DATA SHEET ELSMT01D-D
ELSMT01
SPECIFICATION FOR AC INDUCTION MOTORS PAGE 5 OF 6

UP TO AND INCLUDING 500 HP (370 kW) MAY 2019

ITEM TAG NO.: Hazardous Classified Motors JOB NO.: AFE5000008522 REV. DATE: 04-15-21
DATA PROVIDED BY: PURCHASER SUPPLIER u SUPPLIER IF NOT BY PURCHASER
ACCESSORIES (4.6) (CONTINUED):
BEARING TEMPERATURE DETECTORS (4.6.3): REQUIRED NOT REQUIRED
TWO PER BEARING ONE PER BEARING OTHER:
3 WIRE PLATINUM, 100 OHMS @ 0˚C OTHER:
GROUND ONE COMMON LEAD
OTHER:
VIBRATION DETECTORS (4.6.4) REQUIRED NOT REQUIRED
INSTALLED PROVISIONS ONLY
SENSOR TYPE: SENSOR MFG.
QTY / D.E. BEARING: LOCATION (H,V,A):
QTY / O.D.E. BEARING: LOCATION (H,V,A):
OTHER:
OTHER:
INSPECTION & TESTING (4.7):
X TESTS PER IEEE 841 OTHER:
ADDITIONAL TESTING AS DESCRIBED IN OTHER REQUIREMENTS: REQUIRED NOT REQUIRED
WITNESSED NOT WITNESSED
CERTIFIED TEST REPORTS: REQUIRED NOT REQUIRED
SHIPPING:
X SUPPLIERS STD PREPARATION OTHER:
PRE-SHIPMENT SHOP INSPECTION: REQUIRED NOT REQUIRED
DOCUMENTATION (4.8):
PERFORMANCE SUBMITTALS PER TABLE 2 (4.8.3): REQUIRED NOT REQUIRED
ELECTRONIC DOCUMENT FORMAT: X DWG X PDF OTHER:
SUPPLIER TO PROVIDE: 1 REPRODUCIBLE PLUS
COPIES OF ALL DOCUMENTS PLUS
COPIES OF OPERATING MANUALS
OTHER REQUIREMENTS:
Notes:
1. Motor enclosure shall be as per hazardous area classification plan.
2. Motor Mounting shall be as per Mechanical requirement.
3. Motor material construction shall be as IEEE 841.