BOQ FOR CONSTRUCTION OF AUDITORIUM BUILDING

AUDITORIUM BUILDING
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
ITEMS BASED ON PWD SOR FOR BUILDING
WORKS, BHOPAL, 1.8.2014
Civil works
I - EARTH WORK
1 2.1/22 Surface dressing of the ground including removing
vegetation and in-equalities not exceeding 15 cm deep
and disposal of rubbish, lead upto 50 m and lift upto 1.5
m.
2.1.1 All kinds of soil 100
122.28 803.00
Sqm
2 2.8/23 Earth work m excavation by mechanical means
(Hydraulic Excavator)/ manual means in foundation
trenches or drains (not exceeding 1.5 m in width or 10
sqm on plan) including dressing of sides and ramming of
bottoms, lift upto 1.5 m, including getting out the
excavated soil and disposal of surplus excavated soil as
directed, within a lead of 50 m. (No extra lift is payable if
work is done by mechanical means)
2.8.1 All kinds of soil cum 2257.80 131.00
3 2.9/23 Excavation work by mechanical means (Hydraulic
excavator) / manual means in foundation trenches or
drains not exceeding 1.5 m in width or 10 sqm on plan
including dressing of sides and ramming of bottoms lift
upto 1.5 m, including getting out the excavated soil and
disposal of surplus excavated soils as directed, within a
lead of 50m.
2.9.1 Ordinary rock cum 677.34 216.00
2.9.2 Hard rock (requiring blasting) cum 120.42 452.00
2.9.3 Hard rock (blasting prohibited) cum 120.42 493.00
4 2.26/26 Extra for every additional lift of 1.5m or part thereof in
excavation. (No extra lift is payable ifwork is done by
mechanical means)
lift above 1.5m upto 3.0 m,
2.26.1 All kinds of soil cum 1444.99 30.00
2.26.2 Ordinary or hard rock cum 120.42 53.00
lift above 3.0m upto 3.1 m,
2.26.1 All kinds of soil cum 90.31 60.00
2.26.2 Ordinary or hard rock cum 120.42 106.00
5 2.10/23 Excavating trenches of required width for pipes, cables,
etc including excavation for sockets, and dressing of
sides, ramming of bottoms, depth upto 1.5 m including
getting out the excavated soil, and then returning the soil
as required, in layers not exceeding 20 em in depth
including consolidating each deposited layer by
ramming, watering, etc. and disposing of surplus
excavated soil as directed, within a lead of 50 m : (No
extra lift is payable if work is done by mechanical
means)
2.10.1 All kinds of soil
2.10.1.1 Pipes, cables etc, not exceeding 80 mm dia. RM 40.00 96.00
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not
RM 40.00 156.00
exceeding 300 mm dia.
2.10.1.3 Pipes, cables etc. exceeding 300 mm dia but not
RM 40.00 244.00
exceeding 600 mm.

6 2.11/16 Extra for excavating trenches for pipes, cables etc. in all
kinds of soil for depth exceeding 1.5 m, but not
exceeding 3 m.(Rate is over corresponding basic item
for depth upto 1.5 metre).
2.11.1 Pipes, cables etc, not exceeding 80 mm dia. RM 40.00 128.64
2.11.1.1 Pipes, cables etc. exceeding 80 mm dia. but not
RM 40.00 209.04
exceeding 300 mm dia.
2.11.1.2 Pipes, cables etc. exceeding 300 mm dia but not
RM 20.00 326.96
exceeding 600 mm.
7 2.25/26 Filling available excavated earth (excluding hard
rock/Ordinary rock) in trenches, plinth, sides of
foundations etc. In layers not exceeding 20cm in depth, cum 3747.95 72.00
consolidating each deposited layer by ramming and
watering, lead up to 50 m and lift upto 1.5 m.
8 2.27/26 Supplying and filling in plinth with crusher stone dust /
coarse sand under floors including, watering, ramming
cum 224.70 672.00
consolidating in layers not exceeding 20cm in depth and
dressing complete
9 2.28/26 Supplying and filling in plinth with hard muram hard
copra under floors including watering ramming
cum 674.10 471.00
cosolidating in layers not exceeding 20cm in depth and
dressing complete.
10 1.1/13 Transportation By Mechanical Transport including
loading, unloading and stacking.
TRANSPORTATION
1.1.2 Earth
1 km cum 10.00 139.47
1.1.4 Excavated rock
1 km cum 918.17 223.16

