DEVELOPMENT PROJECT
PHASE 8
TURBOCOMPRESSOR TRAIN A
PRE-COOLERS
OPERATIONAL TEST PROCEDURE
SUB-SYSTEM 6004
COMMISSIONING
DOCUMENT NUMBER REVISION
/conversion/tmp/activity_task_scratch/637390635.doc
TOTALFINAELF OPERATIONAL TEST PROCEDURE TUNU 8
SUB-SYS: 6004 DESCR: Pre Coolers Train A LOCATION : NCP PAGE : 2 OF 11
DATE NAME AND
STEP TASK DESCRIPTION COMPLETED SIGNATURE
SUMMARY
There are 4 Gas Compressor Pre-Coolers per train tagged 5-A 0160
A/B/C/D (Train A) and 5-A 0170 A/B/C/D (Train B).
They are of the air-cooled forced draft design.
Each cooler can be stopped or started independently of each other, either
by local or remote signals, and all are equipped with independent
vibration switches
/conversion/tmp/activity_task_scratch/637390635.doc
TOTALFINAELF OPERATIONAL TEST PROCEDURE TUNU 8
SUB-SYS: 6004 DESCR: Pre Coolers Train A LOCATION : NCP PAGE : 3 OF 11
DATE NAME AND
STEP TASK DESCRIPTION COMPLETED SIGNATURE
1 TEST SUMMARY
1.1 AIMS OF OPERATIONAL TEST
The object of this OTP is to prove the start / stop logic of the
Compressor Pre-Cooler Train A, No 5-A 0160 to the PCS and
Electrical MCC’s.
To ensure fans stop when the vibration protection switches are activated
None
/conversion/tmp/activity_task_scratch/637390635.doc
TOTALFINAELF OPERATIONAL TEST PROCEDURE TUNU 8
SUB-SYS: 6004 DESCR: Pre Coolers Train A LOCATION : NCP PAGE : 4 OF 11
DATE NAME AND
STEP TASK DESCRIPTION COMPLETED SIGNATURE
Mechanical 1
Electrical 1
Start-up 1
1 day
None
/conversion/tmp/activity_task_scratch/637390635.doc
TOTALFINAELF OPERATIONAL TEST PROCEDURE TUNU 8
SUB-SYS: 6004 DESCR: Pre Coolers Train A LOCATION : NCP PAGE : 5 OF 11
DATE NAME AND
STEP TASK DESCRIPTION COMPLETED SIGNATURE
3 TEST REQUIREMENTS
3.1 PRECOMMISSIONING ACHIEVEMENTS
/conversion/tmp/activity_task_scratch/637390635.doc
TOTALFINAELF OPERATIONAL TEST PROCEDURE TUNU 8
SUB-SYS: 6004 DESCR: Pre Coolers Train A LOCATION : NCP PAGE : 6 OF 11
DATE NAME AND
STEP TASK DESCRIPTION COMPLETED SIGNATURE
4 TEST PREPARATION
None
None
/conversion/tmp/activity_task_scratch/637390635.doc
TOTALFINAELF OPERATIONAL TEST PROCEDURE TUNU 8
SUB-SYS: 6004 DESCR: Pre Coolers Train A LOCATION : NCP PAGE : 7 OF 11
DATE NAME AND
STEP TASK DESCRIPTION COMPLETED SIGNATURE
3 Check that the Pre-Cooler Fan 5-A 0160 A cannot be started from
the local START button PB 0160 A1
5 Reset the local STOP button PB0160 A2 Check that the FAULT
alarm XA 0160 A1 is cleared
7 Start the Pre-Cooler Fan 5-A 0160 A from the local START
PB 0160 A1 Check that the Pre-Cooler Fan starts OK.
9 Check the Fan is rotating in the correct direction. Check the Fan
condition for a few minutes, while checking the fan blades tip
clearance with housing.
13 Stop Cooling Fan using the local STOP Push Button PB0160 A2.
When Cooling Fan has stopped reset the STOP push button.
