Professional Documents
Culture Documents
Elitech Data Logger Catalogue 2022
Elitech Data Logger Catalogue 2022
About Us
International Certification
Elitech Technology, Inc.
ISET S.r.l.
Elitech is headquartered in San Jose, California, USA and has subsidiaries in China, UK and
Sede Legale e Uffici Cap. soc. i.v. € 10.200,00
Via Donatori di sangue, 9 - 46024 Moglia (MN) Cod. Fisc. e P.IVA 02 332 750 369
Tel. e fax +39 (0)376 598963 Reg. Imprese 02 332 750 369
iset@iset-italia.com www.iset-italia.eu REA MN 0221098
CERTIFICATE OF COMPLIANCE
Brazil with agents around the world. We have designed and manufactured all kinds of cold
Certificado de Conformidade - Сертификат соответствия - Konformitätserklärung
chain data logger and monitoring system for 27 years. Our advanced 20,000 m2 manufacturing
Jiangsu Jingchuang Electronics Co.,Ltd SCC(17)-60423A-10
No.1 Huangshan Rd. Tongshan Economic China CEPREI (Sichuan) Laboratory
Development Zone Xuzhou Jiangsu China
plant in Jiangsu, China makes the fast delivery possible on large order. 5) PRODUCT CHARACTERISTICS: Single-use Temperature Data Logger
MODEL(S): RC-5+
REMARK: The verification has been carried out on a voluntary basis. We attest that a TCF is in place. The
product(s) satisfies the requirements of the Certification Mark of ISET, in reference to the above list standard(s).
More than 10 million data logger products are sold every year to over 100 countries around the
The above compliance mark can be fixed on the product(s) according to the ISET regulation about its release. This
verification doesn’t imply assessment of the production and the product(s).
Notice of the CE marking: The label of the CE marking: Not less than 5mm height. Before
putting the product(s) into market, CE marking and EC declaration are duties of the
manufacturer. The manufacturer is responsible to start the CE marking certification procedure
and to perform all the activities according to the regulation.
world. Our 2000 m2 professional testing laboratory has been used to guarantee the quanlity of
CERTIFICATION MANAGER:
every Elitech product and the transportation risks of every stage are under control for our global
partners in cold chain related products and services. FDA 21 CFR Part 11 CE RoHS System Certification
In addition, we design and manufacture private label products for large OEM or ODM
customers and distributors. Designs are based on our technologies or technologies
developed specifically for unique customers.
www.elitechlog.com www.elitechlog.com
About Us
Production Center
Table of
CONTENTS
Test Laboratory
Elitech iCold 1-4
Cold Chain
Multi-Use Data Logger 15-21
www.elitechlog.com www.elitechlog.com
1/2
PC
Detailed Functions
● Real-Time Monitoring
Take control of goods information anywhere at any time, including temperature, humidity
Elitech software focuses on cold chain data management and analysis. It helps users to and real-time location.
comply with the local industry standards and regulations, and improve cold chain
quality and performance. Elitech software provides real-time monitoring, parameter
configuration, alarm notification, data analysis, report download and other functions
that can meet various requirements in different applications.
● Historical data record and query, data analysis report export Generate the device's track and routes in the time period according to its location L og I n ter v a l:
T im e Z on e: (g m t+ 0 8 :0 0 )s h a n g h a i
U p loa d I n ter v a l: 5 m in 2022-03-14 10:28:30
2022-03-14 10:30:30
23.1℃
23.4℃ Jing Wei L u, Tong S han Qu, Xu ...
