ECP4404T Customer Information BALDOR

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Customer information packet


ECP4404T

75HP, 1185RPM, 3PH, 60HZ, 405T, A40064M, TEFC


Class - None
Division - Division II

Copyright © All product information within this document is subject to ABB Motors and Mechanical Inc. copyright © protection, unless otherwise noted.
1/14/2023 4:21:00 PM
CUSTOMER INFORMATION PACKET ECP4404T - 75HP, 1185RPM, 3PH, 60HZ, 405T, A40064M, TEFC

Specifications Part detail

Enclosure TEFC Revision L


Frame 405T Type AC
Frame Material Iron Mech. spec.
Frequency 60.00 Hz Base
Motor Letter Type Three Phase Status PRD/A
Output @ Frequency 75.000 HP @ 60 HZ Elec. spec. A40WG0463
Phase 3 Layout 617429-501
Synchronous Speed @ Frequency 1200 RPM @ 60 HZ Eff. date 03-12-2020
Voltage @ Frequency 230.0 V @ 60 HZ CD Diagram 416820-002
460.0 V @ 60 HZ Poles 06
XP Class and Group None Leads 3#2,6#4
XP Division Division II Proprietary False
Agency Approvals CSA EEV Created date 07-15-2013
Ambient Temperature 40 °C
Auxillary Box No Auxillary Box
Base Indicator Rigid
Bearing Grease Type Polyrex EM (-20F +300F)
Constant Torque Speed Range 10-60
Current @ Voltage 173.000 A @ 230.0 V
86.900 A @ 460.0 V
Design Code B
Drip Cover No Drip Cover
Duty Rating CONT
Efficiency @ 100% Load 95.0 %
Feedback Device NO FEEDBACK
Heater Indicator No Heater
High Voltage Full Load Amps 86.9 a
Insulation Class F
Inverter Code Inverter Ready
KVA Code G
Lifting Lugs Standard Lifting Lugs
Motor Lead Quantity/Wire Size 3 @ 2 AWG
Motor Standards NEMA
Motor Type A40064M Page 2 of 9

Mounting Arrangement F1
Number of Poles 6
Inverter Code Inverter Ready
KVA Code G
Lifting Lugs CUSTOMER INFORMATION PACKET ECP4404T - 75HP,Standard Lifting
1185RPM, 3PH, Lugs
60HZ, 405T, A40064M, TEFC
Motor Lead Quantity/Wire Size 3 @ 2 AWG
Motor Standards NEMA
Motor Type A40064M
Mounting Arrangement F1
Number of Poles 6
Overall Length 38.20 IN
Power Factor 85
Pulley End Bearing Type Ball
Pulley Face Code Standard
Service Factor 1.15
Shaft Ground Indicator No Shaft Grounding
Shaft Rotation Reversible
Shaft Slinger Indicator Shaft Slinger
Speed 1185 rpm
Speed Code Single Speed
Starting Method Direct on line
Thermal Device - Bearing None
Thermal Device - Winding None
XP Temp Code T3

Page 3 of 9
CUSTOMER INFORMATION PACKET ECP4404T - 75HP, 1185RPM, 3PH, 60HZ, 405T, A40064M, TEFC

Nameplate

NP3238
CAT NO ECP4404T SPEC NO. P40G3909
HP 75 AMPS 173/86.9 VOLTS 230/460 DESIGN B
FRAME 405T RPM 1185 HZ 60 AMB 40 SF 1.15
D.E. BRG.DATA 6316 O.D.E. BRG.DATA 6316 PH 3 DUTY CONT INSUL.CLASS F
D.E. BRG. 80BC03J30X TYPE P ENCL TEFC CODE G
O.D.E. BRG. 80BC03J30X POWER FACTOR 85 NEMA NOM EFFICIENCY 95
3/4 LOAD EFF. 95.3 MAX CORR KVAR 15.0 GUARANTEED EFFICIENCY 94.1
TEMP CODE T3 TEMP = 200
CHP HZ 60-90 CT HZ 10-60 VT HZ 0-60
INVERTER-TEMP-CODE T3
SER.NO. MOTOR WEIGHT 1275

