Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Construction Progress BD-001 (Bulding Work Package 1) Inv-003 (ISH 116, SHL-085, SHL-054 & SHL-083)

Area

No. Item or Work Description BOQ Volume Unit Total


ISH-116 SHL-085 SHL-054 SHL-083 SHL-053 K-002

I DIRECT COST

A.1 PC PILES

1 PILE HEAD TREATMENT (D500mm) 345,00 EA - - - - -


2 PILE HEAD TREATMENT (D600mm) 294,00 EA - - - - -

A.2 EARTH WORK

1 EXCAVATION 8.784,69 M3 - - - - - 192 192,20

2 BACKFILLING / REUSED SOIL 4.195,97 M3 113 - - - - 112,96

3 BACKFILLING (MANUAL) / REUSED SOIL 50,00 M3 -

4 SUB-BASE(SAND) 40,00 M3 -

5 COMPACTED STRUCTURAL FILL / CRUSHED STONE 1.241,73 M3 - -

6 COMPACTED STRUCTURAL FILL / BORROW SOIL 70,00 M3 -

7 STRUCTURAL FILL / PURCHASED SOIL 871,50 M3 -

8 DISPOSAL 4.918,19 M3 - - - - - -

9 SAND FILLING 637,91 M3 -

10 GRAVELLING FILLING 61,78 M3 -

11 PE SHEET (VAPOR BARRIER) 4.829,16 M2 - - - - - 42 41,88

A.3 CONCRETE WORKS

CONCRETE - Blinding Concrete / Min. 14MPa at 28 Days


Cylinder Strength in accordance with ASTM C39/C39M, ASTM
1 159,71 M3 10,21 - 0,4 - - 1,8 12,46
C150 Type I
Including form work(Installation & Removal)

CONCRETE - [AG] Min. 28 MPa at 28 Days Cylinder Strength in


2 1.463,35 M3 14,52 - 31 - 45,30
accordance with ASTM C39/C39M, ASTM C150 Type I

CONCRETE - [UG] Min. 28 MPa at 28 Days Cylinder Strength in


3 3.722,60 M3 73,34 9,56 3 85,66
accordance with ASTM C39/C39M, ASTM C150 Type V

FORM WORKS - 3 Times, Fair Face For Above Ground


4 11.370,16 M2 434,83 24 458,49
Scaffolding and support included

FORM WORKS - 4 Times, General For Under Ground


5 5.920,91 M2 395,66 9,60 38 443,15
Scaffolding and support included

6 REINFORCEMENT 603,91 TON 30,79 29,14 1 - 13 3 73,48

7 FAIR FACE TREATMENT 3.611,30 M2 -

8 ROUGH SURFACE FINISH + GROOVE 309,00 M2 -

PRECAST CONCRETE COVER - Removable Type Precast


Concrete Cover - THK. 100 mm
9 0,33 M2 -
Included Cover Handle and Waterproofing Sealant.
Re-bar & Concrete supplied by Contractor
EXPANSION JOINTS - For Wall of Building Speration,
10 Thk.=75mm, AL. Flashing(Both Side) including retaed works 65,40 M -
(Filler & Sealant).
EXPANSION JOINTS - For Floor of Building Speration,
11 Thk.=75mm, AL. Flashing(Both Side) including retaed works 45,58 M -
(Filler & Sealant).
EXPANSION JOINTS - FOR Roof of Building Speration,
12 Thk.=75mm, AL. Flashing(Both Side) including retaed works 30,82 M -
(Filler & Sealant).
ISOLATION JOINT (SEPARATION JOINT) - Thk.= 13mm, For
13 1.916,54 M -
Walkway, Stoop, Ramp, SOG
Area