● Electronic signature and endorsement for FDA CFR 21 Part 11 information. P r ob e1 Tem p er a tu r e S ta tis tic s
M ax: 2 3 .4 ℃ S ta r t T im e: 2 0 2 2 -0 3 -1 4 0 0 :0 0 :3 0
M in : 2 2 .1 ℃ S top T im e: 2 0 2 2 -0 3 -1 4 1 0 :3 0 :3 0
Avg : 2 2 .4 ℃ L og T im e: 10H 30M 0S
U p p er L im it: 1 0 .0 ℃ MK T: 2 2 .4 ℃
L ow er L im it: -1 .0 ℃ T ota l: 316
23.4
20
Software(PC)
15
ElitechLog
10 10
● Export data and generate analysis reports
● Data analysis in parallel for multiple devices 5
L og T im e
www.elitechlog.com www.elitechlog.com
3/4
APP
ElitechLog ● Graph
Display the selected or historical data in graph. Up to 10 datas can be displayed in the
● Multiple Routes Graph
Display graph & data analysis for multiple routes.
graph simultaneously, it is convenient for users to compare temperature and humidity
● Real Time Monitoring ● Data Query & Printing ElitechLog is compatible with RC/LogEt series data loggers. It supports parameter changes of multiple curves. The graph supports stepless zooming and dragging, and user
Check device data and status anywhere Support historical data query, graphic settings, data download, report generation and export, and helps to judge the compliance can click on the button in the upper left corner of the graph to zoom in, zoom out and
and anytime. analysis and data report printing via and effectiveness of shipments in the logistics process. The LogEt series drag the curve.
Bluetooth printer. (Bluetooth-enabled) supports data storage on Cloud with Elitech app. It complies with
FDA CFR 21 Part 11 requirements and supports Win and MAC versions.
PC
Detailed Functions
● Statistics
Read the current logger’s status and parameters. Summarize and display the status
information (alarm value, maximum and minimum value, start time, stop time, etc.).
● FDA Log
Display and trace the data in compliance with FDA standards, including account (user
login, logout, edit, lock), endorsement (unlock, add, edit, delete and modify), data( read,
save, import, and export), and the software system modification, etc.
● Parameter Settings
Read the logger's parameters and synchronize the current or latest parameters settings
to the page display, or set the parameters manually and save to the logger.
● Endorsement
Display and trace user's endorsement on the current data, including time, content,
endorsement account information, etc.
www.elitechlog.com www.elitechlog.com
5/6
RCW-360 is a wireless temperature and humidity monitor with 4G/Wi-Fi version. Its • Real-time recording and monitoring of temperature and humidity
• App and Email alarms from Cloud; Audible and visual alarm from device Technical Specifications RCW-800W-TDE RCW- 800W-THE Overview
low power consumption features long standby time and it designs for multiple
• Multiple installation and power supply methods, flexible to be installed anywhere RCW-800W series is a IoT recorder that communicates through WIFI network, which
installation methods that can be widely used in various temperature and humidity Communication mode WIFI
• Elitech Cloud supports parameter configurations, graph analysis, report export and etc
monitoring scenes. is used for real-time monitoring, recording, alarming and data uploading of ambient
Measurement range Temperature:-40℃~80℃ Humidity:0%RH~100%RH
• Unlimited Cloud storage with additional local storage of 20,000 points if off-line
tempera ture/humidity. The recorder is mainly composed of a temperature/humidity
• 4G versions support LBS (location-based service) positioning Temperature accuracy ±0.5℃(-20℃~40℃);±1℃(others)
sensor and a host instrument. It directly transmits the measured value to the Elitech
Humidity accuracy ±5%RH(RCW-800W-THE)
Technical Specifications RCW-360-THE RCW-360-TH cold cloud through the Wi-Fi network. It can be stored in the Elitech cold anytime,
Resolution 0.1℃; 0.1%RH(RCW-800W-THE) anywhere through mobile phones and PCs with Internet access functions. View and
Power supply 5V/1A(DC) 5V/1A(DC)
Temperature measuring range -40℃~+80℃ -20℃~+70℃ Recording interval 1-1440 min (default 5min) analyze the data in the cloud platform. After the limit is exceeded, the alarm can be
Temperature accuracy ±1.0℃(-25℃~0℃); ±0.5℃(0℃~40℃);±2℃(others) ±1.0℃(-25℃~0℃); ±0.5℃(0℃~40℃);±2℃(others) Storage capacity 20,000 sent in time through SMS, email and other methods.
