DX Manual
DX Manual
FEATURE:
⊙Stable performance & high accuracy
48H×96W×58L
⊙Sampling rate:2.5 times/s
⊙Zero point adjustable
⊙Wide display range:±1999
36H×72W×58L 24H×48W×58L
CODE ILLUSTRATION
DX□□-□□□ Range
AV:AC voltmeter; DV:DC voltmeter
AA:AC ampere meter; DA:DC ampere meter
Power supply default:220V/110V AC D:12-30VAC/DC
Dimension(mm):2:24H*48W*58L; 3:36H*72W*58L; 8:48H*96W*58L
DX series digital panel meter
* DX2:12~30V AC/DC as default;DX3,DX8: 12~30VAC/DC for special order.
ORDERING CODE
◆AC digital voltmeter
*Only DX3 & DX8 are availabe for the CT input.DX2 is availe for the PT input(75mV),but not available for measurement AC 2A above
◆DC digital voltmeter
TECHNICAL SPECIFICATION
Max.display 1999(average value for AC signal)
Input Single-terminal input
Measurement mode Dual A/D conversation
Overflow indication “1” or “-1”
Polarity Display “-”for DC signal only
Power supply AC 110/220V±10%,50/60Hz; AC/DC 12-30V(DX2)
Energy consumption ≤4.5VA
Dielectrical strenth AC 1500V/1min
Insulation impedance DC 500V≥100MΩ
Frequency range of AC signal 40~200Hz
CONNECTION
Power Input Power Input Power Input
220V 220V
12-30V AC/DC (-) (+) ~ (-) (+) ~ (-) (+)
110V 110V
~ ~
↓ ↓ ↓
L ↓H ↓ ↓ ↓ ↓
L ↓H ↓ ↓ ↓ ↓
L ↓H
1 2 5 6 7 1 2 3 8 9 10 11 1 2 3 13 14 15
DX2 AC/DC voltmeter/ampere meter DX3 AC/DC voltmeter/ampere meter DX8 AC/DC voltmeter/ampere meter
* For DC signals,H is the positive polarity,while L the negative polarity;for AC signals,H for the fire line,while L for the zero line.
Note:all connections are subject to the diagram on the meter for change if any.
DIMENSION
A E 30
2 58
D
B
30