CUSTOMER SERVICE INSPECTION REPORT

Company Name: F E S T Engineering and Services (Thailand) Co., Ltd.


Main Office 5/5 Kamphaeng Road Boyang district Mueang Songkhla, 90000 Thailand. Tel: 074-800-362 Email: sales@fest-thailand.com
CUSTOMER: SAPURA ENERGY (T17) DATE: 16 January.2023.
COMPONENT: DERRICK CYLINDER PO. NO.: 2501-22-00816 TYPE: High-Pressure Cylinder
MANUFACTURE: Jiangsu Hengli FEST JOB NO: FEST22-119 P/N: 0519-36159988 S/N.: N/F

INITIAL FINDING BEFORE AFTER


GENERAL INSPECTION FOUND:
1. RUST INHABITED ON ROD
CYLINDER & CASE.
2. EVIDENT OF OIL LEAK FROM
DUST SEAL.
3. CYLINDER CASE COLOUR PEEL
OFF.

CORRECTIVE FINDINGS BEFORE AFTER


DISASSEMBLY AND REPAIR OF CYLINDER
1. REPLACEMENT SEAL KIT
2. RECHROMED CYLINDER ROD
3. CLEAN & REPAINT THE CASE

FEST-TECH-2022-001
CUSTOMER SERVICE INSPECTION REPORT

DERRICK CYLINDER HYDRO-STATIC TEST

FEST-TECH-2022-001
CUSTOMER SERVICE INSPECTION REPORT

FINAL INSPECTION:

NO EVIDENCE OF LEAKAGE DURING THE TESTING PERIOD.

Important Note:
1. FEST Thailand only offers One Month’s Warranty
2. The Warranty validity W.E.F activates from 14 JAN. -14 FEB. 2023 of the final inspection.

PREPARED BY

Signature

Mr. Worawan Nuanplean


Marketing and Sales/ Technical Engineer

FEST-TECH-2022-001