No. Item or Work Description BOQ Volume Unit Total


ISH-116 SHL-085 SHL-054 SHL-083 SHL-053 K-002

ISOLATION JOINT (SEPARATION JOINT) - Thk.= 20mm, For


14 226,00 M -
Slab & Equipment Foundation

EXPANSION JOINT - THK. 13 mm x 13mm Joint Sealant (Two-


component polysulfide)
15 THK. 13 mm x 187mm (D) Premolded Joint Filler conform to 114,41 M -
ASTM D1752, Type 1 or Equal
Plane Dowel bar D19x350@300mm w/ PVC Sleeve (seal end)

CONTROL JOINT - Saw Cut : 6 mm x 20 mm w/ Joint Sealant


16 85,07 M -
for S.O.G. or Paving .
EXPANSION JOINTS - For parapet, At @25,000mm
17 THK.12 Premould Filler, Side Finish With Sealant 89,00 M -
Chamfering (20x20, Both Side)
COTRACTION JOINT - For parapet, At @6,000mm
18 368,00 M -
10(W)x15(D), Saw Cut Joint (Both Side) With Sealant
GROOVE CUT - For Parapet (Waterproofing)
19 423,60 M -
20x15, By Plastic or Wooden Bead
SCORED JOINT - For Walkway
20 361,00 M -
Depth : 25mm, Saw Cut
BITUMINOUS COATING - Concrete Surface under ground(FDN,
21 Column, Grade Beam & Trench) 6.474,23 M2
Coats of an approved Bitumen-Latex Emulsion Paint
BITUTHENE MEMBRANES - For External Waterpoofing [Sheet
Type] / In Foundation Underside
22 3.220,93 M2
Bituminous self adhesive membrane with mineral finish
“Bitushield” by Servicised or approved equal.

23 WATER STOP - Width = 9" , PVC 334,78 M -

WATER STOP - 20mm x 5mm Hydrophilic Type. ADEKA MC-


24 83,80 M -
2005T or Equal

25 WELDED WIRE FABRIC - Steel wire fabric M10x150x150 722,00 M2 -


Area

No. Item or Work Description BOQ Volume Unit Total


ISH-116 SHL-085 SHL-054 SHL-083 SHL-053 K-002

A.4 BLOCK WORKS

EXTERIOR MASONRY WALL - THK. 230 mm Solid Brick / Block,


ASTM C129 or BS EN 771-3.
Cement or Cement - lime mortar / Anchors and galvanized
expanded
metal joint reinforcement at every 2 horizontal brick / blodck
1 2.482,87 M2 -
course.
Including control joint at maximum 9,000 mm spacing
Including lintels, reinforcement, openings, thresholds, sills,
galvanised and zinc coated steel ties and anchor, damp-proof
course, etc
EXTERIOR MASONRY WALL - THK. 110 mm Solid Brick / Block,
ASTM C129 or BS EN 771-3.
Cement or Cement - lime mortar / Anchors and galvanized
expanded
metal joint reinforcement at every 2 horizontal brick / blodck
2 36,00 M2 -
course.
Including control joint at maximum 9,000 mm spacing
Including lintels, reinforcement, openings, thresholds, sills,
galvanised and zinc coated steel ties and anchor, damp-proof
course, etc
ISOLATION JOINT (SEPARATION JOINT) - Thk.= 20mm, For
3 Between Brick and Conc (Both side) 1.400,00 M -
Both Side Finish With Filler, Sealant

A.5 PAINTING WORKS

ACRYLIC EMULSION PAINT (AEP) - EXTERNAL WALL


Weathershield Emulsion Painted on Fair Faced Concrete or
1 2.316,95 M2 -
Plaster Wall
Minimum 3 coats.
ACRYLIC EMULSION PAINT (AEP) - INTERNAL WALL
Interior Latex Eg-Shel Paint, Minimum 3 coats.
2 1st : Premium Wall & Wood Primer 1.528,09 M2 -
2nd : ProMar 200 1.6 Mils DFT
Manufactured by Sherwin Williams or approved equal
ACRYLIC EMULSION PAINT (AEP) - CEILING
Acrylic Emulsion Paints on Plaster or Fair Faced , Minimum 2
3 3.147,67 M2 -
Coats.
Acrylic latex primer + Acrylic latex

