Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Clear Print Submit

Hydro
Hydro re
Passenger
Quote Request Form
th
19336 607 Ave
Mankato MN 56001 Today's Date:
Ph (507) 245-3060 Fax: (507) 245-4198
An EOE/AA Employer Quote Due Date:

Customer: Job Name:


Contact: Job Location:
Address:
JACK TYPE
Phone: Fax: Borehole Single Stage
New Construction Email Holeless Multi Stage
Existing Roped Hydro Twin Jack
Capacity:
Class of Loading: Landings: Hoistway Width: Overhead:
Gross Weight: Front Openings: Hoistway Depth: Pit Depth:
Travel: Rear Openings: Platform Width: Voltage:
Speed: Side Openings: Platform Depth: Phase:

Electrical Rating: Hoistway: * NEMA 1 NEMA: Code: ASME A17.1 yr


Machine Room: * NEMA 1 NEMA: IBC
* Indicates MEI standard materials Other Codes

HOISTWAY MODULE
INCLUDE THIS SECTION IN QUOTE
Platform Subfloor Material:
Platform Finish Floor Thickness weight sq. ft. (F/F by others) * 1 layer 3/4" plywood
Other
Sling, Spring Buffers, Painted Black Others
Rail Guides: * Slide Roller Swivel Seismic Zone (2,3,4)
Limit Switch Package/Car Top Station Government Submittal Package
Maintenance Manuals Certified Engineer Stamp on Drawings
Other Under Car Light with Outlet
Platform Isolation Full Partial

JACK MODULE
INCLUDE THIS SECTION IN QUOTE
Maximum Jack length
Maximum Jack section length
Maximum Pressure Allowed * Factory Tape Wrap (Inground Cars only)
PVC Casing Sch 40 Sch 80 Other:

POWER UNIT MODULE


INCLUDE THIS SECTION IN QUOTE Additional Options
* Submersible * 80 Starts /hr Pre-mount Controller Oil Level Sensor
Dry 120 Starts /hr Oil Viscosity Switch Low Pressure Switch
Machine Room: Oil Level Sight Gauge Load Weighing Switch
* Adjacent @ Lowest Level Tank Heater Oil Cooler - MEI
Adjacent feet above lowest level Oil Return Pump Oil Return Pump w/Copper Tube
Remote feet from hoistway Other
Shared Machine Room
PIPING MODULE
INCLUDE THIS SECTION IN QUOTE
* MEI Standard Package Isolation Couplings Mainline Strainer Other
Includes Pipe, Pipe Stands,
Shutoffs, and Fittings Overspeed Valve Seamless Pipe Sch 80 Pipe
Threaded Pipe Grooved Pipe

CONTROLLER MODULE
INCLUDE THIS SECTION IN QUOTE
Manufacturer: * Vertitron Midwest, Inc (VMI) Elevator Control Corp Other:
Operation: Selective Collective MCE
* Simplex Duplex Group
Starter: * Wye Delta Across the Line Electronic Soft Start
Features: * Phase I & II Fire Service Oil Viscosity Hospital Service
* Independent Service EMT-Code Blue Nudging
* Low Oil Circuitry *On-Board Diagnostics Homing
* Reverse Phase Detector Attendant Operation Battery Lowering
* Tape Selector Inconspicuous Riser Lobby Panel Interface
Load Weighing Hall Call Bypass Load Weighing Overload Emer. Generator Interface
Monitor System Interface Other:

ENTRANCE MODULE
INCLUDE THIS SECTION IN QUOTE
Hoistway Wall Thickness: “ Block Drywall
Jamb Construction: * Bolted Welded / Mitered Other:
Jamb Finish: * Enamel / Primed Stainless Steel Bronze #4 #8
Door Finish: * Enamel / Primed Stainless Steel Bronze #4 #8
Sills: *Aluminum Nickel-Silver Bronze Stainless Steel
Groutless Sill
Miscellaneous: Sound-Deaden Doors Sound-Deaden Frames Weather-Stripping
Others

DOOR EQUIPMENT MODULE


INCLUDE THIS SECTION IN QUOTE
*GAL (MOVFR) GAL (MOD) GAL (MOVFR W-Weather Resistant)
Other:

DOOR PROTECTION MODULE


INCLUDE THIS SECTION IN QUOTE
*Adams “Gatekeeper” Janus Panaforty Plus 3-D Protection Tri-Tronic (Nema 4)
Others:

WIRING MODULE
INCLUDE THIS SECTION IN QUOTE
* MEI Standard Package w/3 Pair Shielded Cable
Additional Pair Shielded Quantity:
Coaxial Cable Quantity:
Other :
CAB MODULE
Overall Size Handrails
Platform Width: X Depth: Location: Rear Wall Side Walls
Finished Floor Material/Thickness: Type: Round Flat Wood
Cab Height: Returned Ends: Yes No (for round or flat)
Handrail Size: (see table below)
Wall Configurations Material:
(brushed stainless or bronze for round or flat, maple or oak for wood)
Service Cab (Steel Shell) Round Sizes 1-½” or 2” diameter
Painted: Flat Sizes (Hollow) ½” x 1-½”
(choose from our standard paint colors or choose your own)
Metal: Flat Sizes (Solid) ½” x 1-½” | ⅜” x 2”, 3”, 4”, 6” | ¼” x 4”, 6”
(brushed, polished, or patterned stainless; brushed bronze)
Wood Sizes 1-½” x 5-½”, 7-½”, 9-½”, 11-½”
Plastic Laminate
Laminate: Bumpers
(choose from our plastic laminate chart) Flat With Returned Ends Straight Ends
Wood
Removable/Applied Panels Bumper Size: (see table below)

Removable Panel Applied Panel Material:


(brushed stainless for flat, maple or oak for wood)
Panel Finish: Number of Bumper Rows:
(choose from our laminate chart or metal finishes)
Reveal/Frieze/Base: Flat Sizes (Solid) ⅜” x 8”, ¼” x 8”
(paint or metal finish, same options as steel shell service cab)
Wood Sizes 1-½” x 5-½”, 7-½”, 9-½”, 11-½”
Glass Wall (s) (add to one of the cabs above)
Rear 1 Side 2 Sides Front Ceiling/Lighting
Frame Finish: (brushed stainless, aluminum) Aluminum Frame Ceiling
w/Lexan Diffusers w/Eggcrate Diffusers
Door Configuration Fluorescent Lights LED Lights
Front Only Front & Rear Front & Side
Single-Speed Two-Speed Downlight Island Ceiling
Opening: Right-Hand Left-Hand Center Finish:
(painted; plastic laminate; brushed or polished stainless; brushed bronze)
Door Opening Width: X Height: High Voltage Incandescent Lights
Door Finish: Low Voltage Halogen Lights
(painted; plastic laminate; brushed, polished, or patterned stainless; brushed bronze)
Transom, Return, & Jamb Finish: Perimeter Lighting
(painted; brushed, polished, or patterned stainless; brushed bronze)

Cove/Trough Lighting
COP Location: Return Side Wall Fluorescent Lights Recessed in Canopy
High Voltage Lights Recessed in Canopy
Low Voltage Lights Recessed in Canopy

Sill
Aluminum Nickel Silver
Bronze Stainless Steel
FIXTURE MODULE
INCLUDE THIS SECTION IN QUOTE
Type: * MEI Tilt Panel *Stationary (Applied) Panel Full Swing
Style: * Square Buttons Round Buttons Vandal-Resistant Buttons
Finish: * Stainless Steel Bronze * #4 #8
Features: * Car Position Indicator
Hall Position Indicator(s): Qty:
* Car Lantern(s) Hall Lanterns Certificate Frame
* Hall Stations EMT Service – Code Blue Hospital Service
*ADA Hands-Free Phone Service Cabinet Photo-Eye Keyswitch
* Top Access Keyswitch Independent Service Keyswitch * Bottom Access Keyswitch
Emergency Light Test Button 120 VAC Outlet * Inspection Keyswitch
Card-Reader Cut-Out Fireman's Phone Jack * Light Keyswitch
* Fan Keyswitch Special Engraving:
Auxiliary Car Operating Panel *NEMA 1 (or other NEMA Ratings)
Other:

RAIL MODULE
INCLUDE THIS SECTION IN QUOTE
T-Shaped Rails are Provided

ELEVATOR DATA
Enter Floor Markings & Travel
for Each Floor Served
Overhead
 12 12

11 11

Cab inside Clear 10 10


_______W X _______D
9 9

Platform 8 8

Hoistway 7 7

 6 6

Door= 5 5
 
Platform=  4 4
 Hoistway= 
3 3

2 2

1 1
Arch. Prints Available? Yes No Pit Depth
Shared Hoistway Yes No Front Rear

You might also like