II - ANTI- TERMITE
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
1 2.32/27 Preconstruction antitermite treatment to the building
under construction by providing
Stage 1: Treating the bottom and the sides (upto 30cm
hight of the excavated trench @ 5 litter per sqm of the
surface area.
Stage 2: After masonry/RCC work, the backfill in the
immdiate contact with the foundation structure treatment
@ 7.5 litter per sqm. ofthe vertical surface ofthe
substructure for each side.
Stage 3: surface treatment by spreading emulsion over sqm 2247.00 136.00
the plinth area before laying the base concrete under
floors @ 5.0 litres/Sqm.
Stage 4: Pumping the emulsion in plinth masonry on
filling side at floor junction @.5 litres/Sqm. Stage 5:
Pumping the emulsion from outer side of the plinth belo
ground alround the masonry @ 5.0 litres/Sqm as per I.S.
8944 Emulsion. (1 Chlorpyrifos: 19 water) with five years
service guarantee (Measurements to be taken for plinth
area)
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
Note - Treatment should start when foundation trenches
and pits are ready to take bed concrete or leveling
course in foundations Laying of bed concrete should
start when the chemical emulsion has been absorbed by
the soil and the surface is reasonably dry.
Treatment should not be carried out when it is raining or
when soil is wet with rain or subsoil water. This also
applies to filled up soil within the plinth area before
laying the subgrade for flooring.

III-CONCRETE WORK
1 4.17/48 Making plinth protection 50mm thick of cement concrete
grade MIO over 75mm bed of dry metal ballast 40mm
nominal size well rammed and consolidated and filled
SQM 225.00 351.00
with sand including finishing the top smooth (with 20mm
nominal size graded stone aggregate.)

2 4.1/45 Providing and laying in position cement concrete of


specified grade excluding the cost of centering and
shuttering All work up to plinth level.
4.1.2 With 40mm nominal size graded stone aggregate.
4.1.2.1 M 15 - Grade concrete CUM 92.34 4403.00
4.1.2.2 Nominal Mix -1 Cement : 3 sand : 6 graded stone
CUM 457.55 3808.00
aggregate (M 10)

IV - RCC WORKS
1 5.27/70 Providing and laying in position machine batched,
machine mixed design mix M-25 grade cement concrete
for reinforced cement concrete work using cement
content as per approved design mix, including pumping
of concrete to site of laying but excluding the cost of
centring, shuttering, finishing and reinforcement,
including admixtures In recommended proportions as per
IS 9103 to accelerate, retard setting of concrete,
improve workability without impairing strength and
durability as per direction of Engineer-in-charge. (Note :-
Cement content considered in this item is 330 kg/cum
excess/ less cement used as per design mix is
payable/recoverable separately).
5.27.1 All works upto plinth level CUM 746.63 5641.00
5.27.2 All works above plinth level and upto floor five level. CUM 706.84 5757.00

2 5.28.2 Providing M-35 grade concrete instead of M-25 grade


BMC/RMC.
CUM 706.84 140.00
Note: Cement content considered in M-35 is @350
kg/cum)

3 5.16/68 Reinforcement for RCC work including straightening,


cutting, bending, placing in position and binding
including cost of binding wire upto floor two level
including all wastage etc. complete.
5.16.6 Thermo-Mechanically Treated bars.(TMT) KG 188951.3 62.90
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
4 5.17/68 Add extra for providing reinforcement above floor two
level for every additional floor or part thereof
First Floor KG 28989.48 0.01
Terrace Floor KG 1797.80 0.01
5 5.9/66 Centering and shuttering including strutting, propping
etc.and removal of form for :
A 5.9.1 Foundations, footings, bases of columns, etc. For
SQM 794.90 174.00
concrete up to plinth level.
B 5.9.3 Suspended floors, roofs, landings, balconies and access
SQM 2067.68 264.00
platform.
C 5.9.5 Lintels, beams, girders, bressumers and cantilevers. SQM 2370.40 227.00
D 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. SQM 950.42 356.00
F 5.9.7 Stairs, (excluding landings) except spiral-staircases. SQM 110.25 332.00
G 5.9.19 Weather shade, Chajjas, corbels etc., including edges SQM 1.62 451.00
H 5.9.15 Extra for shuttering in circular work or any other
geometrical shape (20% of respective centering and
shuttering items).
For 5.9.3 SQM 415.00 52.80
For 5.9.5 SQM 475.00 45.40
For 5.9.6 SQM 190.00 71.20
V - MASONRY WORK
1 6.5/85 Brick work with well brunt open bhatta, bricks, crushing
strength not less than 25kg /cm2 and water absorpt ion
not more than 20% in foundation and plinth ilc curing etc
complete.
6.5.1 Cement mortar 1:4 (1 cement: 4 sand) CUM 266.66 4347.00

2 6.6/85 Brick work with well brunt open bhatta, bricks, crushing
strength not less than 25kg / cnr' and water absorption
not more than 20% in superstructure above plinth level
and up to floor two level i/c curing etc complete.
6.6.1 Cement mortar 1:4 (1 cement: 4 sand) CUM 619.36 4541.00

