NORTH N

2'W
S65°2
THESE WALLS NOT ATTACHED
T IC
TO BUILDING RAFT MAKKAH
G NE TH
01 02 03 04 05 06 07 08 09 10 11 12 13 A R
B01 B01 B01 B01 B01 B01 B01 B01 B01 B01 B01 B01 B01 M NO
*THE CONSTRUCTION BEFORE THE APPROVAL
NOTES
42000 OF MECHANICAL AND ELECTRICAL DRAWINGS
4200 4200 2100 2100 4200 4200 4200 4200 2100 2100 4200 4200
WILL BE UNDER CONTRACTOR RESPONSIBILTY.
- UNLESS OTHERWISE SHOWN ,ALL DIMENSIONS ARE IN MILLIMETERS
. ALL ELEVATIONS ARE IN METERS.
12600 16800 12600
- REINFORCED STEEL BARS SHALL BE DEFORMED HIGH GRADE STEEL
OF YIELD STRENGTH 4200 K.G/CM2

- CONCRETE MINIMUM ULTIMATE CLYINDER COMPRESSIVE STRENGTHS


AT 28 DAYS SHALL BE :-

FC' = 40 MPA A)FOOTING


TYPICAL B) FLOOR AND ROOF SLABS , STAIRS , BEAMS ANDD GIRDERS
C) WATER TANKS.
CHECK FONT SIZE D) CONCRETE TOPPING OR STRUCTURE SCREED .
A A 08.06.2017 E) COLUMNS AND R.C WALLS.
B01 B01
FC' = 20 MPA A) BLINDING CONCRETE .
B) CATCH BASINS AND SIDEWALKS.
1500
1500
1500 1500 1500 1500
C) SLAB ON GRADE .
4200

4200
Ø 25 @140 .BOTT. Ø 25 @140 .BOTT. Ø 25 @140 .BOTT.
Ø 25 @140 .BOTT. L=8000 Ø 25 @140 .BOTT. L=7000 Ø 25 @140 .BOTT. - ALL PIPES SLEEVES &OTHER BUILDERS WORK REQUIREMENTS FOR
L=9200+1500
L=8000 L=8000 ELECTRO-MECHANICAL WORKS SHALL BE COORDINATED WITH THE APPROVED

6750

5800
L=9500+1500
ELECTRO- MECHANICAL SHOP DRAWINGS BEFORE CONCRETING.

6750

6750

6750
Ø 25 @140 .BOTT. 00

20
20

00
B B
2970

B01 1900mm THK. FOR RAFT. Ø 25 @140 .BOTT. 00


B01

20
20
LEGEND

00
2970
FOUNDATION W/RAFT Ø25@140
2100

2100
E.W. TOP&BOTT. (TYP.) *SLOPE STABALITY CALCULATION FOR THE

3630
@ AT FFL FINISH FLOOR LEVEL

EL.93.425 (295.375) C T.O.W TOP OF WALL


C T.O.RAFT C SOIL UNDER THE RAFT SHOULD BE APPROVED CENTERLINE
GB GRADE BEAM
1500

B01 B01 B BEAM


3500
1500 1500 1500 1500
500 BEFORE THE CONSTRUCTION C, COL COLUMN TYP TYPICAL

4770
2100

2100
Ø 25 @140 .BOTT. Ø 25 @140 .BOTT. Ø 25 @140 .BOTT.

44
20
CANTILEVER BEAM WPM
WATER PROOFING MEMBRANE
L=10500 Ø 25 @140 .BOTT. L=12000 2310 CB

4300
D L=12000 Ø 25 @140 .BOTT. D Dia. DIAMETAR WWF WELDED WIRE FABRIC, WIRE MESH

B01 B01 DWG DRAWING W/ WITH


L=10500+1500 RAFT EF EACH FACE W/O WITHOUT
1800

1800
5550

5550

5550
B01 EL ELEVATION DENOTES MESH IN PLAN

E E EQ EQUAL
--- SECTION MARK NUMBER
B01 B01 EW EACH WAY ------

MIN MINIMUM SECTION DET .PLACED IN


THIS DRAWING NUMBER
2400

2400
NTS NOT TO SCALE
PRECAST DENOTES LEVEL IN PLAN
PC
F F RAFT REF REFERENCE

2000
B02
2000

B01 1500
Ø 25 @150 .BOTT.
1500
1500 1500
1500
Ø 25 @140 .BOTT. B01 KEY PLAN
Ø 25 @140 .BOTT. L=8000 Ø 25 @140 .BOTT. Ø 25 @140 .BOTT. L=10500+1500
L=9000+1500

6700
L=8000 L=7000
­
00
29400

Ø 25 @140 .BOTT.
20

20
4200

4200
00

2970
500

4770
1500 1500 Ø 25 @140 .BOTT.
1500

*COLUMNS AND AXES DRAWING FOR BASEMENT

44
Ø 25 @140 .BOTT.

