EV100 LX TROUBLESHOOTING
FC with TC Traction Card and PX Pump Card
CAUTION
Care must be taken when replacing the EV100
control card. Installation of the wrong control card
- 1 00
EV
may cause misoperation. Refer to subtitle and OL
NTR
CO
parts breakdown for card type and part number. SCR
920114 5217
Operate the truck until a failure occurs. When a failure occurs When the keyswitch is turned to the off position, a four digit
the handset will display the appropriate fault code. Fault number is displayed. This number represents the number of
codes always are preceded by a minus symbol (-)(illustration operation hours of the SCR system that the handset is
2). Refer to the fault code descriptions in this section for plugged into (illustration 4).
additional information and corrective procedures.
3412
3410 3494
HOUR METER EXAMPLE
FAULT CODE EXAMPLES ILLUSTRATION 4
ILLUSTRATION 2
The hour meter reading in this example indicates the SCR
Code numbers 1 through 6 and code number 8 are consid-
system that the handset is plugged into has been in
ered SRO codes (static return to off). SRO codes will be
operation 84 hours. To obtain the hours for the other SCR
displayed during improper sequencing of the operators
system (if applicable), the handset must be connected to
controls. For example, direction lever activated while brakes
the control card of that system.
are applied would display a code number -05.
Turn the truck keyswitch to the off position. The handset is
Code numbers 7 and 9 through 99 represent actual faults
now ready to be disconnected.
occurring on the traction panel. Lift panel fault codes are
numbers 100 through 199. Refer to the fault code descrip- WARNING
tions in this section for additional information and corrective
procedures. Before connecting or disconnecting the handset,
lift the drive wheels clear of floor and place
BATTERY STATE OF CHARGE hardwood blocks under truck frame. Turn key-
switch “OFF”, disconnect battery and discharge
When the truck is being operated and faults are not occur- capacitor 1C of the traction control.
ring, the display will show the Battery State of Charge. This
When handset functions are complete, unplug handset and
is a 3 digit number without a minus symbol (illustration 3). In
connect plug removed for handset connection.
this example the battery has 75% charge remaining.
3413
STATUS CODES
FP/FC
The EV100 LX/LXT SCR control utilizes an on board micro- On General Electric EV100LX SCR systems, codes 52 and
processor to monitor the SCR control system. By monitoring 53 are logged in the event of a PMT (Pulse Monitor Trip).
circuit voltages and system timing, the microprocessor can Troubleshooting procedures in the Service Manual for codes
isolate malfunctions in specific circuits. The malfunctions are 52 and 53 lists, in part as possible causes, an open circuit or
categorized by status codes which are communicated to the loose connection in the 3REC or 4REC circuit. These codes
service technician when using the display module. Listed in require the operator to re-key the truck in order to reset the
this section are the status codes which will be displayed and PMT function. This is notification to the operator and main-
the possible causes of the malfunction. tenance personnel that service is required and should not be
ignored. If a loose rectifier is not corrected, contactor tip
The display module stores all fault codes except the codes welding may result. Once contactor tip welding occurs,
which are caused by the operator using the wrong control status codes 23, 24 and 42, 46 may also be logged in status
sequence during operation (static return to off, SRO). These code history.
codes are displayed as messages to the operator to indicate
the cause of the truck not operating. The display module Crown recommends following the status code maintenance
stores up to eight codes with any one code being stored only procedures described in the service manual and verifying
once during a trucks powered up time. the condition of 3REC and 4REC(s) by removing and in-
specting per the following procedure:
Replace if signs
of pitting or corrosion
Inspect
are present
3REC 4REC
10290
3REC 4REC
10291
DISPLAY MODULE
FP/FC
The fault codes stored by the display module microproces- Messages which relate to SRO (static return to off) are
sor are displayed on the display module through the use of displayed to inform the operator why truck operation is not
the display switch. being permitted. SRO is control lockout due to switches
being operated in the wrong sequence i.e. direction selected
and traction requested before the truck is powered up.
FP/FC INTERFACE CARD FP/FC The message BRAK is displayed when traction is
0261P ILLUSTRATION 4.2-1 requested before the parking brake is released. If the parking
brake is released, the parking brake switch, wiring between
When the term “actuate” is used in this description, the the parking brake switch and traction control card or traction
switch must be moved to the “on” position and held for at control card is faulty. Trucks equipped with the automatic
least 1/4 of a second before it is released. This allows time parking brake, will not have BRAK displayed.
for the system to “read” the switch closure. Likewise, the
switch must be released for at least 1/4 second before again FP/FC The message ACEL is displayed when the operator
actuating. is seated, accelerator pressed, then the truck is powered up.