3 6.11/58 Extra for brick work in superstructure above floor 2 level


for each floors or part thereof
Terrace Floor CUM 517.23 92.00
4 6.14/87 Providing half brick masonary with well burnt open
bhatta bricks crushing strength not less than 25 kg /cm2
and water absorption not more than 20% in
superstructure above plinth level and up to floor two
level
6.14.2 Cement mortar 1:4 (1 cement : 4 coarse sand) SQM 437.74 522.00
Providing and laying minimum 100mm thick autoclaved
aerated flyash cement concrete (AAC) masonry blocks in
super structure above plinth level up to floor two level in
5 6.16/8 CUM 100.00 5720.00
cement mortar 1:4 (1 cement : 4 sand) The rate includes
providing and placing in position 2 Nos. 8 mm dia
M.S.bars at every third course of masonry work.
6 6.18/88 Extra for providing and placing in position 2 Nos. 8mm
dia. M.S. bars at every third course of half brick SQM 437.74 127.00
masonry.
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
7 6.17/87 Extra for half brick masonry in superstructure, above
floor II level for every floor or part thereof respective
it
First Floor SQM 117.55 11.00
Terrace Floor SQM 10.00 22.00

VI -STEEL WORK
1 8.2/111 Designing, fabricating, testing, protection, installing and
fixing in position semi (grid) unitized system of
structural glazing (with open joints) for linear as well as SQM 250.00 2674.00
curvilinear portions of the building for all heights and all
levels, including
(A) Structural analysis and design and preparation of
shop drawings for the specified design loads conforming
to IS 875 part III (the system must passed the proof test
at 1.5 times design wind pressure without any failure),
including functional design of the aluminum sections for
fixing glazing panels of various thicknesses, aluminium
cleats, sleeves and splice plates etc. gaskets, screws,
toggles, nuts, bolts, clamps etc., structural and weather
silicone sealants, flashings, fire stop (barrier)-cumsmoke
seals, microwave cured EPDM gaskets for water
tightness, pressure equalisation and drainage and
protection against fire hazard including:

(B) Fabricating and supplying serrated M.S. hot dip


galvanised / Aluminium alloy of 6005 T5 brackets of
required sizes, sections and profiles etc. to
accommodate 3 Dimentional movement for achieving
perfect verticality and fixing structural glazing system
rigidly to the RCC/ masonry/structural steel framework of
building structure using stainless steel anchor fasteners/
bolts, nylon seperator to prevent bimetallic contacts with
nuts and washers etc. of stainless steel grade 316, of the
required capacity and in required numbers.

(C) Providing and filling, two part pump filled, structural


silicone sealant and one part weather silicone sealant
compatible with the structural silicone sealant of required
bite size in a clean and controlled factory / work shop
environment , including double sided spacer tape, setting
blocks and backer rod, all of approved grade, brand and
manufacture, as per the approved sealant design, within
and all around the perimeter for holding glass.

(D) Providing and fixing in position flashings of solid


aluminium sheet 1 rom thick and of sizes, shapes and
profiles, as required as per the site conditions, to seal the
gap between the building structure and all its interfaces
with curtain glazing to make it watertight.
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
(E) Making provision for drainage of moisture/ water that
enters the curtain glazing system to make it watertight,
by incorporating principles of pressure equalization,
providing suitable gutter profiles at bottom (if required),
making necessary holes of required sizes and of
required numbers etc. complete. This item includes cost
of all inputs of designing, labour for fabricating and
installation of aluminium grid, installation of glazed units,
TandP, scaffolding and other incidental charges
including wastages etc., enabling temporary structures
and services, cranes or cradles etc. as described above
and as specified.

2 8.7/113 Designing, fabricating, testing, installing and fixing in


position Curtain Wall with Aluminium Composite Panel
Cladding, with open grooves for linear as well as
curvilinear portions of the building , for all heights and all
levels etc. including:
a) Structural analysis and design and preparation of shop
drawings for pressure equalisation or rain screen
principle as required, proper drainage of water to make it
watertight including checking of all the structural and
functional design.
b) Providing, fabricating and supplying and fixing panels
of aluminium composite panel cladding in pan shape in
metalic colour of approved shades. The aluminium
composite panel cladding sheet shall be coil coated, with
Kynar 500 based PVDF / Lumiflon based fluoropolymer
resin coating of approved colour and shade on face # 1
and polymer (Service) coating on face # 2 as specified
using stainless steel screws, nuts, bolts, washers, cleats,
weather silicone sealant, backer rods etc.

c) The fastening brackets of Aluminium alloy 6005 T5 /


MS with Hot Dip Galvanised with serrations and serrated
washers to arrest the wind load movement, fasteners,
SS 316 Pins and anchor bolts of approved make in SS
316, Nylon separators to prevent bi-metallic contacts all
complete required to perform as per specification and
drawing The item includes cost ofall material and labour
component, the cost ofall mock ups at site, cost of all
samples of the individual components for testing in an
approved laboratory, field tests on the assembled
working curtain wall with aluminium composite panel
cladding, cleaning and protection of the curtain wall with
aluminium composite panel cladding till the handing over
ofthe building for occupation.
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
Base frame work for ACP cladding is payable under the
relevant aluminium items. The Contractor shall provide
curtain wall with aluminium composite panel cladding,
having all the performance characteristics all complete,
as per the Architectural drawings, as per item
description, as specified, as per the approved shop
drawings and as directed by the Engineer-in-Charge.
However, for the purpose of payment, only the actual
area on the external face of the curtain wall with
Aluminum Composite Panel Cladding (including width of
groove) shall be measured in sqm. up to two decimal
places.
8.7.3 3 mm thick alumminium composite panne1 material
consisting of 2.5 mm thick FR grade mineral core
SQM 400.00 3312.00
sandwiched between two alumminium sheets (each
0.25mm thick)

