00. ABOUT US 3
01. BARE CONDUCTOR 7
02. AERIAL BUNDLED CABLES LOW VOLTAGE 76
03. AERIAL BUNDLED CABLES MEDIUM VOLTAGE 100
04. POWER CABLE LOW VOLTAGE 108
05. POWER CABLE MEDIUM VOLTAGE 134
06. POWER CABLE HIGH VOLTAGE 204
07. CONCENTRIC CABLE LOW VOLTAGE 205
08. CONCENTRIC CABLE MEDIUM VOLTAGE 208
09. ELECTRIC WIRE 222
10. RUBBER CABLE 241
11. CONTROL CABLE 244
12. SOLAR CABLE 251
www.eescable.com 2
PRODUCTS
ABOUT US
POWER CABLE MV
ELECTRIC WIRE
ABC CABLE MV
www.eescable.com 3
WORKSHOP
ABOUT US
www.eescable.com 4
CUSTOMERS
ABOUT US
www.eescable.com 5
PACK&DELIVERY
ABOUT US
DESC CONTENT
HERE
www.eescable.com 6
ASTM B231
All Aluminum Stranded Conductor (AAC)
Max DC
Stranding Nominal
Overall Linear Resistance
Total Area and Wire Breaking at 20°C
Code Name Diameter Diameter Mass Load
AWG or MCM mm2 mm mm kg/km daN Ω/km
Peachbell 6 13.29 7/1.554 4.67 37 249 2.1692
Rose 4 21.16 7/1.961 5.89 58 396 1.3624
Iris 2 33.61 7/2.474 7.42 93 597 0.8577
Pansy 1 42.39 7/2.776 8.33 117 732 0.6801
Poppy 1/0 53.48 7/3.119 9.36 147 873 0.5390
Aster 2/0 67.42 7/3.503 10.51 186 1100 0.4276
Phlox 3/0 85.03 7/3.932 11.80 234 1347 0.3390
Oxlip 4/0 107.23 7/4.417 13.26 293 1698 0.2688
Valerian 250 126.71 19/2.913 14.57 349 2062 0.2275
Sneezewort 250 126.71 7/4.80 14.40 349 2007 0.2275
www.eescable.com 7
ASTM B231
All Aluminum Stranded Conductor (AAC)
Stranding Max DC
Nominal
Resistance
Total and Wire Overall Linear Breaking
Code Name at 20°C
Area Diameter Diameter Mass Load
AWG or MCM mm2 mm mm kg/km daN Ω/km
www.eescable.com 8
BS 215
All Aluminum Stranded Conductor (AAC)
Nomin
No./Dia. Linea Max. DC Final
al Section Overall Coefficient
of r Resistance of Calculated Modulus
Cross al Diamet of Linear
Stranding Weig Conductor at Breaking Load of
Code Name Sectio Area er Expansion
Wires ht 20°C Elasticity
n
mm2 No./mm mm2 mm kg/km Ω/km daN hbar /℃
Wasp 100 7/4.39 106.00 13.17 290 0.2702 1600 5900 23×10-6
Beetle 100 19/2.67 106.00 13.40 293 0.2704 1742 5600 23×10-6
Bee 125 7/4.90 132.00 14.70 361 0.2169 1944 5900 23×10-6
Cricket 150 7/5.36 157.90 16.10 432 0.1818 2385 5900 23×10-6
Hornet 150 19/3.25 157.60 16.25 434 0.1825 2570 5600 23×10-6
Caterpillar 175 19/3.53 186.00 17.70 512 0.1547 2863 5600 23×10-6
Chafer 200 19/3.78 213.20 18.90 587 0.1349 3240 5600 23×10-6
Spider 225 19/3.99 236.90 20.00 652 0.1211 3601 5600 23×10-6
Cockroach 250 19/4.22 265.70 21.10 731 0.1083 4040 5600 23×10-6
Butterfly 300 19/4.65 322.70 23.25 888 0.0892 4875 5600 23×10-6
Moth 350 19/5.00 373.20 25.00 1027 0.0771 5637 5600 23×10-6
Drone 350 37/3.58 373.30 25.10 1029 0.0774 5745 5600 23×10-6
Locust 400 19/5.36 428.50 26.80 1179 0.0671 6473 5600 23×10-6
Centipede 400 37/3.78 415.20 26.46 1145 0.0694 6310 5600 23×10-6
Maybug 450 37/4.09 486.90 28.60 1342 0.0593 7401 5600 23×10-6
Scorpion 500 37/4.27 529.50 29.90 1460 0.0544 7998 5600 23×10-6
Cicada 600 37/4.65 628.60 32.60 1733 0.0459 9495 5600 23×10-6
Tarantula 750 37/5.23 794.60 36.60 2191 0.0363 12010 5600 23×10-6
