Maintenance > Maintenance parts replacement procedures

(4)Developer section/Drum section


(4-1)Detaching and reattaching the inner unit
Procedures

1 Open the waste toner box cover (a).

4-34
[CONFIDENTIAL]
Maintenance > Maintenance parts replacement procedures

2 Pull out the conveying unit.

3 Remove two screws (a)(M4x8) and open the front middle cover (b).

4 Lock the developer waste exit that hasbeen released. (Refer P.2-15)

5 Remove the screw (c) and open the connector cover (d).

6 Disconnect the connector (e).

7 Release the wire saddle (f).

4-35
[CONFIDENTIAL]
Maintenance > Maintenance parts replacement procedures

8 Remove four fixing screws (b) of the inner unit (a).

9 Release the lock by pushing the fixing levers (b) at the right and left of inner unit (a).
10 Remove the inner unit (a).
11 Close the toner supply shutter (c) of the inner unit (a).
Be sure to unlock the developer waste exit after the inner unit (a) has been installed.

4-36
[CONFIDENTIAL]
Maintenance > Maintenance parts replacement procedures

4-37
[CONFIDENTIAL]
Maintenance > Maintenance parts replacement procedures

(4-2)Detaching and reattaching the developer unit


Procedures

1 Detach the inner unit. (Refer P.4-34)

2 Close the toner supply shutter (b) of the developer unit (a).

3 Disconnect the connector (c).

4 Turn down the DLP rail lever (d) to horizontal position.

4-38
[CONFIDENTIAL]
Maintenance > Maintenance parts replacement procedures

5 Release the lock lever (b) at lower side of the developer unit (a) and then pull out the
developer unit (a).

6 Check or replace the developer unit (a) and then reattach the parts in the original
position.

7 Execute the following procedures when replacing the developer unit to the new unit (a).
1 Execute maintenance mode U140 (AC calibration). (Refer P.6-112)

2 Execute maintenance mode U464 (Calibration). (Refer P.6-227)

3 Execute maintenance mode U410 (Auto halftone adjustment). (Refer P.6-206)

When a new development unit is installed, the developer roller protective sheet (a) must be removed.

Shake from side to side five times or more before attaching the developer unit (a).

4-39
[CONFIDENTIAL]
Maintenance > Maintenance parts replacement procedures

5~

4-40
[CONFIDENTIAL]
Maintenance > Maintenance parts replacement procedures

(4-3)Detaching and reattaching the drum unit


Procedures

1 Remove the inner unit. (Refer P.4-34)

2 Remove the developer unit (a). (Refer P.4-38)

3 Pull out the conveying unit (b).

4 Disconnect the connector (d) of the drum unit (c).

5 Remove the screw (e).

4-41
[CONFIDENTIAL]
Maintenance > Maintenance parts replacement procedures

6 Remove the drum unit (a).

7 Check or replace the drum unit (a) and then reattach the parts in the original position.

8 Execute the following procedures when replacing the drum unit to the new unit.
1 Execute maintenance mode U119 (Drum setup). (Refer P.6-101)

2 Execute maintenance mode U140 (AC calibration). (Refer P.6-112)

3 Execute maintenance mode U464 (Calibration). (Refer P.6-227)

4 Execute maintenance mode U412 (Uneven density adjustment). (Refer P.6-216)

5 Execute maintenance mode U464 (Calibration). (Refer P.6-227)

6 Execute maintenance mode U410 (Auto halftone adjustment). (Refer P.6-206)


(4-4)Detaching and reattaching the main charge roller unit
Procedures

1 Detach the inner unit. (Refer P.4-34)

2 Pull out the main charger roller unit (a) by picking and releasing the MC lock lever (b).

3 Check or replace the main charger roller unit (a) and then reattach the parts in the
original position.
When reattaching the main charger roller unit (a), hook the hook (c) firmly by operating the MC lock lever (b) after
inserting the main charger roller unit (a) until click.

4-42