PRESSURE REDUCING

VALVE

1
Belven N.V. l Blokhuisstraat 24 l 2800 Mechelen l Belgium l belven@belven.com l www.belven.com
PRESSURE REDUCING VALVE – BV 421

The BV421 Pressure Reducing Valve, from the Belven - Stallion range, is designed to set, adjust and maintain
the downstream pipeline pressure, regardless of the variation in the upstream pressure. In this model, the
Belven - Stallion (Main Valve) BV400 coupled with the Pressure Reducing Pilot BV401, is designed to
automatically reduce the fluctuating upstream pressure to a constant lower downstream pressure. The
Control is by the normally open Pressure Reducing Pilot BV401. When the BV401 is open, it allows liquid to
flow out of the Stallion cover chamber. When it is closed, it allows the liquid to fill the Stallion cover chamber.
Normally a decrease in downstream pressure causes the Valve to open, consequently raising the pressure
and vice versa. The BV421 comes with WRAS approved coating, suitable for all potable Water applications.

TECHNICAL DESCRIPTION

Application : Plumbing Water Network, Water Networks, Pump Station, Irrigation


Pressure Rating : PN16 (PN 10, PN25 available on request)
Temperature Rating : -10⁰C to 80⁰C at 16 bar
Coating : Internal and External coated with WRAS approved Fusion Bonded Epoxy
(FBE), Blue (RAL 5015), Coating Thickness (DFT) = minm.250 microns.
Standard Flange Drilling : EN1092 PN 10, PN16, PN25 or ASME B16.5 CL150

FEATURES

Compact and simple design


Easy to Maintain
Excellent Corrosion Resistance. WRAS approved FBE coating of min 250 microns
Reduce the higher upstream pressure and keep the downstream pressure constant as the pilot setting
(adjustable).
BV/CAT/DC/18-00

Maintains downstream pressure regardless of variation of upstream pressure or downstream flow

2
Belven N.V. l Blokhuisstraat 24 l 2800 Mechelen l Belgium l belven@belven.com l www.belven.com
PRESSURE REDUCING VALVE – BV 421
ASSEMBLY

No Component Material
1 Main Body – Stallion BV 400 Ductile Iron
2 Needle Valve Stainless Steel
3 Pressure Reducing Pilot BV401 Stainless Steel
4 Ball Valve Stainless Steel
5 Inlet Pressure Gauge (Optional)
6 Outlet Pressure Gauge (Optional)
7 Strainer Stainless Steel

COMPONENT MATERIAL

No Component Material Material Grade


1 Body / Bonnet Ductile Iron BS EN 1563 GJS-500-7
2 Diaphragm Nylon Reinforced Rubber EPDM +Nylon Fabric
3 Stem / Seat Stainless Steel AISI 304/316
4 Seal Ring Rubber EPDM
5 Spring Stainless Steel AISI 304/316

INSTALLATION

3
Belven N.V. l Blokhuisstraat 24 l 2800 Mechelen l Belgium l belven@belven.com l www.belven.com
PRESSURE REDUCING VALVE – BV 421
DRAWING

20 10

5/6
13

15

16
E

19

DIMENSIONS
ØD ØK N-Ød ØB
DN L H
PN10 PN16 PN25 PN10 PN16 PN25 PN10 PN16 PN25 PN10 PN16 PN25
50 230 177 165 165 165 125 125 125 4-Ø19 4-Ø19 4-Ø19 Ø99 Ø99 Ø99
65 290 202 185 185 185 145 145 145 4-Ø19 4-Ø19 8-Ø19 Ø118 Ø118 Ø118
80 310 219 200 200 200 160 160 160 8-Ø19 8-Ø19 8-Ø19 Ø132 Ø132 Ø132
100 350 243 220 220 235 180 180 190 8-Ø19 8-Ø19 8-Ø23 Ø156 Ø156 Ø156
125 400 243 250 250 270 210 210 220 8-Ø19 8-Ø19 8-Ø28 Ø156 Ø156 Ø156
150 480 333 285 285 300 240 240 250 8-Ø23 8-Ø23 8-Ø28 Ø211 Ø211 Ø211
200 600 428 340 340 360 295 295 310 8-Ø23 12-Ø23 12-Ø28 Ø266 Ø266 Ø274
250 730 478 405 405 425 350 355 370 12-Ø23 12-Ø28 12-Ø31 Ø319 Ø319 Ø330
300 850 538 460 460 485 400 410 430 12-Ø23 12-Ø28 16-Ø31 Ø370 Ø370 Ø389
350 980 550 520 520 555 460 470 490 16-Ø23 16-Ø28 16-Ø34 Ø429 Ø429 Ø448
400 1100 710 580 580 620 515 525 550 16-Ø28 16-Ø37 16-Ø28 480 480 503
450 1200 720 640 640 670 565 585 600 20-Ø28 20-Ø31 20-Ø28 530 548 548
500 1250 822 715 715 730 620 650 660 20-Ø28 20-Ø34 20-Ø28 582 609 609
600 1450 885 840 840 845 725 770 770 20-Ø31 20-Ø37 20-Ø31 682 720 720

*Higher sizes on request

FLOW RATES
Valve Size (DN) 50 65 80 100 150 200 250 300 400 500 600
Min. Flow (L/s) 1 1.7 2.5 3.9 8.8 15.7 24.5 35.3 62.8 98.2 141.4
Max. Continuous Flow (L/s) 6.7 11.3 17.1 26.7 60.1 106.8 166.9 240.3 427.3 667.6 961.3
Max. Intermittent Flow (L/s) 9.8 16.6 25.1 39.3 88.4 157.1 245.4 353.4 628.3 981.7 1413.7
BV/CAT/DC/18-00

- Flow rates given is for reference only.


- Factors such as Inlet pressure, Outlet pressure, Flow rate, Cavitation zone, etc. must be considered