www.eescable.com 9
IEC 61089
All Aluminum Stranded Conductor (AAC)
Diameter
Max. DC
No.ofStranding Rated Resistance
Cross Section Wires Conductor Linear Mass
Wires Strength at 20°C
k
mm2 - mm mm kg/km Ω/km
N
10 7 1.35 4.05 27.4 1.95 2.8633
16 7 1.71 5.12 43.8 3.04 1.7896
25 7 2.13 6.40 68.4 4.50 1.1453
40 7 2.7 8.09 109.4 6.80 0.7158
63 7 3.39 10.20 172.3 10.39 0.4545
100 19 2.59 12.90 274.8 17.00 0.2877
125 19 2.89 14.50 343.6 21.25 0.2302
160 19 3.27 16.40 439.8 26.40 0.1798
200 19 3.66 18.30 549.7 32.00 0.1439
250 19 4.09 20.50 687.1 40.00 0.1151
315 37 3.29 23.00 867.9 51.97 0.0916
400 37 3.71 26.00 1102.0 64.00 0.0721
www.eescable.com 10
DIN 48201
All Aluminum Stranded Conductor (AAC)
DIN 48201
Overall Max. DC
Code Calculated Cross No./Dia. of Stranding Linear Mass Calculated
Diameter Resistance at
Number Section Wire Breaking Load
20°C
mm² mm² No./mm mm kg/km daN Ω/km
www.eescable.com 11
9.5MM ALUMINUM
WIRE ROD
Aluminum Rod
www.eescable.com 12
ASTM B399
All Aluminum Alloy 6201-T81
Conductors ( AAAC )
Conductor MaximumDC
1350 GradeEquivalent Nominal resistance
TotalArea (Approx) Stranding NominalWeight RatedStrength
diameter at 20oC
Code
Name AWGor AW
mm2 Gor No/ mm mm kg/km kN Ω/km
MCM MCM
www.eescable.com 13
ASTM B399
All Aluminum Alloy 6201-T81
Conductors ( AAAC )
Conductor MaximumDC
Overall resistance
TotalArea Equivalent CopperArea Stranding Weight RatedStrength
diameter at 20oC
AWG
AWGor
mm2 or mm2 No/ mm mm kg/km kN Ω/km
MCM
MCM
www.eescable.com 14
AS 1531
All Aluminum Alloy 6201-T81
Conductors ( AAAC )
Maximum DC
Equivalent
Resistance at
AreaActual Copper Area Stranding OverallDiameter Weight RatedStrength
20oC
Code Name
mm2 mm2 No / mm mm kg/km kN Ω/km
www.eescable.com 15
BS 3242
All Aluminum Alloy 6201-T81
Conductors ( AAAC )
Nominal Maximum DC
Equivalent
Aluminum RatedStrength Resistance at
Copper Area Stranding OverallDiameter TotalArea Weight
Area 20oC
CodeName
mm2 mm2 No / mm mm mm2 kg/km kN Ω/km
www.eescable.com 16
DIN 48201
All Aluminum Alloy 6201-T81
Conductors ( AAAC )
www.eescable.com 17
NFC 34125
All Aluminum Alloy 6201-T81
Conductors ( AAAC )
Equivalen Maximum DC
t Copper Stranding OverallDiameter Total Area Weight RatedStrength Resistance at
CodeName
Area 20oC
mm2 No / mm mm mm2 kg/km daN Ω/km
www.eescable.com 18
IEC 61089
All Aluminum Alloy 6201-T81
Conductors ( AAAC )
Equivalent Maximum DC
AreaActual Copper Stranding OverallDiameter Weight RatedStrength
Resistance at
CodeName
Area 20oC
mm2 mm2 No / mm mm kg/km kN Ω/km
www.eescable.com 19
SS 4240814
All Aluminum Alloy 6201-T81
Conductors ( AAAC )
Equivalent
Area Maximum DC
Copper Stranding OverallDiameter Weight RatedStrength Resistance at
Nominal Actual 20oC
Area
www.eescable.com 20
CABO DE ALUMÍNIO LIGA
CAL 1120 AS 1531
All Aluminium Alloy Conductor 1120(AAAC 1120)
Descrição:
OCAL 1120 é um condutor de encordoamento concêntrico, composto de uma ou
mais coroas de fios de alumínio liga1120.
