Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Test Equipment Solutions Datasheet

Test Equipment Solutions Ltd specialise in the second user sale, rental and distribution of
quality test & measurement (T&M) equipment. We stock all major equipment types such as
spectrum analyzers, signal generators, oscilloscopes, power meters, logic analysers etc from
all the major suppliers such as Agilent, Tektronix, Anritsu and Rohde & Schwarz.

We are focused at the professional end of the marketplace, primarily working with customers
for whom high performance, quality and service are key, whilst realising the cost savings that
second user equipment offers. As such, we fully test & refurbish equipment in our in-house,
traceable Lab. Items are supplied with manuals, accessories and typically a full no-quibble 2
year warranty. Our staff have extensive backgrounds in T&M, totalling over 150 years of
combined experience, which enables us to deliver industry-leading service and support. We
endeavour to be customer focused in every way right down to the detail, such as offering free
delivery on sales, covering the cost of warranty returns BOTH ways (plus supplying a loan
unit, if available) and supplying a free business tool with every order.

As well as the headline benefit of cost saving, second user offers shorter lead times, higher
reliability and multivendor solutions. Rental, of course, is ideal for shorter term needs and
offers fast delivery, flexibility, try-before-you-buy, zero capital expenditure, lower risk and off
balance sheet accounting. Both second user and rental improve the key business measure of
Return On Capital Employed.

We are based near Heathrow Airport in the UK from where we supply test equipment
worldwide. Our facility incorporates Sales, Support, Admin, Logistics and our own in-house
Lab.

All products supplied by Test Equipment Solutions include:

- No-quibble parts & labour warranty (we provide transport for UK mainland addresses).
- Free loan equipment during warranty repair, if available.
- Full electrical, mechanical and safety refurbishment in our in-house Lab.
- Certificate of Conformance (calibration available on request).
- Manuals and accessories required for normal operation.
- Free insured delivery to your UK mainland address (sales).
- Support from our team of seasoned Test & Measurement engineers.
- ISO9001 quality assurance.

Test equipment Solutions Ltd


Unit 8 Elder Way
Waterside Drive
Langley
Berkshire
SL3 6EP

T: +44 (0)1753 596000


F: +44 (0)1753 596001

Email: info@TestEquipmentHQ.com
Web: www.TestEquipmentHQ.com
elg0430.qxd 2/22/01 9:55 PM Page 19

DCS 1 kW and 3 kW
DC Programmable
Switching Supplies
he DCS Family of 1 kW and 3 kW
T programmable power supplies
incorporate current mode switching
rates up to 100 kHz in high power
density, low profile chassis. Utilizing
unique packaging techniques, the
DCS Family provides continuous full
output power (1 kW or 3 kW) in any
volt/amp combination within the rated constant-voltage/current mode Options include an internal IEEE-488/
output voltage and current limits. operation. RS 232 interface, isolated analog
programming of voltage or current, and
This family has 10-turn potentiometers The DCS 3 kW Models have push the multichannel slave interface
to adjust voltage and current settings button control of the output standby (Option M85).
that are displayed simultaneously. mode, OVP reset, remote/local
LEDs indicate overtemperature, programming and preview status of
remote programming, shutdown and voltage, current and OVP setpoints.
overvoltage protection, status and

Features
♦ Output Voltage
Voltage ranges from 0-8 VDC to ♦ Remote Programming ♦ Software
0-600 VDC; current levels from • Selectable remote programming LabVIEW® driver for M9C/M85 can
1.7A to 350A for voltage, current and OVP be downloaded at no cost at
• Optional internal IEEE-488/RS 232 www.sorensen.com/support/
♦ Power Density Interface Card with voltage and downloads.cfm
• 1 kW of power in a 19 lb. package current readback and adjustable
only 1.75 inches high OVP (Option M9C) ♦ Regulatory Compliance
• 3 kW of power in a 33 lb. package • Optional isolated analog CE Mark, UL 1012, FCC Part 15
only 3.5 inches high programming (Option M51) Class A and CSA 22.2 #220 (1 kW)
• Optional multichannel slave
♦ Input Voltage interface (Option M85) ♦ 5 Year Warranty
• 1 kW: 100-132 VAC, single phase,
or 200-250 VAC, single phase ♦ Regulation
47-63 Hz (other inputs available) • Line regulation: 0.1%
• 3 kW: 190-250 VAC, three phase • Load regulation: 0.1%
or 200-250 VAC, single phase
47-63 Hz (2.5 kW max with single
phase input; other inputs available)