Also, when the truck is powered up and accelertor is pressed,
With the keyswitch in the “off” position and the battery the message SEAT will be displayed until the operator is
connected, actuate the display switch. If no fault codes are seated, at which time the message ACEL is displayed. If all
in memory, the message NONE will be displayed. If fault conditions are correct, the message indicates that the accel-
codes are in memory, the code relating to the last fault that erator voltage is too low when the pedal is released.
occurred will be displayed. Each time the display switch is
actuated the next fault back from the last will be displayed
and so on until all codes in memory have been displayed.
After the last code is displayed, and the display switch is
again actuated, the message CLR? will be displayed. If it is
desired to erase the codes in memory, actuate the erase
switch next to the display switch. All codes in the display
memory will be erased.
0305S-01
PCZ-9 PCZ-8
WHT/BLUE
BLUE
TB TERMINALS 1-6
CONTROL CARD
W
HT
CATHODE 2 REC
/B
LK
ANODE
T2 1 REC T5
T4
N
OW
ET
HEAT SINK VIOL T3
BR
3 REC
ORANGE
WHT/GRN
PCZ-14
REACTOR/CHOKE (1X)
A2 4 REC
BATTERY
NEGATIVE
CURRENT SENSOR
BATTERY
YELLOW
BROWN
GREEN
A1
POSITIVE TWISTED PAIR
PCZ-4 PCZ-2
PCZ-3
TWISTED PAIR WITH THIRD
WIRE WRAPPED AROUND
Monitoring Circuitry
The EV100 traction control system monitors various switches of a truck, which relate operator action, and accepts a speed
control signal. These truck monitors are inputs to the control card at screw terminals which are designated as TB11. The
following chart and schematic list the signal name for each input and provides a schematic to show the switches between
the battery and input point. Use this information when the Probable Cause under a status code directs to check the input
signal.
BATTERY BATTERY
NEGATIVE POSITIVE
KYS
SES (Key)
(Seat)
K5 OFF
ON
START
K3
K5-B K3-B
K1
FC CIRCUIT MONITOR
K1-A
Input Signal TB11-4
Terminal Description BRES
TB11-3 (Batt. Retainer)
TB11-1 Accelerator
K1-B
TB11-2 Brake
TB11-3 Seat or Floorboard EV100 LX BRS2-A
CONTROL (Park)
TB11-4 Keyswitch CARD
TB11-5 Forward
TB11-6 Reverse
TB11-1 ACCELERATOR
TB11-2
FS
(Forward)
TB11-5
TB11-6
RS
(Reverse)
This status code is displayed when input voltage to the control card and/or display STATUS CODE
unit is not present. BLANK DISPLAY
Symptom: Blank display screen.
Possible Cause:
• Make certain keyswitch has been cycled from “off” to “start” to “on”. Battery volts should be present at TB11-4 and
PCZ-7 using PCZ-3 for negative.
- Open circuit between traction control card plug PCY and display.
• Check for open circuit or loose connections between each wire going between traction control card plug PCY and
display.
- Defective display.
• Replace
STATUS CODE
This status code is displayed when TB11-3 is less than 50% of battery volts.
SEAT or
Symptom: Forward or reverse contactor will not energize.
PWR or
Possible Cause:
01
- Operator left truck with direction control not in neutral.
This status code is displayed when TB11-5 is greater than 60% battery volts at STATUS CODE
initial power up.
DIR or 02
Symptom: Forward contactor will not energize. Static return to off (SRO) lock out.
Possible Cause
- Defective card.
• Replace.
This status code is displayed when TB11-6 is greater than 60% battery volts at STATUS CODE
initial power up. DIR or 03
Symptom: Reverse contactor will not energize. Static return to off (SRO) lock out.
Possible Cause
- Defective card.
• Replace.
This status code is displayed when voltage at TB11-2 is less than 60% of battery STATUS CODE
volts at initial start-up. DIR or 04
Symptom: Forward or reverse contactor will not pick-up.
Possible Cause
- Direction control not in neutral at power up. Request traction. Status code display should change to 02 if forward travel
selected and 03 if reverse travel selected.