4 ACRYLIC EMULSION PAINT (AEP) - SKIRT, H=100MM 925,50 M -

EPOXY PAINT - INTERNAL WALL, Oil Resistant Epoxy Paint


5 For For Inside Wall of Transformer Area 220,00 M2 -
D.F.T : 300 microns
EPOXY PAINT - FLOOR, Oil Resistant Epoxy Paint For Floor of
6 Transformer Area 310,00 M2 -
D.F.T : 300 microns
EPOXY PAINT - FLOOR, CONCRETE ANTISKID
7 0,48 M2 -
D.F.T : 300 microns
ACID RESISTANT PAINT - FLOOR, Alkali/Acid Resistant Epoxy
8 Paint for Floor of Battery Room 1.094,92 M2 -
D.F.T : 300 microns
ACID RESISTANT PAINT - INTERNAL WALL, Alkali/Acid
9 Resistant Epoxy Paint for Wall of Battery Room 207,45 M2 -
D.F.T : 300 microns
ACID RESISTANT PAINT - CEILING, Alkali/Acid Resistant
10 Epoxy Paint for Ceiling of Battery Room 128,50 M2 -
D.F.T : 300 microns
ACID RESISTANT PAINT - SKIRT, H=100mm, Alkali/Acid
11 Resistant Epoxy Paint for SKIRT 50,00 M -
H=100MM of Battery Room
ANTI-DUST PAINT - FLOOR, Epoxy Paint (Dust Proof) - Raised
12 floor for FLOOR 577,41 M2 -
D.F.T : 300 microns
ANTI-DUST PAINT - WALL, Epoxy Paint (Dust Proof) - Raised
13 floor for Wall 70,00 M2 -
D.F.T : 300 microns
INTERIOR WALL PAINT ( for Plster & Masonry ) - Vinyl Acetate
14 Paint on Plaster Wall or Gypsum Board Wall. 2.556,26 M2 -
Minimum 2 coats.
EXTERIOR WALL PAINT - Fire proof Coating 2hr rated. (for
15 0,32 M2 -
MCR Exterior wall)

A.6 TILE WORKS

CERAMIC TILE - FLOOR W/ BEDDING, WIREMESH IF


1 60,44 M2 -
NECESSARY
CERAMIC TILE - WALL W/ BEDDING, WIREMESH IF
2 288,00 M2 -
NECESSARY
CERAMIC TILE - SKIRTING W/ BEDDING, WIREMESH IF
3 78,00 M -
NECESSARY

CONCRETE PAVER (WALK WAY) - 500mm X 500mm X 50mm


4 Conrete Tile for Ground Walkay. Including all works and materials 0,63 M2 -
for installation of Concrete Paver around building.
FLOOR TILES - Standard Grade Polished Ceramic Floor Tile in
accordance with SNI 13006-2010.
Approx. Size 400 mm x 400 mm.
5 51,60 M2 -
Laid with commercial Portland cement type grout, American
Olean products or approved equal
Including Mortar Bed up to 50 mm Thickness.
FLOOR TILES - Heavy Duty Ceramic Tile 600 x 600
6 Laid with Cement and Sand Mortar or Gluing-on with Adhesive. 0,70 M2 -
Including Mortar Bed up to 50 mm Thickness.
Area

No. Item or Work Description BOQ Volume Unit Total


ISH-116 SHL-085 SHL-054 SHL-083 SHL-053 K-002

FLOOR TILES - Homogeneous Tile 600 x 600


7 Laid with Cement and Sand Mortar or Gluing-on with Adhesive. 0,87 M2 -
Including Mortar Bed up to 50 mm Thickness.

ACID - RESISTANT FLOOR TILE - Heavy Duty Floor Tile (Acid


Resistant), BS EN ISO 10545 or ASTM C 650
Approx. Size 600 x 600 Thickness as per Manufacturer's
8 Standards. 0,61 M2 -
Laid with Acid Resistant Mortar or Gluing-on Epoxy Grout and
Joint.
Including Mortar Bed up to 50 mm Thickness.