Sorensen • 858/450-0085 • 800/525-2024 • Fax: 858/458-0267 • 9250 Brown Deer Road • San Diego • California • 92121-2294 • www.sorensen.com • E-mail: sales@sorensen.com 19
elg0430.qxd 2/22/01 9:55 PM Page 20

OUTPUT INPUT Analog Programming Linearity: ±1%


Analog Programming Accuracy: ±5%
Voltage and Current Voltage and Frequency Software: LabVIEW® driver for M9C/M85,
programs can be downloaded at no cost at
1 kW Model Voltage Current 1 kW: 200-250 VAC, single phase, 8.5A
www.sorensen.com/support/downloads.cfm
DCS 8-125E 0-8 0-125 typical, 47-63 Hz; or 100-132 VAC, single
DCS 20-50E 0-20 0-50 phase, 15A typical, 47-63 Hz, internal Regulatory Compliance: CE Mark
DCS 33-33E 0-33 0-33 jumper selectable (see M1 option) (1 kW only)
DCS 40-25E 0-40 0-25
3 kW: 190-250 VAC, three phase, 14A Dimensions
DCS 50-20E 0-50 0-20
typical, 47-63 Hz; or 200-250 VAC, single
DCS 60-18E 0-60 0-18 1 kW: 1U or 1.75” (44 mm) H x
phase, 26A typical, 47-63 Hz
DCS 80-13E 0-80 0-13 19” (482 mm) W x 17.5” (444 mm) D
DCS 150-7E 0-150 0-7 Note: Maximum power output of 3 kW supplies
must be limited to 2.5 kW for single phase input 3 kW: 2U or 3.5” (88 mm) H x
DCS 300-3.5E 0-300 0-3.5 19” (482 mm) W x 17.5” (444 mm) D
DCS 600-1.7E 0-600 0-1.7 Soft Start: Line current is lower than full
load peak value during turn-on or power Weight
3 kW Model Voltage Current
DCS 8-350 0-8 0-350 application after restart 1 kW: 19 lbs. ( 8.62 kg)
DCS 12-250 0-12 0-250 3 kW: 33 lbs. (15 kg)
DCS 20-150 0-20 0-150 GENERAL
DCS 40-75 0-40 0-75 Shipping Weight
DCS 55-55 0-55 0-55 Operating Temperature: 0°C to 50°C 1 kW: 24 lbs. (10.89 kg)
DCS 60-50 0-60 0-50 (no derating), 50°C to 70°C (derate 2%/°C
DCS 80-37 0-80 0-37 above 50°C) 3 kW: 42 lbs. (19 kg)
DCS 150-20 0-150 0-20 Storage Temperature: -55°C to 85°C
Voltage Resolution: 0.02% Humidity Range: 0 to 80% RH,
OPTIONS & ACCESSORIES
Ripple (mV RMS or P-P): See table non condensing M1: Factory configured for 115 VAC input
Regulation (Line or Load) Meter Accuracy: 1% of full scale + 1 count (1 kW units only)

