Professional Documents
Culture Documents
Grids Supported by Se Inverters Europe and Apac
Grids Supported by Se Inverters Europe and Apac
3 1
Contents
Technical Note – Grids Supported by SolarEdge Inverters ......................................................................................................................................................... 1
This document provides an overview of common AC grids and their compatibility with SolarEdge inverters. L indicates line (phase)
connection, N indicates Neutral connection.
Earthen systems: SolarEdge inverters are compatible with TN-S/TN-C/TN-C-S and TT networks. The IT network is supported by
SolarEdge inverters above 25K with the following P/N format: SEXXK-XXXXIBXX4.
480V/277V WYE
Three Phase Inverters (L-L)
SE20K-US SE100K
480V
SE30K-US SE100K-US
L-N: 277V SE33.3K SE100K-BR
L-L: 480V
SE40K SE120K
277V
SE66.6K SE120K-US
SE80K
SE80K-US
400V/480V Delta
These grids are supported by SolarEdge inverters above 25K with the following P/N format: SEXXK -XXXXIBXX4.
NOTE:
NOTE
Corner-grounded delta grids are not supported at these voltages.
208V Delta
208V
Single Phase Inverters (L-N) Three Phase Inverters (L-L)
SE3800H-US SE9K-US
SE6000H-US SE14.4K-US
L-L: 208V
SE11400H-US SE17.3K-US
SE43.3K-US
SE50K-US
https://www.solaredge.com/service/support
The error indicated on the product SetApp mobile application LCD screen or on the monitoring platform or by the LEDs, if
there is such an indication.
System configuration information, including the type and number of modules connected and the number and length of strings.