WALL TILES
9 0,65 M2 -
(Wainscot Faucet Side)

TILE BASE - Ceramic Tile Base


100 mm Height w/ 8 mm ~12 mm Thickness as per
Manufacturer's
10 70,32 M2 -
Standard. The size shall match with floor tiles.
Laid with Cement and Sand Mortar or Gluing-on with Adhesive.
Including Base Mortar up to 20 mm Thickness.
TILE BASE - Heavy Duty Ceramic Tile Base
100 mm Height w/ 8 mm ~12 mm Thickness as per
Manufacturer's
11 0,49 M2 -
Standard. The size shall match with floor tiles.
Laid with Cement and Sand Mortar or Gluing-on with Adhesive.
Including Base Mortar up to 20 mm Thickness.
TILE BASE - Homogeneous Tile Base
100 mm Height w/ 8 mm ~12 mm Thickness as per
Manufacturer's
12 0,68 M2 -
Standard. The size shall match with floor tiles.
Laid with Cement and Sand Mortar or Gluing-on with Adhesive.
Including Base Mortar up to 20 mm Thickness.
TILE BASE - Heavy Duty Ceramic Tile Base (Acid Resistant)
100 mm Height w/ 8 mm ~12 mm Thickness as per
Manufacturer's
13 0,89 M2 -
Standard. The size shall match with floor tiles.
Laid with Cement and Sand Mortar or Gluing-on with Adhesive.
Including Base Mortar up to 20 mm Thickness.
LAVATORY COUNTER TOP - THK. 20 mm Marble Lavatory
Counter Top
14 7,41 M2 -
W = 850 mm
Including all accessories for Support.

A.7 WATERPROOFING WORKS

1 LIQUID WATERPROOFING - INTERNAL FLOOR AREA 13,45 M2 -

LIQUID WATERPROOFING - INTERNAL WALL AREA, UP TO


2 46,64 M2 -
1.8M

A.8 ROOF WORKS

ROOF SCREED - MIN. THK.50mm W/ Slope


1 For Roof Drainage 1.836,70 M2 -
Including Steel Trowel Finish, Expansion & Control Joint

2 WATERPROOFING MEMBRANE 1.867,70 M2 -

3 POLYSTYRENE FOAM INSULATION 1.836,70 M2 -

4 P.E FILM - THK. 0.15mm Polythene sheeting 1.836,70 M2 -

5 CONCRETE TILE 257,00 M2 -

FLASHING FOR PARAPET - THK0.8 Galv. Steel Flashing,


H=300mm(Min.)
6 362,51 M -
For Conner Between Floor And Parapet
Including Fixing & Sealant

A.9 DOOR & WINDOW WORKS

1 STEEL DOOR 0,52 M2 -

2 STEEL DOOR / W PANIC BAR 7,00 M2 -

3 STEEL DOOR 6,14 M2 -

FIRE RATED STEEL DOOR - Fire Rate 1/3 Hour


Underwriters Laboratories (UL), Factory Mutual (FM) label, NFPA
4 80. 0,10 M2 -
STC rating of 38 or better.
Including all Hardwares
FIRE RATED STEEL DOOR - Fire Rate 1 Hour
Underwriters Laboratories (UL), Factory Mutual (FM) label, NFPA
5 80. 0,40 M2 -
STC rating of 38 or better.
Including all Hardwares
FIRE RATED STEEL DOOR - Fire Rate 1.5 Hour
Underwriters Laboratories (UL), Factory Mutual (FM) label, NFPA
6 80. 0,60 M2 -
STC rating of 38 or better.
Including all Hardwares
Area

