Professional Documents
Culture Documents
InterpretationDetail BC05-025
InterpretationDetail BC05-025
TrackingNumber=4863
Interpretation Detail
Standard Designation: BPV Section IX
Edition/Addenda:
Para./Fig./Table No:
Subject Description: QW-200.4(b), Combining Procedure Qualification Records
Date Issued: 03/08/2005
Record Number: BC05-025
Interpretation Number : IX-04-18
Question(s) and Reply(ies):
Background: A combination GTAW and SMAW WPS is
supported by two PQRs. PQR A is welded with SMAW to
join 1-1/2 in. (38 mm) thick plates with 1-1/2 in. (38 mm) of
SMAW deposit. PQR B is welded with GTAW and SMAW to
join 1/2 in. (13 mm) thick plates, with 1/8 in. (3 mm) of
GTAW deposit, and 3/8 in. (10 mm) of SMAW deposit.
Question (3): When impact tests are performed for both PQRs
with acceptable results, do PQRs A and B qualify the
combination WPS for a base metal thickness range of 1/2 in.
(13 mm) to 8 in. (200 mm) when impact testing is required?
Copyright © 2023 by the American Society of Mechanical Engineers. No reproduction may be made of this material without written
consent of ASME
https://cstools.asme.org/Interpretation/InterpretationDetail.cfm?TrackingNumber=4863 1/1