3 10.2/17 Structural steel work riveted, bolted or welded in built up


8 sections, trusses and framed work, including cutting,
hoisting, fixing in position and applying a priming coat
ofapproved steel primer all complete.
Steel work welded in built up sections / framed work
KG 26400.00 68.70
including cutting,
4 10.3/17 Providing and fixing in position collapsible steel shutters
8 with vertical channels 20xlOx2mm and braced with flat
non diagonals 20x5mm size with top and bottom rail of T-
iron 40x40x6mm with 40mm dia steel pulleys complete
with bolts, nuts, locking arrangement, stoppers,handles, SQM 20.00 4131.90
including applying a priming coat ofapproved steel
primer. Rate includes recess cutting in floor and making
good the same wherever required.

VII - WOODEN WORK-DOORS,


WINDOWS & VENTILATORS WITH GRILL &
FLYMESH PROVISION
1 9.18/13 Providing and fixing lSI marked flush door shutters
5 conforming to IS: 2202 (Part I) decorative type, core of
block board construction with frame of 1st class hard
wood and well matched teak 3 ply veneering with vertical
grains or cross bands and face veneers on both faces of
shutters of such as duro board, century or equivelant
make.
9.18.2 30 mm thick including ISI marked Stainless Steel butt
SQM 192.25 3660.00
hinges with necessary screws
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)

2 10.13/1 Providing and fixing pressed steel door frames


79 conforming to IS: 4351 manufactured from commercial
mild steel sheet including hinges, jamb, lock jamb, bead
and if required angle threshold of mild steel angle of
section 50x25mm, or base ties of 1.60 mm pressed mild
steel welded or rigidly fixed together by mechanical
means, including M.S. pressed butt hinges, 2.5mm thick
with mortar guards, lock strike-plate and shock absorbers
as specified filling the frame with Cement Concrete 1:3:6
at site before fixing (cost of concrete to be paid
separately) and applying a coat of approved steel primer
after pre-treatment ofthe surface as directed by Engineer-
in-charge:
10.13.2 Profile C of 1.60mm thick single rebate of size
100mmx5Omm
10.13.2. Fixing with adjustable lugs with split end tail to each
RM 90.70 431.40
1 jamb.

3 10.25/1 Providing and fixing stainless steel ( Grade 304) railing


82 made of Hollow tubes, channels, plates etc. including
welding, grinding, buffing, polishing and making
curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete ilc
fixing the railing with necessary accessories and
stainless steel dash fasteners , stainless steel bolts etc., KG 1124.00 793.79
ofrequired size, on the top ofthe floor or the side of waist
slab with suitable arrangement as per approval of
Engineer-in-charge. ( for payment purpose only weight of
stainless steel members shall be considered excluding
fixing accessories such as nuts, bolts, fasteners etc.)

4 9.79/14 Providing and fixing bright finished brass tower bolts


5 (barrel type) with necessary screws etc. complete:
9.79.1 250x10mm EACH 71.00 329.00
9.79.3 150x10mm EACH 60.00 221.00

5 9.80/14 Providing and fixing bright finished brass door latch with
5 necessary screws etc. complete :
9.80.1 300x16x5 mm EACH 100.00 237.00

6 9.81/14 Providing and fixing bright finished brass handles with


5 screws etc. complete :
9.81.1 125 mm EACH 71.00 205.00
9.81.2 100 mm EACH 50.00 181.00
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
7 21.1/36 Providing and fixing aluminium work for doors, windows,
2 ventilators and partitions with extruded built up standard
tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS:733 and
IS:1285, fixed with rawl plugs and screws or with fixing
clips, or with expansion hold fasteners including
necessary filling up of gaps at junctions, at top, bottom
and sides with required PVC/neoprene felt etc.
Aluminium sections shall be smooth, rust free, straight,
mitred and jointed mechanically wherever required
including cleat angle, Aluminium snap beading for
glazing / paneling, CP brass / stainless steel screws, all
complete as per architectural drawings and the directions
of Engineer-in-charge. (Glazing and paneling to be paid
for separately):

21.1.1 For fixed portion


21.1.1.1 Anodised aluminium (anodised transparent or dyed to
required shade according to IS:1868, minimum anodic KG 3913.31 353.00
coating of grade AC15)
8 21.1.2 For shutters of doors, windows & ventilators including
providing and fixing hinges/ pivots and making provision
for fixing of fittings wherever required including the cost
of PVC / neoprene gasket required (Fittings shall be paid
for separately).
21.1.2.1 Anodised aluminium (anodised transparent or dyed to
required shade according to IS:1868, minimum anodic KG 3913.31 400.00
coating of grade AC15)
9 21.3/36 Providing and fixing glazing in aluminium door, window,
3 ventilator shutters and partitions etc. with EPDM rubber/
neoprene gasket etc. complete as per the architectural
drawings and the directions of engineer-in-charge . (Cost
of aluminium snap beading shall be paid in basic item) :

