7 - MAINTENANCE

Lubricants and coolants


Recommended fluids and application International specification Approximate quantity
Engine fuel Diesel 210.00 L (55.48 US gal)
Engine oil SAE 15W40, API CI-4 PLUS 16.0 L (4.2 US gal)
Hydraulic system oil CASE IH AW68 HYDRAULIC FLUID 130.00 L (34.34 US gal)
Coolant Ethylene glycol + Dm water premixed 34.0 L (9.0 US gal)
AKCELA, multipurpose grease,
Grease fittings and bearings 251H,EP, NLGI NO. 2 MULTI -PURPOSE —
LITHIUM EP GREASE
CASE IH AKCELA GEAR LUBE 135
Basecutter gear box oil 6.00 L (1.59 US gal)
H EP 85W-140
CASE IH AKCELA GEAR LUBE 135
Chopper gearbox oil 5.00 L (1.32 US gal)
H EP 85W-140
CASE IH AKCELA GEAR LUBE 135
Rear wheel hub oil 1.20 L (0.32 US gal)
H EP 85W-140
CASE IH AKCELA AW100
Splitter gearbox oil 1.25 L (0.3 US gal)
HYDRAULIC FLUID

Physical properties of the of the hydraulic oil


Appearance Clear and bright
Density at 15 °C (IP160) 0.880 - 0.890 (Normally 0.882)
Viscosity at 40 °C cSt (IP 71) 66 - 100
Viscosity at 100 °C cSt (IP 71) 11 minimum
Viscosity on maximum working temperature 13 minimum
Viscosity Index (IP 226) 150 minimum
% Mass Alkyl Zinc 0.04
Aniline Point °C (IP2) 100 minimum
Demulsibility (Grade ISO 68 - ASTM D1401) 40/37/3 (30) at 54 °C
Demulsibility (Grade ISO 100 - ASTM D1401) 40/37/3 (30) at 82 °C
Filterability (Denison TP-02100) Pass
Protects against rust ( ASTM D665). Use distilled water
Use synthetic sea water
Oxidation stability 2500 minimum. Time for 2.0 mg KOH/gm ASTM D943
Pour Point °C (IP 15) -35 maximum
Flash Point 190 minimum - closed (IP34) °C. 210 minimum - open
(IP35) °C.
Fire Point °C (IP 35) 240 minimum
Air Release (IP 313) 660 s maximum
Viscosity after 1.000 h - KV at 100 °C 10.5 cSt minimum

Specifications of the air conditioner


All machines are now fitted with A/C compressors de- therefore does not contain the ozone-depleting element
signed for the use of R134A refrigerant, and Sanden PAG chlorine, so it has an ODP (ozone-depleting potential) of
SP20 Lubricant. zero. It does have a global-warming potential but it is less
than 10% of that of R12.
R134A refrigerant (tetrafluoroethane - CH2FCF3).
Contact an authorized distributor to clean the A/C system
R134A is a stable, colorless, non-toxic, non-flammable, once a year.
liquefied gas with a faint ethereal odor. It is an HFC and

Refrigerant Ozone-depleting potential Greenhouse effect


R11 1 1
R12 1 3.0
R134A 0 0.29
Ternary mixture (HCFC22 +
0.02 0.15
HFC152A + HCFC124)

7-4