Professional Documents
Culture Documents
Ej 59358082
Ej 59358082
Ej 59358082
Version notes
Version Reason
01 Document updated for addition of keypad and display explanations of door HMI, number of LED
and display explanation of door drive DDE V15, checks before replacing of door drive DDE V15
and checking procedure of door drive DDE V15.
00 EMBD document created for troubleshooting.
[0000186709]
Press for > 5 s to start auto setup heavy door (learn trip to be executed with coupled
landing doors)
Close door
[0000186718]
2.2 LED status of door drive DDE V15 and their meaning
Error codes for door drive DDE V15 related to the elevator control:
Type of elevator control Number of error code of DDE V15
Bionic 315
368
371
MX7.2 800 ... 899
SC 800 ... 899
[0000106593]
[0000106624]
[0000186795]
► Make sure that each cable of the door drive DDE V15 is not damaged.
► Make sure that each cable or contact bridge are correctly connected to the door drive DDE V15.
[0000186794]
► Make sure that the main power on the door drive (JHCT) is ON (I).
► Make sure that the voltage of DDE V15.X5 plug (24 V DC) is 24 V DC ±5 %. Use a voltage meter.
[0000186719]
► Make sure that the COM LED on door HMI is green and ON.
[0000186793]
► Make sure that the COM LED on door HMI is green and ON.
↳ If the status is red, then the DDE V15 is in status fault.
► Switch OFF the main switch JHCT.
[0000186720]
[0000186792]
► Change the value of parameter 169 from 0 to 1 by using control HMI, in order to restore all door default
parameters.
[0000186791]
[0000186790]
[0000186721]
If DDE V15 is still not functioning correctly after performing all the above steps, you may file a claim.