21.3.2 With float glass panes of 5.50 mm thickness SQM 652.22 932.00

VIII - FLOORING
1 11.2/19 52 mm thick cement concrete flooring with concrete
6 hardener topping, under layer 40 mm thick cement
concrete 1:2:4 (1 cement: 2 sand : 4 graded stone
aggregate 20 mm nominal size) and top layer 12 mm
thick cement hardene consisting of mix 1:2 (1 cement
hardener mix : 2 graded stone aggregate 6 mm nominal SQM 540.00 399.00
size) by volume, hardening compound mixed @2 litre
per 50kg of cement or as per manufacturers
specifications. This includes cost of cement slurry, but
excluding the cost ofnosing of steps etc. complete.

2 11.34/2 Kota stone slab flooring over 20 mm (average) thick


03 base laid over and jointed with grey cement slurry mixed
with pigment to match the shade ofthe slab including
rubbing and polishing complete with base of cement
mortar 1 : 4 (1 cement: 4 sand) :
11.34.1 25 mm thick. SQM 217.24 1043.00
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
3 11.35/2 Kota stone slabs 25mm thick in risers of steps, skirting,
03 dado and pillars laid on 12mm (average) thick cement
mortar 1:3 (1 cement : 3 coarse sand) and jointed with
SQM 50.34 1012.00
grey cement slurry mixed with pigment to match the
shade of the slabs, including rubbing and polishing
complete.
4 11.43/2 Extra for pre fmished nosing in treads of steps of Kota
04 stone/ sand stone slab.
For Treads RM 241.50 39.00
5 44.44/2 Extra for Kota stone/ sand stone in treads of steps and
04 risers using single length upto 1.05 metre.
For Treads SQM 10.00 10.00
6 11.46/2 Providing and fixing Ceramic glazed wall tiles 300x450
04 mm or more (having thickness 6 to 7 mm) of 1st quality
conforming to IS : 15622 of approved make in all
Colours shades, Except burgundy, Bottle green, Black,
laid on 12mm thick bed of Cement Mortar 1:3 (1 Cement SQM 481.32 878.00
: 3 sand) jointed with grey cement slurry @3.3 kg per
sqm including pointing the joints with white cement and
matching pigments etc., complete.

7 11.49/2 Providing and laying rectified Glazed Ceramic floor tiles


05 300x300 mm or more (having thickness 9 to lOmm) of
1st quality conforming to IS : 15622 of approved make in
colours White, Ivory, Grey, Fume Red Brown, laid on SQM 343.05 961.00
20mm thick cement mortar 1:4 (1 Cement : 4 sand)
including grouting the joints with white cement and
matching pigments etc., complete.
8 11.53/2 Providing and laying vitrified floor tiles in different sizes
05 with water absorption's less than 0.08% and conforming
to IS : 15622 of approved make in all colours and
shades, laid on 20mm thick cement mortar 1:4 (1
cement : 4 sand) including grouting the joints with white
cement and matching pigments etc., complete.

11.53.2 Size of Tile 600x600x9-10 mm SQM 1597.84 894.00


9 8.2/78 Providing and fixing 16mm thick gang saw cut mirror
polished premoulded and prepolished) machine cut for
kitchen platforms, vanity counters, window sills, facias
and similar locations of required size of approved shade,
colour and texture laid over 20mm thick base cement
mortar 1:4 (1 cement : 4 coarse sand) with joints treated
with white cement, mixed with matching pigment, epoxy
touch ups, including rubbing, curing, moulding and
polishing to edge to give high gloss finish etc. complete
at all levels.
8.2.8 Granite of any colour and shade
8.2.8.2 Area of slab over 0.50 sqm. SQM 617.50 2544.00
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
10 11.27/2 Providing and laying machine cut, mirror polished Italian
01 Marble stone flooring, in required design (Simple
geometrical, abstract etc.) and in patterns in combination
with Italian marble stones of different colours, shades
and finished surface texture etc., in linear portions of the
building, all complete as per the architectural drawings,
with 18 mm thick stone slab laid over 20 mm (average)
thick base of cement mortar 1:4 (l cement : 4 sand) laid SQM 200.00 4915.00
and jointed with white cement slurry @ 4.4 kg/sqm
including pointing with white cement slurry admixed with
pigment to match the marble shade including rubbing,
curing and polishing etc. all complete as specified and as
directed by the Engineer-in-Charge. a) 18 mm thick
Italian Marble stone slab,Perlato, Rosso verona, Fire
Red or Dark Emperadore etc
11 11.32/2 Providing and laying flamed fmish Granite stone flooring
03 in required design and patterns, in linear as well as
curvilinear portions of the building all complete as per
the architectural drawings with 18 mm thick stone slab
over 20 mm (average) thick base of cement mortar 1:4
(1 cement: 4 sand) laid and jointed with cement slurry
and sqm 200.00 3663.00
pointing with white cement slurry admixed with pigment
of matching shade including rubbing , curing and
polishing etc. all complete as specified and as directed
by the Engineer-in-Charge :
a) Flamed finish granite stone slab Jet Black, Cherry
Red, Elite Brown, Cat Eye or equivalent.
12 11.60/2 Providing and laying Antiskid endura floor tiles of any
07 sizes, 12 mm thickness with water absorption's less than
0.08% and conforming to IS:15622 of approved make in
all colours and shades, laid on 0mm thick cement sqm 280.00 880.00
mortar 1:4 (1 cement :4 sand) including routing the
joints with white cement with matching pigments etc.,
complete.