This status code is displayed when TB11-1 is less than 2.5 volts and TB11-2 is STATUS CODE
less than 60% of battery volts at the same time. BRAK or 05
Symptom: Forward or reverse contactor will not energize.
Possible Cause
- Traction speed control signal present at TB11-1 before input signal to TB11-2 present.
This status code is displayed when TB11-5 or TB11-6 are less than 60% of STATUS CODE
battery volts and TB11-1 is less than 2.5 volts. DIR or 06
Symptom: Forward or reverse contactor will not energize.
Possible Cause
- Traction speed control signal present at TB11-1 before input signal present at TB11-5 (forward) or TB11-6 (reverse).
This status code is displayed when the accelerator input voltage at TB11-1 is STATUS CODE
higher than 3.7 volts when a directional contactor is energized. 07
NOTE The code will only be displayed when attempting travel in one direction. When opposite direction is selected, code
will disappear.
Symptom: Forward or reverse contactor energize but control does not operate when speed command is increased or status
code is displayed until the truck starts to accelerate.
Possible Cause
- Accelerator control associated wiring short or open circuited. Check signal path for TB11-1.
• Accelerator input at TB11-1 should be 3.7 volts with the key “on” and the accelerator released. As speed request is
increased, voltage should decrease smoothly to .5 volts with top speed requested. Repair or replace accelerator
control.
This status code is displayed when the accelerator input voltage at TB11-1 is STATUS CODE
less than 3.0 volts when any of the following inputs are interrupted; TB11-4,
TB11-3 or TB11-2.
ACCEL or 08
Symptom: Forward or reverse contactor does not energize.
Possible Cause
- With no speed command from the accelerator, voltage at TB11-1 should be greater than 3.0 volts.
• Check adjustment of switches in the above signal input lines and associated wiring.
This status code will be displayed when TB11-5 and TB11-6 are greater than STATUS CODE
60% of battery volts at the same time.
09
Symptom: Forward or reverse contactor will not energize.
Possible Cause
- Forward and/or reverse switch contact welded or associated wiring short circuited.
• With directional control in the neutral position, check forward and reverse switch contacts for short circuits. Check
associated wiring for short circuits.
This status code is displayed when the battery volts are less than 1.95 volts per STATUS CODE
cell at initial start up. 15
Symptom: Forward or reverse contactor will not energize.
Possible Cause
• Check battery state of charge and overall condition. Take corrective action if necessary.
• If control card was just installed, make certain Function 15 of control card tune up is set correctly. Refer to tune up
section (M4.2) for correct value.
This status code is displayed when the battery volts are greater than 2.40 volts STATUS CODE
per cell at initial start up. 16
Symptom: Forward or reverse contactor will not energize.
Possible Cause
• If control card was just installed, make certain Function 15 of control card tune up is set correctly. Refer to tune up
section (M4.2) for correct value.
• Check for broken yellow wire between regenerative braking sensor and control card plug PCA.
This status code is displayed when the control card type selection value is set to STATUS CODE
an invalid number. 17
Symptom: Forward or reverse contactors will not energize.
Possible Cause
- Invalid card type selection made during new control card tune up.
• Make certain Function 17 of control card tune up is set correctly. Refer to tune up section (M4.2) for correct value.
This status code is displayed when the current draw in the forward or reverse STATUS CODE
contactor coil circuit is less than 100 ma. 23
Symptom: Forward or reverse contactor will not energize. Status code may alternate between status code 23 and status
code 24. Complete check for status code 23 and if the problem is not found, perform checks for status code 24.
Possible Cause
• Check wiring and connections between control card plug PCB position 4 and positive side of forward contactor coil.
Resistance of this circuit should be between 10 and 14 ohms.
• Check wiring and connections between control card plug PCB position 5 and positive side of reverse contactor coil.
Resistance of this circuit should be between 10 and 14 ohms.
• Disconnect plug PCB from control card and check resistance between positive side of contactor coils and plug PCB.
Resistance should be between 10 and 14 ohms. Plug PCB position 6 for the 1A contactor, position 2 for the
regenerative braking contactor, position 3 for the steering pump contactor and position 1 for the field weakening
contactor.
This status code is displayed when T2 volts is greater than 12% of battery volts STATUS CODE
and the forward and reverse driver is enabled. 24
Symptom: SCR control does not operate. Status code display may alternate between status code 23 and status code 24.
