CERTIFICATE OF REFERENCE MATERIAL Nº 2310-103

IPT 135
Silicon, metal (chemical grade)

This reference material was certified by the consensus of a network of expert laboratories using different methodologies, and can be
used for calibration, assessment of precision and trueness and, to demonstrate traceability of results in chemical analysis by classical
and instrumental methods.
This material is a silicon metal (chemical grade) presented in the form of powder, with particle sizes between 63μm and 75μm (sieves
250 mesh and 200 mesh).

Certified Expanded
Properties Uncertainties Unit
Values

Fe 0,125 0,003 %
Al 0,045 0,003 %
C 0,018 0,004 %
Ca 0,011 0,001 %

Ti 113 4 mg/kg
Mn 70 3 mg/kg
P 27 1 mg/kg
Mg 12 1 mg/kg
Cu 8 1 mg/kg
Cr 6 1 mg/kg
Ni 5 1 mg/kg

Informative Expanded
Properties Uncertainties Unit
Values

S Nota/Note (1) 0,002 0,001 %

V Nota/Note (1) 3 1 mg/kg


Pb Nota/Note (2) 2 mg/kg

Lot Number: 01 Valid until : 03/2024


The certified values ​and uncertainties are assured by the validity period, considering that the material is handled and stored in
accordance with the given instructions, except in case of damage or contamination. IPT will monitor periodically the properties of this
reference material during its validity period, and any observed significant change will be reported to the user.

Sao Paulo, 06/2020

Center for Chemistry and Manufactured Goods Center for Chemistry and Manufactured Goods
Metrological References Laboratory Metrological References Laboratory
Patricia Hama Ricardo Rezende Zucchini
CRQ IV 04161340 - RE 08835 CREA 195776 - CRQ IV 04362478 - RE 8272.7
Researcher Laboratory Coordinator

Certificate of Reference Material: 2310-103 r.1 IPT 135 Page 1 of 3


Center for Chemistry and Manufactured Goods
Metrological References Laboratory

Researcher

Uncertainties
The expanded uncertainties of the certified values w ​ ere estimated by the combination, according to ISO Guide 35:2006, of uncertainties
of characterization and homogeneity, obtained experimentally from the interlaboratory certification program data, and where relevant,
with the contributions of stability of material, estimated at IPT. The coverage factor used is approximately 2, providing a confidence
level of 95%.
Traceability
The certified values o​ f the properties of this material were obtained by means of measurements performed at IPT and by a network of
collaborating laboratories, using one or more methods for each property studied. These methods were verified using reference
materials with certified values ​and standards with values traceable to the International System of Units (SI) through NIST and other
qualified producers. The measuring instruments were calibrated with standards traceable to SI through Inmetro and the Brazilian
Calibration Network (RBC).
Mass of samples
The mass of sample required for the proper realization of the determinations depends on the particular methodology, levels of analytes,
and other factors. It is recommended using the masses established in the most current editions of recognized standard methods.
However, to guarantee the validity of all the certified values ​stated herein and their respective uncertainties, should not be employed
samples with masses smaller than 100 mg. This limit was estimated from the sample masses used in the study of homogeneity of this
material.
Handling and storage
Handling: The withdrawal of samples of this material must be accomplished in appropriate environment with clean accessories. Never
return material to the bottle. Keep the material in its original bottle, tightly closed. Storage: This material should be stored in a clean, dry
place, at room temperature. The ideal relative humidity for storage is under 60% RH.
Technical Notes
Note 1. The content of vanadium and sulfur were obtained with relatively large uncertainties.
Note 2.Some participating laboratories also determined lead content by atomic absorption spetrometry and optical emission
spectrometry (ICP-OES).
These results, however, were insufficient to establish the final certified value for these properties, which are being presented only as
informational values.
Additional Information
The raw material for the preparation of this reference material was provided by Ligas de Alumínio S.A. – LIASA.
The preparation and certification of this reference material was coordinated by Celia Omine Iamashita.
This Certificate replaces CRM IPT nº 2044-103

Collaborating Laboratories
AMARGO CORRÊA METAIS S.A. – Breu Branco, PA
C
Áurea Mesquita Machado, Enéas Miranda Sales, Luciano Magno Araújo, Simone Salvador Souza Lemos, Arquimedes Puiatti.

CENTRO DE CARACTERIZAÇÃO E DESENVOLVIMENTO DE MATERIAIS – CCDM/FAI – UFSCar – São Carlos, SP


Rosilene Aparecida Alves, Telma Blanco Matias.