IX - CEMENT PLASTER
1 13.1/24 12 mm cement plaster of mix:
4
13.1.2 1:6 (1 cement: 6 sand) SQM 13086.00 110.00
2 13.3/24 20 mm cement plaster of mix:
4
13.3.2 1:6 (1 cement: 6 sand) SQM 3358.68 156.00
3 13.15/2 Extra for plastering exterior walls of height more than 10
45 m from ground level for every additional height of 3 m or
part thereof.
Second Floor SQM 877.50 27.00
Terrace Floor SQM 153.60 54.00
4 13.8/24 6 mm cement plaster of mix:
4
13.8.1 1:3 (1 cement : 3 fine sand) SQM 3091.00 96.00
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
5 13.17/2 18 mm cement plaster in two coats under layer 12 mm
44 thick cement plaster 1:5 (1 cement: 5 coarse sand) and a
top layer 6mm thick cement plaster 1:3 (1 cement : 3 SQM 270.00 183.00
coarse sand) finished rough with sponge.

6 13.14/2 Extra for providing and mixing water proofing material in per bag
45 cement plaster work in proportion recommended by the of 50Kg
manufacturers. cement 335.87 79.00
used in
mix
7 13.27/2 Providing and fixing chicken mesh as per lSI
47 specification and in the required width with 50mm long
Bombay nails on vertical and horizontal junctions of
SQM 890.00 62.00
RCC and brick wall including scaffolding and all lead and
lift etc. complete before plastering upt 10 meter height.

8 13.28/2 12 mm thick plain cement mortar bands in cement


47 mortar 1:4 (1 cement: 4 fine sand)
13.28.2 Sunk Band RM 400.00 2.25

XI- PAINTING
1 13.47/2 Distempering with oil bound washable distemper of
49 approved brand and manufacture to give an even shade
13.47.1 New work (two or more coats) over and including priming
SQM 14126.92 60.00
coat with cement primer.
2 13.56/2 Finishing walls with Premium Acrylic Smooth exterior
50 paint with Silicone additives of required shade
13.59.1 New work (Two or more coats applied @ 1.43 ltr/ 10 sqm
over and including base coat of water proofing cement SQM 3358.68 84.00
paint applied @2.20 kg/10 sqm)

3 13.38/2 Providing and applying plaster of paris putty of 2 mm


48 thickness over plastered surface to prepare the surface SQM 4318.38 77.00
even and smooth complete
4 13.49/2 Wall painting with plastic emulsion paint of approved
49 brand and manufacture to give an even shade:
13.49.1 Two or more coats on new work SQM 4318.38 64.00
5 13.69/2 Painting with synthetic enamel paint of approved brand
52 and manufacture of required colour to give an even
shade:
13.69.1 Two or more coats on new work over an under coat of
suitable shade with ordinary paint of approved brand and SQM 1488.10 77.00
manufacture.
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
X- ROOF TREATMENT WORK
1 22.5/37 Providing and laying water proofing treatment in sunken
2 portion of WCs, bathroom etc., by applying cement
slurry mixed with waterproofing cement compound
consisting of applying :
(a) First layer of slurry of cement @ 0.488 kg/sqm mixed
with waterproofing cement compound @ 0.253 kg/sqm.
This layer will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm SQM 617.49 193.00
mixed with water proofing cement compound @ 0.126
kg/sqm. This layer will be allowed to air cure for 4 hours
followed with water curing for 48 hours. The rate includes
preparation of surface, treatment and sealing of all
joints, corners, junctions of pipes and masonry with
polymer mixed slurry.

2 22.7/37 Providing and laying integral cement based water


2 proofmg treatment including preparation of surface as
required for treatment of roofs, balconies, terraces etc
consisting of following operations: a) Applying a slurry
coat of neat cement using 2.75 kg/sqm. of cement
admixed with water proofing compound conforming to
IS. 2645 and approved by Engineer-in-charge over the
RCC slab including adjoining walls upto 300mm height
including cleaning the surface before treatment. b)
Laying brick bats with mortar using broken bricks/brick
bats 25 mm to 115mm size with 50% of cement mortar
1:5 (l cement: 5 sand) admixed with water proofmg
compound conforming to IS : 2645 and approved by
Engineer-in-charge over 20 mm thick layer of cement
mortar of mix 1:5 (1 cement :5 sand) admixed with water
proofmg compound conforming to IS : 2645 and
approved by Engineer-in-charge to required slope and
treating similarly the adjoining walls upto 300 mm height
including rounding of junctions of walls and slabs.