Humidity measuring range 10%~95% 10%~95%
Storage mode cyclic storage
Humidity accuracy ±5%RH ±5%RH
sensor SHT31 HDC1080 Battery 5V/1A、2000mah
Features
Logging interval 5 min to 24 hr. 5 min to 24 hr. Battery life More than 7 days(@25℃,uplode interval 5 min)
● Small size, stylish shape, magnetic tray design, easy to install
Memory capacity 32,000 points for each channel(Max) 32,000 points for each channel(Max)
Indicator Alarm indicator, charging indicator ● Large-size TFT color screen display
Communication interface 4G/Wi-Fi(2.4G) 4G/Wi-Fi(2.4G)
Alarm LED、messages、APP push、email ● Built-in rechargeable lithium battery, can still provide real-time data upload for a
Alarm output Led,Buzzer, APP, E-mail push Led,Buzzer, APP, E-mail push
Screen TFT screen long time after power failure
Battery 3.7V lithium battery 3.7V lithium battery
Wi-Fi:30days (@25℃, Logging interval=10min) Wi-Fi:30days (@25℃, Logging interval=10min)
● The product is suitable for warehouses, cold storage, refrigerated trucks, cool
Protection class IP50
Battery life
4G:15days (@25℃, Logging interval=10min) 4G:15days (@25℃, Logging interval=10min) cabinets, medicine cabinets, freezer laboratories and other scenarios
Specification 110mm*78mm*27mm
www.elitechlog.com www.elitechlog.com
7/8
Channel Internal - Single T & Single H External - dual T External - dual T & dual H External - dual T
Temperature
-20℃~60℃ -200℃~150℃ -40℃~80℃ -40℃~80℃
measuring range
Humidity
measuring range 0%RH~100%RH / 0%RH~100%RH /
Temperature
measuring range ±0.5℃ ±0.5℃ ±0.5℃ ±0.5℃
RCW-360 Plus
Memory capacity 100000 100000 100000 100000
Overview
Alarm type Buzzer Buzzer Buzzer Buzzer
Elitech RCW-360Plus is a real-time temperature and humidity data logger featured with a large
TFT sreen with LBS function. It is widely used in the cold chain monitoring solutions, such as
Alarm mode SMS APP E-mail SMS APP E-mail SMS APP E-mail SMS APP E-mail
transportation and storage.
3.7V 5000mAh 3.7V 5000mAh 3.7V 5000mAh 3.7V 5000mAh
Battery
rechargeable lithium battery rechargeable lithium battery rechargeable lithium battery rechargeable lithium battery
Optional
www.elitechlog.com www.elitechlog.com
9/10
1000 meters
(Used with RCW-3200 Sensors) Maximum Adapter connected 100 Pieces
mobile APP, etc. The system uses various transmission technologies (LORA, GPRS, WIFI) to realize network monitoring of environmental temperature and humidity.The system can deploy Product Size 130mm*130mm*35mm
wireless probes according to the location of the monitoring points, and select GPRS or WIFI to connect to the cloud platform according to the local environment. The wireless collector RCW-3200
Model Built-in Temp & Humi External Temp & Humi
uploads data in the same wireless way, and the user views the data in real time through the browser or the intelligent terminal.The cloud platform can also be used for temperature and
Network Lora Lora
humidity data analysis, report export, historical data query, etc.
