Download as pdf
Download as pdf
You are on page 1of 6
WANDLING FOR HIGH AMBIENT APPLICATION 39 FX New. Technology —> 39FX Series Central Station Air Handling Units are designed based on Carrier ‘Moduflex’ Series. The design of the Central Station Air Handling Units is ‘based on the use of standardized modular panels and *penta-post’ construction of perimeter frames. The standard and reference for design and performances. for 39FX Central Station AHUs components conforms mostly to ARILAMCA,and DIN. Standard unit configuration shall be horizontal or vertical draw-through or blow-through types. Pxemnaenenttn 39FX Central Station Air Handling Units casing ‘construction is fabricated from highest grade galvanized steel (G90 min spangle). to form sturdy Side/Top/Bottom panels and a rigid structure “Penta-post” frame, and location of Exhaust/Return/Fresh Air Damper. ‘The size and location of damper and f mixing section are selectable by 39FX Flex Air Program Dampers are designed j and assembled to run smoothly at low < pressure loss and low torque. Accommodate standard filters media to deliver clean air requirements for occupants, machine processes, indoors environment and ventilation system. All air filters have a dust spot efficiency up to 98%; the performances are tested according to ASHRAE Standard 52-76 or EUROVENT Standard 4/5, Higher Dust Spot Efficiency; the filter performance are accordance to DOP-test. Preliminary filter shall be made from fat form synthetics media, Aluminum filter shall be from wire mesh cleanable, washable, and flame resistance. Pleated synthetics V-filter, pleated depth shall be cleanable, washable, and flame resistance. Soft bag filters with up to 630-mm depth synthetics bag media and supported with galvanized ste! frames. ute filter with up to 300-mm depth synthetics or alas fi fiber bag media and supported with galvanized steel or aluminum frames, flame resistance, up to EU12 efficiency. ‘Mounting frames are made for easy access and minimal air leakage. Vv & DX Coi All water & DX coils performance are certified to ARI 410 Standard. Coils are cartridge type. Mounted on a condensate drain pan (for cooling coil) with aslide in-out coil track so that the complete assembly is wholly removable for easy maintenance. Standard coil fins material shall be aluminum copper or pre-coated aluminum, ‘Aluminum coated stee! fin is standard for steam coil Fin’s density can be from 8 FPI up-to 14 FPL. Fins shall be collar type; assembled with 1/2" OD copper tube (steel fins and steel tube for steam coils) and mechanically bonded to copper tube for greater heat transfer coefficient, Water coil — headers are made from seamless copper pipe and extended to outside pipe connection with threaded end (11 TPD steel tube. Copper header connection sweat type, without thread available as an option. DX coil headers shall be all copper tubes with sweat connection type. Coils shall be “Counter Flow” and equipped with vent and drain (drain and ‘yent — water coil only). Coils shall be tested at 300-psig submerged under water; designed to operate up to 230 psig (16 Bar) at 200°F (93°C). Drain pan is made of galvanized steel (powder painted or stainless steel), shall be mounted in slanted angle for complete and positive drainage, at one side of the drain pan. Bottom of the drain pan insulated to avoid condensation. PVC eliminator installed down stream of the coil when ever face velocity approaching 2.5 m/s (2.3 m/s for fresh air coil at highly humid condition), auto select by 39FX Flex Air Program. lectric Heater ~ Cartridge type with slide - Tubular type as standard. ~ Basic components shall be with airflow switch, power ‘& control terminal board grounding lug and primary & secondary over load temperature sensor assembled inside terminal box integrated with heating element and secured inside the stainless steel spherical sheathed fins copper tube. - Heating capacity & step is selectable by 39FX Flex Air Program. Grameen ~ Run around coil heat plate, heat wheel or heat pipe. Selectable by Flex Air Program. Forward, backward and airfoil curved, double inlet and double width (DIDW) centrifugal type. Fan performance rated in accordance to DIN 24 163 (Fans Performance Testing, Standardized Test Airways) in