COMPANHIA BRASILEIRA CARBURETO DE CÁLCIO – CBCC (Quansa Química Analítica Ltda) – Santos Dumont, MG
Luiz Cláudio Pereira de Oliveira, Anderson Reis Cardoso de Mello.

COMPANHIA FERROLIGAS MINAS GERAIS – MINASLIGAS – Pirapora, MG


Edgar Salgado de Oliveira, Olímpio Alves da Silva, Marcílio Silva Pereira da Costa.

FUNDAÇÃO CENTRO TECNOLÓGICO DE MINAS GERAIS – CETEC – Belo Horizonte, MG


Isaias Gomes da Silva, Renata Vilela Cecílio Dias,Olguita Geralda Ferreira Rocha.

INSTITUTO DE PESQUISAS ENERGÉTICAS E NUCLEARES - IPEN/CNEN – São Paulo, SP


LABORATÓRIO DE ANÁLISE POR ATIVAÇÃO COM NÊUTRONS - Edson Gonçalves Moreira, Marina Beatriz Agostini Vasconcellos.

INSTITUTO DE PESQUISAS TECNOLÓGICAS DO ESTADO DE SÃO PAULO S.A. – IPT – São Paulo, SP - Divisão de Metalurgia – Laboratório de
Processamento Pirometalúrgico - Erika Emi Oide, Denise Ferreira de Lima Tanaka, Tomoe Oide Tsubaki.

Certificate of Reference Material: 2310-103 r.1 IPT 135 Page 2 of 3


INSTITUTO DE PESQUISAS TECNOLÓGICAS DO ESTADO DE SÃO PAULO S.A. – IPT – São Paulo, SP - Divisão de Química – Laboratório de
Análises Químicas Inorgânicas - Rosana Akiko Hoshino, Elaine de Oliveira Bulhões.

INSTITUTO DE PESQUISAS TECNOLÓGICAS DO ESTADO DE SÃO PAULO S.A. – IPT – São Paulo, SP - Divisão de Química – Laboratório de
Materiais de Referência Inorgânicos - Marcos Antonio Parise, Alcides Carrafa.

ITALMAGNÉSIO NORDESTE S.A. – Várzea da Palma, MG - Mário José Moreira, Anderson Santana da Silva.

LIGAS DE ALUMÍNIO S.A. – LIASA – Pirapora, MG - Glênio Mendonça, Wellington Juarez de Lima, Eugênio Moreira Estrela.

RIMA INDUSTRIAL S.A. – Várzea da Palma, MG - Silvano Crispim, Carlos Eduardo, Clévia Cardoso, Arnaldo Durães, Jamil Alves, Fábio Edno,
Edmilson Medeiros, Leandro Picinato.

Methodologies Employed in the Certification of CRM IPT 135


Al Optical Emission Spectrometry (inductively coupled plasma)
X-Ray Fluorescence Spectrometry
Atomic Absorption Spectrometry
C Direct combustion (infrared)
Ca Atomic Absorption Spectrometry
Optical Emission Spectrometry (inductively coupled plasma)
X-Ray Fluorescence Spectrometry
Cr Atomic Absorption Spectrometry
Optical Emission Spectrometry (inductively coupled plasma)
Cu Atomic Absorption Spectrometry
Optical Emission Spectrometry (inductively coupled plasma)
Fe Atomic Absorption Spectrometry
Optical Emission Spectrometry (inductively coupled plasma)
Instrumental Neutron Activation Analysis
UV-Visible spectrophotometry (5-Sulfosalicylic acid)
X-Ray Fluorescence Spectrometry
Mg Atomic Absorption Spectrometry
Optical Emission Spectrometry (inductively coupled plasma)
Mn Atomic Absorption Spectrometry
Instrumental Neutron Activation Analysis
X-Ray Fluorescence Spectrometry
Optical Emission Spectrometry (inductively coupled plasma)
Ni Optical Emission Spectrometry (inductively coupled plasma)
Atomic Absorption Spectrometry
P Optical Emission Spectrometry (inductively coupled plasma)
UV-Visible spectrophotometry (molybdenum blue)
Pb Optical Emission Spectrometry (inductively coupled plasma)
Atomic Absorption Spectrometry
S Direct combustion (infrared)
Ti X-Ray Fluorescence Spectrometry
Atomic Absorption Spectrometry
UV-Visible spectrophotometry (hydrogen peroxide)
Optical Emission Spectrometry (inductively coupled plasma)
V Optical Emission Spectrometry (inductively coupled plasma)
Atomic Absorption Spectrometry

The latest version of the Certificates of IPT Reference Materials are available for download at: www.ipt.br / nmr.htm
Mod.060811

Certificate of Reference Material: 2310-103 r.1 IPT 135 Page 3 of 3

You might also like