0.24
-018 25 180 35 0.36
-022 30 224 35 0.50
-028 40 280 35 0.70
-030 40 300 35 0.80
-035 50 355 60 1.50
-045 60 450 60 2.00
-056 75 560 60 2.80
BEND
BEND
Li
L
bb
b
BEND
BEND
L Li
L Li
bbb bbb
r r
BEND
Li
Li
bbb bbb
r
r
L
q, m3/h q, m3/h
100 200 300 400 500 100 200 500 1000 2000 5000 10000
100 100
050
025
040
063
031
020
016
45
50 45 50
40
40
35
20 35 20
30
30
e
Siz
25
10 10
)
B(A
∆pt, Pa
,d
010
25
LA
20
012
20 5
5
20 30 40 50 100 200 20 50 100 200 500 1000 2000 4000
q, l/s q, l/s
BEND
BDEB 90° - SHORT, PRESSED, FIT-ON – INSERTION BDEB 90° - SHORT, FABRICATED, FIT-ON – INSERTION
Lp
Lp
bbb
bbb
r Li r
Li
L
q, m3/h q, m3/h
100 200 300 400 500 100 200 500 1000 2000 5000
100 100
040
020
025
031
016
45
50 45 50
40
40
35
20 35 20
30
30
e
Siz
25
10 10
)
B(A
∆pt, Pa
,d
010
25
LA
20
012
20 5
5
20 30 40 50 100 200 20 50 100 200 500 1000 2000
q, l/s q, l/s
BEND
bbb Li
bbb
150
100
0
1
03
01
02
01
01
02
50
20
10
5
∆pt, Pa
1
5 10 20 50 100 250 500
q, l/s
BDET-1 - T-PIECE, PRESSED BRANCHES, CONCENTRIC BDEX-1 - CROSS, PRESSED BRANCHES, CONCENTRIC
ccc ccc
r r
Li Li
H H
bbb bbb
Li L Li L
BDET-1 - T-PIECE, PRESSED BRANCHES, CONCENTRIC BDEX-1 - CROSS, PRESSED BRANCHES, CONCENTRIC
BDET-1 - T-PIECE, FABRICATED BRANCHES, CONCENTRIC BDEX-1 CROSS - FABRICATED BRANCHES, CONCENTRIC
ccc ccc
Li Li
H H
bbb bbb
Li L
Li L
BDET-2 - T-PIECE, FABRICATED BRANCHES, ECCENTRIC BDEX-2 - CROSS, FABRICATED BRANCHES, ECCENTRIC
ccc ccc
Li Li
H H
bbb bbb
Li L
Li L
STANDARD SIZES
Weight Weight
H L Li
BDE(T,X)-2-bbb-ccc BDET BDEX
(mm) (mm) (mm)
(kg) (kg)
-040-010 230 85 60/35 2.7 2.8
-012 235 105 60/35 3.0 3.2
-016 240 125 60/35 3.1 3.6
-020 245 150 60/35 3.6 3.9
-025 255 185 60/35 4.1 4.6
-031 265 225 60/35 5.0 5.5
-050-010 280 85 60/35 3.6 3.6
-012 285 105 60/35 3.8 4.0
-016 290 125 60/35 4.1 4.4
-020 295 150 60/35 4.5 4.7
-025 305 185 60/35 5.4 5.7
-031 315 225 60/35 6.0 6.4
-040 330 280 60 7.5 8.5
-063-010 345 85 60/35 4.4 4.7
-012 350 105 60/35 4.8 5.0
-016 355 125 60/35 5.3 5.6
-020 360 150 60/35 5.7 6.0
-025 370 185 60/35 6.8 7.1
-031 380 225 60/35 7.6 8.0
-040 395 280 60 9.2 10
-050 410 345 60 11 12
-080-040 480 285 95/60 13 14
-050 495 350 95/60 16 17
-063 515 435 95/60 18 20
-100-050 595 350 95/60 17 23
-063 615 435 95/60 26 26
-080 645 545 95 32 35
-125-063 740 435 95/60 32 30
-080 770 545 95 36 34
-100 800 675 95 46 49
BDET-2 - T-PIECE, FABRICATED BRANCHES, ECCENTRIC BDEX-2 - CROSS, FABRICATED BRANCHES, ECCENTRIC
ccc ccc
Li Li
H H
bbb bbb
Li L
Li L
REVERSED T-PIECE
ccc
Li
bbb
Li ccc
REVERSED T-PIECE
ccc
Li
bbb
Li L
T-PIECE
BDET-3 - T-PIECE, SHORT, INSERTION - FIT-ON BDET-4 - T-PIECE, SHORT, FIT-ON - FIT-ON
ccc ccc
r r
Li Li
H H
bbb bbb
Li L Lp Lp L
STANDARD SIZES
H L Li Weight
FLET-aaa-bbb
(mm) (mm) (mm) (kg)
-010-010 108 90 35 0.50
-012-010 121 85 35 0.57
-012-012 121 100 35 0.32
-016-010 138 90 35 0.67
-016-012 138 100 35 0.80
-016-016 138 125 35 1.05
Li
Li cc