Aplicação
Em circuitos aéreos onde seja necessário resistência mecânica maior que do
cabo CA (entre 40 e 50%) ou menor peso e melhor característica de resistência à
corrosão e que o cabo CAA. Com uma condutividade de 59% IACS, a liga de
alumínio 1120 substitui com grande vantagem a liga 6201 em relação a
resistência elétrica.
Nota: neste catálogo procurou-se incluir, além das seções normalizadas pela norma australiana
AS 1531, diversas outras seções já estudadas por empresas brasileiras de projetos de linhas de
transmissão e seções intermediárias em intervalos de aproximadamente 50kcmil entre seções.
www.eescable.com 21
CABO DE ALUMÍNIO LIGA
CAL 1120 AS 1531
All Aluminium Alloy Conductor 1120(AAAC 1120)
Características Técnicas
Resistência Resistência
Formação Nº Diâmetro Elétrica Elétrica
SeçãoTransversal Massa Cargade Capacidadede
de Fiosx Nominal do Máxima(CC) a Máxima (CA/
Diâmetro N° Condutor Nominal Ruptura Corrente (*)
Denominação 20°C 60Hz) a50°C
kcmil mm² xmm mm kg/km kN A
ohm/km ohm/km
FLUORINE 97,7 49,48 7 x3,00 9,00 135 11,8 0,5998 0,6702 206
HELIUM 152,6 77,30 7 x3,75 11,25 211 17,6 0,3839 0,4291 274
HYDROGEN 219,7 111,30 7 x4,50 13,50 304 24,3 0,2666 0,2982 347
IODINE 244,8 124,00 7 x4,75 14,25 339 27,1 0,2393 0,2677 372
KRYPTON 311,1 157,60 19 x3,25 16,25 433 37,4 0,1892 0,2119 435
- 350,0 177,61 19 x3,45 17,25 488 42,18 0,1679 0,1882 470
LUTETIUM 360,8 182,80 19 x3,50 17,50 502 41,7 0,1631 0,1828 478
NEON 414,1 209,80 19 x3,75 18,80 577 47,8 0,1421 0,1595 523
- 450,0 228,14 19 x3,91 19,55 627 52,01 0,1307 0,1468 552
NITROGEN 516,2 261,54 37 x3,00 21,00 720 62,2 0,1143 0,1286 603
- 550,0 278,50 19 x4,32 21,60 765, 63,5 0,1071 0,1206 628
NOBELIUM 605,8 307,00 37 x3,25 22,80 845 72,8 0,0973 0,1098 669
OXYGEN 664,5 336,70 19 x4,75 23,80 925 73,6 0,0886 0,1002 709
www.eescable.com 22
CABO DE ALUMÍNIO LIGA
CAL 1120 AS 1531
All Aluminium Alloy Conductor 1120(AAAC 1120)
Características Técnicas
Resistência Resistência
Formação Nº Diâmetro Elétrica Elétrica
SeçãoTransversal Massa Cargade Capacidadede
de Fiosx Nominal do Máxima(CC) a Máxima (CA/
Diâmetro N° Condutor Nominal Ruptura Corrente (*)
Denominação 20°C 60Hz) a50°C
kcmil mm² xmm mm kg/km kN A
ohm/km ohm/km
SELENIUM 998,7 506,10 61 x3,25 29,30 1400 114 0,0592 0,0679 919
- 1005,0 509,16 61 x3,26 29,34 1405 114,5 0,0588 0,0675 923
- 1030,0 521,73 61 x3,30 29,70 1440 117,4 0,0574 0,0659 937
