Solenoid interlocks

AZM 161 Technical data Contact variants


Standards: IEC/EN 60947-5-1 Power to unlock
BG-GS-ET-19 2 NO / 4 NC (12/12)
Enclosure: glass-fibre reinforced
A1 51 71 63
thermoplastic, self-extinguishing
Actuator and A2 52 72 64
locking bolt: stainless steel 1.4301
13 14
Protection class: IP 67 to EN 60529 21 22
41 42
Contact material: silver
13 14 21 22 41 42 51 52 63 64 71 72 A1 A2
Contact type: change-over contact
with double break, type Zb,
with galvanically separated 2 NO / 4 NC
contact bridges
A1 51 63

6 Switching system: A IEC 60947-5-1


slow action, A2 52 64
NC contacts with positive break
31 32 13 14
6
8

72 Termination: screw terminals 41 42 21 22


90
18

6 or cage clamps A1 A2
13 14 21 22 31 32 41 42 51 52 63 64
Cable section: max. 1.5 mm2
6

(incl. conductor ferrules)


Cable entry: AZM 161-24, -33: 3 x M16 x 1.5
30

AZM 161-12/12: 4 x M16 x 1.5 3 NO / 3 NC


28 Uimp: 4 kV
130 A1 51 63
8

Ui: 250 V
Ithe: 10 A A2 52 64
• Thermoplastic enclosure Utilisation category: AC-15, DC-13
33 34 13 14
• 6 contacts Ie/Ue: 4 A / 230 VAC 41 42 21 22

• Manual release, emergency exit 2.5 A / 24 VDC A1 A2


13 14 21 22 33 34 41 42 51 52 63 64
or emergency release Max. fuse rating: 6 A gL/gG D-fuse
• Long life Positive break travel: AZM 161-24, -33: 8.8 mm
• Double insulated X AZM 161-12/12: 9.5 mm
• High holding force 2000 N Positive break force: 10 N for each Power to lock
• 30 N latching force NC contact fitted 2 NO / 4 NC (12/12)
• Large wiring compartment Us: 24 VAC/DC
A1 51 71 63
• Power to unlock/power to lock principle 110/230 VAC, 50/60Hz
• Screw terminals or cage clamps Magnet: 100% ED A2 52 72 64
• 3 or 4 cable entries M16 x 1.5 Power consumption: max. 10 W
13 14
• Actuating play 5.5 mm in Ambient temperature: – 25 °C … + 60 ºC 21 22
41 42
direction of actuation Mechanical life: > 1 million operations
13 14 21 22 41 42 51 52 63 64 71 72 A1 A2
• Individual coding available on request Fmax: 2000 N
• AS-Interface Safety at Work available, Latching force: 30 N
see chapter 5 2 NO / 4 NC
A1 51 63

A2 52 64

31 32 13 14
41 42 21 22

A1 A2
13 14 21 22 31 32 41 42 51 52 63 64

Approvals

H C/D
Ordering details Note Note
AZM 161 ➀ -➁ rk➂ ➃ -➄ -➅ 24 VDC
10 mA

No. Replace Description A1 A2


RD GN - 13 14 21 22 31 32 41 42 51 52 63 64

➀ SK Screw terminals 33 34
CC Cage clamp
ST Connector M 12 x 1
➁ 12/12 2NO/4NC
24 2NO/4NC Emergency exit (left) LED version:
33 3NO/3NC • For cases of danger Ordering suffix G,
➂ Power to unlock • Actuation from within the hazardous area limited terminating space 0.75 mm2
a Power to lock • Ordering suffix T Protected against incorrect polarity and
➃ Manual release Emergency release (middle) voltage spikes.
T or N see notice on the right • For cases of danger
➄ Without LED • Mounting only outside the guarded area Actuators must be ordered separately.
G With LED (only for -24, -33) • Ordering suffix N
➅ 024 Us 24 VAC/DC Manual release (right)
110/230 Us 110 / 230 VAC • For manual release using M5 triangular key,
available as accessory
• For maintenance, setting-up, etc.
1-20
Solenoid interlocks

Contact variants System components System components


Power to lock 8 ø 5,5 R min. 15 R min. 15
3 NO / 3 NC 0 40 0
28
26

16
A1

8
51 63

5,5
R min. 18 R min. 18

5,3
40 0 0
A2 56
52 64 16

41,2
11
33 34 13 14
41 42 21 22

32,7
A1 A2
13 14 21 22 33 34 41 42 51 52 63 64 2 27
2 27
Straight actuator AZM 161-B1 Straight actuator AZM 161-B1F
Connector
2 NO / 4 NC (12/12) 102
56 R min. 15 52 20
0 6,5
A1 51 71 63

23

22
14

5
5
30
A2 52 72 64 R min. 18
ø 5,5 0

6,5
13 14

178
116
21 22 5

215
41 42

175
32,7

13 14 21 22 41 42 51 52 63 64 71 72 A1 A2

59,5
50
2 27
12-3
100 157
Straight actuator AZM 161-B1E Actuator AZM 161-B30
1 234 1 234

R min. 95
1 NO / 3 NC
A1
39

51 63
11

R min. 95
A2 52 64

31 32 13 14
41 42 21 22
16

A1 A2
ø 5,5

13 14 21 22 31 32 41 42 51 52 63 64
40

Flexible actuator AZM 161-B6 Mounting set MS AZM 161


1 234 1 234
R min. 95

2 NO / 2 NC 52
R min. 95
A1 51 63
16

A2
6

52 64

33 34 13 14
41 42 21 22
40
16

A1 A2
56
13 14 21 22 33 34 41 42 51 52 63 64

AZM 161-B6-2177 with centering guide Slot sealing plug AZM 161

1 234 1 234

Note Ordering details Ordering details


The contacts 51-52 and 63-64 are actuated Straight actuator AZM 161-B1 Straight actuator AZM 161-B1F
when the solenoid A1-A2 is energised or Straight actuator AZM 161-B1E Actuator with or without
de-energised. Flexible actuator AZM 161-B6 emergency handle AZM 161-B30
Contact 51-52 must be integrated in the safety with centering guide AZM 161-B6-2177 A detailed product description
circuit. can be found in the „Safety door
Circuit diagrams show de-energised condition handle system STS“ brochure.
with actuator inserted (0 in switch travel diagram).
Mounting set MS AZM 161
Interlocks with power to lock principle may only Slot sealing plug AZM 161 1145379
be used in special cases after a thorough eval- Tamperproof screws with
uation of the accident risk, since the guarding unidirectional slots (without drawing)
device can immediately be opened on failure of M5 x 12 1135338
the electrical power supply or when the main M5 x 16 1135339
switch is opened. M5 x 20 1135340
(Quantity 2 pcs)

1-21