Sensor Type Temp and humi integrated sensor Temp and humi integrated sensor
www.elitechlog.com www.elitechlog.com
11/12
Single-Use temperature indicators iOS, Android APP Support Single-Use Data Logger
Ti Series Technical Specifica�ons RC-17/RC-17N
NFC Memory 3800(MAX) NFC
Teasuring Range -30℃-60℃
Overview Accuracy ± 0.5℃(-20℃~40℃), ±1℃(others)
This is a temperature tag with NFC communica�on func�on,which is mainly used in Sensor Built-in NTC Technical Specifications
applica�on scenarios such as blood.vaccines, biological prepara�ons,biological
Sampling Interval 1min(standard,others on request)
medicines, cold chain foods,and precision instruments.The product is light weight,thin Temperature Range -30℃ ~ 70℃
and compact,and the start-stop opera�on with break-tab is simple and reliable. It is Recording Interval 12h(standard,others on request)
Resolution 0.1℃
suitable especially for the smallest packaging products. It supports any handhold devices Start Delay 30 min(standard,others on request)
Storage Temperature -30℃ ~ 70℃
with NFC func�on,such as a mobile phone to retrieve key data during temperature
monitoring.and long ba�ery life to ensure data recording during the en�re monitoring
Start Mode Break to start iOS, Android APP Support Measurement Accuracy 0.5℃/0.9℉(-20℃ ~ 40℃);1℃/1.8℉(Other)
process. Stop Mode Break to stop
Sensor Built-in NTC
Alarm threshold Op�onal,upto6 points Overview
Storage capacity 16000points(Max)
Instruc�ons RC-17/RC-17N is mainly used for temperature monitoring and recording in food and
Data Interface NFC
Place the phone near Logging life 6,15,30,60,90,120,180days(customized)
Break to Paste the data logger Break to medicine storage and transportation environment, such as refrigerated bags,
start recording label onto the stop recording
to Ba�ery life 3 years(normal temperature) refrigerated trucks, containers, etc. This product is connected to the computer
the data logger label to Alarm Type single(Sin), accumulative(Cum)
packaging box
retrieve data Shelf life/Ba�ery 4 years/CR2032 lithium ba�ery through USB, and the recorded data is directly output as PDF report;Built-in
Data Transport USB 2.0/ NFC
temperature probe, powered by CR2450 wide temperature lithium battery,
Report Genera�on PDF/Excel report
waterproof grade up to IP67.Products come with a bar code. Report Type PDF Report
Protec�on Class IP54
RC-17N supports any handhold devices with NFC function, such as a mobile phone Power Type Built-in CR2450 lithium battery
EMS204000003
EM
S20
400
000
EM
S204
0000
APP NFC
Weight Approx.llg
3
03
www.elitechlog.com www.elitechlog.com
13/14
Features
● High-precision temperature/humidity sensor, accuracy heightened to ±0.5℃, 3%RH
● LCD screen for more powerful and intuitive indication
● 3. Configuration through free software ElitechLog and cloud platform Elitech iCold
Glog 2
● Battery life up to 180 days, shelf life up to 2 years
● Up to IP67 waterproof grade(Except LogEt 1 TH)
Technical Specifica�ons ● Complies with CE (EN12830), RoHS and FDA (21CFR)
LogEt 1 LogEt 1 TH
Temperature Measurement Range -30℃ to 55℃ Resolu�on: 0.1℃ Technical Specifications LogEt 1 LogEt 1 TH
Accuracy 0.5℃/0.9℉ (-20℃~40℃) ; 1℃/1.8℉ (others) Recording Options Single-Use Single-Use
Overview Sensor Internal NTC temperature sensor and light sensor Temperature Range -30℃ to 70℃ -30℃ to 70℃
Glog 2 is a single-use data logger that records real-�me temperature, posi�on and Ba�ery Life
1
20 days (5 minute logging interval and 60 minute upload interval) Humidity Range - 0-100% RH
illumina�on. Quickly started by pulling out ba�ery insulator strip that ensure logis�cs Temperature Accuracy ±0.5℃ ±0.5℃(-20℃/+40℃);±0.5℃(other range)
Start Delay 2 30 minutes (customizable)
efficiency and quality. Humidity Accuracy - ±3%RH(25℃,20%RH to 80%RH),±5%RH(other range)
Logging Interval 3 5 minutes (customizable)
Resolution 0.1℃ 0.1℃,0.1%RH
Func�ons Upload Interval 4 60 minutes (customizable) Data Storage Capacity 16,000 readings 16,000 readings
• Easy to ac�vate, quickly create shipments for monitoring Shelf Life 1 year stored at room temperature Shelf Life/Battery 2 years'/CR2450 button cell 2 years'/CR2450 button cell
• Check temperature and posi�on in real-�me through S/N Storage Temperature +15℃~30℃ Recording Interval 12 minutes(standard, others on request) 12 minutes(standard, others on request)
• Light sensor to determine viola�on door opening opera�ons during transporta�on Recording Duration up to 120 days²(standard, others on request) up to 120 days²(standard, others on request)
Protec�on Grade IP65
Reprogrammable With free Elitech Win or MAC software With free Elitech Win or MAC software
• Auto email alert in case of over temperature limit
Startup Mode Button or software Button or software
• Download PDF and Excel report from Elitech Glog 1 Ba�ery Life: The es�mated opera�on days of the logger(based on certain condi�ons).