- 1051,0 532,33 37 x4,28 29,96 1466 121,37 0,0561 0,0645 950
- 1100,0 557,50 37 x4,38 30,66 1535 127,11 0,0536 0,0618 958
- 1152,0 583,54 61 x3,49 31,41 1610 131,3 0,0513 0,0593 986
- 1156,2 585,80 37 x4,49 31,43 1613 133,57 0,051 0,0590 989
SILICON 1158,3 586,90 61 x3,50 31,50 1620 127 0,051 0,0590 990
- 1198,3 607,18 61 x3,56 32,04 1676 131,15 0,0493 0,0572 1012
- 1253,0 634,77 61 x3,64 32,76 1752 137 0,0472 0,0549 1040
- 1301,4 659,40 61 x3,71 33,39 1820 142,4 0,0454 0,0530 1071
SULFUR 1329,6 673,72 61 x3,75 33,80 1860 145,5 0,0445 0,0520 1081
- 1358,0 688,17 61 x3,79 34,11 1899 148,64 0,0435 0,0510 1096
- 1401,5 710,14 61 x3,85 34,65 1960 153,4 0,0422 0,0496 1117
- 1453,0 736,20 61 x3,92 35,28 2032 159 0,0407 0,0480 1143
- 1505,3 762,70 61 x3,99 35,91 2104 164,74 0,0393 0,0465 1169
- 1551,0 785,80 61 x4,05 36,45 2169 169,7 0,0381 0,0452 1191
- 1605,0 813,20 61 x4,12 37,08 2244 175,7 0,0368 0,0439 1217
- 1652,0 837,09 61 x4,18 37,62 2310 180,8 0,0358 0,0428 1239
- 1700,0 861,30 61 x4,24 38,16 2377 186,04 0,0348 0,0418 1261
- 1748,2 885,84 61 x4,30 38,70 2445 191,34 0,0338 0,0407 1283
- 1789,0 906,50 61 x4,35 39,15 2502 195,8 0,033 0,0399 1302
- 1797,4 910,70 61 x4,36 39,24 2513 196,71 0,0329 0,0398 1305
- 1855,5 940,20 61 x4,43 39,87 2595 203,1 0,0319 0,0388 1330
- 1906,2 965,85 61 x4,49 40,41 2666 208,62 0,031 0,0378 1353
- 1949,0 987,48 61 x4,54 40,86 2725 204,4 0,0303 0,0371 1371
- 2000,7 1013,76 61 x4,60 41,40 2798 209,84 0,0295 0,0363 1394
* Para cálculo de capacidade de corrente foram considerados os seguintes fatores: temperatura ambiente 40 °C, temperatura do condutor 75 °C,
velocidade do vento 2,2km/h, emissividade 0,5 e sem contribuição do sol.
www.eescable.com 23
AS 1531
All Aluminium Alloy Conductor
1120(AAAC 1120)
Equivalent Maximum DC
AreaActual Copper Area Stranding OverallDiameter Weight RatedStrength Resistance at 20oC
Code Name
mm2 mm2 No / mm mm kg/km kN Ω/km
www.eescable.com 24
DIN 48206
Aluminum Alloy Conductor Steel
Reinforced (AACSR)
www.eescable.com 25
ASTM B711
Aluminum Alloy Conductor Steel
Reinforced (AACSR)
www.eescable.com 26
IEC 61089
Aluminum Alloy Conductor Steel
Reinforced (AACSR)
A2 Conductors A3 Conductors
Max. DC
Code No./Di No./Di No./Di No./Di Resistanc
Overall Appro Rated Strength Overall Appro Rated Strength
Numb a. of a. of a. of a. of e at 20°C
er Diamet x. Diamet x.
