Download as pdf
Download as pdf
You are on page 1of 64
Downhole Measuring systems aa ee eee ao Ue ee ely www.triolcorp.us Contents PN eR ee CLD CE eee Cm RCO ro Nore Neue) Rene Coens Triol TMO1 Surface Unit aOR} aOR NYE) SRNL) SRN) RILEY} aOR Triol TM01-11 SRNL) Appendix (Additional Options) ate} B 13 a} 25 31 37 49 cy 61 Advantages of the Triol Downhole Measuring System TMO1 Performance Benefits, Cost Savings The Triol Downhole Measuring System TMO1 is engineered to provide years of reliable, efficient operating service at fluid temperatures up to #125°C (+257°F), #150°C (+302°F), or +175°C (+347°F), according to the model type. Different enclosure types for the Triol TMO1 are available, based on surface equipment configurations: the IP20 enclosure is designed for integration into a control cabinet, while the IP56 enclosure is designed as a self-contained equipment unit with included display and communication channels. A variety of submersible part designs are available, depending on operating conditions and fluid characteristics. Versatile design allows your equipment investment to precisely match your performance needs, for superb value. Several transmission modes are available for communication from within wells, including Ethernet and RS482/232 communication channel, which allows more efficient and cost-effective data collecting and processing. The lower submersible unit has a suspension weight of 500 kg; additional equipment can be added easily, without requiring additional mounting accessories. The Triol TMO1 is suitable for use with low-frequency motors (from 5Hz) and in systems with low-speed motors, including PMMs. The Triol TM01 is designed to resist electrical variances up to 1000 V, which allows safe operation with surface or submersible equipment that has temporary or permanent power circuit defects. External choke configuration guarantees that surface equipment is connected to the power cable and provides a stable connection with the submersible unit, even in instances of no zero point in the step-up surface transformer. The choke is easily integrated into the transformer case, or located adjacent to the transformer within a highly protected IP56 enclosure design. ‘A wide range of flanges supports compatibility with a diverse array of industry motor types. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 Sustainable cost savings during commissioning and well operations High submersible element reliability is due to the advanced design of innovative temperature-resistant components. Iterative testing during production and long-term testing at final inspection supports individual component longevity and extended service life of the system. Increased system reliability is due to rugged submersible unit design, suitable for high-tonnage and adverse conditions. High level of customer support via comprehensive operational documentation, precision-engineered installation kits for wells, and online service support. Enjoy rapid, error-free setup, connection, and operations. Specially designed testing equipment (test units) allows comprehensive performance validation during equipment descent into the well. Increase production with high quality, innovative solutions Accurate pressure measurement at pump intake from 0.05 MPa (5.8 psi) minimizes fluid column pressure accumulation above the pump and maximizes well production. Pressure measurement at pump discharge from 0.05 MPa (5.8 psi) and temperature measurement with a tolerance of +1°C allows optimization of surface equipment operating frequency and motor performance, which supports maximal well production. High speed data exchange between submersible and surface units is accomplished via a stable communication channel that ensures the constant availability of accurate, on-time data for making optimal decisions to maximize well production. User-friendly display interface on the IP56 surface unit allows field personnel to quickly make operational decisions and efficiently manage settings, for best-in-class safety performance that minimizes downtime. Simplified monitoring via a builtin modem allows efficient management and remote operation. Data received through the modem can be stored for predictive analysis, or sent to operators to manage additional diagnostic evaluation DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 Increased service life urate measurement of operating temperature and motor performance, with a tolerance of +1°C, provides superior component protection against overheating and temperature variance, for extended pump and motor service life it of vibration on three axes prevents destructive vibration that can adversely affect components, for extended system service life \ccurate measurement of insulation performance of the transformer, cable and pump components, ranging from 10 to 10,000 kOhm, allows efficient evaluation of insulation performance, for extended component service life.for as long as possible. tures Continuous, long-term, accurate, a high-speed insulation measurement within the submersible component guarantees operating personnel have the data needed for optimal safety of workers, system, and the well itself. aise) ieee Downhole Measuring System Lines Description ee Material SoS CRS nae ean eae Rec n ate) Max Working Pressure cet) Seer) her RELL) Length Pela Outside Diameter ea DTN Can CUS Nee =) ea emo 5 Primary Parameters for essential pump and well surveillance and protection Ekle ak ded Cod 1 30 | 20 | 50 | 30 | 30 | 35 | 100 | 20 er eee ery a Pere tr Coan De re Pump Discharge Pressure | psvMpa | 5.200/040 | ox/o001 | + 3 |[o roa) a ro olf olfelfe]folo]o Ir coors cf Ped oy ered ca erry BCU °F es ea 7 7 M rea) cy | 1502757 , coat Ss gogay | 0010 rare OU of tobe Ta . . a . une a Carre Beeiig. Re aac 5 ‘To 12 Month Totally u Kd ac a WO 5 Motor Ol/ Motor Winding | °c/ | 0-2007250/ ollolclclolcl. ig SCC uie a Ee a eee rear C0 CY OOOO Eee as | a5 [as | as ]as|as| 5 | as eee ad ia fine farse|a6|aa|za6| 236 [206 Pressure Accuracy 7 Era aE ca eo ea ee Pe 00s | 005 | 02] 02 | o2| 02 | 02 | oz meray a (0.08/] 0097 016i) 018/]0.18/|o18/| 0187 [o8/ mis o9 | 09 | 15] 15] 15] 15] 15 | 15 es sy 0 fa Ite lle le le l= zi Insulation Resistance Po CET 5 = ]-o I> =] cll eect a 70 Fee Pee ce eee Seer) =]>> = in Be Be cet 5 Parameter included as standard Triol Surface Board TMO1 P20 without Grice display (Triol Surface Card TMO1 IP20 with | UMKA-04, RS-232, RS-485 Modbus RTU display) Pea m MOSER ea) Cena em ea ray Cheer ee outputs / 8 inputs; Adam TMO1 adapter with CRC ec ee RU ee CR ESV PevaC haus Filed Applications for Tiol TMOL Priority date 12/29/2017 Downhole measuring system for a submersible pump Priority date 04/13/2018 Downhole measuring device for a submersible pump Priority date 05/22/2018 Well measuring device associated with a shaft Priority date 10/29/2018 Method of cooling a downhole measuring device Priority date 11/08/2018 Method of obtaining measured data and a system for implementation Priority date 03/21/2019 Telemetry system and method for cooling downhole electronics Standards ISO 9001:2015 Quality Management Systems - Requirements 2014/35/EU Low-Voltage Directive 2014/30/EU Electromagnetic Compatibility Directive DTN Can CUS Nee =) ea em TRIOL HIGH-VOLTAGE CHOKE The Triol High-Voltage Choke is an innovative component of the Triol Downhole Measuring System TMO1. It provides a reliable, high-performing communication channel between the Triol ‘TMO1's surface systems and submersible units. Triol High-Voltage Choke creates an artificial Wye point in step-up transformer configurations, where output windings are connected in a triangle circuit, thus ensuring a guaranteed connection between surface and submersible units. The inductor provides stable communication between surface and submersible units, and filters out PWM modulation peaks in Variable Speed Drives (VSDs).. Triol High-Voltage Choke includes fuses installed in each phase, to protect surface equipment components from accidents caused by phase imbalance in the submersible equipment's power supply circuit. Triol High-Voltage Choke can be installed within a step-up transformer case, or adjacent to the transformer or VSD within the IP56 enclosure. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 8 TUR Oe Cur ce Ts ‘Maximum voltage of power circuits 5000 V High voltage-saturation current, not less 270 mA Phase inductance 140 H Ambient temperature from -40°C(-40°F) to +60°C(140°F) Altitude, not more than 1000 m Enclosure 1P20/ 1P56 Duration mode Extended Number of safety interlocks 3 Maximum choke power circuit current 160 ma Overall dimensions 230 (9,05) x 460 (18,11) x 505 (19,88), mm (in) Weight, not more than 35 kg (77.1 Ibs) CE Certificate + DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 9 TRIOL Test UNIT The Triol Diagnostic Test Unit is an essential component of the Triol TMO1 system, intended for use across its entire service life. The test unit combines a wide range of functionality with mobile design, simple controls, and high reliability in challenging environments. Triol Diagnostic Test Unit supports rapid, efficient and successful installation of the Downhole Measuring System submersible unit and its introduction into the well. It provides an elevated level of safety performance, as well as trouble-free operation during pulling, operations, and installation processes. Triol Diagnostic Test Unit allows comprehensive analysis and monitoring of both submersible and surface Triol TM01 units, before and during operation. Triol Diagnostic Test Unit can be used as a replacement for the surface unit during emergencies or instances of equipment malfunction, ensuring efficient operations. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 10 Diagnostic Test Unit implements features ideal for use in petroleum industry operations around the world, including: Compact, highly mobile design is light enough to be carried with one hand. Rugged design, with included Peli 1520 case enclosure, |P67 protective enclosure during transportation, and IP33 protective enclosure during operation; these provide high insulation and damage resistance within normal operating conditions, as well as in conditions of increased operating temperature (+75°C) and high relative humidity (98%). Convenient operation due to simple controls, including display screen and external indicators for reading and managing data Long-lasting battery provides operational power for 4+ hours in continuous measurement mode, without an additional power source. Safe, reliable storage of up to 870,000 data records. Test Unit power supply 220 V £20% / 110 V 410% Rated frequency 50/60 Hz + 2% Power consumption, not more than 52W Battery mode, not less than 4h Ambient temperature = 20°C ... 485°C (-4 °F... #131 °F) Relative humidity +25°C, without condensation 100% Enclosure IP67 /1P33 Altitude, not more than 1000 m Interface RS-485, RS-232 Overall dimensions 492 x 189 x 418 mm Weight, not more than kg DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 "1 TrRIoL TMO1L Surrace UNIT Puce Rated voltage 220 v (#20 %), 110 v (+ 10%) Frequency 50/60 Hz (+2 %) Power consumption, not more than 1P20 - 40 W\ IPS6 - 300 W ‘Ambient temperature -40°C ... +75 °C (-40 °F ... +167 °F) Relative humidity under #25°C, without condensation 100% Communication eireult operating voltage 100 v Attitude, not more than 1000 m Enclosure, not less than Extended Weight 1P20, not more than 5 kg Overall dimensions P56, not more than “450 mm x 475 mm x 225 mm Weight IP56, not more than 30 kg Surface unit display UMKA-04 (Din-4, Dout-6, Ain-16, Aout-0) CE certification 1P20 CE certification IP56 bid DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 bin 12 DOWNHOLE MEASURING SYSTEM Uieoy TMB) eres) Trio! Downhole Measuring System TMO1-25 is a unique, high quality, superbly accurate and reliable solution for applications where there is a need to accurately monitor pressure and temperature at a pump discharge. This system can efficiently collect, process, display and transfer submersible unit data and well data, at fluid temperature up to 150°C (302"F), fluid temperature ‘at pump discharge up to 250°C (428°F), and equipment suspension zone pressure up to 40 MPa (5800psi).. ETT U aru Rr Rl aii Bola) - Pump discharge pressure - Reservoir fluid pressure es - Pump discharge temperature - Submersible motor lubricant temperature, motor temperature, or stator winding value A - Well fluid temperature = Motor vibration in X, Y and Z axis - Insulation resistance in the triangle 1 ae Ls circuit (transformer-cable-motor) ‘TMO1- 25 Surface Board + Can be installed into VSD for communicating data with IP20 enclosure. TMO01- 25 Surface Panel + Can be installed remotely from VSD, in a protected case within IP56 enclosure and with UMKA-04 controller to display data via monitor and indicator lights DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 14 Communication of submersible units is accomplished via two channels, engineered with stainless steel tubes. The first is filled with formation fluid, to control pump discharge pressure; the second contains a conductor with a temperature sensor inside. Electronics for processing pressure and temperature data are located in the lower submersible unit. Options available (ordered separately) * Digital and Analog I/O Module TM01 + Supports, adapters, and flanges for connecting submersible units to various size motors and ESPs + Exterior Trio! High-Voltage Choke to create an artificial Wye point in step-up transformers + Triol Diagnostic Test Unit TM01, for controlling and monitoring operability of the TMO1-25 system and control equipment during its assembly, installation and operation + SCP Modem for wireless transfer of collected data Triol High-Voltage Choke can be configured in two different enclosures: + 1P20 (for installation into the power transformer) + IP56 (for installation near the power transformer, in a separate case) Tri TM01-25 consists of three block: + Surface unit located inside the VSD, or separately in a protected case + Submersible unit attached to motor bottom + Submersible unit located between the pump and tubing DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 15 TMO01-25 Specifications Perec Ambient temperature Motor oil temperature / Motor stator winding Pump intake pressure Pump discharge pressure Pump discharge temperature Axis vibration x y, z Insulation resistance “Step-up transformer ~ motor power line’ / Current leakage Insulation resistance “Step-up transformer ~ motor ower line” Operation mode (duration) Data update time Controller communication protocol Communication protocol Step-up transformer /Submersible unit Communication protocol Surface unit /VSD up to +150 °C (82-302°F) constantly, resolution 001°C (01°F) From 0 to 200/250 °C (32-392/482°F) #1°C (#1,8°F),, resolution 0,01°C (0,1°F) 0-40 MPa (0-5800 psi) +0,05 MPa (#6 psi), resolution 0,001 MPa (0,1 psi) 0-40 MPa (0-5800 psi) +0,05 MPa (+6 psi), resolution 0,001 MPa (0,1 psi) 0-250 °C #1°C (82-428°F #1,8°F), resolution 0,01°C (oF) 0-30 m/s? (0-3,06 g) #5 %, resolution 0,1 m/s* (0.001 9) 0-100 ka (+5 %) resolution 1 kO / 0-10 mA 45%, (0,001 mA) 1000-10000 ka (#10 %) resolution 1 kO extended 308 RS-232, RS-485 Modbus RTU Closed Triol /Transfer Aree auc Maximum operation pressure in submersible in suspension units zone Maximum operation temperature of the bottom submersible unit Maximum operation temperature of the top submersible unit Bottom submersible unit length (unsupported) Top submersible unit length, not more than Bottom submersible unit outside diameter, not more than ‘Top submersible unit outside diameter, not more than Bottom submersible unit weight, not more than Top submersible unit weight, not more than ‘Submersible unit material ‘Submersible unit end details material DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 2 40 MPa (5800 psi) #0,5 % 150°C (302°F) 250 °C (428°F) 745 mm, 250 mm, 103 mm, 110 mm. 22kg 8kg Stee! 12X18 Steel 40x13, 16 Rated voltage Seamless stainless steel tube 316L with fittings Seamless stainless steel tube 316L with fittings and temperature sensor Carbon steel coating TC-1/4 in-316L (50m) TC-1/4 in-316L (50m)+ thermal couple Pt1000 Arad Submersible unit coating Frequency Power consumption, not more than Ambient temperature Ambient temperature Surface Card Relative humidity under +25°C, without condensation Operating voltage in the communication circuit with a submersible unit (if the insulation of Step-up ~ motor cable (system is in operation condition) Attitude, not more than Enclosure, not less than Duration mode Overall dimensions IP20, not more than Weight IP20, not more than Overall dimensions IPS6, not more than Weight IP56, not more than Overall dimensions Surface Card 1P20, not more than Weight Surface Card 1P20, not more than Surface Panel display 220 V (420 %), 110 V (#10 %) 50/60 Hz (+ 2%) 1P20-40 W IP56-300 W from -40 °C to +75 °C (-40°F +167°F) from -20 °C to +80 °C (4°F +176°F) 100% 100 1000 m 1P20 / P56 Extended 240 mm x 216 mm x 142 mm ekg 460 mm x 475 mm x 225 mm 15kg 150 mm x 120 mm x 70 mm 1.5kg UMKA-04 (Din-4, Dout-6, Ain-16, Aout-0) Additional Options Digital Module TMO1 Analog Module TMO1 ‘Adam TMO1 Trio! High-Voltage Choke IP20 Trio! High-Voltage Choke IP56 Triol Test unit TMO1 Triol High-Voltage Choke Flexible (|P56) DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 16 digital inputs /8 digital outputs 8 digital outputs Adapter RS485/422/232 Ethernet 230x460x142mm, 24 kg, 1P20 from -40 to +60°C (from -40 °F to +140 °F) 230x460x142mm, 24 kg, IPS6 from -40 to +60°C (from -40 *F to +140 *F) 454x324x17 1mm, 11 kg, IP67 from -40 to +55°C (from -40 °F to #131 °F), 4h 323x414x231mm, 24 kg, IPS6 from -20 to +60°C (from -4 *F to +140 *F) 7 ‘Triol High-Voltage Choke Flexible (IP00) 320x280x165mm, 22 kg, POO from -20 to +60°C (from -4 °F to +140 °F) ‘SCP Modern Modem type depends on the region of implementation ‘TM01-25 lineup ry Digital een Pa ey Cy Cred ey housing coating Bo Carbon steel with TMO1-25-P-20 phosphated 120 none none coating Carbon steel with TMO1-25-C-20 coating 120 none none 18-chrome Stainless steel TM01-25-S-20 Aaa P20 none none Carbon steel with TMO01-25-P-56 phosphated P56 16 416 coating Carbon steel with TM01-25-0-56 coating 156 16 46 18-chrome Stainless steel ‘TM01-25-S-56 eae IP56 16 a6 Options available ou Eee a) Digital Module TMO1 Inside VSD or surface unit cabinet ‘Analog Module TMO1 Inside VSD or surface unit cabinet ‘Adam TMO1 Inside VSD or surface unit cabinet Triol High-Voltage Choke 1P20 Exterior Triol High-Voltage Choke IP56 Exterior Triol High-Voltage Chohe Flexible Exterior Trio! Test unit TMO1 Exterior Trio! Test unit pressure TMO1 Exterior SCP Modem Inside VSD or inside surface unit cabinet DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 18 DOWNHOLE MEASURING SYSTEM Triol TMO1-20 Downhole Measuring System Triol TMO1-20 is a unique, high quality, and reliable solution with long service life, for efficiently collecting, processing, displaying and transferring submersible unit data and well data, at fluid temperature up to 150°C (302"F), fluid temperature at pump discharge up to 250°C (428°F), and equipment suspension zone pressure up to 40 MPa (5800psi).. elu Rar RR Cur Ll) @g - Pump discharge pressure fig | Pump discharge temperature CB - submersible motor lubricant temperature, motor temperature, or stator winding value = Motor vibration in X, ¥ and Z axis Triol TMO1 Surface Unit 7 - Insulation resistance in the triangle circuit (transformer-cable-motor) ‘TMO1- 20 Surface Board + Can be installed into VSD for communicating data with IP20 enclosure. TM01-20 Surface Panel + Can be installed remotely from VSD, in a protected case within IP56 enclosure and with UMKA-04 controller to display data via monitor and indicator lights DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 20 Options available (ordered separately) * Digital and Analog 1/0 Module TM01 + Supports, adapters, and flanges for connecting submersible units to various size motors and ESPs + Exterior Triol High-Voltage Choke to create an artificial Wye point in step-up transformers. + Triol Diagnostic Test Unit TM01, for controlling and monitoring operability of the TM01-20 system and control equipment during its assembly, installation and operation * SCP Modem for wireless transfer of collected data oye Tb ae Triol High-Voltage Choke can be configured in two different enclosures: + IP20 (for installation into the power transformer) + IP56 (for installation near the power transformer, in a separate case) Triol TM01-20 consists of two blocks: + Surface unit located inside the VSD, or separately in a protected case + Submersible unit attached to motor bottom DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 21 TM01-20 Specifications Key Parameters Ambient temperature Motor oil temperature / Motor stator winding Pump intake pressure ‘Axis vibration x,y, 2 Insulation resistance “Step-up transformer ~ motor power line” Insulation resistance "Step-up transformer - motor power line” Operation mode (duration) Data update time Controller communication protocol Communication protocol Step-up transformer /Submersible unit Communication protocol Surface unit /VSD Up to #150 °C #1°C (32-302°F #1,8°F) constantly, Fesolution 0,01°C (0,1°F) From 0 to +200/250 °C 41°C (82-392/482"F (#1,8°F), discreteness 0,01°C (0,1°F) (0-40 MPa (0-5800 psi) +0,05 MPa (+6 psi), resolution 0,001 MPa (0,1 psi) 0-30 m/s* (0-3,06 g) +5 %, resolution 0,1 m/s* (0.001 ) 0-100 ka (+5 %) resolution 1 kO / 0-10 mA 45%, (0,001 mA) 1000-10000 ka (#10 %) resolution 1 kA Extended 308 RS-232, RS-485 Modbus RTU Closed /Transfer Triol /Transfer ‘Submersible Unit Parameters Maximum operation pressure in submersible in suspension units zone Maximum operation temperature Submersible unit length ‘Submersible unit outside diameter, not more than Submersible unit weight, not more than ‘Submersible unit material ‘Submersible unit end details material ‘Submer le unit coating 40 MPa (5800 psi) 40,5 % #150 °C (302°F) 613 mm 103 mm 25kg Stainless steel 18 chrome Stainless steel 13 chrome Carbon steel with coating 18 chrome Ard Rated voltage Frequency Power consumption, not more than Ambient temperature Relative humidity under +25°C, without condensation Operating voltage in the communication circuit with submersible unit (if the insulation of Step-up ~ motor cable (system is in operation condition) DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 220 V (20%), 110 (210%) 50/60 Hz (+ 2 %) 1P20-40 W IP56 - 300 W from -40 *C to +75 °C (-40°F +167°F) 100 % 100 22 Attitude, not more than Enclosure, not less than Duration mode Overall dimensions IP20, not more than Weight 1P20, not more than Overall dimensions IP56, not more than Weight IP56, not more than Overall dimensions Surface Card IP20, not more than Weight Surface Card IP20, not more than Surface Panel display 1000 m 1P20/ P56 Extended 240 mm x 216 mm x 142 mm ekg 460 mm x 475 mm x 225 mm 15kg 150 mm x 120 mm x 70 mm 1.5kg UMKA-04 (Din-4, Dout-6, Ain-16, Aout-0) Additional Options Digital Module TMO1 Analog Module TMO1 ‘Adam TMO1 Trio! High-Voltage Choke IP20 Trio! High-Voltage Choke IP56 Triol Test unit TMO1 Triol Test unit pressure TMO1 Trio! High-Voltage Choke Flexible (IP56) Trio! High-Voltage Choke Flexible (P00) ‘SCP Modem DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 16 digital inputs /8 digital outputs 8 digital outputs Adapter RS485/422/232 Ethernet 230x460x142mm, 24 kg, IP20 from -40 to +60°C (from -40 “F to +140 °F) 230x460x142mm, 24 kg, IP56 from -40 to +60°C (from -40 °F to +140 °F) 454x324x171mm, 11 kg, P67 from -40 to +55°C (from -40 °F to +131 °F), 4h 454x324x17 1mm, 9 kg, IP67 from -20 to +60°C (from -4 °F to +140 °F) 323x414x231mm, 24 kg, IPS6 from -20 to +60°C (from-4 °F to +140 °F) 320x280x166mm, 22 kg, IPOO from -20 to +60°C (from -4 °F to +140 °F) Modem type depends on the region of implementation 23 TMO01-20 lineup Sree Digital ro Srey fed ro peste en housing coating ers Carbon steel with TMO1-20-P-20 phosphated 120 none none coating Carbon steel with: TM01-20-C-20 coating IP20 none none 18-chrome_ Stainless steel TM01-20-S-20 18-chrome P20 none none Carbon steel with TM01-20-P-56 phosphated (P56 16 4/6 coating Carbon steel with: TM01-20-C-56 coating IPs6 16 4/6 18-chrome_ Stainless steel TM01-20-S-56 18-chrome (P56 16 4/6 Options available Item Tee Digital Module TMO1 Inside VSD or surface unit cabinet Analog Module TMO1 Inside VSD or surface unit cabinet ‘Adam TMO1 Inside VSD or surface unit cabinet ‘Triol High-Voltage Choke 1P20 Exterior Triol High-Voltage Choke IP56 Exterior Triol High-Voltage Chohe Flexible Exterior Triol Test unit TMO1 Exterior Triol Test unit pressure TMO1 Exterior Simulator TMOTi Exterior SCP Modem Inside VSD or inside surface unit cabinet DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 DOWNHOLE MEASURING SYSTEM Triol TMO1-18 Triol Downhole Measuring System TMO1-18 is a rugged, high quality, reliable, and affordable solution suitable for high temperature fluid environments up to 175°C (347°F), for efficiently collecting, processing, displaying and transferring submersible unit data and well data, at ‘equipment suspension zone pressure up to 40 MPa (5800psi) ETUC Br Ri Belt © - Pump discharge pressure 22 I - Pump discharge temperature - Submersible motor lubricant temperature, motor temperature, or stator winding value A a Triol TMO1 Surface Unit - Motor vibration in X, Y and Z axis - Insulation resistance in the triangle circuit (transformer-cable-motor) TMO01-18 Submersible Unit + Made of stainless steel 18 chrome. TMO1-18 Surface Board + Can be installed into VSD for communicating data with IP20 enclosure. TM01-18 Surface Panel + Can be installed remotely from VSD, in a protected case within IP56 enclosure and with UMKA-04 controller to display data via monitor and indicator lights DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 26 Triol TM01-18 provides efficient and reliable performance, at an ambient temperature of up to 175°C (347°F). The system uses Peltier elements in the submersible unit, for superb cooling of electronics units due to the unique patented method of powering Peltier elements. Surface unit includes the Peltier power supply unit (cooler), which is located in a separate case and installed next to the VSD. Connection with the submersible unit is provided via motor submersible cable. Options available (ordered separately) —— { i) * Digital and Analog 1/0 Module TM01 * Supports, adapters, and flanges for connecting submersible “ units to various size motors and ESPs * Exterior Triol High-Voltage Choke to create an artificial Wye point in step-up transformers 2 + Triol Diagnostic Test Unit TM01, for controlling and monitoring G operability of the TM01-18 system and control equipment ¥ s during its assembly, installation and operation * SCP Modem for wireless transfer of collected data Triol High-Voltage Choke can be configured in two different enclosures: + P20 (for installation into the power transformer) + IP56 (for installation near the power transformer, in a separate case) Triol TM01-18 consists of two blocks: + Surface unit located inside the VSD, or separately in a protected case + Submersible unit located inside the VSD, or separately attached to motor bottom DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 27 TM01-18 Specifications Perec Ambient temperature Motor oil temperature / Motor stator winding Pump intake pressure Axis vibration x,y,z Insulation resistance "Step-up transformer ~ motor power line” Oper mode (duration) Data update time Controller communication protocol Communication protocol Step-up transformer /Submersible unit Communication protocol Surface unit /VSD Up to 175 °C (347°F) From 0 to +200/ 250 °C 41°C (892°F -482 °F +1,8°F), resolution 0,01°C (0,1°F) (0-40 MPa (0-5800 psi) #0,1 MPa (#15 psi), resolution 0,001 MPa (0,1 psi) 0-30 m/s? (0-3,06 g) #5 %, resolution 0,1 m/s* (0.001 g) 1000-10000 kA #10 %, discreteness 1k Extended 50s RS-232, RS-485 Modbus RTU Closed ‘Triol /Transfer Pee Maximum operation pressure in submersible in suspension units zone Maximum operation temperature ‘Submersible unit length( unsupported) ‘Submersible unit outside diameter, not more than Submersible unit weight, not more than Submersible unit material ‘Submersible unit coating 40 MPa (5800 psi) #05 % 175°C (347°F) 810 mm. 103 mm, 30 kg Stainless steel 18 chrome none Are ey Rated voltage 220 V (£20 % ), 110 V (410 % ) Frequency 50/60 Hz (+ 2%) Power consumption, not more than 120-40 W 1P56 - 300 W ‘Ambient temperature -60°C ...+75°C (76°F .. #167 °F) Relative humidity under +25°C, without 100% condensation Operating voltage in the communication 100 circuit with submersible unit (ifthe insulation of Step-up ~ motor cable (system is in operation condition) Attitude, not more than 1000 m Enclosure, not less than 1P20/ 1P56 Duration mode Extended DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 28 Overall dimensions IP20, not more than Weight IP20, not more than Overall dimensions IP56, not more than Weight IP56, not more than Surface Panel display 240 mm x 216 mm x 142. mm 6kg 460 mm x 475 mm x 225 mm 15kg UMKA-04 (Din-4, Dout-6, Ain-16, Aout-0) RL la ceca) Rated voltage Frequency Power consumption, not more than Power consumption, not more than Relative humidity under +25°C, without condensation Attitude, not more than Enclosure GOST 14254, not less than Duration mode Overall dimensions, not more than. Weight, not more than 220 V #30 % 50 Hz 800 W -40°C 100% +50 °C (40°F... +122 °F) 1000 m 1P54 Extended 606 mm x 480 mm x 280 mm 30kg ere ey Digital Module TMO1 ‘Analog Module TMO1 ‘Adam TMO1 Triol High-Voltage Choke IP20 Triol High-Voltage Choke IP56 Triol Test unit TMO1 ‘Triol Test unit pressure ‘SCP Modem TMO01-18 jeup Triol range 16 digital inputs /8 digital outputs 8 digital outputs Adapter RS485/422/232 Ethernet 230x460x142mm, 24 kg, IP20 from -40 to +60°C (from -40 °F to #140 °F) 230x460x142mm, 24 kg, IPS6 from -40 to +60°C (from -40 °F to #140 °F) 454x324x171mm, 11 kg, IP67 from -40 to +55°C (from -40 *F to +131 “F), 4h T™01 454x324x171mm, 9 kg, IP67 from -20 to #60°C (from -4°F to +140 °F) Modem type depends on the region of implementation Ete Peed eee) rel ay ee ed eet’ EO TMO1-18-S-56 DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 Stainless steel 18 chrome te? 16 46 29 Options available fou) Tua Ute) Digital Module TM01 Inside VSD or surface unit cabinet ‘Analog Module TM01 Inside VSD or surface unit cabinet, ‘Adam TMO1 Inside VSD or surface unit cabinet Triol High-Voltage Choke IP20 Exterior Triol High-Voltage Choke IPS6 Exterior Triol Test unit TMO1 Exterior Triol Test unit pressure TMO1 Exterior ‘Simulator TMO1i Exterior ‘SCP Modem Inside VSD or inside surface unit cabinet DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 DOWNHOLE MEASURING SYSTEM Triol TMO1-15 Trio! Downhole Measuring System TMO1-15 is a high quality and reliable solution ideal for efficiently collecting, processing, displaying and transferring submersible unit data and well data, at fluid temperatures up to 150°C (302"), fluid temperature at pump discharge up to 250°C (428°F), and equipment suspension zone pressure up to 40 MPa (5800psi). Era Rua ea Rl are Reis (BJ ~Rureischarge pressure - Pump intake pressure Pump discharge temperature - Submersible motor lubricant temperature, A motor temperature, or stator winding value -Well fluid temperature - Motor vibration in X, Y and Z axis - Insulation resistance in the triangle circuit (transformer-cable-motor) Triol TMO1 Surface Unit TMO01-15 submersible unit + Made of carbon steel with phosphated coating. + Made of stainless steel 18 chrome. TMO1- 15 Surface Board + Can be installed into VSD for communicating data with IP20 enclosure. TMO1- 15 Surface Panel + Can be installed remotely from VSD, in a protected case within IP56 enclosure and with UMKA-04 controller to display data via monitor and indicator lights. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 32 Options available (ordered separately) * Digital and Analog 1/0 Module TM01 + Supports, adapters, and flanges for connecting submersible units to various size motors and ESPs * Exterior Triol High-Voltage Choke to create an artificial Wye point in step-up transformers + Triol Diagnostic Test Unit TM01, for controlling and monitoring operability of the TM01-15 system and control equipment during its assembly, installation and operation 1 + SCP Modem for wireless transfer of collected data Trio! High-Voltage Choke can be configured in two different enclosures: + IP20 (for installation into the power transformer). + IP56 (for installation near the power transformer, in a separate case). Triol TM01-15 consists of three blocks: + Surface unit located inside the VSD, or separately in a protected case. + Submersible unit attached to motor bottom. + Submersible unit located between the pump and tubing; communication with submersible units is via two channels engineered with stainless steel tubes; the first is filled with formation fluid, to control pump discharge pressure; the second contains a conductor with a temperature sensor inside; electronics for processing pressure and temperature signals are located in the lower submersible unit. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 33 TMO01-15 Specifications Ambient temperature Motor oil temperature / Motor stator winding Pump intake pressure Pump discharge pressure Pump discharge temperature Axis vibration x,y, 2 Insulation resistance "Step-up transformer ~ motor power line” Operation mode (duration) Data update time Controller communication protocol Communication protocol Step-up transformer /Submersible unit Communication protocol Surface unit /VSD Up to +125 °C - constantly Up +150 °C (32-302"F) - up to 6 months totally From 0 to +200°C (32-392°F) / 0-250°C (32-482"F) 42°C, resolution 0,01°C (0-40 MPa (0-5800 psi) +0,2 MPa (+30 psi), resolution 0,001 MPa (0,1 psi) 0-40 MPa (0-5800 psi) 10,2 MPa (#30 psi), resolution 0,001 MPa (0,1 psi) 0-250 °C (32-428°F) +2°C (43,6°F), resolution 0,01°C (o'r) 0-30 m/s? (0-3,06 g) #5 %, resolution 0,1 m/s? 1000-10000 ka (+5 %), resolution 1 kO 1000-10000 ka (#10 %), resolution 1 ko Extended 30s RS-232, RS-485 Modbus RTU Closed Triol /Transfer ‘Submersible Unit Parameters Maximum operation pressure in submersible in suspension units zone Maximum operation temperature of the bottom submersible unit Maximum operation temperature of the top submersible unit Bottom submersible unit length( unsupported) Top submersible unit length, not more than Bottom submersible unit outside diameter, ot more than Top submersible unit outside diameter, not more than Bottom submersible unit weight, not more than Top submersible unit weight, not more than Submersible unit material Submersible unit end details material ‘Submersible unit coating Seamless stainless steel tube 316L with fittings Seamless stainless stee! tube 316L. with fitings and temperature sensor DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 40 MPa (5800 psi) #0,5 % +150 °C (302°F) +250 °C (482 °F) 690 mm, 250 mm, 103 mm, 110 mm, 22kg kg Stainless steel 18 chrome Stainless steel 13 chrome Carbon steel with coating 18-chrome ‘TC-1/4 in-3161 (50m) TC-1/4 in -316L. (50m) + thermal couple Pt1000 34 Aree Rated voltage Frequency Power consumption, not more than ‘Ambient temperature Relative humidity under +25°C, without condensation Operating voltage in the communication circuit with submersible unit (if the insulation of Step-up ~ motor cable (system is in operation condition) Attitude, not more than Enclosure, not less than Duration mode 220 V (#20 %), 110 V (10 % ) 50/60 Hz (2%) 1p20-40 W IP56-300 W from -40 °C to +75 °C (-40°F #167°F) 100% 100 1000 m 1P20 /1P56 Extended Overall dimensions IP20, not more than Weight 1P20, not more than Overall dimensions IP56, not more than Weight IP56, not more than Overall dimensions Surface Card IP20, not more than Weight Surface Card IP20, not more than Surface Panel display 240 mm x 216 mm x 142 mm ekg 460 mm x 475 mm x 225 mm 15k 150 mm x 120 mm x 70 mm Ain-16, Aout-0) Eee aed Digital Module TMO1 Analog Module TMO1 ‘Adam TMO1 Trio! High-Voltage Choke IP20 Trio! High-Voltage Choke IP56 Triol Test unit TMO1 Triol Test unit pressure TMO1 Triol High-Voltage Choke Flexible (|P56) Trio! High-Voltage Choke Flexible (|P00) ‘SCP Modem DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 16 digital inputs /8 ital outputs 8 digital outputs Adapter RS485/422/232 Ethernet 230x460x142mm, 24 kg, IP20 from -40 to +60°C (from -40 *F to +140 °F) 230x460x142mm, 24 kg, IPS6 from -40 to +60°C (from -40 *F to +140 °F) 454x324x171mm, 11 kg, IP67 from -40 to +55°C (from -40 *F to +131 °F), 4h 454x324x17 1mm, 9 kg, IP67 from -20 to +60°C (from -4 °F to +140 °F) 323x414x231mm, 24 kg, IPS6 from -20 to +60°C (from -4 °F to +140 °F) 320x280x165mm, 22 kg, IPOO from -20 to +60°C (from -4 °F to +140 °F) Modem type depends on the region of implementation 35 TMO1-15 lineup Arr’ Orel ray pete ad Ey By block ares ee) pre Carbon steel with, TMO1-15-P-20 phosphated 120 none none coating chrome 18 Carbon steel with TMO1-15-C-20 coating P20 none none 18-chrome Stainless steel 18 TM01-15-5-20 ama P20 none none Carbon steel with TMO1-15-P-56 phosphated IPs6 16 4/6 coating chrome 18 Carbon steel with TMO1-15-C-56 coating IPs6 16 4/6 18:-chrome Stainless steel 18 TMO1-15-S-56 chrome IPs6 16 46 Options available fou Tue ee Digital Module TMO1 Inside VSD or surface unit cabinet ‘Analog Module TMO1 Inside VSD or surface unit cabinet ‘Adam TMO1 Inside VSD or surface unit cabinet ‘Triol High-Voltage Choke 1P20 Exterior Triol High-Voltage Choke IP56 Exterior ‘Triol High-Voltage Chohe Flexible Exterior Triol Test unit TMO1 Exterior ‘Triol Test unit pressure TMO1 Exterior Simulator TMO1i Exterior SCP Modem Inside VSD or inside surface unit cabinet DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 DOWNHOLE MEASURING SYSTEM goa O ae Trio! Downhole Measuring System TMO1-05 is a sustainable and optimal solution for efficiently collecting, processing, displaying and transferring submersible unit data and well data, at fluid temperatures up to 150°C (302°F), fluid temperature at pump discharge up to 250°C (428°F), and equipment suspension zone pressure up to 40 MPa (5800psi). EPEC U atu ECR Bolte (@) _Rure discharge pressure ~ Pump intake pressure = 2 - Submersible motor lubricant temperature, motor temperature, or stator winding value A - Well fluid temperature g) i“ - Motor vibration in X, Y and Z axis - Insulation resistance in the triangle circuit Triol TMO1 Surface Unit (transformer-cable-motor) TMO1-05 submersible unit + Made of carbon steel with phosphated coating, + Made of stainless steel 18 chrome. TMO1- 05 Surface Board + Can be installed into VSD for communicating data with IP20 enclosure. TM01- 05 Surface Panel + Can be installed remotely from VSD, in a protected case within IPS6 enclosure and with UMKA-04 controller to display data via monitor and indicator lights DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 38 Options available (ordered separately) + Digital and Analog 1/0 Module TM01 * Supports, adapters, and flanges for connecting submersible units to various size motors and ESPs * Exterior Triol High-Voltage Choke to create an artificial Wye point in step-up transformers + Triol Diagnostic Test Unit TMO1, for controlling and monitoring operability of the TM01-05 system and control equipment during its assembly, installation and operation * SCP Modem for wireless transfer of collected data Triol High-Voltage Choke can be configured in two different enclosures: + IP20 (for installation into the power transformer) + IP56 (for installation near the power transformer, in a separate case). Triol TM01-15 consists of three blocks: + Surface unit located inside the VSD, or separately in a protected case. + Submersible unit attached to motor bottom. + Submersible unit located between the pump and tubing; communication with submersible units is via two channels engineered with stainless steel tubes; the first is filled with formation fluid, to control pump discharge pressure; the second contains a conductor with a temperature sensor inside; electronics for processing pressure and temperature signals are located in the lower submersible unit. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 39 TMO01-05 Specifications Key Parameters Ambient temperature Motor oil temperature / Motor stator winding Pump intake pressure Pump discharge pressure Axis vibration x,y,z Insulation resistance “Step-up transformer ~ motor ower line” Operation mode (duration) Data update time Controller communication protocol Communication protocol Step-up transformer /Submersible unit Communication protocol Surface unit /VSD Up to #125 °C - constantly Up +150 °C (32-302°F) ~ up to 6 months totally From 0 to +200 /250 °C (392- 482°F) 42°C, (+3,6°F), resolution 0,01°C (0,1°F) 0-40 MPa (0-5800 psi) 0,2 MPa (#30 psi), resolution 0,001 MPa (0,1 psi) (0-40 MPa (0-5800 psi) +0,2 MPa (+30 psi), resolution 0,001 MPa (0,1 psi) 0-30 m/s? (45 %), resolution 0,1 m/s? (0.001 g) 0-1000 ka (£10 %), resolution 1 kQ / 1000-10000 kA #10 %, resolution 1k Extended 308 RS-232, RS-485 Modbus RTU Closed Triol/Transfer ‘Submersible Unit Parameters Maximum operation pressure in submersible in suspension units zone Maximum operation temperature of the bottom submersible unit Maximum operation temperature of the top submersible unit Bottom submersible unit length( unsupported) Top submersible unit length, not more than Bottom submersible unit outside diameter, not more than Top submersible unit outside diameter, not more than’ Bottom submersible unit weight, not more than Top submersible unit weight, not more than Submersible unit material Submer le unit end details material Submersible unit coating Seamless stainless steel tube 316L with fittings Seamless stainless steel tube 316L with fittings and temperature sensor DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 2 40 MPa (5800 psi) #0,5 % +150 °C (02°F) +250°C (482 °F) 690 mm, 250 mm, 103 mm, 110mm, 22kg 8kg Stainless steel 18 chrome Stainless steel 13 chrome Carbon steel with coating 18-chrome TC-1/4 in -316L (50m) ‘TC-1/4 in-316L (50m) + thermal couple Pt1000 40 Re od Rated voltage 220 V (#20 % ), 110 V (#10 %) Frequency 50/60 Hz (+ 2%) Power consumption, not more than 120-40 W IPS6 - 300 W Ambient temperature from -40 °C to +75 °C (40°F +167°F) Relative humidity under +25°C, without 100% condensation Operating voltage in the communication 100V corcuit with submersible unit (if the insulation of Step-up ~ motor cable (system is in operation condition) Attitude, not more than 1000 m Enclosure, not less than 1P20 / IPS6 Duration mode Extended Overall dimensions IP20, not more than 240 mm x 216 mm x 142 mm. Weight IP20, not more than kg Overall dimensions IPS6, not more than 460 mm x 475 mm x 225 mm. Weight IP56, not more than 15kg Overall dimensions Surface Card IP20, ot more than Weight Surface Card IP20, not more than Surface Panel display 150 mm x 120 mm x 70 mm 1.5kg UMKA-04 (Din-4, Dot Aout-0) Eee ay Digital Module TMO1 Analog Module TMO1 ‘Adam TMO1 Trio! High-Voltage Choke IP20 Trio! High-Voltage Choke IP56 Triol Test unit TMO1 ‘Triol Test unit pressure TMO1 Triol High-Voltage Choke Flexible (1P56) ‘Triol High-Voltage Choke Flexible (1P00) SCP Modem DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 16 digital inputs/ 8 digital outputs 8 digital outputs Adapter RS485/422/232 Ethernet 230x460x142mm, 24 kg, P20 from -40 to +60°C (from -40 °F to +140 °F) 230x460x142mm, 24 kg, IP56 from -40 to +60°C (from -40 °F to +140 °F) 484x324x171mm, 11 kg, IP67 from -40 to +55°C (from -40 *F to +131 °F), 4h 454x324x171mm, 9 kg, IP67 