Voltage: 0.1% Max. Voltage Differential from Output M9C*: Internal IEEE-488/RS 232 Interface
to Safety Ground M13: Locking shafts (front panel
Current: 0.1%
1 kW: 150 VDC potentiometers)
Transient Response: Typically recovers in
<1 ms to 1% of steady-state output voltage 3 kW: 150 VDC M32: Master/slave cable configured for two
(within 1% of Vmax) for 70-100% or or more units
Remote Start/Stop and Interlock: TTL
100-70% load change. 500 µs typical compatible input or 12-250 VAC M33: Replace input connector with terminal
Stability: ±0.05% of maximum voltage or (12-130 VDC) or a contact closure block (3 kW only)
current over 8 hours after 30 minute warm- Cooling: Internal fan, overtemperature M51: Isolated analog programming control
up time at fixed line, load and temperature shutdown at internal heat sink temperature of either the output current or voltage using
Efficiency: See table of 90°C analog signals that can be biased up to 60V
relative to the supply’s return line
Temperature Coefficient: 0.02%/°C of Remote Sense: The maximum allowed
maximum output voltage; 0.03%/°C of sense line drop is 1V (0.5V on the M85*: Multichannel slave interface
maximum output current DCS 8-125E model) * See digital programming discussion on page 49.
Remote Programming: External jumper via
rear panel connector J3
Overvoltage Protection: Crowbar type
adjustable from 5-110% of rated output
using front panel control (local or remote
program selectable via J3 jumper)

20 Sorensen • 858/450-0085 • 800/525-2024 • Fax: 858/458-0267 • 9250 Brown Deer Road • San Diego • California • 92121-2294 • www.sorensen.com • E-mail: sales@sorensen.com
elg0430.qxd 2/22/01 9:55 PM Page 21

Programming Constants
Output Power Constant Voltage Mode*
Combined Voltage Voltage Mode
Temp. Coeff.
Regulation Transient Drift
Model Current Line and Voltage
Voltage Ripple Noise Response % Vmax
ADC %/°C (Typ) Ohms/V V/V
VDC Load % (RMS)** (P-P) Time (Typ)
@ 50°C
µs (Typ)
DCS 8-125E 0-8 0-125 0.2 10 mV 100 mV 500 0.02 0.05 6.25
DCS 8-350 0-8 0-350 0.2 15 mV 100 mV 1000 0.02 0.05 625
DCS 12-250 0-12 0-250 0.2 10 mV 100 mV 1000 0.02 0.05 416.7
DCS 20-50E 0-20 0-50 0.2 10 mV 100 mV 500 0.02 0.05 250
DCS 20-150 0-20 0-150 0.2 10 mV 100 mV 1000 0.02 0.05 250
DCS 33-33E 0-33 0-33 0.2 10 mV 100 mV 500 0.02 0.05 151.5
DCS 40-25E 0-40 0-25 0.2 10 mV 100 mV 500 0.02 0.05 125
DCS 40-75 0-40 0-75 0.2 20 mV 100 mV 1000 0.02 0.05 125 0-10V =
0-100% V0
DCS 50-20E 0-50 0-20 0.2 20 mV 100 mV 500 0.02 0.05 100
or
DCS 55-55 0-55 0-55 0.2 20 mV 100 mV 1000 0.02 0.05 90.9
0-5V =
DCS 60-18E 0-60 0.18 0.2 20 mV 100 mV 500 0.02 0.05 83 0-100% V0
DCS 60-50 0-60 0-50 0.2 20 mV 100 mV 1000 0.02 0.05 83
DCS 80-13E 0-80 0-13 0.2 20 mV 100 mV 500 0.02 0.05 62.5
DCS 80-37 0-80 0-37 0.2 20 mV 100 mV 1000 0.02 0.05 62.5
DCS 150-7E 0-150 0.7 0.2 30 mV 200 mV 500 0.02 0.05 33.3
DCS 150-20 0-150 0-20 0.2 30 mV 200 mV 1000 0.02 0.05 33.3
DCS 300-3.5E 0-300 0-3.5 0.2 40 mV 200 mV 500 0.02 0.05 16.67
DCS 600-1.7E 0-600 0-1.7 0.2 100 mV 500 mV 500 0.02 0.05 8.33