Al Steel A2/S1A A2/S3A Al Steel A3/S1A A3/S3A
er Weigh er Weigh
Alloy Wire Alloy Wire
t t
mm² No./mm No./mm mm kg/km kN kN No./mm No./mm mm kg/km kN kN Ω/km
16 6/1.98 1/1.98 5.93 74.4 9.02 9.88 6/1.99 1/1.99 5.96 75.1 9.67 10.53 1.7934
25 6/2.47 1/2.47 7.41 116.2 13.96 15.25 6/2.48 1/2.48 7.45 117.3 14.96 16.27 1.1478
40 6/3.13 1/3.13 9.38 185.9 22.02 24.17 6/3.14 1/3.14 9.42 187.7 23.63 25.79 0.7174
63 6/3.92 1/3.92 11.80 292.8 34.68 37.58 6/3.84 1/3.94 11.80 295.6 36.48 39.41 0.4555
100 18/2.85 1/2.85 14.30 366.4 41.24 42.97 18/2.87 1/2.87 14.30 369.9 45.12 46.86 0.2880
125 18/3.19 1/3.19 16.00 458.0 51.23 53.47 18/3.21 1/3.21 16.00 462.3 56.08 58.34 0.2304
125 26/2.65 7/2.06 16.80 579.9 69.86 76.42 26/2.07 7/2.07 16.90 585.4 74.88 81.50 0.2310
160 18/3.61 1/3.61 18.00 586.2 65.58 68.03 18/3.63 1/3.63 18.10 591.8 69.92 72.40 0.1800
160 26/3.00 7/2.34 19.00 742.3 88.52 96.61 26/3.02 7/2.35 19.10 749.4 94.94 103.11 0.1805
200 18/4.04 1/4.04 20.20 732.8 81.97 85.04 18/4.05 1/4.05 20.30 739.8 87.40 90.50 0.1440
200 26/3.36 7/2.61 21.30 927.9 110.64 120.77 26/3.37 7/2.62 21.40 936.7 118.67 128.89 0.1444
250 22/4.08 7/2.27 23.10 1013.5 117.09 124.72 22/4.10 7/2.28 23.20 1023.2 124.02 131.72 0.1154
250 26/3.75 7/2.92 23.80 1159.6 138.31 150.96 26/3.77 7/2.93 23.90 1170.9 145.43 158.21 0.1155
315 45/3.2 7/2.14 25.80 1196.5 136.28 143.30 45/3.22 7/2.15 25.70 1207.9 148.56 155.64 0.0917
315 26/4.21 7/3.28 26.70 1461.4 171.90 188.44 26/4.23 7/3.29 26.80 1475.9 180.86 197.55 0.0917
400 45/3.61 7/2.41 28.90 1519.4 172.10 180.36 45/3.63 7/2.42 29.00 1533.9 183.03 191.71 0.0722
400 54/3.29 7/3.29 29.70 1738.3 201.46 218.17 54/3.31 7/3.31 29.80 1754.9 217.32 234.19 0.0723
450 45/3.83 7/2.55 30.60 1709.3 193.61 203.28 45/3.85 7/2.56 30.80 1725.6 205.91 215.67 0.0642
450 54/3.49 7/3.49 31.50 1955.6 226.64 245.44 54/3.51 7/3.51 31.60 1974.2 239.26 255.52 0.0643
500 45/4.04 7/2.69 32.30 1899.3 215.12 225.86 45/4.05 7/2.70 32.40 1917.3 228.79 239.63 0.0578
500 54/3.68 7/3.68 33.20 2172.9 251.82 269.73 54/3.70 7/3.70 33.30 2193.6 265.84 283.91 0.0578
560 45/4.27 7/2.85 34.20 2127.2 240.93 252.97 45/4.29 7/2.86 34.30 2147.4 256.24 268.39 0.0516
560 54/3.9 19/2.34 35.10 2420.9 283.21 305.25 54/3.92 19/2.35 35.30 2444.0 298.92 321.17 0.0516
630 72/3.58 7/2.39 35.80 2248.0 249.62 258.08 72/3.60 7/2.40 36.00 2269.4 266.64 275.18 0.0459
630 54/4.13 19/2.48 37.20 2723.5 318.61 343.40 54/4.15 19/2.49 37.40 2749.5 336.28 361.32 0.0459
710 72/3.8 7/2.53 38.00 2533.4 281.32 290,85 72/3.82 7/2.55 38.20 2557.6 300.50 310.12 0.0407
710 54/4.39 19/2.63 39.50 3069.4 359.06 387.01 54/4.41 19/2.65 39.70 3098.6 378.98 407.20 0.0407
800 72/4.04 7/2.69 40.40 2854.6 316.98 327.72 72/4.05 7/2.70 40.50 2881.8 338.59 349.43 0.0361