from -20 to +60°C (from -4 °F to +140 °F) 323x414x231mm, 24 kg, IP56 from -20 to +60°C (from -4 *F to +140 °F) 320x280x165mm, 22 kg, IPOO from -20 to +60°C (from -4 “F to +140 °F) Modem type depends on the region of implementation a TMO1-05 lineup Sry Oe ay pete ory available Ey block ares eu en) pen Carbon steel with, TMO1-05-P-20 phosphated 120 none none coating Carbon steel with, TM01-05-C-20 phosphated P20 none none coating 18 chrome Stainless steel 18 ‘TMO1-05-S-20 ‘chrome 120 none none Carbon steel with TMO1-05-P-56 phosphated IPs6 16 46 coating Carbon steel with TMO01-05-C-56 coating P56 16 46 18-chrome Stainless steel 18 TMO1-05-S-56 chrome IPs6 16 46 Options available tem ‘Submersible unit coating Digital Module TMO1 Inside VSD or surface unit cabinet ‘Analog Module TMO1 Inside VSD or surface unit cabinet ‘Adam TMO1 Inside VSD or surface unit cabinet Trio! High-Voltage Choke IP20 Exterior Triol High-Voltage Choke IP56 Exterior ‘Triol High-Voltage Chohe Flexible Exterior Triol Test unit TMO1 Exterior Trio! Test unit pressure TMO1 Exterior Simulator TMO1i Exterior SCP Modem Inside VSD or inside surface unit cabinet DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 DOWNHOLE MEASURING SYSTEM Triol TMO1-1e Triol Downhole Measuring System TMO1-12 is proven in the field as a highly reliable solution with an extended service life ideal for efficiently collecting, processing, displaying and transferring submersible unit data and well data, at fluid temperatures up to 150°C (302°F) and equipment ‘suspension zone pressure up to 40 MPa (5800psi). ETT eU auc Ro Ril ii Bolte Q ~ Pump intake pressure Gy (Sze wining value - Well fluid temperature - Motor vibration in X, Y and Z axis - Insulation resistance in the triangle circuit (transformer-cable-motor) Triol TMO1 Surface Unit TM01-12 submersible unit + Made of carbon stee! with phosphated coating. + Made of stainless steel 18 chrome. TMO1- 12 Surface Board + Can be installed into VSD for communicating data with IP20 enclosure. ‘TMO1- 12 Surface Panel + Can be installed remotely from VSD, in a protected case within IP56 enclosure and with UMKA-04 controller to display data via monitor and indicator lights. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 44 The submersible unit of the TM01-12 includes two sub units ~ the main and the backup unit. The surface unit in the system provides power for the two submersible units. In the absence of data from one submersible unit, the surface unit automatically activates the second submersible unit, thus ensuring a continuous flow of data from the well. Options available (ordered separately) * Digital and Analog I/O Module TM01 + Supports, adapters, and flanges for connecting submersible units to various size motors and ESPs * Exterior Triol High-Voltage Choke to create an artificial Wye point in step-up transformers + Triol Diagnostic Test Unit TMO1, for controlling and monitoring operability, of the TMO1-12 system and control equipment during its assembly, installation and operation Triol High-Voltage Choke can be configured in two different enclosures: + 1P20 (for installation into the power transformer) + IP56 (for installation near the power transformer, in a separate case). Triol TM01-12 consists of two blocks: + Surface unit located inside the VSD, or separately in a protected case. + Submersible unit attached to motor bottom. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 45 TM01-12 Specifications Cauca Ambient temperature Motor oil temperature / Motor stator winding Pump intake pressure Axis vibration x.y, 2 Insulation resistance "Step-up transformer ~ motor power line” Operat in mode (duration) Data update time Controller communication protocol Communication protocol Step-up transformer /Submersible unit Communication protocol Surface unit /VSD Up to #125 “C - constantly Up to +150 °C - up to 1 year totally From 0 to +200 /250 °C (from 32 to +392/482 °F) 42°C, (43,6°F), resolution 0,01°C (0,1°F) (0-40 MPa (0-5800 psi) 10,2 MPa (#30 psi), resolution 0,001 MPa (0,1 psi) 0-30 m/s* (0-3,06 g) +5 %, resolution 0,1 m/s? (0.001 g) 0-1000 ka (#5 %), resolution 1 kO 1000-10000 ka (+10 %), resolution 1 KO Extended 30s RS-232, RS-485 Modbus RTU Closed Triol /Transfer Pee auc ‘Submersible units number Maximum operation pressure submersible unit in suspension zone ‘Submersible unit rated temperature ‘Submersible unit maximum operating ‘temperature ‘Submersible unit length (unsupported) ‘Submersible unit outside diameter, not more than Submersible unit weight, not more than Submersible unit material Submersible unit end detail material ‘Submersible unit coating 2 40 MPa (5800 psi) 40,5 % #150 °C (302°F) +150°C (202°F) 2x613 mm 103 mm, 2X25 kg Stainless steel 18 chrome Stainless steel 13 chrome Carbon Steel with coating 18 chrome Ar ad Rated voltage Frequency Power consumption, not more than Ambient temperature Relative humidity under +25°C, without condensation DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 220 V (420%), 110 V (#10 %) 50/60 Hz (+2 %) 1p20-40 W IP56-300 W from -40 "C to +75 °C (-40°F +167°F) 100% 46 Operating voltage in the communication circuit with submersible unit (if the insulation of Step-up ~ motor cable (system is in operation condition) 200 Attitude, not more than Enclosure, not less than Duration mode Overall dimensions IP20, not more than Weight IP20, not more than Overall dimensions IPS6, not more than Weight IP56, not more than Surface Panel display 1000 m 1P20 / P56 Extended 240 mm x 216 mm x 142 mm 6 kg 460 mm x 475 mm x 225 mm Aout-0) Eee ay Digital Module TMO1 Analog Module TMO1 Adam TMO1 Trio! High-Voltage Choke IP20 Triol High-Voltage Choke IP56 Triol Test unit TMO1 Triol Test unit pressure TMO1 ‘SCP Modem DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 16 digital inputs /8 digital outputs 8 digital outputs Adapter RS485/422/232 Ethernet 230x460x142mm, 24 kg, P20 from -40 to +60°C (from -40 °F to +140 °F) 230x460x142mm, 24 kg, IPS6 from -40 to +60°C (from -40 °F to +140 °F) 454x324x17 1mm, 11 kg, IP67, from -40 to +55°C (from -40 °F to +131 °F), 4h 484x324x171mm, 9 kg, IP67, from -20 to +60°C. (from -4 °F to +140 °F) Modem type depends on the region of implementation 47 TMO1-12 lineup Sry Oe OL pete rr available Ey block ares eu en) pen Carbon steel with, TMO1-12-P-20 phosphated 120 none none coating Carbon steel with, TM01-12-C-20 phosphated P20 none none coating 18 chrome Stainless steel 18 TMO1-12-8-20 ama P20 none none Carbon steel with TMO1-12-P-56 phosphated P56 16 416 coating Carbon steel with TMO1-12-C-56 coating P56 16 4/6 18-chrome Stainless steel 18 TMO1-12-S-56 chrome IPs6 16 46 Options available feu Aiea) Digital Module TMO1 Inside VSD or surface unit cabinet ‘Analog Module TM01 Inside VSD or surface unit cabinet ‘Adam TMO1 Inside VSD or surface unit cabinet Triol High-Voltage Choke 1P20 Exterior Triol High-Voltage Choke IP56 Exterior Trio! Test unit TMO1 Exterior Triol Test unit pressure TMO1 Exterior Simulator TMOTi Exterior SCP Modem Inside VSO or inside surface unit cabinet DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 DOWNHOLE MEASURING SYSTEM Triol TMO1-11 Triol Downhole Measuring System TMO1-11 is a specially designed, reliable solution for working with low-frequency motors (from 5 Hz) to collect, process, display and transfer submersible unit data and well data, at fluid temperatures up to 150°C (02°F) and equipment suspension zone pressure up to 40 MPa (5800psi). ETUC Rr Ril aii Belts QQ _- Pump intake pressure - Stator winding value - Well fluid temperature = Motor vibration in X, Y and Z axis G@ - Insulation resistance in the triangle circuit Triol TMO1 Surface Unit (transformer-cable-motor) TM01-11 Submersible unit + Made of carbon steel with phosphated coating. + Made of stainless steel 18 chrome. TMO1- 11 Surface Board + Can be installed into VSD for communicating data with IP20 enclosure. TMO1- 11 Surface Panel + Can be installed remotely from VSD, in a protected case within IP56 enclosure and with UMKA-04 controller to display data via monitor and indicator lights DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 50 Options available (ordered separately) Digital and Analog I/O Module TM01 Supports, adapters, and flanges for connecting submersible units to various size motors and ESPs Exterior Triol High-Voltage Choke to create an artificial Wye point in step-up transformers Triol Diagnostic Test Unit TMO1, for controlling and monitoring operability of the TM01-11 system and control equipment during its assembly, installation and operation IP56 (for installation near the power transformer, in a separate case) — Triol High-Voltage Choke can be configured in two different enclosures: + IP20 (for installation into the power transformer). + IP56 (for installation near the power transformer, in a separate case). Triol TM01-11 consists of two blocks: + Surface unit located inside the VSD, or separately in a protected case. + Submersible unit attached to motor bottom. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 51 TM01-11 Specifications Key Parameters ‘Ambient temperature Motor oil temperature Pump intake pressure i vibration x,y,z Insulation resistance "Step-up transformer ~ motor power line” Operation mode (duration) Data update time Controller communication protocol Communication protocol Step-up transformer /Submersible unit Communication protocol Surface unit /VSD Up to #125 *C ~ constantly Up to +150 °C ~ up to 6 months totally From 0 to +200 /250 °C (from 32 to +392/482 "F) 42°C, (#3,6°F), resolution 0,01°C (0,1"F) (0-40 MPa (0-5800 psi) +0,2 MPa (#30 psi), resolution 0,001 MPa (0,1 psi) 0-30 m/s? +5 %, resolution 0,1 m/s* 0-100 ka (#5 %), resolution 1 kO 1000-10000 ka (#10 %), resolution 1 KO Extended 20s RS-232, RS-485 Modbus RTU Closed Triol/Transfer ‘Submersible Unit Parameters Maximum operation pressure submersible unit in suspension zone ‘Submersible unit maximum operating temperature ‘Submersible unit length (unsupported) ‘Submersible unit outside diameter, not more than ‘Submersible unit weight, not more than ‘Submersible unit material ‘Submersible unit end detail material ‘Submersible unit coating 40 MPa (5800 psi) 40,5 % #150 °C (302"F) 613mm 103 mm 22kg Stainless steel 18 chrome Stainless steel 13 chrome Carbon Steel with phosphated coating 18 chrome ‘Surface Unit Parameters Rated voltage Frequency Power consumption, not more than Ambient temperature Relative hut condensation ity under +25°C, without Operating voltage in the communication circuit with submersible unit (if the insulation of Step-up ~ ESM motor cable (system is in operation condition) Attitude, not more than Enclosure, not less than DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 220 V (420%), 110 V (#10 %) 50/60 Hz (+2 %) 1P20 - 40 W IP56 - 200 W from -40 °C to +75 °C (40°F +167°F) 100 % 100 1000 m 1P20/ P56 52 Duration mode Overall dimensions 1P20, not more than Weight 1P20, not more than Overall dimensions IPS6, not more than Weight IP56, not more than Surface Panel display Extended 240 mm x 216 mm x 142. mm 6kg 460 mm x 475 mm x 225 mm 15kg, UMKA-04 (Din-4, Dout-6, Ain-16, Aout-0) Crone ales Digital Module TMO1 Analog Module TMO1 ‘Adam TMO1 Triol High-Voltage Choke IP20 Triol High-Voltage Choke IP56 Triol Test unit TMO1 Triol Test unit pressure TMO1 SCP Modem TM01-11 lineup Brees ed Sou ent’ 16 digital inputs /8 digital outputs 8 digital outputs Adapter RS485/422/232 Ethemet 230%460x142mm, 24 kg, 1P20 from -40 to +60°C (from -40 *F to +140 °F) 230x460x142mm, 24 kg, IPS6 from -40 to +60°C (from -40 *F to +140 °F) 454x324x171mm, 11 kg, IP67 from -A0 to +55°C (from -40 °F to #131 °F), 4h 454x324x171mm, 9 kg, IP67_ from -20 to +60°C (from -4"F to #140 °F) Modem type depends on the region of implementation rel nd Py Oey Ey eure) Carbon steel with phosphated coating Carbon steel with, phosphated coating 18 chrome TMO1-11-P-20 TMO1-11-C-20 Stainless steel 18 TMO1-11-S-20 chrome Carbon steel with phosphated coating Carbon steel with coating 18-chrome TMO1-11-P-56 TMO1-11-C-56 Stainless steel 18 TMO1-11-S-56 chrome DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 P20 120 IPS6 P56 IPS6 none none none none none none 16 4/6 16 46 16 46 53 Options available eu Bree aiken) Digital Module TMO1 Inside VSD or surface unit cabinet ‘Analog Module TMO1 Inside VSD or surface unit cabinet ‘Adam TMO1 Inside VSD or surface unit cabinet Triol High-Voltage Choke 1P20 Exterior Trio! High-Voltage Choke IP56 Exterior Trio! Test unit TMO1 Exterior Triol Test unit pressure TMO1 Exterior Simulator TMOTi Exterior SCP Modem Inside VSO or inside surface unit cabinet DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 DOWNHOLE MEASURING SYSTEM Trial TMO1-10 Triol Downhole Measuring System TMO1-10 is a product of advanced engineering and represents a high quality, reliable solution for efficiently collecting, processing, displaying and transferring submersible unit data and well data, at fluid temperatures up to 150°C (302°F) and equipment suspension zone pressure up to 40 MPa (5800psi). ET Rua Ra Rel ie ei Q) - Pump intake pressure - Stator winding value - Well fluid temperature - Motor vibration in X, Y and Z axis - Insulation resistance in the triangle circuit Triol TMO1 Surface Unit (transformer-cable-motor) TM01-10 Submersible unit + Made of carbon steel with phosphated coating. + Made of stainless steel 18 chrome. TMO1- 10 Surface Board + Can be installed into VSD for communicating data with IP20 enclosure. TMO1- 10 Surface Panel + Can be installed remotely from VSD, in a protected case within IP56 enclosure and with UMKA-04 controller to display data via monitor and indicator lights. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 56 Options available (ordered separately) * Digital and Analog 1/0 Module TM01 + Supports, adapters, and flanges for connecting submersible units to various size motors and ESPs + Exterior Trio! High-Voltage Choke to create an artificial Wye point in step-up transformers + Triol Diagnostic Test Unit TMO1, for controlling and monitoring operability of the TM01-10 system and control equipment during its assembly, installation and operation Triol High-Voltage Choke can be configured in two different enclosures: + IP20 (for installation into the power transformer). + IP56 (for installation near the power transformer, in a separate case). Triol TM01-10 consists of two blocks: + Surface unit located inside the VSD, or separately in a protected case. + Submersible unit attached to motor bottom. DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 57 TM01-10 Specifications Ambient temperature Motor oil temperature Pump intake pressure Axis vibration x, Insulation resistance "Step-up transformer ~ motor power line” Operation mode (duration) Data update time Controller communication protocol Communication protocol Step-up transformer /Submersible unit Communication protocol Surface unit /VSD Up to +125 °C - constantly Up to +150 °C - up to 6 months totally From 0 to +200 /250 °C (from 32 to +392/482 °F) 42°C, (+3,6°F), resolution 0,01°C (0,1"F) (0-40 MPa (0-580 psi) +0,2 MPa (+30 psi), resolution 0,001 MPa (0,1 psi) 0-30 m/s* +5 %, resolution 0,1 m/s* 0-100 ka (#5 %), resolution 1 KO 1000-10000 ka (+10 %), resolution 1 KO Extended 20s RS-232, RS-485 Modbus RTU Closed Triol/Transfer ‘Submersible Unit Parameters Maximum operation pressure submersible unit in suspension zone Submersible unit maximum operating temperature ‘Submersible unit length (unsupported) ‘Submersible unit outside diameter, not more than ‘Submersible unit weight, not more than ‘Submersible unit material ‘Submersible unit end detail material ‘Submersible unit coating 40 MPa (5800 psi) 30,5 % +150 °C (302"F) 613mm. 103 mm 22kg Stainless steel 18 chrome Stainless steel 13 chrome Carbon Steel with phosphated coating 18 chrome Arey Rated voltage Frequency Power consumption, not more than Ambient temperature Relative humidity under +25° condensation , without Operating voltage in the communication circuit with submersible unit (if the insulation of Step-up ~ ESM motor cable (system is in ‘operation condition) Attitude, not more than Enclosure, not less than DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 220 V (£20 %), 110 V (410 % ) 50/60 Hz (+ 2%) P20 - 40 w P56 - 200 W from -40 °C to +75 °C (-40°F +167°F) 100% 100 1000 m 1P20/ P56 58 Duration mode Overall dimensions IP20, not more than Weight 1P20, not more than Overall dimensions IP56, not more than Weight IP56, not more than Overall dimensions Surface Card IP20, not more than Weight Surface Card IP20, not more than Surface Panel display Extended 240 mm x 216 mm x 142 mm ekg 460 mm x 475 mm x 225 mm 15kg 150 mm x 120 mm x 70 mm 1.5k9 UMKA-04 (Din-4, Dout-6, Ain-16, Aout-0) Additional Options Digital Module TM01 Analog Module TMO1 ‘Adam TMO1 Triol High-Voltage Choke 1P20 Triol High-Voltage Choke IP56 Triol Test unit TMO1 Trio! Test unit pressure TMO1 Triol High-Voltage Choke Flexible (IP56) Trio! High-Voltage Choke Flexible (IP00) SCP Modem DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 16 digital inputs /8 digital outputs 8 digital outputs Adapter RS485/422/232 Ethemet 230x460x142mm, 24 kg, IP20 from -40 to +60°C (from -40 °F to +140 °F) 230x460x142mm, 24 kg, IPS6 from -40 to +60°C (from -40 °F to #140 °F) 454x324x17 1mm, 11 kg, IP67 from -40 to +55°C (from -40 °F to +131 °F), ah 454x324x171mm, 9 kg, IP67 from--20 to +60°C (from -4°F to +140 °F) 323x414x231mm, 24 kg, IP56 from -20 to +60°C (from -4 °F to +140 °F) 320x280x165mm, 22 kg, IPOO from -20 to +60°C (from -4°F to +140 °F) ‘Modem type depends on the region of, implementation 59 MO1-10 lineup ey Pe rea ste rr eres aT Des eet’ housing coating Bed Carbon steel with ‘TMO1-10-P-20 phosphated 1P20 none none coating Carbon steel with ‘TMO1-10--20 phosphated P20 none none coating 18 chrome rmor-10--20 Stainless steel 18 120 none none chrome Carbon steel with TMO1-10-56 phosphated 1P56 16 416 coating Carbon stee! with TM01-10-6-56 coating 1P56 16 416 1e-chrome rmor-10.s-55 Stainless steel 16 1PS6 16 4/6 chrome Options available few Areata) Digital Module TM01 Inside VSD or surface unit cabinet ‘Analog Module TMO1 Inside VSD or surface unit cabinet ‘Adam TMO1 Inside VSD or surface unit cabinet Triol High-Voltage Choke P20 Exterior Triol High-Voltage Choke IP56 Exterior Triol High-Voltage Chohe Flexible Exterior Triol Test unit TMO1 Exterior Triol Test unit pressure TMO1 Exterior Simulator TMOTi Exterior ‘SCP Modem Inside VSD or inside surface unit cabinet DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 Appendix (Additional options) All Triol TMO1 series models can be equipped with a variety of support accessories, including flanges, adapters, and ESPs from various manufactures. ro) Dey Motor base 96 Motor base 96-S Motor base 103, Motor base 103-S Motor base 114 Motor base 114-S Motor base 117 Motor base 117-S Motor base 130 Motor base 130-S Flange adapter 350 Flange adapter 350-S Flange adapter 450 Flange adapter 450-S Flange adapter 103 Flange adapter 103-S Flange adapter 114 Flange adapter 114-S Base for shaft electric submersible motor 96 overall size Carbon steel 40x, connection size as requested Base for shaft electric submersible motor 96 overall size Stainless steel 40X13, connection size as requested Base for shaft electric submersible motor 103 overall size Carbon steel 40X, connection size as requested Base for shaft electric submersible motor 103 overall size Stainless steel 40X13, connection size as requested Base for shaft electric submersible motor 114 Carbon steel 40X, connection size as requested Base for shaft electric submersible motor 114 Stainless steel 40X13, connection size as requested Base for shaft electric submersible motor 117 Carbon steel 40X, connection size as requested Base for shaft electric submersible motor 117 Stainless steel 40X13, connection size as requested Base for shaft electric submersible motor 130 Carbon steel 40X, connection size as requested Base for shaft electric submersible motor 130 Stainless steel 40X13, connection size as requested ‘Submersible unit connection flange 350 Carbon steel 40X, connection size as requested ‘Submersible unit connection flange 350 Stainless steel 40X13, connection size as requested ‘Submersible unit connection flange 450 Carbon steel 40X, connection size as requested ‘Submersible unit connection flange 450 Stainless steel 40X13, connection size as requested ‘Submersible unit connection flange 103 Carbon steel 40X, connection size as requested ‘Submersible unit connection flange 103 Stainless steel! 40X13, connection size as requested ‘Submersible unit connection flange 114 Carbon steel 40X, connection size as requested ‘Submersible unit connection flange 114 Stainless steel 40X13, connection size as requested DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 61 eo) Pca Flange adapter 117 Flange adapter 117-5 Motor Adapter 96 Motor Adapter 96-S Motor Adapter 103 Motor Adapter 103-S. Motor Adapter 114 Motor Adapter 114-5 Motor Adapter 117 Motor Adapter 117-5 Motor Adapter 130 Motor Adapter 130-5 Motor Adapter 420-S, Motor Adapter 456-5 Motor Adapter 540-5. Bottom Adapter type1 Bottom Adapter typel-S Bottom Adapter type2 Bottom Adapter type2-S ‘Submersible unit connection flange 117 Carbon steel 40X, connection size as requested ‘Submersible unit connection flange 117 Stainless steel 40X13, connection size as requested Electric submersible motor connection adapter 96 Carbon steel 40X, connection size as requested Electric submersible motor connection adapter 96 Stainless steel 40X13, connection size as requested Electric submersible motor connection adapter 103 Carbon steel 40x, connection size as requested Electric submersible motor connection adapter 103 Stainless steel! 40X13, connection size as requested Electric submersible motor connection adapter 114 Carbon steel 40X, connection size as requested Electric submersible motor connection adapter 114 Stainless steel 40X13, connection size as requested Electric submersible motor connection adapter 117 Carbon steel 40X, connection size as requested Electric submersible motor connection adapter 117 Stainless steel 40X13, connection size as requested Electric submersible motor connection adapter 130 Carbon steel 40x, connection size as requested Electric submersible motor connection adapter 130 Stainless steel 40X13, connection size as requested Electric submersible motor connection adapter 420 Stainless steel 40X13, connection size as requested Electric submersible motor connection adapter 456 Stainless steel! 40X13, connection size as requested Electric submersible motor connection adapter 540 Stainless steel! 40X13, connection size as requested ‘Submersible unit adapter for additional equipment installed at the bottom 2 3/8 pin to 2 7/8 box, Carbon steel 40X ‘Submersible unit adapter for additional bottom equipment installed at the bottom 2 3/8 pin to 2 7/8 box 40X13 Stainless steel 40X13 ‘Submersible unit adapter for additional bottom equipment installed at the bottom 2 3/8 pin to 2 7/8 box 2 3/8 pin to 3 1/2 box, , Carbon steel 40X ‘Submersible unit adapter for additional bottom equipment installed at the bottom 2 3/8 pin to 3 1/8 box 40X13 Stainless steel 40X13 DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 62 Available additional items to order TM01 Installation kit Installation tool kit TMO1 TM01 Filling valve Motor Filling valve Available additional items to order for TM01-05, -15, -25 Stainless Tube bobbin 250m ‘Seamless stainless tube TC-1/4 in -316L Fitting Kit TMO1 Fitting Kit for connecting stainless tubes with TMO1 ‘Submersible units It's possible to additionally equip Surface unit IP20 with IP56 and\or UMKA-04 controller UMKA-04, UMKA-04 controller with display for SCP SCP Cabinet Cabinet from SCP Cap for cabinet SCP Cap for cabinet SCP with sealed lead-in Electronic kit Electronic kit for UMKA-04 installation Pack SCP Pack for SCP cabinet Units included into TM01 can be ordered separately road TMO1-055 ‘TMO1-05 Surface Board IP20 ‘TMO1-05p TMO1-05 Surface Panel IP56 ‘TMO1-05e ‘Triol Surface Card TMO1-05¢ ‘TMO1-105 TM01-10 Surface Board IP20 ‘TMO1-10p ‘TMO1-10 Surface Panel IP56 TMO1-10¢ ‘Triol Surface Card TM01-10c TMO1-11b TM01-11 Surface Board IP20 TMO1-11p ‘TMO1-11 Surface Panel IP56 Two1-12b ‘TTM01-12 Surface Board IP20 ‘TMO1-12p TMO1- Surface Panel IP56 TMO1-150 ‘TMO1-15 Surface Board IP20 ‘TMO1-15p TM01-15 Surface Panel IPS6 ‘TMO1-15¢ Triol Surface Card TMO1-15¢ DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 63 TMO1-16p TMO1-16 Surface Panel IP56 TMO1-18p ‘TMO1-18 Surface Panel IP56 Two1-20b ‘TMO1-20 Surface Board IP20 TMO1-20 TMO1-20 Surface Panel IP56 TMO1-20¢ Triol Surface Card TM01-20c Two1-25b ‘TMO1-25 Surface Board IP20 TMO1-25p ‘TMOT-25 Surface Panel IP56 TMO1-25¢. Triol Surface Card TM01-25¢ TMO1-05-S Stainless steel Downhole intake sensor TM01-05 TMOT-05-C Carbon steel with coating 18 chrome Downhole intake sensor TM01-05 TMOT-05:-P Phosphated Downhole intake sensor TM01-05 TMO1-0-S Stainless steel Downhole intake sensor TM01-10 TMOT-10-C Carbon steel with coating 18 chrome Downhole intake sensor TMO1-10 TMOT-10-P Phosphated Downhole intake sensor TM01-10 TMOI-11-S Stainless steel Downhole intake sensor TMO1-11 TMOT-1-C Carbon steel with coating 18 chrome Downhole intake sensor TMO1-11 TMO1-11-P Phosphated Downhole intake sensor TMO1-11 TMO1-12-S Stainless steel Downhole intake sensor TM01-12 TMO1-12-C Carbon steel with coating 18 chrome Downhole intake sensor TM01-12, TMO1-5-S Stainless steel Downhole intake sensor TM01-15 TMOT-15-C Carbon steel with coating 18 chrome Downhole intake sensor TMO1-15, TMO1-18-S Stainless steel Downhole intake sensor TM01-18 TMO1-20-S Stainless steel Downhole intake sensor TM01-20 TMO1-20-6 Carbon steel with coating 18 chrome Downhole intake sensor TMO1-20 TMO1-25:S Stainless steel Downhole intake sensor TM01-25 TMOT-25-C Carbon steel with coating 18 chrome Downhole intake sensor TM01-25 TMO1-05¢-S Stainless steel Downhole discharge sensor TMO1-05 TMO1-05¢-P Phosphated Downhole discharge sensor TMO1-05 TMO1-15¢S Stainless steel Downhole discharge sensor TMO1-15 TMO1-25¢S Stainless steel Downhole discharge sensor TMO1-25 TMO1-20-S Triol Cooling power supply unit DOWNHOLE MEASURING SYSTEM - TRIOL TMO1 64

You might also like