Complete check for status code 24 and if the problem is not found, perform checks for status code 23.
Possible Cause
- RB contactor failure.
• Disconnect plug PCB from control card and check resistance between positive side of contactor coil and plug PCB
position 2. Resistance should be between 10 and 14 ohms.
• Check for loose connection or open circuit in motor circuit between terminals A1 and A2 on SCR panel.
This status code is displayed when 1A contactor drop out time exceeds .060 STATUS CODE
seconds. 25
Symptom: Short tip life on forward and reverse or 1A contactor. Status code 46 displayed and no fault found.
Possible Cause
NOTE: This status code is a troubleshooting aid for status code 46.
This status code is displayed when a shorted RB, SP or FW coil driver is present STATUS CODE
in the control card. 26
Symptom: RB, SP or FW contactor energizes immediately when keyswitch is closed.
Possible Cause
This status code is displayed when voltage between PCZ-1 and PCZ-5 is greater STATUS CODE
than 1.8 volts. 41
Symptom: Reduced or no power to traction control in SCR range.
Possible Cause
• Check for loose connection or broken black wire between the thermal protector and control card plug PCZ-1.
• Check for loose connection or broken gray wire between the thermal protector and control card plug PCZ-5.
• Disconnect plug PCZ from control card. With thermal protector at room temperature (75° F / 25° C), check resistance
between plug positions 1 and 5. Replace thermal protector if resistance value is greater than 300 ohms.
This status code is displayed when voltage between plug PCZ-4 and battery STATUS CODE
negative is greater than 1.6 volts with no current flowing in the motor circuit. 42
Symptom: No power to traction motor in SCR range.
Possible Cause
• Check for broken green wire between current sensor and control card plug PCZ-4.
This status code is displayed when voltage between PCZ-4 and battery negative STATUS CODE
is less than .84 volts with no current flowing in motor circuit. 43
Possible Cause
• Check for broken yellow wire between current sensor and control card plug PCZ-3.
This status code is displayed when, during SCR operation, 1 REC fails to turn off. STATUS CODE
44
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
• Check for open circuit between terminals T5 and T3 of reactor/choke. Resistance reading should be near zero ohms.
- Defective 1 REC.
• Turn off time for 1 REC out of specification. No field test is reliable. Replace 1 REC after above checks show no
problem found.
Crown 1991 PF8969-17 Rev. 12/03 Printed in U.S.A.
08 REV. 12/03
M4.2–20.0–416 M4.2–20.0–416
C MAINTENANCE
This status code is displayed when 1 REC fails to gate on. STATUS CODE
45
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
• Check for open circuit or loose connections of white stripe/blue wire between 1 REC and control card plug PCZ
position 8.
• Check for open circuit or loose connection of blue wire between 1 REC and control card plug PCZ position 9.
- Defective 1 REC.
• Intermittent or open 1 REC gate. Field test may not show defect. Replace 1 REC after above checks show no problem
found.
This status code is displayed when the voltage at T2 is greater than 85% of STATUS CODE
battery volts during the look ahead test. 46
Symptom: Forward or reverse contactor will not energize.
Possible Cause
- Defective 1 REC
• Check for defective 1 REC insulator that may allow short circuit between 1 REC heat sink and base plate.
- Defective 1A contactor.
- Use handset and access function 1. If status code 25 or 125 is displayed, proceed that status code and perform checks
listed.
This status code is displayed when the 2 REC fails to turn on. STATUS CODE
47
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
• Check for open circuit or loose connection in white stripe/red wire between 2 REC gate and control card plug PCZ
position 10
• Check for open circuit or loose connection between 1 REC and 1C in the 2 REC circuit.
This status code is displayed when the voltage at T2 is less than 12% of battery STATUS CODE
volts during the look ahead test. 48
Symptom: Forward or reverse contactor will not energize.
Possible Cause
• Check condition of forward and reverse contactors. Sluggish operation will cause this status code.
This status code is displayed when the 5 REC fails to turn on. STATUS CODE
49
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
• Check for open circuit or loose connection of white stripe/ violet wire between 5 REC gate and control card plug PCZ
position 12.
• Check capacitor 1C for open circuit.With meter an the R x 10,000 ohm scale, Measure resistance through the
capacitor. Meter should indicate zero ohms, then swing slowly to above 100,000 ohms. Replace capacitor if this
action is not obtained.