800 84/3.74 7/3.74 41.10 3145.1 356.03 374.44 84/3.75 7/3.75 41.30 3175.1 378.01 396.60 0.0362
900 72/4.28 7/2.85 42.80 3211.4 356.60 368.69 72/4.30 7/2.87 43.00 3242.0 380.91 393.11 0.0321
900 84/3.96 7/3.96 43.60 3538.3 400.53 421.25 84/3.98 7/3.98 43.80 3572.0 425.26 446.17 0.0322
1000 84/4.18 19/2.61 45.90 3916.8 446.37 471.67 84/4.20 19/2.52 46.20 3954.1 473.86 499.40 0.0289
1120 84/4.42 19/2.65 48.60 4386.8 499.93 528.27 84/4.44 19/2.66 48.90 4428.6 530.72 559.33 0.0258
www.eescable.com 27
ASTM B524
Aluminium Conductor
Aluminium Alloy Reinforced(ACAR)
S TRANDING 7 2 / 1 9
3000 1520 4.613 50.74 3343 878 4221 270.00 0.01966 1958
2750 1393 4.415 48.57 3063 808 3871 247.00 0.02147 1866
2500 1267 4.209 46.30 2784 731 3515 225.00 0.02362 1769
2493 1263 4.204 46.24 2785 731 3515 224.00 0.02367 1767
2250 1140 3.993 43.92 2506 658 3164 202.00 0.02624 1666
2000 1013 3.764 41.40 2206 579 2785 182.00 0.02924 1562
S TRANDING 6 3 / 2 8
3000 1520 4.613 50.74 2926 1290 4216 287.00 0.01995 1948
2750 1393 4.415 48.57 2680 1180 3860 263.00 0.02178 1856
2500 1267 4.209 46.30 2436 1080 3516 239.00 0.02397 1759
2250 1140 3.993 43.92 2193 970 3163 215.00 0.02663 1657
2000 1013 3.764 41.40 1930 853 2783 193.00 0.02968 1553
S TRANDING 5 4 / 3 7
3000 1520 4.613 50.74 2508 1710 4218 308.00 0.02025 1938
2750 1393 4.415 48.57 2297 1570 3867 282.00 0.02211 1846
2500 1267 4.209 46.30 2088 1420 3508 257.00 0.02432 1750
2493 1263 4.204 46.24 2089 1423 3512 256.00 0.02438 1748
2250 1140 3.993 43.92 1879 1280 3159 231.00 0.02703 1647
2000 1013 3.764 41.40 1654 1130 2784 207.00 0.03012 1544
S TRANDING 5 4 / 7
2000 1013 4.600 41.40 2470 318 2788 169.00 0.02882 1571
1900 963 4.483 40.35 2346 303 2649 160.00 0.03034 1524
1800 912 4.364 39.28 2223 287 2510 152.00 0.03202 1476
1750 887 4.303 38.73 2161 288 2439 148.00 0.03293 1452
1700 861 4.239 38.15 2098 271 2369 143.00 0.03393 1426
1600 811 4.115 37.04 1976 255 2231 135.00 0.03601 1376
1500 760 3.983 35.85 1852 239 2090 127.00 0.03843 1323
1400 709 3.848 34.63 1729 223 1952 118.00 0.04118 1268
1361.5 690 3.795 34.16 1685 217 1902 117.00 0.04234 1247
1300 659 3.708 33.37 1605 207 1812 112.00 0.04435 1212
1227 647 3.675 33.08 1580 204 1784 110.00 0.04515 1199
1250 633 3.635 32.72 1542 199 1741 107.00 0.04615 1182
1200 608 3.564 32.08 1482 191 1673 104.00 0.04800 1154
1100 557 3.411 30.70 1358 176 1534 95.90 0.05241 1093
1000 507 3.251 29.26 1234 159 1393 87.90 0.05769 1029
Note :
+ Ampacity calculated on : 25°C Ambient Temperature, 75°C conductor temperature, 0.61m/s wind speed, 900 W/m2 Intensity of Solar Radiation, 0.6 Solar Radiation
Absorption Coefficient, 0.5 Emissivity Coefficient.