reference to AMCA Standard 210-99. Sound level shall be rated in accordance to DIN 45635 art 38 “Noise Measurement of Machine: Fan” in reference 10 AMCA Standard 300-96. Blades of the fans shall be from galvanized steel. Backward and airfoil fan’s blades shall be treated out. with epoxy paint. Wheel shall be statically and dynamically balanced within fan operating speed in compliance to DIN ISO Standard 1940, Standard fan bearings are “eccentric clamp bearing” type, single row ball bearing, mounted in pressed steel housing, pre-lubricated and sealed for life. Reinforced fan bearings are “self-aligning double rows ball bearing”, mounted in cast iron housing and re- greaseable. Bearing’s nominal life expectancy shall be 40,000 L10 operating hours (accordance DIN ISO 281 Section 1).. Rated bearing life can reach up to 200,000 L10 hours. ‘ For VAV application, Inlet Guide Vane (GV) can be Carrier exclusive FlexAir software program available for backward and airfoil fan; fan size range facilitate selection of 39FX’s many flexible features. from 400 to 1000 (option). This easy-to-use Windows based software helps to Create a configuration that’s optimized AHU 7 F application. Fastaccurate way to ensure that 39FX Fan Motor will meet performance and budget goals. eee and performance according to IEC standards Suitable to operate with Variable Frequency Drive i, (VED) ocFiequencyInvenr (F) epbicaton Carrier, TEFC, IP55, Class F insulation, Class B Temperature Flex Air Rise. Operating at 50°C ambient. PTO as standard accessory. Fan & Motor Assembly Single mounting base made of heavy gauge steel. Slide rail adjustment for flexible belt tensioning, ‘Tsolated with spring or rubber isolators to the floor. Isolated with flexible canvas to fan panel. Fan and MXB section's access door panel equipped with hard nylon hinges I and metal lock. { Quick release panels for filter section, “AIR QUANTITY RANGE, 7 hr x 1000. fella] 9] 10] sa] a2] 13] 14] 15] 17] 20] 30[ a0] so] 60] 70] eo] 90 100) BSR2 GHESG BBE >= RReRS BERG RE X* | ———S= — a — 37 37 — 3e1 424 | a | a0 40 —__ 463 503 | a Bo 631 —_ | [== } Min. to Max Airflow for Cooling Coils (Standard Col), I ‘Airfiow for codling Cols @ Extended Coils (Englarged Call Face Area). Airflow Heating Cols, Col Face Area For Standard Coll (m2) Col Face Area For Enlarged Coll (m2). 2 Large sizes available up to 99FX-1218, (160.000 emh } selectable by Flex Ar Re <=> Turn to the Experts 39 FX CENTRAL STATION AIR HANDLING UNIT Quality Assurance © Manufactured in a facility registered to ISO 9001:2000 / EN ISO 9001:2000 / ANSIASQC Q9001:2000 © 39F Flex Air Selection Program * AHU designed accordance to EN 1886 . © ARI 410 Certified Coils, © Polyurethane insulation for flame spread and smoke generation rated according to DIN 4102 Class B3, ISO 3785. * Airtight seal material meets NFPA 90A. requirements for flame spread and smoke generation. * Casing sheet metal withstand 500-hours salt spray exposure per ASTM B17 * Air filters performance according to ASHRAE Standard 52-76 or EUROVENT Standard 4/5 * Electric Heater manufactured accordance to NEC and UL Space Heating Standard No 1996 © Fan performance certified to DIN and AMCA, * Fan motor manufactured to conform IEC Standard Carrier. Flex Air Quality for Life As the world leader in Heating, Ventilation and Air Conditioning Carrier is committed to continually improving the quality of comfort we provide to our customers. But our level of responsibility extends well beyond. Carrier Corporation has identified six specific areas, which directly impact how we, as a world ‘manufacturer, balance our ‘customers’ needs for comfort with the environment’ needs for responsible consumption. These symbols graphically represent our six areas of ‘concentration and will serve as visual reminders of the importance of managing our finite resources. Each one of us at Carrier Corporation believes that, for ‘generation to.come, success will not only be measured by the quality of our products and systems, but also by how we have improved the quality of life. ele em) Carrier Corporation 39FX —01 FLR-05 Manufacturer reserves the right to disc or change at any time, specification or desi without notice and without incurring obligation.

You might also like