Report No.: Test Time: 2016-12-14 17:24

Luminaire Property
Luminaire Category:
Luminaire Description: AR101215WW Lamp Description: AR111-GU10-3000K-15W
Voltage: 230.1 V Current: 0.119 A
Power: 15.70 W Power Factor: 0.569

Photometric Results
CIE Class: Direct Total Rated Lamp Lumens: 1240.1 lm
Measurement Flux: 1240.1 lm Efficiency: 100%
Downward Ratio: 100% Upward Ratio: 0%
Field Angle: H50.0 V50.1 Beam Angle: H24.1 V23.9
Luminaire Efficacy Rating (LER): 79 Central Intensity: 4518.27 cd
Max. Intensity: 4521.82 cd Pos of Max. Intensity: H180 V1

Picture Of Luminaire Luminous Intensity Distribution Curve

165 180 165


150 150
135 135

120 120

105 105

90 90
1130
75 2260 75

60 3390 60

45 4520 45
30 5650 30
15 0 15
Unit: cd

C0-C180 C90-C270 G1

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0


Test Lab: Test Device: GPM-1200A
Test Type: TYPE C Distance: 1.000 m
Temperature: Humidity:
Operator: Inspector:
Page 2 of 6 Pages

Luminous Intensity Distribution Curve

165 180 165


150 150
135 135

120 120

105 105

90 90
1130
75 2260 75

60 3390 60

45 4520 45
30 5650 30
15 0 15

5650

4520

3390

2260

1130

0
-180 -120 -60 0 60 120 180
C0-C180 C90-C270 Unit: cd
C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0
Test Lab: Test Device: GPM-1200A
Test Type: TYPE C Distance: 1.000 m
Temperature: Humidity:
Operator: Inspector:
Page 3 of 6 Pages

IsoLux Plot

3
Horizontal distance / mount height

0129
5
0 23

5
5 4 3 2 1 0 1 2 3 4 5
Vertical distance / mount height

Mounting Height: 10m Max Lux(100%): 45 lx


( 1%): 0 lx ( 2%): 1 lx
( 5%): 2 lx ( 10%): 5 lx
( 20%): 9 lx ( 50%): 23 lx
(100%): 45 lx

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0


Test Lab: Test Device: GPM-1200A
Test Type: TYPE C Distance: 1.000 m
Temperature: Humidity:
Operator: Inspector:
Page 4 of 6 Pages

Illuminance at a Distance

Distance(m) E(lx) Dh(m) Dv(m) Eav(lx)

1.0 4518.27 0.43 0.42 623.59

1.5 2008.12 0.64 0.64 277.15

2.0 1129.57 0.85 0.85 155.90

2.5 722.92 1.07 1.06 99.77

Dh 3.0 502.03 1.28 1.27 69.29

Dv Beam Angle: H24.1 V23.9 Field Angle: H50.0 V50.1

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0


Test Lab: Test Device: GPM-1200A
Test Type: TYPE C Distance: 1.000 m
Temperature: Humidity:
Operator: Inspector:
Page 5 of 6 Pages

Vertical IsoLux Plot

1 226

4
Vertical Height(m)

6
90

9
45
10

11
0 1 2 3 4 5 6 7 8 9 10
Horizontal distance(m)

Lowest(m): 1m Highest(m): 11 Max Lux: 4518


( 1%): 45 lx ( 2%): 90 lx
( 5%): 226 lx ( 10%): 452 lx
( 20%): 904 lx ( 50%): 2259 lx
(100%): 4518 lx

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0


Test Lab: Test Device: GPM-1200A
Test Type: TYPE C Distance: 1.000 m
Temperature: Humidity:
Operator: Inspector:
Page 6 of 6 Pages

The average illuminance effective figure


Flux Out: 1126.24lm

1.0m 358.49/ 4518.27lx 200.00cm

1.5m 159.33/ 2008.12lx 300.00cm

2.0m 89.62/ 1129.57lx 400.00cm

2.5m 57.36/ 722.92lx 500.00cm

3.0m 39.83/ 502.03lx 600.00cm

Height Avg./Nadir. E Beam Angle:90.00 Diameter

C Plane (°):0.0-360.0: 45.0 Gamma Plane (°):0.0-90.0:1.0


Test Lab: Test Device: GPM-1200A
Test Type: TYPE C Distance: 1.000 m
Temperature: Humidity:
Operator: Inspector: