NRL EXPANSION PROJECT

MANUFACTURER’S NAME MANUFACTURING QUALITY PLAN PROJECT


AND ADDRESS
QAP NO R/QCD/07 PACKAGE SUPPLY OF VFD PANELS
ITEM: VFD Panel
DANFOSS INDUSTRIES REV.NO 00 PO / CONTRACT LOA NO:EMH:306:2021-22 DT:18-02-2022
PRIVATE LIMITED,
Plot A-19/2 SIPCOT, NO.
ORAGADAM VILLAGE, DATE 20/06/2022 NUMALIGARH REFINERY LIMITED, ASSAM
KANCHIPURAM - 602105 RATINGS 18.5KW & 22KW CLIENT
PAGE 1/ 6 CUSTOMER Enginemates Heat Transfer Private Limited

1) Dimensions
Major Meas. 100% As per App. Drawings App. drawings QC Record P R W -
INGRESS
2) Visual inspection
Major Visual 100% As per App. Drawings App. drawings QC Record P R - PROTECTION
W
TYPE TEST
Panel enclosure 3) Check for paint App. drawings / CERTIFICATE TO
1 Meas. &
shade, paint thickness Major 100% As per App. Drawings Min 60 Micron paint QC Record P R W - BE SUBMITTED
Visual
thickness. FOR REVIEW
4) Panel identification DURING FINAL
Manufacture Test INSPECTION
Major Visual 100% As per App. Drawings reports / Danfoss QC Record P R W -
Quality standards.

1)Verification of
Components for make,
As per App.
type, rating & layout Major Visual 100% As per App. Drawings R W -
components as per
Drawings P
bill of material
2) Check for mounting
Assembled drive Correctness As per App. As per App.
2
panel Major Visual 100% As per App. Drawings
Drawings Drawings P R W -

3) Wiring check Electrica As per App.


Major
l
100% As per App. Drawings
Drawings
P R W -

4) Check for marking & As per App.


tagging
Major Visual 100% As per App. Drawings
Drawings
P R W -

FINAL INSPECTION

COMPONENT TYPE QUANTUM


SL. REFERENCE FORMAT OF AGENCY
& CHARACTERISTIC OF OF CHECK ACCEPTANCE REMARKS
NO CLASS
S DOCUMENT NORMS RECORD TPIA MPMC/
OPERATIONS CHECK M T/EIL S M T OWNER
1. 2. 3. 4. 5. 6. 7. 8. 9. D* ** 10. 11.

LEGEND: DOC. NO R/QCD/07 REV 00

** M: MAIN SUPPLIER S: SUB SUPPLIER, T: TPIA;TPIA:


TOYO/TPIA;MPMC/OWNER. P: PERFORM W: WITNESS AND
SUB-SUPPLIER (YTD) MAIN-SUPPLIER FOR
V: VERIFICATION. AS APPROPRIATE, R: REVIEWED
(DANFOSS)
SIGNATURE USE REVIEWED BY APPROVED APPROVAL SEAL
BY
Classified as Business Issue Status – A
NRL EXPANSION PROJECT
MANUFACTURER’S NAME MANUFACTURING QUALITY PLAN PROJECT
AND ADDRESS
QAP NO R/QCD/07 PACKAGE SUPPLY OF VFD PANELS
ITEM: VFD Panel
DANFOSS INDUSTRIES REV.NO 00 PO / CONTRACT LOA NO:EMH:306:2021-22 DT:18-02-2022
PRIVATE LIMITED,
Plot A-19/2 SIPCOT, NO.
ORAGADAM VILLAGE, DATE 20/06/2022 NUMALIGARH REFINERY LIMITED, ASSAM
KANCHIPURAM - 602105 RATINGS 18.5KW & 22KW CLIENT
PAGE 2/ 6 CUSTOMER Enginemates Heat Transfer Private Limited

COMPONENT TYPE QUANTUM


SL. REFERENCE FORMAT OF AGENCY
& OF OF CHECK ACCEPTANCE REMARKS
NO CHARACTERISTICS CLASS
M T/EIL DOCUMENT NORMS RECORD TPIA MPMC/
OPERATIONS CHECK S M T OWNER
1. 2. 3. 4. 5. 6. 7. 8. 9. D* ** 10. 11.
Check control 1) Visual inspection
wiring / terminal 100%
3 Major Visual As per App. Drawings As per App. Drawings QC Record P R W -
arrangement &
ferruling
Check door
100%
4 interlock & defeat 1) Visual inspection Major Visual As per App. Drawings As per App. Drawings QC Record P R W -
interlock.
1) Dimension
Earth bus 100%
5 2) Visual inspection Major Visual As per App. Drawings As per App. Drawings QC Record P R W -
dimensions,
Overall visual 1) Visual inspection
check
for aesthetics,
Measure
verticality
ments
6 of panels and Major 100% As per App. Drawings As per App. Drawings QC Record P R W -
Visual
alignment
checks
between two
transport
sections

LEGEND: DOC. NO R/QCD/07 REV 00

** M: MAIN SUPPLIER S: SUB SUPPLIER, T: TPIA;TPIA:


TOYO/TPIA;MPMC/OWNER. P: PERFORM W: WITNESS AND
SUB-SUPPLIER (YTD) MAIN-SUPPLIER FOR
V: VERIFICATION. AS APPROPRIATE, R: REVIEWED
(DANFOSS)
SIGNATURE USE REVIEWED BY APPROVED APPROVAL SEAL
BY
Classified as Business Issue Status – A
NRL EXPANSION PROJECT
MANUFACTURER’S NAME MANUFACTURING QUALITY PLAN PROJECT
AND ADDRESS
QAP NO R/QCD/07 PACKAGE SUPPLY OF VFD PANELS
ITEM: VFD Panel
DANFOSS INDUSTRIES REV.NO 00 PO / CONTRACT LOA NO:EMH:306:2021-22 DT:18-02-2022
PRIVATE LIMITED,
Plot A-19/2 SIPCOT, NO.
ORAGADAM VILLAGE, DATE 20/06/2022 NUMALIGARH REFINERY LIMITED, ASSAM
KANCHIPURAM - 602105 RATINGS 18.5KW & 22KW CLIENT
PAGE 3/ 6 CUSTOMER Enginemates Heat Transfer Private Limited
QUANTUM
SL COMPONENT AGENCY
TYPE OF OF CHECK REFERENCE ACCEPTANCE FORMAT OF
. & CHARACTERISTICS CLASS REMARKS
NO CHECK T/ DOCUMENT NORMS RECORD MPMC/
OPERATIONS M S M T TPIA
EIL OWNER
1. 2. 3. 4. 5. 6. 7. 8. 9. D* ** 10. 11.
CT /PT fixing & 1) Visual inspection
Measurements As per App. As per App.
7 mounting Major 100% QC Record P R W -
Visual checks Drawings Drawings
arrangement
Check shrouding 1) Visual inspection
Measurements As per App. As per App.
8 of accessible live Major 100% QC Record P R W -
Visual checks Drawings Drawings
parts
1) Insulation test As per App. As per App.
Major Electrical NA P W W W
Drawings Drawings
2) Light load and functional As per App. As per App.
Major Electrical NA P W W W
test on 2.2KW motor Drawings Drawings
3) Load duty test As per App. As per App.
Major Electrical NA P W W W
Drawings Drawings
4) Memory check of fault As per App. As per App.
Major Electrical QC Record NA P W W W
history Drawings Drawings
5) Check auxiliary devices,
9 Routine Tests 100%
control devices, protective As per App. As per App.
Major Electrical NA P W W W
devices, check on control and Drawings Drawings
functional requirements
6) Measurement of speed at Major Electrical As per App. As per App. NA
P
different frequencies Drawings Drawings W W W
7) HV Test Major Electrical As per App. As per App.
QC Record NA P W W W
Drawings Drawings
8) Steady state performance Major Electrical As per App. As per App.
QC Record NA P W W W
test Drawings Drawings