Page 4 of 9
CUSTOMER INFORMATION PACKET ECP4404T - 75HP, 1185RPM, 3PH, 60HZ, 405T, A40064M, TEFC

Page 5 of 9
CUSTOMER INFORMATION PACKET ECP4404T - 75HP, 1185RPM, 3PH, 60HZ, 405T, A40064M, TEFC

Page 6 of 9
CUSTOMER INFORMATION PACKET ECP4404T - 75HP, 1185RPM, 3PH, 60HZ, 405T, A40064M, TEFC

8 7 6 5 4 3 2 1

617429-501

DUTY MASTER ALTERNATING CURRENT MOTORS


SQUIRREL-CAGE INDUCTION
F
F

ENCLOSURE: TOTALLY ENCLOSED FRAME G405T ABOVE NEMA RATINGS COOLING: FAN COOLED

MOUNTING: FOOT INCLUDES 404T FRAME MOUNTING HOLES XT/ECP SEVERE DUTY ENCLOSURE

E E

38.20 19.21
10.92 11.50

5.62 13.17
6.00 6
4.00
1.8 1.8
15.25

D D
7.83
.75 SQ. KEY
7.26

7.14
21.48
5.63

15.56 4.12
6.88
2.875 3 9.98
C C

4 3.00 LEAD 2
OPENING

1 1.50 3.60
1.23
7.00 7.00 8.00 8.00
13/16
12.25 6.62 16.00 6 HOLES

13.75 19.00

B 18.01 B

1. GROUND HOLES QTY 1 1/2-13 TAP; QTY 1 3/8-16 TAP


2. VARIES +.00,-.06
3. VARIES +.000,-.001
4. ON STANDARD MOTORS THIS IS CONDUIT SIZE. ON XT AND
CORROSION PROOF MOTOR THIS IS PIPE TAP.
5 WEIGHT (LBS): 1370
5. MOTOR WEIGHTS MAY VARY BY 15% DEPENDING ON RATING.
6. OBSTRUCTION MUST NOT ENCROACH ON AIR INLET

A CONDUIT BOX LOCATED ON OPPOSITE SIDE WHEN F-2. DIMENSIONS ARE IN INCHES; SEE SHEET 2 FOR DIMENSIONS IN MILLIMETERS A
IF MOUNTING CLEARANCE DETAILS ARE REQUIRED, CONSULT FACTORY.

617429-501
MAXIMUM PERMISSIBLE SHAFT RUNOUT WHEN MEASURED AT END OF
STANDARD SHAFT EXTENSION IS .003" T.I.R. TO 5 INCH DIA. CUSTOMER IS RESPONSIBLE FOR DETERMINING THAT MOTOR PERFORMANCE IS SUITABLE IN THE APPLICATION.
SHEET NUMBER REV. DESC: CHANGE BA FROM 6.76 TO 6.62
1 OF 2 REV: B VERSION: 02 REVISED: 01:11:16 04/14/2014 TDR: 000000848770
MODEL NO. 617429-501 REF:
G405T/404T STD – FOOTED – XT/ECP SEVERE DUTY ENCLOSURE
617429-501
BY: MGHJMZ2 Material: C
8 7 6 5 4 3 2 1

P40G3909: 75HP,1185RPM,3PH,60HZ,405T,A40064M,TEFC Page 7 of 9


CUSTOMER INFORMATION PACKET ECP4404T - 75HP, 1185RPM, 3PH, 60HZ, 405T, A40064M, TEFC

8 7 6 5 4 3 2 1

617429-501

DUTY MASTER ALTERNATING CURRENT MOTORS


SQUIRREL-CAGE INDUCTION
F
F

ENCLOSURE: TOTALLY ENCLOSED FRAME G405T ABOVE NEMA RATINGS COOLING: FAN COOLED

MOUNTING: FOOT INCLUDES 404T FRAME MOUNTING HOLES XT/ECP SEVERE DUTY ENCLOSURE

E E

970.3 488
292.1
285.6
142.8 334.5
152.4 6
101.6
45 45
387.2

D D
198.9

184.4
19.1 SQ. KEY
181.4
545.7
143

395.1 174.6 104.6


253.6
C
73 3
C
2
4 76.2 LEAD
OPENING

1 38.1 91.5
31.3
177.8 177.8 203.2 203.2
20.6
311.2 168.2 406.4 6 HOLES
349.3 482.6

B 457.5 B

1. GROUND HOLES QTY 1 1/2-13 TAP; QTY 1 3/8-16 TAP


2. VARIES +.0,-1.5
3. VARIES +.00,-.03
4. ON STANDARD MOTORS THIS IS CONDUIT SIZE. ON XT AND
CORROSION PROOF MOTOR THIS IS PIPE TAP.
5 WEIGHT (KGS): 630
5. MOTOR WEIGHTS MAY VARY BY 15% DEPENDING ON RATING.
6. OBSTRUCTION MUST NOT ENCROACH ON AIR INLET

A CONDUIT BOX LOCATED ON OPPOSITE SIDE WHEN F-2. DIMENSIONS ARE IN MILLIMETERS; SEE SHEET 1 FOR DIMENSIONS IN INCHES A
IF MOUNTING CLEARANCE DETAILS ARE REQUIRED, CONSULT FACTORY.

617429-501
MAXIMUM PERMISSIBLE SHAFT RUNOUT WHEN MEASURED AT END OF
STANDARD SHAFT EXTENSION IS .08 MM T.I.R. TO 127 MM DIA. CUSTOMER IS RESPONSIBLE FOR DETERMINING THAT MOTOR PERFORMANCE IS SUITABLE IN THE APPLICATION.
SHEET NUMBER REV. DESC: CHANGE BA FROM 6.76 TO 6.62
2 OF 2 REV: B VERSION: 02 REVISED: 01:11:16 04/14/2014 TDR: 000000848770
MODEL NO. 617429-501 REF:
G405T/404T STD – FOOTED – XT/ECP SEVERE DUTY ENCLOSURE
617429-501
BY: MGHJMZ2 Material: C
8 7 6 5 4 3 2 1

P40G3909: 75HP,1185RPM,3PH,60HZ,405T,A40064M,TEFC Page 8 of 9


CUSTOMER INFORMATION PACKET ECP4404T - 75HP, 1185RPM, 3PH, 60HZ, 405T, A40064M, TEFC

A40WG0463: Electrical Design Page 9 of 9

You might also like