Spectrophotometre Request

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

IDEAL SERVICE INDUSTRY

ADRESSE: BP N°60 TBELBOU 6032 GABES, TUNISIE-


TEL:+21628998291, FAX:75266499, MF: 1328568L
EMAIL: ideals ervice.industry@gmail.com

Subject: Flame atomic abso rptio n spectrophoto meter


double beams

Technical specification of the supplies:

Type: Flame atomic absorption spectrophotometer with double beams


optical system: double beam
wavelength: 180-900nm
wavelength selection: automatic
optical system: fiber optic
monochromator: specify number of lines/mm
detector: solid state detector SDD with two zones (sample + reference)
background correction: by D2 deuterium lamp
turret: minimum 4 lamps with automatic lamp selection and alignment by the software
spectral bandwidth: automatic selection /2nm maximum
dispe rsion: 3nm/mm maximum
nebulizer: high sensitivity in materials resistant to corrosive solutions.

burner: - 5cm and 10cm titanium head


- automatic recognition of the burner
- automatic ignition of the flame with safety

automatic adjustme nts :


automatic adjustment of wavelength, slit width of lamp current and preheating of lamp position

calibration curve and analysis:


repetition of analyses, display of the average value and automatic elimination of deviating values
and calculation of final concentrations.

gas control:
-gas management system (pressure and flow rate) allowing to keep constant the ratio between a ir
and gas (air/C2H2 and N2O/C2H2), ensuring the stability of the flame properties (T°, oxidizing or
reducing)
- gas safety system with indication in case of problem

powe r supply:
220V-50Hz (IT neutral mode); in case the spectrophotometer works with TT or TN neutral mode, a
transformer for connection to the IT mode of the factory is required.

require d pe rformances:
verification of the analysis results by standard solutions such as iron, cadmium...

accessories:
-cathode lamps:
* two cadmium (Cd) cathode lamps
* one iron (Fe) cathode lamp
* one cathode lamp of magnesium (Mg)
* one aluminum (Al) cathode lamp
IDEAL SERVICE INDUSTRY
ADRESSE: BP N°60 TBELBOU 6032 GABES, TUNISIE-
TEL:+21628998291, FAX:75266499, MF: 1328568L
EMAIL: ideals ervice.industry@gmail.com

* a calcium (Ca) cathode lamp


* a sodium (Na) cathode lamp
with the standard solutions of concentration 1000 mg/l corresponding to each requested element,
- an oil- free air compressor, complete and silent, with a tank volume of 4 to 24 liters and delivered
with air and humidity filters compatible with the SAA spectrophotometer and with the necessary
connection accessories.
- a suction hood with a motor made of material resistant to corrosive vapors
- an integrated microcomputer for the control of the SAA-F with the necessary software for the
control and the piloting of the spectrometer and its various accessories
- software with license: with the possibility to store and export the result files to other software such
as a spreadsheet and the possibility to process the data after analysis
- acetylene pressure regulator
- nitrous oxide pressure regulator
- an AVR (automatic voltage regulator) stabilizer
Type: single phase
capacity: 3kVA minimum
input: 140-260 VAC
output: 220+/-3VAC
efficiency: >98%
input/output voltage display
protection against high temperature overheating, short circuit, overvoltage/undervoltage