cc c
c H
H
bbb
bbb
Li L Li
c
cc
Li L Li
Li
Li cc
cc c
c H
H
bbb
bbb
Li L Li
c
cc
Li L Li
Li
Li cc
cc c
c H
H
bbb
bbb
Li L Li
c
cc
Li L Li
BRANCH
ccc ccc
r r
Li Li
H H
bbb bbb
BRANCH
ccc
r
Li
bbb
BRANCH
ccc
Li
bbb
BRANCH
bbb bbb
r
r Li Li
12-22
12-30
Sizes 008 - 063 pressed Sizes 008 - 020 extruded sealing and 080 - 125 Veloduct sealing
bbb
r
Li
12-22
Sizes 080 - 125 fabricated Sizes 025 - 063 Veloduct Twin sealing
REDUCER
bbb ccc
REDUCER
bbb ccc
REDUCER
BDED-2 - REDUCER, ECCENTRIC, FIT-ON - INSERTION BDED-4 - REDUCER, ECCENTRIC, INSERTION - INSERTION
Lp L Li
Lp Li
ccc ccc
bbb bbb
REDUCER
Lp L Li
bbb ccc
REDUCER
Lp L Li
ccc
bbb
REDUCER
Li L Li
bbb ccc
REDUCER
Li L Li
ccc
bbb
REDUCER
BDKF-2 - REDUCER, ECCENTRIC, FIT-ON - INSERTION BDKF-4 - REDUCER, ECCENTRIC, INSERTION - INSERTION
Lp L Li Li L Li
ccc ccc
bbb bbb
T in the code: separate packing (M1) T in the code: separate packing (M1)
LID
Lp L
bbb bbb
Li
CLEANING COVER
Lp Lp
bbb
bbb
20-30 20-30
FIRE RESISTANCE CLASS E 60 (EI 60) 1) FIRE RESISTANCE CLASS E 60 (EI 60)1)
Lp Weight Lp Weight
BDEG-2-bbb BDEG-3-bbb
(mm) (kg) (mm) (kg)
-010 35 0.29 -010 35 0.17
-012 35 0.35 -012 35 0.22
-016 35 0.49 -016 35 0.28
-020 35 0.73 -020 35 0.35
-025 35 1.10 -025 35 0.50
-031 35 1.50 -031 35 0.74
1) In
accordance with BBR 5:6213, the cover may be used where 1) In
accordance with BBR 5:6213, the cover may be used where
components to fire resistance class EI 60 are required provi- components to fire resistance class EI 60 are required provi-
ded that the cover is installed at a min. distance of 500 mm ded that the cover is installed at a min. distance of 500 mm
from an escape route and at a min. distance of 200 mm from from an escape route and at a min. distance of 200 mm from
any combustible material. any combustible material.
If the fire resistance requirement is EI 30, the corresponding If the fire resistance requirement is EI 30, the corresponding
protective distance must be at least 400 mm (escape route) protective distance must be at least 400 mm (escape route)
and 150 mm (combustible material) respectively. and 150 mm (combustible material) respectively.
THE TYPE APPROVAL FOR FIRE RESISTANCE CLASS DOES NOT THE TYPE APPROVAL FOR FIRE RESISTANCE CLASS DOES
APPLY TO THE COMPONENT BELOW. NOT APPLY TO THE COMPONENT BELOW.
Lp Weight Lp Weight
XDEG-2-bbb XDEG-3-bbb
(mm) (kg) (mm) (kg)
-040 60 3.4 -040 60 1.5
-050 60 4.7 -050 60 2.0
-063 60 6.9 -063 60 2.8
CLEANING COVER
BDEG-4 - CLEANING COVER WITH HANDLE, INSERTION BDEG-4 - CLEANING COVER WITH HANDLE, INSULATED,
INSERTION
L L
bbb bbb
Li Li
CLEANING COVER
30 60
10 50
bbb
STANDARD SIZES
Weight
BDEG-7-bbb
(kg/m)
-010 0.35
-012 0.40
-016 0.70
-020 0.90
-025 1.40
-031 2.00
CLEANING COVER
1C85 (010-016)
300 (020-031)
400 (040-050)
500 (063-100
Size 125
BRANCH
Li L
bbb
bbb
øD
H
L1
aaa
H
H1
41
L A
* Fit-on measure that fits
bbb
* outside pipes or detail.