Programming
Constant Current Mode* Temp. Current Constants, Current Input Current, A Nominal
Coeff. Drift Mode Efficiency %
Model Case
Regulation Ripple %/°C %I0 Max. (Typ.)
(Typ.) (Typ.) Ohms/A 230V Single 208V Three
Line and Load (RMS)** V/A
Phase Phase
% Combined mA
DCS 8-125E 0.2 160 0.03 0.05 40 8.5 N/A 82 I
DCS 8-350 0.2 870 0.03 0.05 14.3 24 13 82 II
DCS 12-250 0.2 400 0.03 0.05 20 26 14 82 II
DCS 20-50E 0.2 25 0.03 0.05 100 8.5 N/A 82 I
DCS 20-150 0.2 100 0.03 0.05 33.3 26 14 82 II
DCS 33-33E 0.2 10 0.03 0.05 151.5 8.5 N/A 82 I
DCS 40-25E 0.2 7 0.03 0.05 200 8.5 N/A 82 I
DCS 40-75 0.2 75 0.03 0.05 66.7 0-10V= 26 14 86 II
0-100% I0
DCS 50-20E 0.2 7 0.03 0.05 250 8.5 N/A 86 I
or
DCS 55-55 0.2 40 0.03 0.05 90.9 0-5V= 26 14 82 II
DCS 60-18E 0.2 6 0.03 0.05 277.8 0-100% I0 8.5 N/A 86 I
DCS 60-50 0.2 33 0.03 0.05 100 26 14 86 II
DCS 80-13E 0.2 4 0.03 0.05 384.6 8.5 N/A 82 I
DCS 80-37 0.2 20 0.03 0.05 135 26 14 86 II
DCS 150-7E 0.2 2 0.03 0.05 714.3 8.5 N/A 82 I
DCS 150-20 0.2 10 0.03 0.05 250 26 14 86 II
DCS 300-3.5E 0.2 1 0.03 0.05 1428.6 8.5 N/A 82 I
DCS 600-1.7E 0.2 1 0.03 0.05 2941 8.5 N/A 82 I
* Typical resolution is 0.02% ** RMS ripple typical from 20 Hz to 300 kHz

Sorensen • 858/450-0085 • 800/525-2024 • Fax: 858/458-0267 • 9250 Brown Deer Road • San Diego • California • 92121-2294 • www.sorensen.com • E-mail: sales@sorensen.com 21
elg0430.qxd 2/22/01 9:55 PM Page 22

Case I Case II
1.10 1.10
(28) (28)

17.52 17.52
(445) (445)

1.00 Top View 1.00 Top View


(25)
1.00 19.00 1.00
(25) 19.00
(25) (482) (482)
3.00 3.46
(76) (87)
1.25 1.72
(31) Front View (43) Front View
16.90 16.90
(429) (429)

Rear View Rear View


Dimensions in inches (millimeters)

J3 Program and Sense


Options & Accessories 1 90-250 VAC Remote Shutdown 14 TTL Shutdown
2 Shutdown Return 15 +12 VDC
Input Voltage Options
3 OVP Program 16 1 mA Current Source (OVP)
M1 Factory configured for 115 VAC input (1 kW only)
4 Remote/Local Status Indicator 17 OVP Indicator
Remote Interface Options
M9C Internal IEEE-488/RS 232 interface 5 Mode Status Indicator 18 Thermal S/DN Status
M13 Locking shafts (front panel potentiometers) 6 Ground 19 0-5V Voltage Monitor
M32 Master/slave cable configured for two or more units 7 0-5V Current Monitor 20 Remote Voltage Select
M33 Replace input connector with terminal block (3 kW only) 8 Voltage Control 21 1 mA Current Source (V)
M51 Isolated analog programming control 9 Voltage Program Input 22 1 mA Current Source (I)
M85 Multichannel slave interface
10 Current Program Unit 23 Remote Current Select
11 Current Control 24 Return
12 Return Sense 25 POS Output (8-80V Models Only)
13 POS Sense (8-80V Models Only)

22 Sorensen • 858/450-0085 • 800/525-2024 • Fax: 858/458-0267 • 9250 Brown Deer Road • San Diego • California • 92121-2294 • www.sorensen.com • E-mail: sales@sorensen.com

You might also like