The New Standard in Trace Detection: Desktop Explosives & Drugs Trace Detector

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

The new standard in trace detection

QS-B220
Desktop Explosives & Drugs
Trace Detector

Implant Sciences’ Technology Better Performance


Product Highlights Combining the latest in Ion Mobility Built for better resolving power and faster
Spectrometry (IMS) analysis technology clear-down, the QS-B220 delivers superior
• Simultaneously detects with unmatched ease-of-use and an detection performance with low false
industry-leading low maintenance design, alarm rates. Implant Sciences’ patented
explosives & drugs in seconds the QS-B220 defines the new standard inCal automatic internal calibration
in trace detection. The system performs system uses no consumables and does not
• inCalTM automatic calibration simultaneous detection of a wide variety require any action by the system operator,
of explosives and drugs, and delivers so screeners can focus on security.
results in seconds. Results are displayed
• Intuitive touch-screen controls on the screen and can be printed on the Lower Total Cost of Ownership
integrated thermal printer, an external
Operational costs are extremely low
• Non-radioactive ion source USB printer, or on a network printer.
with the QS-B220. Common maintenance
procedures are fully automated - just push a
• Push-button maintenance Easy-to-Use button on the system’s touch-screen menu
The QS-B220’s large high-resolution system. Long life dopants and calibrants
touch-screen, with over 40% more last for years without replacement.
• Rapid clear-down
viewing area than other ETD systems, Routine service consists of cleaning
makes operating the system simple. All using common supplies and desiccant
• Integrated thermal printer functions are accessed through dynamic replacement as required.
touch buttons that present screeners
only the options necessary to get the job No radioactive material is used in the
• Remote Diagnostics
done. Authorized users can also access QS-B220, so there are no associated
spectrogram analysis, administrative, and certification, licensing, inspection, testing,
• Low total cost of ownership diagnostics tools. transportation, or decommissioning costs.

Totalpost Mailing & Mechanisation Ltd


1 Skelgillside t +44 (0) 845 4900360
Alston f +44 (0) 845 4900361
Cumbria e sales@totalpost.com
CA9 3TR
United Kingdom www.totalpost.com
The new standard in trace detection
Specifications
Detector Type: Substances Detected:
Ion Mobility Spectrometer (IMS) with photonic non-radioactive Explosives: Military, Commercial, and Homemade Explosives (HMEs)
ionization (U.S. Patent #7,576,320), pulsed ultraviolet ion source including: Ammonium Nitrate, ANFO, Black Powder, C-4, Detasheet,
(U.S. Patent #7,820,979), and inCal automated chemical calibration Detonating Cord, Dinitrotoluene, DMNB, Dynamite, EGDN, HMTD,
system (U.S. Patent #7,709,788) HMX, Nitroglycerin (NG), o-MNT, p-MNT, Peroxides, PETN, RDX,
Semtex, Smokeless Powder, Tetryl, Triacetone Triperoxide (TATP),
Sampling Rate: Trinitrotoluene (TNT), Urea Nitrate, and others
Minimum of 180 samples per hour when no alarm occurs
Drugs: Cocaine, Heroin, Ketamine, L-amphetamine, LSD, MDA,
Automatic clear-down requires no user intervention
MDMA, Methamphetamine, Morphine, PCP, Spice, THC, and others
Typical clear-down time is less than 10 seconds
Not a complete listing of substances detectable by the QS-B220.
Warm-up Time: Actual substances configured in library may vary depending on
30 minutes maximum system configuration and regulatory requirements. Substances can
be added through user-expandable detection library.
Sample Acquisition:
Particulate collection via wiping Power:
Input voltage: 100-240 VAC, 47-63 Hz
Calibration: Power consumption: 350 watts peak (225 watts typical)
inCal automatic internal calibration system
Operating Environment:
Alarm Method: Temperature: -10˚C to 55˚C (14˚F to 131˚F)
Configurable visual and audible alarms Altitude: Up to 4,572 m (15,000 ft)
Substance identification by name (depending on configuration) Humidity: 0 to 95% non-condensing

Consumable Materials: Dimensions (WxHxD):


Low-cost molecular sieve drying agent (desiccant) 42.5 cm x 36.9 cm x 40.4 cm (16.8 in x 14.5 in x 15.9 in) without printer
High-durability sample traps 42.5 cm x 39.9 cm x 40.4 cm (16.8 in x 15.7 in x 15.9 in) with printer
Additional preventative maintenance supplies as required
Weight:
Expandability and Connectivity: 14.6 kg (32.1 lb) without printer, 15.7 kg (34.7 lb) with printer
4 USB 2.0 ports for accessories such as an optional keyboard, printer,
and mouse. RJ-45 ethernet network port supports control station Data Display:
monitoring, remote control, and remote diagnostics. VGA port. 31.8 cm (12.5 in) high-resolution color touch-screen

The inCal automatic internal calibration The easy-to-use touch-screen enables The QS-B220 rapidly and simultaneously
system and push-button diagnostics security officers to focus on the job, detects both explosives and drugs.
lower the total cost of ownership. not on running the equipment. No switching modes required.

Totalpost Mailing & Mechanisation Ltd


t +44 (0) 845 4900360 Queens Award for

1 Skelgillside
Enterprise in
International Trade

f +44 (0) 845 4900361 2013

Alston
e sales@totalpost.com
Cumbria
CA9 3TR
www.totalpost.com
United Kingdom

You might also like