12V 150AH
Deep Cycle
Specifications
Nominal Voltage 12V
Nominal Capacity 20HR) 150AH
Terminal Type Standard Terminal F10
Optional Terminal F11
Container Material Standard Option ABS
Flame Retardant Option (FR) UL94-V0
Rated Capacity 20hr, 1.80V/cell, 25°C 156.0 AH/8.04A
10hr, 1.80V/cell, 25°C 150.0 AH/15.0A
5hr, 1.75V/cell, 25°C 131.6 AH/26.3A
1hr, 1.60V/cell, 25°C 96.9 AH/96.9A
Max Discharge Current 1500A (5s)
Internal Resistance 2.5m
Discharge Characteristics Operating Temp. Range Discharge: -20 ~ 55°C
Charge: 0 ~ 40°C
Storage: -20 ~ 50°C
Nominal Operating Temp. Range 25 ± 3°C
Cycle Use Inital Charging Current less than 45.0A.Voltage
14.4V ~ 15.0V Temp. Coefficient -30mV/°C
Standby Use No limit on Initial Charging Current Voltage
13.5V ~ 13.8V Temp. Coefficient -20mV/°C
Capacity affect by Temperature 40°C 103%
25°C 100%
0°C 86%
Design Floating Life at 20°C 15 Years
Self Discharge Ultracell batteries may be stored for up to 9 months at 25°C(77°F) and then a refresh charge is required.
For higher temperatures the time interval will be shorter.
Dimensions
F10 Terminal
17 [0.669] 8 [0.315]
2
8.5 [0.335]
170
2
6 [0.236]
240
16 [0.63]
240
485 2
1 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
ISO9001
www.ultracell.co.uk
UCG150-12
12V 150AH
Deep Cycle
1C 60 0.06C 2.2
2C
AFTER 50% DISCHARGE
9.0
40 0.04C 2.1 AFTER 100% DISCHARGE
C=C20
8.0
C= C20 20 0.02C 2.0
CHARGING CURRENT
1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 0 0C
min H
0 4 8 12 16 20 24 28 32
Discharge Time Charging Time (hours)
Temperature Effects in Relation to Battery Capacity Effect of Temperature on Long Term Float Life
110
100 14
Life expectancy(year)
90 12
Available capacity / %
Charging voltage
10 2.25V/cell
80
70
5
60
C20
50 C10 2
C5
40 C3
C1
30 0.5
-20 -15 -10 -5 0 5 10 15 20 25 30 20 30 40 50 O0 C
68 86 104 122 F
Battery temperature/ Battery temperature
Cycle Life in Relation to Depth of Discharge General Relation of Capacity VS. Storage Time
Residualaveragecapacity in % of C 20
Acc.t o IEC89 6-2 (25 0 C / 77 0F) 120
100
90
100
Extracted capacity in %
80
Available capacity %
70 80
60
10
50
60
40 30
40 20
40
30
20
20
10
400 800 120 0 160 0 200 0 240 0 280 0 320 0 360 0 400 0 0 5 10 15 20 25
2 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom
Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: info@ultracell.co.uk
ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE
ISO9001