THERMAL THERMAL

COMPONENT RESISTEAN HEAT TRANSFER AREA HEAT LOSS


STRUCTURAL CONDUCTIVITY
FLOOR CHOOSEN MATERIAL THICKNESS CE R AxU
COMPONENTS COEFF. COEFF. (W/m²K) A (m²)
d (m) (W/K)
λh (W/mK) (m²K/W)
Ri - - 0,1300
Plaster 0,02 1,6 0,0125
IsoBrick 0,19 0,3 0,6333 0,353565
Thermal Insulation
WALLS 0,06 0,03 2,0000 77,85 27,525
Material(XPS)
Plaster 0,02 1,6 0,0125 U<0,48
GROUND FLOOR

Re - - 0,0400

WINDOWS Windows (PVC Joinery 6 compartments) 1,5 28,8 43,2


DOORS (Wood Framed Single Glass Door, Filled with Glass Wool) 4 3,52 14,08
Ri - - 0,1300
Plaster 0,02 1,6 0,0125
Reinf. Concrete 0,4 2,2 0,1818 0,420731
BEAMS Thermal Insulation 19,16 8,061
0,06 0,03 2,0000
Material(XPS)
Plaster 0,02 1,6 0,0125 U<0,48
Re - - 0,0400
Ri - - 0,130
Plaster 0,02 1,6 0,013
Reinf. Concrete 0,4 2,2 0,182 0,420731
COLUMNS Thermal Insulation 21,87 9,201
0,06 0,03 2,000
Material(XPS)
Plaster 0,02 1,6 0,013 U<0,48
Re - - 0,040
TOTAL 151,2 102,068