Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Notes:

A B A B A

B C B C B A T16@150mm C/C B.W GENERAL NOTES :


1/Concrete fcu should not be less
than ((30N/mm2))for
Columns&foundations for 28days
A B A B A B T16@300mm C/C B.W strength and((25N/mm2)) for
Beams&Slabs.
2/Steel fy should not be less than
460N/mm.2 .

A A 3/Max-aggregate size 20mm for

B B C T16@450mm C/C B.W


beams
& cols &slabs and 30mm for
foundation.
4/Concrete cover for reinforcement
should not be less than 25mm
beams
A B A & cols & slabs and 50mm for
B A foundation.
5/Over laps of steel should not be
less
than 45times larger bar size &
should
always be located within concrete
being
B B A B B under compression.
6/construction joint shall be located
at one fifth of span of slabs.
7/Slab thickness 250mm.
8/Bearing Capacity ((208 kN/m.2))
9/ Depth of foundatoin from the
top of the replacmen layer -3m
A B A B A from soil report.
10/ /Steel fy should not be less than
460N/mm.2 for shear reinforced for
Punching shear and the number of
sttirups branches is not less then 6
B C B C B branches and the maximum
spaceing. between sttirups
is((100mm))

A B A B A Gmail
jestackengineering@
gmail.com
00249999420418
TEL
00249902877734
Owner Mohamed Abd Allah
TOWN Bahri / Khartoum
Plot: 1/911 PROJECT:
Col. Srip Mid. Srip Col. Srip Mid. Srip Block: 51
RESIDENTIAL
BUILDING
0.2

SHEET Typical Top Reinforcement


T16@300 T16@150 Title
T12@150 Build Area 172 m2
SCALE:
1:100

Designer Adeeb Motwali DATE:


5/11
Abdallah 2022