Stop Mode Button, software or stop when full Button, software or stop when full
• Ba�ery rechargeable, shelf life up to 2 years 2 Start Delay: A�er start delay �me elapses, the ac�vated logger will start logging. Protection Class IP67 NONE
3 Logging Interval: The interval between two readings a�er the logger starts logging. Certifications FDA EN12830, CE, RoHS FDA EN12830, CE, RoHS
4 Upload Interval: The interval between two readings that being uploaded to the Cloud. 1.Depending on optimal storage conditions(15℃ to 23℃/45% to 75% RH) 1.Depending on optimal storage conditions(15℃ to 23℃/45% to 75% RH)
2.Depending on application temperature(very low/ high temperatures may shorten it) 2.Depending on application temperature(very low/ high temperatures may shorten it)
www.elitechlog.com
15/16
Temperature Range -30℃~70℃ -40℃~85℃ -30℃~70℃ -40℃~85℃ ±5%RH(other range) ±5%RH(other range)
Resolu�on 0.1℃,0.1%RH 0.1℃ 0.1℃,0.1%RH 0.1℃ 0.1℃
Humidity Range / / 0~100% RH 0~100% RH
Data Storage Capacity 16,000 readings
Data Interface USB USB USB USB Shelf Life/Ba�ery 2 years1/ER14250 3.6V lithium ba�ery
Accuracy ±0.5℃ (-40℃~85℃); ±3%RH (25℃: 20%~80%), ±5%(others) Recording Interval 10 minutes(standard, others on request)
So�ware PDF /ElitechLog Win or Mac (latest version) —
Resolution Temperature: 0.1℃ Humidity: 0.1%RH
Report Genera�on Automa�c PDF report —
Memory 32000 points (MAX)
Password Protec�on Op�onal on request
Logging Interval 10s ~ 24h Alarm Configura�on Op�onal, up to 5 points
Report Type PDF format Reprogrammable With free Elitech Win or MAC so�ware
Startup Mode Bu�on or so�ware
Battery CR2450 3.0V wide-temperature button cell
Stop Mode Bu�on, so�ware or stop when full
Battery Life 2 years for storage and use; Cumulatively 180 days at 10 min logging interval Protec�on Class IP65
Protection Level IP65 Cer�fica�ons FDA EN12830, CE, RoHS
www.elitechlog.com www.elitechlog.com
17/18
Software PDF /ElitechLog Win or Mac (latest version) Technical Specifica�ons GSP-6/6G GSP-8
Func�ons
Report Generation Automatic PDF report Recording Options Multi-Use Multi-Use
● Bluetooth® access data logger outside the package anytime anywhere, no pairing
Password Protection Optional on request Temperature Range -40℃~85℃ -20℃~60℃(internal sensor); -40℃~85℃(external probe)
required
Connection Interface USB 2.0, A-Type,bluetooth Humidity Range 0~100% RH 0~100% RH
● Auto encrypted PDF report with password protection function Temperature Accuracy ±0.5℃(-20℃/+40℃); ±1.0℃(other range) ±0.3℃(-20℃/+40℃); ±0.5℃(others)
Alarm Configuration Optional, up to 5 points Humidity Accuracy ±3%RH(25℃,20%RH to 90%RH); ±5%RH(other range) ±3%RH(25℃,20%RH to 90%RH); ±5%RH(others)
● Built-in USB port allows quick access to PCs and ElitechLog software
Reprogrammable Elitech APP & Elitechlog Resolution 0.1℃,0.1%RH 0.1℃, 0.1%RH