This status code is displayed when 2 REC circuit fails to turn on at initial start up. STATUS CODE
Capacitor 1C volts too low. 50
Symptom: Forward or reverse contactor energizes. Control does not operate.
Possible Cause
• Check for open circuit or loose connection on bus bar between spider assembly and 5 REC.
• Check for open circuit or loose connection on bus bar between 5 REC and 2 REC.
• Check for open circuit or loose connection on red wire between 2 REC and control card plug PCZ position 11.
• Check for open circuit or loose connection on white stripe/red wire between 2 REC and control card plug PCZ position
10.
This status code is displayed when capacitor volts exceed 225 volts and motor STATUS CODE
current is greater than 300 amps. 51
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
• Electronic equipment added to truck electrical system without proper filtering being used.
This status code is displayed when capacitor volts exceed 225 volts and motor STATUS CODE
current is less than 200 amps. 52
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
• Electronic equipment added to truck electrical system without proper filtering being used.
This status code is displayed when 1 REC fails to turn off during plug cycle. STATUS CODE
53
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
• Stall vehicle in both directions for no more than 3 seconds at a time and allow motor to cool between stalls. Note any
status codes displayed that may more closely define the failure. Troubleshoot for the new status code.
• Check 4 REC circuit for loose or open bus bar and cable connections.
• Check yellow wire between current sensor and control card plug PCZ position 3 for open circuit and loose
connections.
• Check green wire between current sensor and control card plug position 4 for open circuit and loose connections.
This status code is displayed when the forward, reverse or 1A contactor coil STATUS CODE
driver is short circuited internal to the control card. 54
Symptom: Control will not operate.
Possible Cause
• Replace.
This status code is displayed when the voltage input to control card plug PCZ STATUS CODE
positions 3 and 4 are wrong polarity. 57
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
• Check that green wire from current sensor is in position 4 of control card plug PCZ.
• Check that yellow wire from current sensor is in position 3 of control card plug PCZ.
• Make certain battery negative cable connects to SCR NEG terminal of SCR panel.
• Make certain motor A2 cable connects to the SCR A2 terminal of SCR panel.
This status code is displayed when regenerative braking current sensor input STATUS CODE
signal at PCA-4 (yellow wire) is missing. 70
Symptom: Control does not operate.
Possible Cause
• Check yellow wire between current sensor and control card connector PCA position 4 for loose connections and open
circuit.
This status code is displayed when regenerative braking current sensor input STATUS CODE
signal at PCA-5 (green wire) is missing. 71
Symptom: Control does not operate.
Possible Cause
• Check green wire between current sensor and control card connector PCA position 5 for loose connections and open
circuit.
This status code is displayed when traction control card is in the normal opera- STATUS CODE
tion mode and 2.5 volts or greater is present at control card connector PCA-6.
72
Symptom: Regenerative braking contactor (RB) does not energize.
Possible Cause
• Check for open circuit or loose connection between traction control card plug PCA position 6 and the A2 connection
of the RB contactor.
• Check for open circuit or loose connection between 7 REC and the A2 connection of the RB contactor.
This status code is displayed when the RB contactor tips do no open after 100 STATUS CODE
milliseconds after power is removed from the RB contactor coil. 73
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
- Defective RB contactor.
• Check for loose connections in the circuit between the traction control card plug PCA-6 and the A2 connection of the
RB contactor.
This status code is displayed when the regenerative braking (RB) contactor tips STATUS CODE
do not close within 100 milliseconds after power is applied to the RB contactor
coil.
74
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
- Defective RB contactor.
• Check for loose connections in the circuit between the traction control card plug PCA-6 and the A2 connection of the
RB contactor.
• Check wiring between coil negative terminal and traction control card plug PCB position 2 for open circuits and loose
connections.
• Check wiring between coil positive terminal and battery positive for open circuits and loose connections.
This status code is displayed when 1 REC does not turn off during the regenera- STATUS CODE
tive braking cycle. 75
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
• Stall vehicle in both directions for no more than 3 seconds at a time and allow motor to cool between stalls. Note any
status codes displayed that may more closely define the failure. Troubleshoot for the new status code.
• Check for loose connections on regenerative braking power circuits from battery positive to the RB contactor A2
connection.
• Check yellow wire between RB current sensor and control card plug PCA position 4 for open circuit and loose
connections.