14 Start the pre-cooler Fan 5-A 0160 A using the local Push Button
PB0160 A1. Simulate a vibration by hammering the structure
supporting the cooler until the VSHH 0161 A trips
/conversion/tmp/activity_task_scratch/637390635.doc
TOTALFINAELF OPERATIONAL TEST PROCEDURE TUNU 8
SUB-SYS: 6004 DESCR: Pre Coolers Train A LOCATION : NCP PAGE : 8 OF 11
DATE NAME AND
STEP TASK DESCRIPTION COMPLETED SIGNATURE
3 Check that the Pre-Cooler Fan 5-A 0160 B cannot be started from
the local START button PB 0160 B1
5 Reset the local STOP button PB0160 B2 Check that the FAULT
alarm XA 0160 B1 is cleared
7 Start the Pre-Cooler Fan 5-A 0160 B from the local START
PB 0160 B1 Check that the Pre-Cooler Fan starts OK.
9 Check the Fan is rotating in the correct direction. Check the Fan
condition for a few minutes, while checking the fan blades tip
clearance with housing.
/conversion/tmp/activity_task_scratch/637390635.doc
TOTALFINAELF OPERATIONAL TEST PROCEDURE TUNU 8
SUB-SYS: 6004 DESCR: Pre Coolers Train A LOCATION : NCP PAGE : 9 OF 11
DATE NAME AND
STEP TASK DESCRIPTION COMPLETED SIGNATURE
13 Stop Cooling Fan using the local STOP Push Button PB0160 B2.
When Cooling Fan has stopped reset the STOP push button.
14 Start the pre-cooler Fan 5-A 0160 B using the local Push Button
PB0160 B1. Simulate a vibration by hammering the structure
supporting the cooler until the VSHH 0161 B trips
3 Check that the Pre-Cooler Fan 5-A 0160 C cannot be started from
the local START button PB 0160 C1
5 Reset the local STOP button PB0160 C2 Check that the FAULT
alarm XA 0160 C1 is cleared
7 Start the Pre-Cooler Fan 5-A 0160 C from the local START
PB 0160 C1 Check that the Pre-Cooler Fan starts OK.
/conversion/tmp/activity_task_scratch/637390635.doc
TOTALFINAELF OPERATIONAL TEST PROCEDURE TUNU 8
SUB-SYS: 6004 DESCR: Pre Coolers Train A LOCATION : NCP PAGE : 10 OF 11
DATE NAME AND
STEP TASK DESCRIPTION COMPLETED SIGNATURE
9 Check the Fan is rotating in the correct direction. Check the Fan
condition for a few minutes, while checking the fan blades tip
clearance with housing.
13 Stop Cooling Fan using the local STOP Push Button PB0160 C2.
When Cooling Fan has stopped reset the STOP push button.
14 Start the pre-cooler Fan 5-A 0160 C using the local Push Button
PB0160 C1. Simulate a vibration by hammering the structure
supporting the cooler until the VSHH 0161 C trips
3 Check that the Pre-Cooler Fan 5-A 0160 D cannot be started from
the local START button PB 0160 D1
5 Reset the local STOP button PB0160 D2 Check that the FAULT
alarm XA 0160 D1 is cleared
/conversion/tmp/activity_task_scratch/637390635.doc
TOTALFINAELF OPERATIONAL TEST PROCEDURE TUNU 8
SUB-SYS: 6004 DESCR: Pre Coolers Train A LOCATION : NCP PAGE : 11 OF 11
DATE NAME AND
STEP TASK DESCRIPTION COMPLETED SIGNATURE
7 Start the Pre-Cooler Fan 5-A 0160 D from the local START
PB 0160 D1 Check that the Pre-Cooler Fan starts OK.
9 Check the Fan is rotating in the correct direction. Check the Fan
condition for a few minutes, while checking the fan blades tip
clearance with housing.
13 Stop Cooling Fan using the local STOP Push Button PB0160 D2.
When Cooling Fan has stopped reset the STOP push button.
14 Start the pre-cooler Fan 5-A 0160 D using the local Push Button
PB0160 D1. Simulate a vibration by hammering the structure
supporting the cooler until the VSHH 0161 D trips
/conversion/tmp/activity_task_scratch/637390635.doc