No. Item or Work Description BOQ Volume Unit Total


ISH-116 SHL-085 SHL-054 SHL-083 SHL-053 K-002

FIRE RATED STEEL DOOR W/ PANIC BAR - Fire Rate 1/3 Hour
Underwriters Laboratories (UL), Factory Mutual (FM) label, NFPA
7 80. 0,80 M2 -
STC rating of 38 or better.
Including all Hardwares

FIRE RATED STEEL DOOR W/ PANIC BAR - Fire Rate 1 Hour


Underwriters Laboratories (UL), Factory Mutual (FM) label, NFPA
8 80. 0,60 M2 -
STC rating of 38 or better.
Including all Hardwares

FIRE RATED STEEL DOOR W/ PANIC BAR - Fire Rate 1.5 Hour
Underwriters Laboratories (UL), Factory Mutual (FM) label, NFPA
9 80. 46,10 M2 -
STC rating of 38 or better.
Including all Hardwares
BLAST RESISTANT DOOR W/ PANIC BAR - Design Pressure :
3 psi, Fire Rate 1 Hour
10 0,80 M2 -
- Including all Heavy duty Hardwares and Weatherstripping
accessories as per Manufacturer's Standards

ALUMINUM WINDOW - Minimum thickness 2.5 mm Extruded


Aluminum alloy w/ Anodic Fin. or
Organic Paint Fin.
Approx. Frame Depth 60 mm ~ 115 mm as per Manufacturer's
Standards.
11 Manufactured by YKK Window & Wall System or approved equal. 14,94 M2 -
Including all hardwares , weatherstripping and thermal barrier etc,
except glass.
A window system shall be withstand positive and negative wind
load as
calculated in accordance with applicable Code.

PAIR GLASS - THK. 22 mm Tempered Laminated Pair Glass


6.0 mm Tempered Laminated Glass ( 3+3, clear) + 10 mm Air
Space + 6.0 mm Tempered Laminated Glass ( 3+3, exterior side
12 14,00 M2 -
tinted gray).
U-factor shall be 0.65 minimum; SHGC shall be 0.25 or better.
Including Installation and all Accessories
TEMPERED GLASS - THK. 10 mm Tempered Glass
13 0,94 M2 -
Including Installation and all Accessories
STEEL LOUVER - INCLUDING BIRD SCREEN W/ AL. FRAME
14 2,00 M2 -
AND ALL ACCESSORIES.
VERTICAL BLIND - Window Roller Blinds ex “TOSO BLINDS” or
15 approved equal. 15,74 M2 -
T1-1029 B operated with Ball chain drive system
MASTER KEY SYSTEM - All locks for building, offices, gates,
doors, etc shall be keyed into a grand mater, master and sub-
16 1,00 L/S -
mastere-keyed locking system.
Including key cabinet

A.10 EXTERIOR/INTERIOR FINISH WORKS

1 SCREED 240,00 M2 -

2 RECESS FLOOR MAT 18,65 M2 -

3 RUBBER MAT 940,96 M2 -

4 ACOUSTIC TILED CEILING 525,52 M2 -

5 EXTERNAL PLASTER 2.196,19 M2 -

6 INTERNAL PLASTER 2.556,40 M2 -

7 RAISED FLOOR W/ VINYL TILE 0,09 M2 -

8 RAISED FLOOR W/ VINYL TILE 525,00 M2 -

9 GYPSUM BOARD WALL - Thk.12.0mm(2Ply), W/frame 0,71 M2 -

GALVANIZED STEEL SHEET W/FLASHING - For Wall, THK.