20
3950

9000+1500 Ø 25 @140 .BOTT. L=7000 2310

L=12000

5950
Ø 25 @140 .BOTT. 8000 20000 SHOULD BE APPROVED BEFORE THE CONSTRUCTION

3950
G L=12000 8000 G B1

B01 B01
1500
1350
1500

1500
500

H H
4770

Ø 25 @140 .BOTT.
20
44

B01 2310 B01


2400
B2
2300
2700

2700
Ø 25 @140 .BOTT.
L=10500+1500

THE CONSTRUCTION
42000

42000
1200

J Ø 25 @140 .BOTT. J
B01 B01
L=10500+1500
MUST BE AFTER THE

10200
8750

TENDER DRAWINGS REFERENCE.


2700

2700
CONFIRMATION FOR THE
3150

1500
Ø 25 @140 .BOTT. DWG. NO. TITLE
Ø 25 @140 .BOTT.
K L=10500+1500 2400
Ø 25 @140 .BOTT. L=10500+1500
K
ELEVATORS SHAFTS B01-S102 FOUNDATION PLAN
1500 1500
L=12000
Ø 25 @140 .BOTT.
B01 Ø 25 @140 .BOTT. 00 Ø 25 @140 .BOTT. B01 DIMENSIONS FROM
20

20
L=8000
1500

1500
00

2970
L=7500
L 20
00 Ø 25 @140 .BOTT. 000
2970
2 L ELEVATORS SUPPLIER
SHOP DRAWINGS REFERENCE .
B01 5500 B01

8750

3630
TITLE
ALL DIMENSIONS, LEVELS, OPENINGS DWG. NO.

AND SLEEVES SHOULD BE COORDINATED


4200

4200
Ø 25 @140 .BOTT. 80
19
5000

19

2900
80

1540
1500

1500
Ø 25 @140 .BOTT.
WITH ARCH. AND MEP. DRAWINGS
1500

Ø 25 @140 .BOTT. 1500 Ø 25 @140 .BOTT.


L=8000 L=10500+1500
2900

L=9000+1500 Ø 25 @140 .BOTT. 1500

Ø 25 @140 .BOTT. L=6000 Ø 25 @140 .BOTT. Achitectural Sructural Electrical Mechanical Technical Office Manager
M L=9000 L=6000 M
B01 B01
2400

2400
8450
CLIENT

KINGDOM OF SAUDI ARABIA


N N MINISTRY OF INTERIOR
B01 B01
Ø 25 @140 .BOTT.
5550
5550
1800

1800
1500

5550

1550 SECURITY PLANNING AND DEVELOPMENT AGENCY


3500 1500 1500 L=10500+1500
Ø 25 @140 .BOTT. Ø 25 @140 .BOTT.
P L=10500 1000 Ø 25 @140 .BOTT. L=12000 P CONSULTANT
B01 B01 PROGER S.P.A
L=12000 Tel: 011 4647319

2100
Fax: 011 4654230
P.O. Box : 18775 Post Code: 11425
Riyadh, Al Ma'ather Street
12600

Q Q
4200

CONTRACTOR
B01 B01 Bin Dubais Company

2100
1500
1500
Trading & Contracting
1500 1500 Ø 25 @140 .BOTT.
R Ø 25 @140 .BOTT.
1500
L=8000 R CONTRACTOR CONSULTANT

L=8000 Ø 25 @140 .BOTT.


B01 Ø 25 @140 .BOTT. Ø 25 @140 .BOTT. L=7000
B01
Ø 25 @140 .BOTT.
L=10500+1500 L=8000 L=9200+1500
6750

6750

6750

6750

6750
4200

4200
PROJECT NAME
APPROVALS

CLIENT

S S
B01 B01
TITLE

RAFT FOUNDATION BOTTOM(X-DIR )


4200 4200 2100 2100 4200 4200 4200 4200 2100 2100 4200 4200 REINFORCEMENT DETAILS
CONSULTANT
42000

B01 B01 B01 B01 B01 B01 B01 B01 B01 B01 B01 B01 B01
01 02 03 04 05 06 07 08 09 10 11 12 13 1 SHOP DRAWING ISSUED FOR APPROVAL 06 / 06 / 2017 HAITHAM Ali Mohammad Shaaban Mohammad Shaaban

A DESIGN DRAWING ISSUED FOR APPROVAL 4 / 05 / 2017 HAITHAM Ali Mohammad Shaaban Mohammad Shaaban

0 SHOP DRAWING ISSUED FOR APPROVAL 19 / 04 / 2017 HAITHAM Ali Mohammad Shaaban Mohammad Shaaban
CONTRACTOR

3 RAFT FOUNDATION BOTTOM(X-DIR) REINFORCEMENT DETAILS REV. DESCRIPTION DATE DRAWN BY CHECKED BY APPROVED BY

0 5 10 SCALE TRANSMITTAL NO.

1:100 1 : 100
CDHC-DWG-125-MB01-ST-0003

SCALE 1:100 METERS DATE OF THE DRAWING DWG. NO.


1-1-2017 CDHC-DWG-SD-125-MB01-ST-2004-1