COMPONENT TYPE OF QUANTUM REFERENCE ACCEPTANCE FORMAT OF


CHARACTERISTICS CLASS AGENCY REMARKS
& CHECK OF CHECK DOCUMENT NORMS RECORD

LEGEND: DOC. NO R/QCD/07 REV 00

** M: MAIN SUPPLIER S: SUB SUPPLIER, T: TPIA;TPIA:


TOYO/TPIA;MPMC/OWNER. P: PERFORM W: WITNESS AND
SUB-SUPPLIER (YTD) MAIN-SUPPLIER FOR
V: VERIFICATION. AS APPROPRIATE, R: REVIEWED
(DANFOSS)
SIGNATURE USE REVIEWED BY APPROVED APPROVAL SEAL
BY
Classified as Business Issue Status – A
NRL EXPANSION PROJECT
MANUFACTURER’S NAME MANUFACTURING QUALITY PLAN PROJECT
AND ADDRESS
QAP NO R/QCD/07 PACKAGE SUPPLY OF VFD PANELS
ITEM: VFD Panel
DANFOSS INDUSTRIES REV.NO 00 PO / CONTRACT LOA NO:EMH:306:2021-22 DT:18-02-2022
PRIVATE LIMITED,
Plot A-19/2 SIPCOT, NO.
ORAGADAM VILLAGE, DATE 20/06/2022 NUMALIGARH REFINERY LIMITED, ASSAM
KANCHIPURAM - 602105 RATINGS 18.5KW & 22KW CLIENT
PAGE 4/ 6 CUSTOMER Enginemates Heat Transfer Private Limited
SL
T/ MPMC/
. OPERATIONS M S M T TPIA
EIL OWNER
NO
1. 2. 3. 4. 5. 6. 7. 8. 9. D* ** 10. 11.

QUANTUM
SL COMPONENT AGENCY
TYPE OF OF CHECK REFERENCE ACCEPTANCE FORMAT OF
. & CHARACTERISTICS CLASS REMARKS
NO CHECK T/ DOCUMENT NORMS RECORD MPMC/
OPERATIONS M S M T TPIA
EIL OWNER
1. 2. 3. 4. 5. 6. 7. 8. 9. D* ** 10. 11.
10 VFD Acceptance 1)Full load current Vs Speed Major Electrical 100 ONE As per App. As per App.
NA P W W W
Test % SAM Drawings Drawings
2) Efficiency Major Electrical PLE/ As per App. As per App.
RAN NA P W W W
Drawings Drawings
3) Measurement of Torque Vs Major Electrical DO As per App. As per App.
M NA P W W W
Speed Drawings Drawings
BASI QC Record
4) Power Factor As per App. As per App.
Major Electrical S NA P W W W
Drawings Drawings
5) Voltage Division As per App. As per App.
Major Electrical NA P W W W
Drawings Drawings
6) Line side current/Voltage Major Electrical As per App. As per App. NA
P
harmonic content Drawings Drawings W W W
7) Harmonic content at the Major Electrical As per App. As per App.
QC Record NA P W W W
output current/voltage Drawings Drawings
8) Dynamic performance test Major Electrical As per App. As per App.
QC Record NA P W W W
Drawings Drawings
9) Current limit and current Major Electrical As per App. As per App.
QC Record NA P W W W
loop Drawings Drawings
10) Speed loop Major Electrical As per App. As per App. QC Record NA P W W W
Drawings Drawings

LEGEND: DOC. NO R/QCD/07 REV 00

** M: MAIN SUPPLIER S: SUB SUPPLIER, T: TPIA;TPIA:


TOYO/TPIA;MPMC/OWNER. P: PERFORM W: WITNESS AND
SUB-SUPPLIER (YTD) MAIN-SUPPLIER FOR
V: VERIFICATION. AS APPROPRIATE, R: REVIEWED
(DANFOSS)
SIGNATURE USE REVIEWED BY APPROVED APPROVAL SEAL
BY
Classified as Business Issue Status – A
NRL EXPANSION PROJECT
MANUFACTURER’S NAME MANUFACTURING QUALITY PLAN PROJECT
AND ADDRESS
QAP NO R/QCD/07 PACKAGE SUPPLY OF VFD PANELS
ITEM: VFD Panel
DANFOSS INDUSTRIES REV.NO 00 PO / CONTRACT LOA NO:EMH:306:2021-22 DT:18-02-2022
PRIVATE LIMITED,
Plot A-19/2 SIPCOT, NO.
ORAGADAM VILLAGE, DATE 20/06/2022 NUMALIGARH REFINERY LIMITED, ASSAM
KANCHIPURAM - 602105 RATINGS 18.5KW & 22KW CLIENT
PAGE 5/ 6 CUSTOMER Enginemates Heat Transfer Private Limited
11) Automatic Restart Major Electrical As per App. As per App.
QC Record NA P W W W
Drawings Drawings
12) Noise test Major Electrical As per App. As per App.
QC Record NA P W W W
Drawings Drawings

1)Temperature rise test As per App. As per App.