• Check green wire between RB current sensor and control card plug PCA position 5 for open circuit and loose
connections.
• Check control wire between RB contactor coil positive terminal and control card plug PCA position 6.
This status code is displayed when capacitor voltage is greater than 225 volts STATUS CODE
during the regenerative braking cycle. 76
Symptom: Forward or reverse contactors open momentarily, close and open again (PMT trip).
Possible Cause
• Check for loose connections in battery circuit between the battery and the SCR panel.
• Electronic equipment added to truck electrical system without proper filtering being used.
Not Used. Reserved for pump motor temperature sensor. STATUS CODE
90
Not Used. Reserved for power steering pump motor temperature sensor. STATUS CODE
91
This status code is displayed when voltage at terminal 4 of Truck Management STATUS CODE
Module (TMM) is zero volts. 92
Symptom: Status code flashes on and off.
Possible Cause
• Any condition which will cause the motor to draw excessive current will increase the operating temperature. Check
mechanical condition of motor, drive unit, brakes etc. Check motor armature and field windings for short circuits.
Not Used. Reserved for pump motor brush wear indicator. STATUS CODE
93
Not Used. Reserved for power steering pump motor brush wear indicator. STATUS CODE
94
This status code is displayed when voltage at terminal 11 or 12 of Truck Manage- STATUS CODE
ment Module (TMM) is zero volts. 95
Symptom: Status code flashes on and off.
Possible Cause
• Replace brushes.
This status code is displayed when the control card type selection value is set to STATUS CODE
an invalid number. 117
Symptom: Control will not operate.
Possible Cause
- Invalid control card type selection made during new control card tune up.
• Make certain Function 17 of control card tune up is set correctly. Refer to tune up section (M4.2) for correct value.
Not used. This status code is displayed when the current draw in the pump STATUS CODE
contactor coil circuit is less than 100 ma.
123
Symptom: Pump contactor will not energize. Status code may alternate between status code 123 and status code 124.
Complete checks for 123, if the problem is not found, perform checks for status code 124.
Possible Cause
• Check circuitry between pump control card terminal TB11-5 and battery negative connection.
Not used. This status code is displayed when voltage at T2 is greater than 12% STATUS CODE
of battery volts when the pump driver is enabled. 124
Symptom: Control does not operate. Status code may alternate between status code 123 and status code 124. Complete
checks for 124, if the problem is not found, perform checks for status code 123.
Possible Cause
• Defective pump contactor coil. Perform checks listed for status code 123.
• Check motor circuit for open or loose connections between the A1 and A2 connections on SCR panel.
• Check for loose connections and open circuits in wiring between negative contactor coil terminal and pump control
card plug PCB position 5.
• Check resistance of contactor coil (10 to 14 ohms). If not within this range, replace.
This status code is displayed when P2 contactor drop out time is greater than STATUS CODE
.060 seconds. 125
Symptom: Short tip life on 1A contactor. Status code 46 displayed and no fault found.
Possible Cause
NOTE This status code can only be found by using the handset and accessing function 1. This status code is furnished as
a troubleshooting aid for status code 46.
- Defective P2 contactor.
• Make checks that would cause slow operation of contactor when dropping out.
This status code is displayed when the voltage between pump control card plug
PCZ positions 1 and 5 is greater than 1.8 volts. STATUS CODE
141
Symptom: Reduced or no power to pump motor in SCR range.
Possible Cause
• Check for loose connection or open circuit in black wire between pump motor thermal protector and pump control
card plug PCZ position 1.
• Check for loose connection or open circuit in gray wire between pump motor thermal protector and pump control card
plug PCZ position 5.
• Disconnect plug PCZ from pump control card. At room temperature (25°C or 75°F) measure resistance between
positions 1 and 5. If resistance between these positions is greater than 300 ohms, replace thermal protector.
• Allow control to cool. Status code should disappear and normal operation should return.
This status code is displayed when voltage between pump control card plug STATUS CODE
PCZ-4 and battery negative is greater than 1.6 volts with no current flowing in the
motor circuit. 142
Symptom: No power to pump motor in SCR range.
Possible Cause
• Check green wire between pump current sensor and pump control card plug PCZ position 4 for loose connections
and open circuit.
This status code is displayed when voltage between pump control card plug STATUS CODE
PCZ-4 and battery negative is less than .84 volts with current flowing in the motor 143
circuit.
