Remote Box

Note: Before take apart inverter, please confirm all power cords are disconnected!
1. Check cable
Remove the two
screws and open the
bottom cover.

Please use the


multimeter to measure
the cable is short.

1
V201609A
Remote Box

Please use the


multimeter to measure
the cable is short.

1 8 1 8

If both cable checks


are normal, reconnect
and turn on the unit to
check communication
between inverter and
remote display panel.

2
V201609A
Remote Box

2. Check component
Loosen the screw on
the bottom of LCD
panel and push down
the panel from the
bottom case. Then,
pull out the cable from
the remote
communication port.
Remove the 4 pcs of
screws on the case.

Take out the PCBA


board.

3
V201609A
Remote Box

Please use the


multimeter to measure
the Resistor the main
board component.

Parts Attribute Reference values


C2 Resistor 1 to 2: 1000KΩ
C4 1 to 2: 5KΩ
F4 1 to 2: 1Ω
F3 1 to 2: 1Ω

4
V201609A
Remote Box

Please use the


multimeter to measure
the Photo coupler the
communication board
component.

Parts Attribute Reference values


A Optocoupler 1 to 2: 1.08Vdc
A 2 to 1: 0.6Vdc
B 2 to 1: 1.08Vdc