Professional Documents
Culture Documents
Retardation Test
Retardation Test
𝑊𝑚𝑎𝑥
Half load = = 7 kg
2
𝑊𝑚𝑎𝑥
Load Torque TL= × 𝑅𝑒 = 7 × 0.165 = 1.155 𝑁𝑚
2
1600
1400
1200
Speed (rpm)
1000
800
600
400
200
0
0 1 1.27 1.92 2 2.97 3 4 4.25 5 6
Retardation Time (sec)
2 𝜋 𝑁 𝑇𝐹 2×𝜋×200×3.11
Frictional Power FP = = = 65.13 𝑘𝑊
60 60
2 𝜋 𝑁 𝑇𝐿 2×𝜋×1500×1.155
Brake Power BP = = = 181.42 𝑘𝑊
60 60
𝐵𝑃 𝐵𝑃 181.42
Mechanical Efficiency = × 100 = 𝐵𝑃+𝐹𝑃 × 100 = 181.42+65.13 × 100 = 73.58 %
𝐼𝑃