Symptom: Stall currents is SCR range higher than normal and uncontrollable with C/L adjustment.
Possible Cause
• Check yellow wire between pump current sensor and pump control card plug PCZ position 3 for loose connections
and open circuit.
This status code is displayed when, during SCR operation, 1 REC fails to turn off. STATUS CODE
• Check for open circuit between terminals T5 and T3 of reactor/choke. Resistance reading should be near zero ohms.
- Defective 1 REC.
• Turn off time for 1 REC out of specification. No field test is reliable. Replace 1 REC after above checks show no
problem found.
This status code is displayed when 1 REC fails to gate on. STATUS CODE
145
Symptom: Control does not operate. PMT trip.
• Check for open circuit or loose connections of white stripe/blue wire between 1 REC and pump control card plug PCZ
position 8.
• Check for open circuit or loose connection of blue wire between 1 REC and pump control card plug PCZ position 9.
- Defective 1 REC.
• Intermittent or open 1 REC gate. Field test may not show defect. Replace 1 REC after above checks show no problem
found.
This status code is displayed when the voltage at T2 is greater than 85% of STATUS CODE
battery volts during the look ahead test. 146
Symptom: Control does not operate.
Possible Cause
- Defective 1 REC
• Check for defective 1 REC insulator that may allow short circuit between 1 REC heat sink and base plate.
- Defective P2 contactor.
This status code is displayed when the 2 REC fails to turn on. STATUS CODE
147
Symptom: Control does not operate. PMT trip.
Possible Cause
• Check for open circuit or loose connection in white stripe/red wire between 2 REC gate and control card plug PCZ
position 10
• Check for open circuit or loose connection between 1 REC and 1C in the 2 REC circuit.
This status code is displayed when the voltage at T2 is less than 12% of battery STATUS CODE
volts during the look ahead test. 148
Symptom: Control does not operate.
Possible Cause
• The pump control is used without a pump contactor so the correct card type must be selected during tune up. Access
function 17 with the handset and verify card type selection. Refer to tune up section (M4.2) for correct value.
This status code is displayed when the 5 REC fails to turn on. STATUS CODE
149
Symptom: Pump contactor opens momentarily, closes and opens again, then can only be closed by opening and closing
the key switch.
Possible Cause
• Check for open circuit or loose connection of white stripe/violet wire between 5 REC gate and control card plug PCZ
position 12.
• Check capacitor 1C for open circuit. With meter on the R x 10,000 ohm scale, measure resistance through the
capacitor. Meter should indicate zero ohms, then swing slowly to above 100,000 ohms. Replace capacitor if this
action is not obtained.
This status code is displayed when 2 REC circuit fails to turn on at initial start up. STATUS CODE
Capacitor 1C volts too low. 150
Symptom: Control does not operate.
Possible Cause
• Check for open circuit or loose connection on bus bar between spider assembly and 5 REC.
• Check for open circuit or loose connection on bus bar between 5 REC and 2 REC.
• Check for open circuit or loose connection on red wire between 2 REC and control card plug position 11.
• Check for open circuit or loose connection on white stripe/red wire between 2 REC and control card plug PCZ position
10.
This status code is displayed when capacitor volts exceed 225 volts and motor STATUS CODE
current is greater than 300 amps. 151
Symptom: Control does not operate. PMT trip.
Possible Cause
• Electronic equipment added to truck electrical system without proper filtering being used.
This status code is displayed when capacitor volts exceed 225 volts and motor STATUS CODE
current is less than 200 amps. 152
Symptom: Control does not operate. PMT trip.
Possible Cause
• Electronic equipment added to truck electrical system without proper filtering being used.
This status code is displayed when the P2 contactor coil driver is short circuited STATUS CODE
internal to the control card. 154
Symptom: Control will not operate.
Possible Cause
• Replace.
This status code is displayed when the voltage input to control card plug PCZ STATUS CODE
positions 3 and 4 are wrong polarity. 157
Symptom: Control does not operate. PMT trip.
Possible Cause
• Check that green wire from current sensor is in position 4 of control card plug PCZ.
• Check that yellow wire from current sensor is in position 3 of control card plug PCZ.
• Make certain battery negative cable connects to SCR NEG terminal of SCR panel.
• Make certain motor A2 cable connects to the SCR A2 terminal of SCR panel.