30
L p10A, dB (A)
1
20 25 20 30 40 50 100 200
qv, l/s
Size
20
A)
10
dB(
LA,
010
020
025
016
031
012
5
10 20 50 100 200 500
q, l/s
050
063
080
020
025
040
010
016
100
031
012
125
50
40
35
(A)
, dB
30
20
10A
25
Lp
∆pt, Pa
10 20
5
4
3
STANDARD SIZES 1
10 20 50 100 200 500 1000 2000 5000 10000
A L Li Weight qv, l/s
BDKU-aaa
(mm) (mm) (mm) (kg)
-010 170 70 35 0.18
-012 190 70 35 0.21
-016 230 70 35 0.26 SUPPLY AIR
-020 270 70 35 0.3
-025 315 70 35 0.4 q, m3/h
-031 370 70 35 0.5 50 100 200 500 1000 5000 10000 30000
100
40
050
063
080
020
025
-040 455 80 60 1.0
040
031
100
016
35
(A)
125
10A
10
5
4
3
1
10 20 50 100 200 500 1000 2000 5000 10000
qv, l/s
Li
Li
bbb bbb
XBEZ-72 – SUPPLY AIR NOZZLE BDEZ – PLASTIC PROTECTIVE CAP, PUSHED DIMENSION
INSERTION
ø50
110
bbb
bbb
Li 60
35
100
)
30
(A
0
dB
01
A,
ze
L
Si
25
50
20
∆pt, Pa
25
10 20 30 40 50
q, l/s
ØG - n pieces
bbb
B
A
Li L
Li L
A
Sizes 008 - 012
bbb
120
Li L
A
Sizes 016 - 031
70 bbb
A B
Li L
bbb
Sizes 016 - 063
B
STANDARD SIZES
L A B Li Weight
BDEP-aa-bbb
Li L (mm) (mm) (mm) (mm) (kg)
-008 135 205 40 35 0.60
Sizes 040 - 063 -010 135 215 50 35 0.65
-012 135 227 60 35 0.75
-016 135 245 98 35 1.0
STANDARD SIZES
-020 135 265 118 35 1.2
L A B Li Weight -025 125 290 143 35 1.6
BDEP-a-bbb-c (mm) (mm) (mm) (mm) (kg)
-031 125 322.5 175 35 2.0
-008 135 80 40 35 0.30
-040 160 368 215 60 3.7
-010 135 90 50 35 0.34
-050 160 418 265 60 5.0
-012 135 100 65 35 0.42
-063 160 483 330 95 6.0
-016 135 120 100 35 0.46
-020 135 140 120 35 0.82 *) excl. motor
-025 125 165 145 35 1.2
-031 125 195 175 35 1.5
-040 160 270 220 60 2.7
-050 160 320 270 60 3.9
-063 160 385 335 60 5.2
126
130 C
130 C
A
A
bbb
A
B
bbb
bbb
Li L B
Li L
Sizes 008Li- 012 L
130 C E
Sizes 008 - 012
130 C E 126
bbb A
A
B
bbb
Li L B
bbb
Li L
B
A A
bbb
bbb
B
B
Li L
160
STANDARD SIZES
L A B Li Weight
BDEP-aa-bbb
(mm) (mm) (mm) (mm) (kg)
-040 160 320 217.5 60 4.1
-050 160 374 264 60 5.5
A
-063 160 445 329 60 6.5
bbb
BDEP-46
B BELIMO MOTOR TYPE SF WITH SPRING RETURN
200
Li L
A
STANDARD SIZES
L A B Li Weight
BDEP-aa-bbb
(mm) (mm) (mm) (mm) (kg)
-008 135 205 40 35 2.1
bbb
-010 135 215 50 35 2.2
-012 135 227 60 35 2.3
-016 135 245 98 35 2.6 B
STANDARD SIZES
L A B Li Weight
BDEP-aa-bbb
(mm) (mm) (mm) (mm) (kg)
-040 160 368 215 60 7.0
-050 160 418 265 60 8.3
-063 160 483 330 60 9.3
Lwt = 70 dB 20°
30°
L wt = L80
wt =dB
70 dB30°
200 200 200 200
60
50
60
50 50 50 50
50
40
50
20 20 20 20
20°
Total pressure drop pt , Pa
70 10°
20° 20°
100 100 60 100 60
60
50 50 50
50 50
50
20 20 20
XCEK – SPIRAL DUCT FOR EMBEDDING IN CONCRETE, FIT-ON BDEZ-43 - CEILING AND WALL BRANCH
bbb
T he size of the plate is 255 x 255 mm and the hole size for the
L insertion branch below.