● Multiple configuration, downloading, management and sharing via Elitech app
Startup Mode Button or software Data Storage Capacity 16,000 points 100,000 points
(iOS/Android) Shelf Life/Battery 2 years' ER14505 Rechargeable 18650 lithium battery
Stop Mode Button, software or stop when full Recording Interval 15 minutes(standard, others on request) 15 minutes(standard,others on request)
● Unlimited storage on Elitech Cloud
Protection Class IP65 Alarm Configuration Optional, only 2 points Optional, up to 5 points
● Compliance with CE (EN12830), RoHS, BQB and FDA (21CFR)
Certifications FDA EN12830, CE, RoHS Reprogrammable With free Elitech Win or MAC software Auto PDF report,PDF/EXCEL/TXT by ElitechLog software
Stop Mode Button, software or stop when full Button,software or stop when full
1.Depending on optimal storage conditions(15℃ to 23℃/45% to 75% RH) Certifications FDA EN12830, CE, RoHS FDA EN12830, CE, RoHS
www.elitechlog.com www.elitechlog.com
19/20
www.elitechlog.com www.elitechlog.com
21/22
Main Features Type Memory Connectivity Other Features
Key
e)
rang
)
Sensor:
nge
,
25℃
er ra
1=Internal
ther
RH(
ent
(oth
E=External
H(o
Elitech Products &
±3%
rem
ent
5%R
y
1.0℃
Features Matrix Battery:
urac
y
m
su
tivit
racy
tion
sure
H),±
Mea
℃);±
F=Fixed
Acc
nec
u
0%R
otec
vity
Mea
+40
Acc
vity
ture
R=Replaceable/
ture
Con
ecto
s
ecti
Log
ogs
0℃/
d Pr
ogs
ecti
to 9
lay
idity
idity
pera
pera
Rechargeable
ion
g
oth
n
F
00 L
Disp
chlo
,000
00 L
Multi-Use Data Logger
Con
onn
℃(-2
o PD
wor
Con
RH
olut
Hum
Hum
zer
ery
sor
Tem
to
Tem
ge
ge
d
~32,0
Elite
4G C
20%
Blue
Clou
Pass
~16,0
NFC
~100
LCD
Buz
Batt
Ran
USB
Sen
Ran
±0.5
Res
Aut
Wifi
Multi-Use Data Loggers Product Model
✓ ✓ ✓ ✓ ✓ ✓
RC-4 Series
Temperature internally RC-4 -40° to +85°C E R 0.1°C
Temperature and Humidity internally RC-4HC -40° to +85°C 0~100%RH E R ✓ ✓ 0.1°C 0.1%RH ✓ ✓ ✓ ✓ ✓
✓
Technical Specifications
✓
RC-4 RC-4HC
Temperature internally RC-5+ -30° to +70°C E R 0.1°C ✓ ✓ ✓ ✓ ✓
Recording Options Multi-Use Multi-Use Temperature internally RC-51 -30° to +70°C I R ✓ 0.1°C ✓ ✓ ✓ ✓ ✓ ✓
Temperature and Humidity internally RC-51H -30° to +70°C 10~95%RH I R ✓ ✓ 0.1°C 0.1%RH ✓ ✓ ✓ ✓ ✓ ✓
Temperature Range -30℃ to 60℃ (Internal sensor) -30℃ to 60℃ (Internal sensor)
Temperature and Humidity external GSP-6 -40° to +85°C 0~100%RH E R ✓ ✓ 0.1°C 0.1%RH ✓ ✓ ✓ ✓ ✓
-40℃ to 85℃ (optional external sensor) -40℃ to 85℃ (optional external sensor)
external-85℃ LogEt 8 PTE -95° to +150°C E R ±0.3°C 0.1°C ✓ ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓
Humidity Range - 0 ~ 100% RH
Temperature internally LogEt 8 BLE -30° to +70°C I R ±0.3°C 0.1°C PDF file
Temperature Accuracy ±0.5℃(-20℃/+40℃); ±0.5℃(-20℃/+40℃) Temperature External Tlog 10E -40° to +85°C E R ±0.3°C ✓ 0.1°C ✓ ✓ ✓ ✓ ✓