11 0.7mm 6.460,23 M2 -
Flashing: Pre-coated galvanized 0.8 mm thick,
GALVANIZED STEEL SHEET W/FLASHING - For Roof, THK.
12 0.7mm 3.261,61 M2 -
Flashing: Pre-coated galvanized 0.8 mm thick,
GUTTER - Eaves Gutter : THK. 1.2 mm Galvanized Steel w/
Fluorine Coating.
13 323,64 M -
Approximately Size : 300 mm (w) x 300 mm (h)
Including L- 40 x 40 x 5 @ 500 Support
BASKET STRAINER / GUTTER - For Shelter
14 64,00 EA -
Size & Type shall refer to Menufacturer Data
Area

No. Item or Work Description BOQ Volume Unit Total


ISH-116 SHL-085 SHL-054 SHL-083 SHL-053 K-002

AL. FLASHING COVER - for Opening Closing, THK. 0.8mm Galv


15 Steel w/PVDF coating 30,00 M2 -
Including Bolting & Sealant
STEEL TROWEL FINISH - Floor Concrete Surface Finishing w/
16 2.706,37 M2
Steel Trowel on Green Concrete.

17 STEEL TROWEL FINISH 0,06 M2 -

SUSPENDED ACOUSTIC CEILING SYSTEM


18 0,48 M2 -
(For MCR Control Room)

19 SUSPENDED GYPSUMBOARD CEILING SYSTEM 0,81 M2 -

20 ACOUSTICAL PANELS 0,71 M2 -

Operable Walls
21 0,26 M2 -
(Folding Partitions)

A.11 STEEL WORKS

GALVANIZED STEEL - JIS G3101 SS400 or Equivalent


1 3,00 TON -
Including Purlin&Girth and Connection Bolt

2 MISC. STEEL & EMBEDDED ITEMS 7,27 TON -

3 ANCHOR BOLT INSTALLATION 3,12 TON -

4 STEEL HANDRAIL - Hot Dip Galvanized W/Yellow paint (Safety) 168,05 M -

5 STEEL HANDRAIL (REMOVABLE) 20,00 M -

CAGED LADDER - Hot Dip Galvanized.


6 23,65 M -
JIS G3101 SS400 or Equivalent

GRATING - THK. 32MM, Hot Dip Galvanized.


7 SE-32 x 5 Serrated Top Surface Steel Grating (unit weight : 48.1 250,00 M2 -
kg/m2)
CHK'D PLATE - THK. 6.0 mm, ASTM A786/A786M Pattern 4 or
Pattern 5.
(Unit weight : 48. 8 kg/m2)
8 9,07 M2 -
Hot-dip galvanized in accordance with ASTM A123/A123M and/or
SNI 07-7033-2004
and Painting.

A.12 MISC. WORKS

ROOF DRAIN - FOR BUILDING, Φ=150, Cast Iron roof drain


1 26,00 EA -
w/Strainer

2 DOWNSPOUT - FOR BUILDING, Φ=150, GALV. STEEL. 213,43 M -

3 DOWNSPOUT - FOR SHELTER, Φ=150, GALV. STEEL. 571,30 M -

DOWNSPOUT - Unplastirized Poly Vinyl Chloride Pipe, from 125


4 mm up to Dia. 150 mm 0,34 M -
Including Strap & All Fixing Materials.
WATER COLLECTION BOX - THK. 1.2 mm Galvanized Steel w/
5 Paint. 17,00 EA -
Approximately Size : 250 mm (w) x 250 mm (d) x 300 mm (h)
CONCRETE SPLASH BLOCK - CONCRETE BLOCK TYPE, 450
mm (L) x 300 mm (W) x 150 mm (H)
6 38,00 EA -
Including Form work
Re-bar & Concrete, Supplied by Contractor