BDEB 90° - SHORT, PRESSED BDEB 90° - SHORT, PRESSED, FIT-ON – INSERTION
Li
Lp
bbb
bbb
r
r
Li
L
L
q, m3/h q, m3/h
100 200 300 400 500 100 200 300 400 500
100 100
50 45 50 45
40 40
20 35 20 35
30 30
e
e
Siz
Siz
10
)
10
)
B(A
B(A
∆pt, Pa
∆pt, Pa
,d
,d
010
25
010
25
LA
LA
012
012
20 20
5 5
20 30 40 50 100 200 20 30 40 50 100 200
q, l/s q, l/s
XBEZ / XCEB - ANGLE DUCT WITH DIFFUSER MOUNTING XCEB - ANGLE DUCT, FIT-ON AND NAIL FLANGE, PRESSED
FRAME, LOW HEIGHT, PRESSED
H H
d2 d2
L L
Li Li
d1 d1
d2
Li
d1
STANDARD SIZES
d1 D2 H L Li Weight
Product code
(mm) (mm) (mm) (mm) (mm) (kg)
XCEB-245 010 012 115 105 35 0.41
XCET –T-PIECE WITH DIFFUSER MOUNTING FRAME, LOW BDET-1 –T-PIECE, SHORT, CASTING
HEIGHT
d2 d2
H H
d1
d1
Li L L Li
XCEA – BRANCH, INSERTION, XCEA – BRANCH, INSERTION, WITH XCEA – BRANCH, INSERTION, WITH
WITH NAIL FLANGE DIFFUSER MOUNTING NAIL FLANGE, INTENDED
FRAME, INTENDED FOR FOR FACTORY CASTING
FACTORY CASTING “FILIGRANBRANCH”
“FILIGRANBRANCH”
10 10 10
D D D
Lp 65 65
GENERAL
The VELODUCT® system is a complete system of round ducting for THE SEAL
which type approval for tightness class D according to EN 12237 has The sealing principle is illustrated in the drawings below. These show
been granted. an insertion fitting and a fit-on (tube) fitting. The seal is made of solid
All duct fittings are equipped with a sealing ring made of EPDM rubber. EPDM rubber and is fixed to the end of the fitting.
The seal is highly resistant to moisture, airborne pollutants and solar
VELODUCT® radiation and can withstand continuous exposure to temperatures
• permits rapid, easy and clean installation between -30°C and +80°C with an unimpaired function.
• can be installed in any climate
• easy to balance DESIGN
• reduces operating cost
• made of fireproof sheet steel
GENERAL
t2 t1
D d D d3
Lp Li
Size D d d3 A Li/Lp t1 tube, t1 tube, D Inner diameter, tubes and fit-on fittings
bbb mm mm mm m2 mm BDEK EKOD d Outer diameter, insertion fittings
008 80.0–80.5 78.8–79.3 100 0.005 d3 Recommended diameter of opening
0.5
010 100.0–100.5 98.8–99.3 125 0.008 A Cross-section area of duct
012 125.0–125.5 123.8–124.3 160 0.012 Li Insertion length
014 140.0–140.6 138.7–139.3 160 0.015 Lp Fit-on length
015 150.0–150.6 148.7–149.3 180 0.018 t1 Sheet metal thickness, tubes
016 160.0–160.6 158.7–159.3 200 0.020 t2 Sheet metal thickness, parts
0.4
018 180.0–180.7 178.6–179.3 224 0.025 35 0.5
020 200.0–200.7 198.6–199.3 250 0.031
022 224.0–224.8 222.5–223.3 280 0.039
025 250.0–250.8 248.5–249.3 315 0.049
028 280.0–280.9 278.4–279.3 355 0.062
030 300.0–300.9 298.4–299.3 355 0.071
031 315.0–315.9 313.4–314.3 400 0.078
035 355.0–356.0 353.3–354.3 450 0.099 0.5
040 400.0–401.0 398.3–399.3 500 0.126
045 450.0–451.1 448.2–449.3 560 0.159
60
050 500.0–501.1 498.2–499.3 630 0.196 0.7
056 560.0-561.2 558.1-559.3 710 0.246
063 630.0–631.2 628.1–629.3 800 0.312
0.7
071 710.0–711.6 708.9-709.3 900 0.396
080 800.0–801.6 798.0–799.3 1000 0.502
090 900.0–902.0 897.0–899.3 1120 0.636
95
100 1000.0–1002.0 997.9–999.3 1200 0.785 0.9
0.9
112 1120.0–1122.5 1117.8–1119.3 1300 0.984
125 1250.0–1252.5 1247.8–1249.3 1400 1.227
Basic calculation data for ducts and duct components having • The data in the charts refer to total pressure drop and are therefore
cross-section to Eurovent 2/3 and design to Eurovent 2/4. direct measurements of the energy loss across the air flow resis-
The rated nominal air flow resistance (pnom) should be corrected with tances. (Pa = 1 J/m3)
regard to leakage and fan connection. • The influence of the choice of velocity on the pressure drop can be
judged directly.