Major Electrical 1 SAMPLE NA P W R -
Drawings Drawings
11 VFD Type Test FOR EACH QC Record
2) Degree of protection As per App. As per App.
Major Visual check RATING NA P W R -
Drawings Drawings
QUANTUM
SL COMPONENT AGENCY
TYPE OF OF CHECK REFERENCE ACCEPTANCE FORMAT OF
. & CHARACTERISTICS CLASS REMARKS
NO CHECK T/ DOCUMENT NORMS RECORD MPMC/
OPERATIONS M S M T TPIA
EIL OWNER
1. 2. 3. 4. 5. 6. 7. 8. 9. D* ** 10. 11.
1)Temperature rise test As per App. As per App.
Major Electrical 1 SAMPLE NA P W R -
Drawings Drawings
11 VFD Type Test FOR EACH QC Record
2) Degree of protection As per App. As per App.
Major Visual check RATING NA P W R -
Drawings Drawings

1)Temperature rise test As per App. As per App.


Major Electrical 1 SAMPLE NA P W R -
Drawings Drawings
11 VFD Type Test FOR EACH QC Record
2) Degree of protection As per App. As per App.
Major Visual check RATING NA P W R -
Drawings Drawings

1)Temperature rise test As per App. As per App.


Major Electrical 1 SAMPLE NA P W R R
Drawings Drawings
11 VFD Type Test FOR EACH QC Record
2) Degree of protection As per App. As per App.
Major Visual check RATING NA P W R R
Drawings Drawings
1)Visual and DFT check As per App. As per App.
12 Painting Major Meas. & Visual 100% QC Record NA P H W W
Drawings Drawings

LEGEND: DOC. NO R/QCD/07 REV 00

** M: MAIN SUPPLIER S: SUB SUPPLIER, T: TPIA;TPIA:


TOYO/TPIA;MPMC/OWNER. P: PERFORM W: WITNESS AND
SUB-SUPPLIER (YTD) MAIN-SUPPLIER FOR
V: VERIFICATION. AS APPROPRIATE, R: REVIEWED
(DANFOSS)
SIGNATURE USE REVIEWED BY APPROVED APPROVAL SEAL
BY
Classified as Business Issue Status – A
NRL EXPANSION PROJECT
MANUFACTURER’S NAME MANUFACTURING QUALITY PLAN PROJECT
AND ADDRESS
QAP NO R/QCD/07 PACKAGE SUPPLY OF VFD PANELS
ITEM: VFD Panel
DANFOSS INDUSTRIES REV.NO 00 PO / CONTRACT LOA NO:EMH:306:2021-22 DT:18-02-2022
PRIVATE LIMITED,
Plot A-19/2 SIPCOT, NO.
ORAGADAM VILLAGE, DATE 20/06/2022 NUMALIGARH REFINERY LIMITED, ASSAM
KANCHIPURAM - 602105 RATINGS 18.5KW & 22KW CLIENT
PAGE 6/ 6 CUSTOMER Enginemates Heat Transfer Private Limited
1)Temperature rise test 1 SAMPLE
COMBINED As per App. As per App. AT MOTOR
13 Major Electrical FOR EACH QC Record NA P W W W
TEST Drawings Drawings VENDOR WORKS
RATING

QUANTUM
SL COMPONENT AGENCY
TYPE OF OF CHECK REFERENCE ACCEPTANCE FORMAT OF
. & CHARACTERISTICS CLASS REMARKS
NO CHECK T/ DOCUMENT NORMS RECORD MPMC/
OPERATIONS M S M T TPIA
EIL OWNER
1. 2. 3. 4. 5. 6. 7. 8. 9. D* ** 10. 11.

LEGEND: DOC. NO R/QCD/07 REV 00

** M: MAIN SUPPLIER S: SUB SUPPLIER, T: TPIA;TPIA:


TOYO/TPIA;MPMC/OWNER. P: PERFORM W: WITNESS AND
SUB-SUPPLIER (YTD) MAIN-SUPPLIER FOR
V: VERIFICATION. AS APPROPRIATE, R: REVIEWED
(DANFOSS)
SIGNATURE USE REVIEWED BY APPROVED APPROVAL SEAL
BY
Classified as Business Issue Status – A