±1.0℃(other range) ±1.0℃(other range) Tem & Hum External Tlog 10EH -40° to +85°C 0~100%RH E R ±0.3°C ✓ 0.1°C 0.1%RH ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓ ✓
Resolution 0.1℃ 0.1℃,0.1%RH
Temperature NFC RC-17N -30° to +70°C I F 0.1°C
Data Storage Capacity 16,000 readings 16,000 readings Temperature internally LogEt 1 -30° to +70°C I F ✓ 0.1°C ✓ ✓ ✓ ✓ ✓ ✓
Shelf Life/Battery 1 year'/CR2450 button cell 1 year'/CR2450 button cell Temperature internally LogEt 1TH -30° to +70°C 0~100%RH I F ±0.3°C ✓ 0.1°C 0.1%RH ✓ ✓ ✓ ✓ ✓ ✓
Overview
Real Time Data Loggers
Recording Interval 15 minutes(standard, others on request) 15 minutes(standard, others on request)
RC-4 series are Elitech conventional temperature/humidity data loggers, support Temperature and Humidity external RCW-360 THE -40° to +80°C 10~95%RH E R ✓ ±5%RH 0.1°C ✓ ✓ ✓ ✓ ✓
Report Generation PDF&Excel report by Elitech software PDF&Excel report by Elitech software
external temperature sensor and buzzer alarms. This series is world-wide remote Temperature and Humidity internally RCW-360TH -20° to +70°C 10~95%RH I R ✓ ±5%RH 0.1°C 0.1%RH ✓ ✓ ✓ ✓ ✓
✓ ✓ ✓ ✓ ✓ ✓
acess to various applications like life sciences, food, shipping, logistics, and Alarm Configuration Optional, only 2 points Optional, only 2 points
Temperature and Humidity internally RCW-360P-TH -20° to +60°C 0~100%RH I R ±5%RH 0.1°C 0.1%RH
pharmaceutical industries. Reprogrammable With free Elitech Win or MAC software With free Elitech Win or MAC software Temperature and Humidity external RCW-360P-THDE -40° to +80°C 0~100%RH E R ✓ ±5%RH 0.1°C 0.1%RH ✓ ✓ ✓ ✓ ✓
Features Startup Mode Button Button Temperature and Humidity external RCW-800 W -40° to +80°C 0~100%RH E R ✓ ±5%RH 0.1°C 0.1%RH 20,000 ✓ ✓ ✓ ✓
● Internal temperature/humidity sensor, accuracy up to ±0.5℃, ±3%RH Stop Mode Button, software or stop when full Button, software or stop when full Product Model Features Key
Elitech dataloggers are named using the naming conventions below. Please note
● Double alarm thresholds configurable with buzzer alarm notification Certifications FDA EN12830, CE, RoHS FDA EN12830, CE, RoHS
that these features may not be accurate, so please to check the product
● USB cable included, no reader required to connect with PC and ElitechLog software specifications before purchase.
RC-4
● External temperature sensors applicable to various scenarios (optional) T Temperature H Humidity
1.Depending on optimal storage conditions(15℃ to 23℃/45% to 75% RH) I Internal Sensor E External Sensor
● Wall-mounted in various locations with multiple mounting hardware(optional) RC-4HC R Replaceable/Rechargeable F Fixed Battery
● Compliance with CE (EN12830), RoHS and FDA (21CFR) 1.Depending on optimal storage conditions(15℃ to 23℃/45% to 75% RH)
D Display WIFI WiFi Enabled
U USB