(c) After two days of proper curing applying a second


coat of cement slurry using 2.75kg/sqm of cement
admixed with waterproofing compound conforming to
IS:2645 and approved by Engineer-incharge.
(d) Finishing the surface with 20 mm thick jointless
cement mortar of mix 1:4 (1 cement :4 coarse sand)
admixed with water proofing compound conforming to
IS:2645 and approved by Engineer-in-charge including
laying glass fibre cloth of approved quality in top layer of
plaster and finally finishing the surface with trowel with
neat cement slurry and making pattern of 300x300 mm
square 3mm deep.
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
(e) The whole terrace so finished shall be flooded with
water for a minimum period of two weeks for curing and
for final test. All above operations to be done in order
and as directed and specified by the Engineer-in-Charge
: (with 5 years service guarantee)
22.7.1 With average thickness of 120mm and thickness at
SQM 857.00 885.00
khurra as 65 mm.mmimum

XI-WATER SUPPLY AND SANITARY WORKS


1 19.9/34 Constructing brick masonry manhole in cement mortar
2 1:4 ( 1 cement: 4 sand) RC.C. top slab with Cement
Concrete 1:2:4 mix (1 cement: 2 sand : 4 graded stone
aggregate 20 mm nominal size), foundation concrete
1:4:8 mix (1 cement: 4 sand: 8 graded stone aggregate
40mm nominal size) inside plastering 12mm thick with
cement mortar 1:3 (1 cement: 3 sand) fmished with
floating coat of neat cement and making channels in
cement concrete 1:2:4 (1 cement : 2 sand : 4 graded
stone aggregate 20mm nominal size) finished with a
floating coat of neat cement complete as per standard
design :
19.9.1 Inside size 90x80 cm and 45 cm deep including CI cover
with frame (light duty) 455x610 mm internal dimensions
total weight of cover and frame to be not less than 38 kg
(weight of cover 23 kg and weight of frame 15 kg):

19.9.1.1 With well burnt bricks


EACH 16.00 7997.00
2 19.10/3 Extra for depth for manholes
43
19.10.1 Size 90x80 cm
19.10.1. With well burnt bricks
RM 12.00 6176.00
1
19.10.2 Size 120x90 em
19.10.2. With well burnt bricks
RM 12.00 7380.00
1
3 19.7/34 Providing and fixing square-mouth S.W. gully trap class
1 SP1 complete with C.1. grating brick masonry chamber
with water tight C.1. cover with frame of 300 x300 mm
size (inside) the weight of cover to be not less than 4.50
kg and frame to be not less than 2.70 kg as per standard
design :
19.7.2 150x100 mm size, P type.
19.7.2.1 With well burnt bricks
EACH 32.00 1803.00
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
4 25.2/24 Providing and fixing white vitreous china pedestal type
5 water closet (European type WC pan) with seat and lid,
10 litre low level white PVC flushing cistern with
manually controlled device (handle lever), conforming to
IS:7231, with all fittings and fixtures complete including
cutting and making good the walls and floors wherever
required :
25.2.1 W.C. pan with ISI marked white solid plastic seat and lid
EACH 45.00 2525.00
5 17.6/29 Providing and fixing white vitreous china flat back or wall
1 corner type lipped front urinal basin of 430x260x350
mm and 340x410x265 mm sizes respectively with
automatic flushing cistern with standard flush pipe and
CP brass spreaders with brass unions and GI clamps
complete, including painting of fittings and brackets,
cutting and making good the walls and floors wherever
required:
17.6.2 Range of two urinal basins with 5 litre white PVC
EACH 20.00 4458.00
automatic flushing cistern.
17.6.3 Range of three urinal basins with 10 litre white PVC
EACH 10.00 6312.00
automatic flushing cistern.
6 17.11/2 Providing and fixing wash basin with CI brackets, 15
92 mm CP brass pillar taps, 32 mm CP brass waste of
standard pattern, including painting of fittings and
brackets, cutting and making good the walls wherever
require :
17.11.1 White Vitreous China Wash basin size 630x450 mm with
EACH 1.00 2460.00
a single 15 mm CP brass pillar tap.
17.11.4 White Vitreous China Flat back wash basin size 550x400
EACH 2.00 1664.00
mm with single 15 mm CP brass pillar tap.
17.11.7 White Vitreous China Flat back wash basin size 450x300
EACH 48.00 1525.00
mm with single 15 mm CP brass pillar tap.