ΣΔptot = Δpnom + Δpleakage + Δpfan conn.
• The difference in pressure drop between the first and the nth branch
The air flow resistances are charted directly in Pa. can be read directly.
DUCTS
200
100
Siz
e
50
20
15
10
5,0
2,0
1,5
1,0
0,5
0,2
0,15
0,1
1 2 5 10 20 50 100 200 500 1000 5000 10000 20000
006
8
200 30
00
following applies:
010
100
012
20
016
100
0
∆pt45° = 0.5 * ∆pt
02
5
50 15
02
1
50
03
100
∆pt30° = 0.33 * ∆pt 10
20
20
/s
10
v, m
10 5
5
5 10
2
2 2
1
1
0,5
1
0,5 1,0
∆pt, Pa
0,2
0,2
0,1
0,1
0,05
0,1
1 10 100 1000 5000
q, l/s
100
02
following applies:
03
50
040
0
50 100 20
05
3
06
0
20
100
125
20 10
/s
10
5
5 10 5
2
2
1
1 2
0,5
0,5 1,0
0,2 1
∆pt, Pa
0,2
0,1
0,1
0,05
0,1
10 100 1000 10000 100000
q, l/s
Area increase
Area increase Area increase
Area decrease
Area decrease Area decrease
100 100 100
50 50 50
20 20 20
10 10 10
∆pt, Pa
∆pt, Pa
∆pt, Pa
5 5 5
2 2 2
1 1 1
1 2 5 10 20 50 1 2 5 10 20 50 1 2 5 10 20 50
v, m/s air velocity v, m/s
Incoming v, m/s air velocity v, m/s
Incoming v, m/s air velocity v, m/s
Incoming
INSTALLATION INSTRUCTIONS
Fig. 1
INSTALLATION INSTRUCTIONS
1. Select a suitable section of ducting and check that the duct can be Fig. 4
run in accordance with the drawing before collecting the necessary
components from the storage area.
Fig. 2
2. Collect the necessary fittings and tubes. Check that they aren’t
damaged in any way that would cause air leakage in the finished Fig. 5
ducting system, such as holes left after rivets/screws have been
removed from reused parts. If the storage area is well arranged and
has good weather protection, the components will be easier to find,
and the risk of damage or wastage will be reduced. A sign such as INSTALLATION
that shown in Fig. 3 will facilitate the delivery of materials. 4. Assemble suitable sections on the floor. To facilitete the fitting of
one part into another, turn one of them while pushing it in.
VELODUCT U P P L AG S P L AT S
Fig. 3
Fig. 6
INSTALLATION INSTRUCTIONS
Fig. 7
Fig. 8
INSTALLATION INSTRUCTIONS
1
INSTALLATION OF PRODUCTS WITHOUT SEAL OF APPROVAL
12. Products without seal of approval incorporated into the ducting
and fitted in accordance with the provisions of the seal of approval
must be sealed so that they will definitely be in conformance with
tightness class D. The seal at joints, etc. must be checked visually
before fitting into the ducting. A test report must be produced for
products with concealed joint seals. Components not provided with 2
VELODUCT seals must be sealed in accordance with relevant parts Fig. 14 a
of the example below. The sealing material should be non-ageing
and permanently elastic.
3
3
Fig. 14 b
Fig. 14 c
INSTALLATION INSTRUCTIONS
2
1
3 4
1
Fig. 16.
Fig. 15.
FläktGroup is the European market leader for smart and energy efficient Indoor Air
and Critical Air solutions to support every application area. We offer our customers
innovative technologies, high quality and outstanding performance supported by
more than a century of accumulated industry experience. The widest product range
in the market, and strong market presence in 65 countries worldwide, guarantee
that we are always by your side, ready to deliver Excellence in Solutions.