Bilbaraka For Engineering and Consultancy Services ‫ﺑﺎﻟﺒﺮﻛﺔ ﻟﻠﺨﺪﻣﺎت اﻟﮭﻨﺪﺳﯿﺔ واﻹﺳﺘﺸﺎرﯾﺔ‬

Engineering Feasibility, Evaluation and Follow up Studies


Projects Management and Construction Supervision & Management
Structural Analysis and Design For Multi Storey Buildings
Preparation of Tender Documents and Project Management Plans
(232) ‫ﺑﯿﺖ ﺧﺒﺮة‬
Consultant Engineer- EC/ER/CE/529

Dated: 14th of October 2022. Ref././Res./2022

Attention : Mr. Khalid Ibrahim


Dear sir:

Subject: Structural Analysis and Design Assessment to the existing building


Foundation +Short columns and G.F. with an additional floor

With regards to the previous meeting between our staff and your representative, and
the scope of work which has been explained by you to carry out structural analysis, design
assessment and substructure assessment to the above mentioned existing building which is
composed of G.F. and to recommend whether additional floor could be added or not, and
what remedies to be done for such an additional floor, we herein specify the work as follows:
1. Check the possibility of water seepage under building foundation / assessment.
2. Ultra sonic and core test to substructure concrete and superstructure.
3. Cover meter to determine reinforcement distribution, numbers and types.
4. Reinforcement tensile, shear and bending test, samples will be taken from the roof.
5. Plate bearing test to soil to determine the maximum possible bearing capacity
(confirmation).
6. Complete Structural model will be made to the building by using licensed software.
7. Loads as dead, live, superimposed, utilization live load, wind and seismic (zone 2b,
0.15g) loads will be considered as per the international codes, along with BS standards
combinations.
8. Settlement calculations together with allowable bearing capacities will be calculated to
determine safe and adequate foundations dimensions and reinforcement.
9. Punching shear, one way shear, deflection and long term effects will be assessed.

Email: taha.elnour@gmail.com (00249912910731) :‫اﻟﺨﺮطﻮم ﺗﻘﺎطﻊ ش اﻟﺒﻠﺪﯾﺔ و ش ﻋﻄﺒﺮة ﻋﻤﺎرة اﻻﺧﻮة اﻟﻄﺎﺑﻖ اﻟﺮاﺑﻊ ﺗﻠﻔﻮن‬
Bilbaraka For Engineering and Consultancy Services ‫ﺑﺎﻟﺒﺮﻛﺔ ﻟﻠﺨﺪﻣﺎت اﻟﮭﻨﺪﺳﯿﺔ واﻹﺳﺘﺸﺎرﯾﺔ‬
Engineering Feasibility, Evaluation and Follow up Studies
Projects Management and Construction Supervision & Management
Structural Analysis and Design For Multi Storey Buildings
10.Short columns and ground floor /all columns will be carefully assessed.
11.Full analysis results will be tabulated; service and ultimate reactions will be estimated
for each element.
12.Building stability and max sway and drift will be calculated.
13.Full analysis report together with manual calculations will be submitted.
14.Recommendation will be given stating how to deal with the situation if an additional
floor could be added.
15.Recommendation in two options for concrete or steel floor will be stated with full
construction drawings; the possibility of adding a floor will be clearly stated.
16.The work will be completed and submitted as follows:
a. All Engineering tests will be done within (2) Weeks.
b. All the analysis and assessment/design work will be completed within (5 days).
c. Report will be submitted within a week.
d. Complete duration is (20) Days.
The total amount for the whole work including the testing, analysis, reports and drawings
is an amount of (12,000 USA$) only twelve thousands US Dollars, to be paid in two
instalments, 60% advance and 40% final upon submittal of all deliverables (concrete test
results, soil test results, structural report and drawings).
With best regards.

Eng. Taha Elnour Isshage, CEng. MIStructE. -UK, CEng. ASCE- USA
Consultant Engineer / 529-SDN