I/O SIGNAL NETWORK NODE I/O DESCRIPTION I/O 1 FUNCTION 0 FUNCTION ENG. MIN ENG. MAX ENG. SETPOINTS REMARKS
ADDRESS TYPE ID No. LOCATION UNITS UNITS UNITS
10DQ0.0 NIS 24 vdc DP1 10 TD-BRAKE ON SOLENOID BRAKE APPLIED BRAKE RELEASED
10DQ0.1 NIS 24 vdc DP1 10 TD-ROTATE RIGHT SOLENOID TD ROTATES RIGHT TD STOPS
10DQ0.2 NIS 24 vdc DP1 10 TD-ROTATE LEFT SOLENOID TD ROTATES LEFT TD STOPS
10DQ0.3 NIS 24 vdc DP1 10 TD-IBOP CLOSE SOLENOID IBOP CLOSED LAST STATE
10DQ0.4 NIS 24 vdc DP1 10 TD-TORQUE WRENCH SOLENOID RLA JOGS, SHOT PIN ENGAGES, TORQUE WRENCH CLAMPS TORQUE WRENCH RELEASE
10DQ0.5 NIS 24 vdc DP1 10 TD-LINK TILT EXTEND SOLENOID LINK TILT MOVES TO “EXTEND” POSITION OR FLOATS LINK TILT STOPS
10DQ0.6 NIS 24 vdc DP1 10 TD-LINK TILT DRILL SOLENOID LINK TILT MOVES TO “DRILL” POSITION OR FLOATS LINK TILT STOPS
10DQ0.7 NIS 24 vdc DP1 10 TD-LINK TILT FLOAT SOLENOID LINK TILT MOVES TO “FLOAT” POSITION OR FLOATS LINK TILT STOPS
10DQ1.0 NIS 24 vdc DP1 10 TD-STAND JUMP SOLENOID COUNTER BALANCE CYLINDERS RETRACT COUNTER BALANCE CYLINDERS EXTENDS
10DQ1.1 NIS 24 vdc DP1 10 TD-Bx ELEVATOR OPEN SOLENOID Bx ELEVATOR OPEN Bx ELEVATOR ARMED OR CLOSED
10DQ1.2 NIS 24 vdc DP1 10 TD-Bx ELEVATOR CLOSE SOLENOID Bx Elevator CLOSED Bx ELEVATOR ARMED OR OPEN
10DQ1.3 NIS 24 vdc DP1 10 TD-FRAME DOLLY EXTEND SOLENOID FRAME DOLLY EXTENDS LAST STATE
10DQ1.4 NIS 24 vdc DP1 10 TD-FRAME DOLLY RETRACT SOLENOID FRAME DOLLY RETRACTS LAST STATE
I/O SIGNAL NETWORK NODE I/O DESCRIPTION I/O 1 FUNCTION 0 FUNCTION ENG. MIN ENG. MAX ENG. SETPOINTS REMARKS
ADDRESS TYPE ID No. LOCATION UNITS UNITS UNITS
10DQ1.5 NIS 24 vdc DP1 10 SPARE - -
10DQ1.6 NIS 24 vdc DP1 10 SPARE - -
10DQ1.7 NIS 24 vdc DP1 10 SPARE - -
10DQ8.0 NIS 24 vdc DP1 10 TD-CRT SLIPS UP SOLENOID SLIPS UP SLIPS DOWN
10DQ8.1 NIS 24 vdc DP1 10 TD-CRT ELEVATOR OPEN SOLENOID ELEVATOR OPEN ELEVATOR ARMED OR CLOSED
10DQ8.2 NIS 24 vdc DP1 10 TD-CRT LINK TILT EXTEND SOLENOID LINK TILT MOVES TO “EXTEND” POSITION OR FLOATS LINK TILT STOPS
10DQ8.3 NIS 24 vdc DP1 10 TD-CRT LINK TILT DRILL SOLENOID LINK TILT MOVES TO “DRILL” POSITION OR FLOATS LINK TILT STOPS
10DQ8.4 NIS 24 vdc DP1 10 TD-CRT LINK TILT FLOAT SOLENOID LINK TILT MOVES TO “FLOAT” POSITION OR FLOATS LINK TILT STOPS
10DQ8.5 NIS 24 vdc DP1 10 SPARE - -
10DQ8.6 NIS 24 vdc DP1 10 SPARE - -
10DQ8.7 NIS 24 vdc DP1 10 SPARE - -