7 17.57/3 Providing and fixing trap self cleansing design with


00 screwed down or hinged grating with or without vent arm
complete, including cost of cutting and making good the
walls and floors:
17.57.2 100 mm inlet and 75 mm outlet
17.57.2.
Sand Cast Iron S&S as per IS- 1729 EACH 90.00 540.00
2
8 17.68/3 Providing and fixing mirror of superior glass (of
03 approved quality) and of required shape and size with
plastic moulded frame of approved make and shade with
6 mm thick hard board backing:
17.68.3 Oval shape 450x350mm (outer dimensions) EACH 4.00 697.00
17.68.4 Rectangular shape 1500x450 mm EACH 26.00 1311.00
9 17.70/3 Providing and fixing toilet paper holder :
03
17.70.2 Vitreous China EACH 56.00 324.00
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)

WATER SUPPLY WORKS


10 18.10/3 Providing and fixing G.I. pipes complete with G.I. fittings
17 and clamps, including cutting and making good the walls
etc. Internal work - Exposed on wall
18.10.1 15 mm dia RM 400.00 211.00
18.10.3 25 mm dia RM 600.00 300.00
18.10.5 40 mm dia RM 400.00 479.00
18.10.6 50 mm dia RM 250.00 596.00
11 18.50/3 Providing and fixing brass bib cock of approved quality :
30
18.50.1 15mm nominal bore EACH 50.00 306.00
12 18.32/3 Providing and fixing gun metal gate valve with CI wheel
25 of approved quality (screwed end):
18.32.1 25 mm nominal bore EACH 20.00 486.00
18.32.3 40 mm nominal bore EACH 8.00 677.00
13 17.58/3 Providing and fixing unplasticised Rigid PVC soil and
01 waste pipes conforming to IS: 13592 Type B including
jointing with seal ring conforming to IS : 5382 leaving 10
mm gap for thermal expansion. Single socketed pipes
for working pressure of 4 kg/sqcm.
17.58.1 75 mm diameter (minimum wall thickness 3.2mm) RM 320.00 136.00
17.58.2 110mm diameter (minimum wall thickness 3.2mm) RM 280.00 238.00
19.4/34 Providing and laying below ground unplasticised PVC
0 pipe to with stand working pressure of 4 kg/cm2 soild
waste pipes confirming to IS:13592 and IS:4985
including jointing with seal ring confirming to IS :5282
leaving 10mm gap for thermal expansion all necessary
fittings etc. complete. Excavation to be paid seperataly.

19.4.2 160mm diameter OD RM 180.00 477.00


14 17.59/3 Providing and fixing unplasticised PVC moulded
01 fittings/accessories for unplasticised Rigid PVC soil and
waste pipes conforming to IS: 13592 Type A including
jointing with seal ring conforming to IS: 5382 leaving
10mm gap for thermal expansion.
17.59.5 Bend 87.50
17.59.5. 75 mm bend
EACH 40.00 117.00
1
17.59.5. 110mm bend
EACH 40.00 172.00
2
17.59.3 Single tee with door
17.59.3. 75x75x75 mm
EACH 40.00 219.00
1
17.59.3. 110x110x110 mm
EACH 40.00 346.00
2
17.59.1 Coupler
17.59.1. 75mm
EACH 40.00 117.00
1
17.59.1. 110mm
EACH 40.00 154.00
2
SOR RATE (IN
S.No. DESCRIPTION OF ITEM UNIT QTY.
NO. RS.)
15 18.49/3 Providing and placing on terrace (at all floor levels)
30 polyethylene water storage tank lSI: 12701 marked with
cover and suitable litre locking arrangement and making
LTR. 50000.00 7.00
necessary holes for inlet, outlet and overflow pipes but
without fittings and the base support for tank

16 12.15 Providing and fixing precoated galvanised iron profile


sheets (size, shape and pitch of corrugation as
approved by Engineer-in-charge) 0.50 mm + 0.05 %,
total coated thickness with zinc coating 120 gsm as per
IS: 277 in 240 mpa steel grade, 5-7 microns epoxy
primer on both side of the sheet and polyester top coat
15-18 microns. Sheet should have protective guard film
of 25 microns minimum to avoid scratches while SQM 1800.00 652.00
transportation and should be supplied in single length
upto 12 metre or as desired by Engineer-in-charge. The
sheet shall be fixed using self drilling /self tapping
screws of size (5.5x 55mm) with EPDM seal, complete
upto any pitch in horizontal! vertical or curved surfaces
excluding the cost ofpurlins, rafters and trusses and
including cutting to size and shape wherever required

XII-NON-SOR ITEMS
1 MR Supply, Installation, Testing and Commissioning of
Passenger Elevator of make good quality brand
should be approved by Engineer Incharge and Architect
of capacity 10 Passengers / 680 Kg, speed 1m/sec,
Variable Voltage Variable Frequency Drive,
Microprocessor based Closed Loop Simplex Collevtive
Selective Control Operation, serving Ground + 2 Upper
Floors with travel of 12.0 m, 3 Stops / 3 Openings / 3
Landings, entrance positions all on the same side, with each 2.00 1200000
Machine Room, car enclosure to be Stainless Steel
Hairline finish panels, Emergency Light and Alarm, Fan,
Emergency Stop Button, Landing Door should be
Automatic Center Opening SS Hairline doors, with
indicators and controls in car and landing,& including all
respect electrical work in a building complete in all
respects and should be as per IS / NBC specification.