CHAIN LINK WIRE PANEL


7 469,33 M2 -
(for CABLE AREA , GAS CYLINDER SHELTER etc.,)
Area

No. Item or Work Description BOQ Volume Unit Total


ISH-116 SHL-085 SHL-054 SHL-083 SHL-053 K-002

8 CHAIN LINK WIRE FENCE for TRANSFORMER AREA 561,30 M2 -

STEEL BOLLARD - 6" Dia carbon steel pipe(h=1100mm) filled


with concrete, protection post painted with warning stripes.
9 Including foundation 31,00 EA -
Refer to Civil Standard drawing No. [26071-100-C0-000-00055,
FIXED GUARD POST (GP-1)]
BUILDING SIGNAGE - Approx. 1,200 mm (L) x 800 mm (H) -
THK. 6.0 mm, Melamine Plastic Laminate
10 9,00 EA -
Wall Mounted Type
Fire retardant and self-extinguishing
ROOM SIGNAGE - Approx. 100 mm (L) x 250 mm (H) -THK. 6.0
11 mm, Melamine Plastic Laminate 13,00 EA -
Fire retardant and self-extinguishing.

13 PVC PIPE 150,00 M -

SEPTIC TANK - Bio Septic tank FRP Type by Arch (for 10


14 6,00 EA -
persons-1ea)
VINYL COVED BASE - H = 100 rubber cove base,
17 101,99 M -
Manufactured by Roppe Rubber Corporation, or approved equal.
NON-SLIP - Stainless Steel, Aluminium or Brass Stair Non Slip w
18 120,00 M -
/ PVC Rubber
DIVIDING STRIP - THK. 1.8 mm - 50 mm x 20 mm Stainless
19 Steel 0,26 M -
Including Anchor Plates and Fixing Accessories.
TOILET CUBICLE W/ DOOR - Floor-mounted, overhead braced
type, using ‘Sierra Series 1092‘ solid color reinforced composite
finish as manufactured by Bobrick Corp. or approved equal.
20 0,68 M2 -
Including 600 mm (W) Clear Opening Cubicle Door w/ Indicator
Bolt,
Coat Hook etc, and all accessories.

22 MIRROR / W GLASS SHELF 9,00 EA -

23 SOAP DISPENSERS 6,00 EA -

24 GRAB BAR 9,00 EA -

TOILET and SHOWER ROOM ACCESSORIES - Shower Soap


25 Holder 6,00 EA -
Toto surface mounted soap dispenser
TOILET and SHOWER ROOM ACCESSORIES - Toilet Tissue
26 (Multi-Roll) Dispenser at each water closet, 6,00 EA -
Toto722 AE or approved equal
TOILET and SHOWER ROOM ACCESSORIES - Combination
Paper Towel Dispenser and Waste Receptacle
27 6,00 EA -
at each tollet room and two in each locker room
TOTO Indonesia or approved equal

TOILET and SHOWER ROOM ACCESSORIES - 125mm shelf at


28 6,00 EA -
each lavatory,TOTO Indonesia or approved equal
TOILET and SHOWER ROOM ACCESSORIES - Shower Curtain
29 13,60 M2 -
w/ Stainless Steel shower rod.
DEMOLITION OF CONCRETE - Including cutting, breaking,
30 5,00 M3 -
removal, disposal
CORE DRILLING - dia. 150mm on existing concrete, THK. 220
31 20,00 EA -
mm.

A.13 FURNITURE

1 DINING CHAIR 12,00 EA -

2 DINING TABLE 3,00 EA -

4 BENCH 0,71 M -

5 DESK 3,00 EA -

6 CHAIR 3,00 EA -

10 PANTRY CABINETS 7,13 M -

B.1 REVAMPING WORK

1 CUTTING AND BREAKING 9,00 LOT -


Area

No. Item or Work Description BOQ Volume Unit Total


ISH-116 SHL-085 SHL-054 SHL-083 SHL-053 K-002

2 DEMOLITION WORK FOR PAVING 208,00 M2 -

3 DEMOLITION WORK FOR CLADDING 500,00 M2 -

4 RE-INSTALLATION WORK FOR CLADDING (NEW) 500,00 M2 -

You might also like