www.eescable.com 28
ASTM B524
Aluminium Conductor
Aluminium Alloy Reinforced(ACAR)
S TRANDING 4 8 / 1 3
2338 1185 4.973 44.76 2597 700 3297 211.00 0.02526 1703
2000 1013 4.600 41.40 2196 592 2788 181.00 0.02923 1562
1900 963 4.483 40.35 2086 562 2648 172.00 0.03078 1516
1800 912 4.364 39.28 1976 532 2508 163.00 0.03248 1468
1750 887 4.303 38.73 1921 516 2437 158.00 0.03341 1443
1703 863 4.244 38.20 1873 505 2378 154.00 0.03434 1420
1700 861 4.239 38.15 1865 502 2367 153.00 0.03442 1418
1600 811 4.115 37.04 1757 473 2230 145.00 0.03653 1368
1500 760 3.983 35.85 1646 443 2089 135.00 0.03899 1315
1400 709 3.848 34.63 1536 414 1950 126.00 0.04177 1261
1300 659 3.708 33.37 1427 384 1811 119.00 0.04499 1205
1250 633 3.635 32.72 1371 369 1740 114.00 0.04681 1175
1200 608 3.564 32.08 1318 355 1673 110.00 0.04869 1147
1100 557 3.411 30.70 1207 326 1533 102.00 0.05316 1086
1000 507 3.251 29.26 1097 296 1393 94.10 0.05852 1023
S TRANDING 4 2 / 1 9
2338 1185 4.973 44.76 2273 1022 3295 229.00 0.02563 1693
2000 1013 4.600 41.40 1921 865 2786 196.00 0.02966 1553
1933 979 4.522 40.70 1861 837 2698 189.00 0.03069 1522
1900 963 4.483 40.35 1825 821 2646 186.00 0.03123 1507
1800 912 4.364 39.28 1729 778 2507 176.00 0.03295 1459
1798 911 4.361 39.25 1731 779 2509 176.00 0.03300 1458
1750 887 4.303 38.73 1681 757 2438 171.00 0.03389 1435
1700 861 4.239 38.15 1632 735 2367 166.00 0.03493 1409
1600 811 4.115 37.04 1537 692 2229 157.00 0.03706 1360
1534.4 777 4.028 36.25 1477 664 2141 150.00 0.03868 1325
1500 760 3.983 35.85 1440 649 2089 147.00 0.03956 1307
1400 709 3.848 34.63 1344 605 1950 137.00 0.04238 1253
1300 659 3.708 33.37 1249 562 1811 129.00 0.04564 1197
1277 647 3.675 33.08 1229 553 1782 126.00 0.04647 1184
1250 633 3.635 32.72 1199 540 1739 124.00 0.04750 1168
1200 608 3.564 32.08 1153 519 1672 119.00 0.04941 1140
1100 557 3.411 30.70 1056 475 1531 110.00 0.05394 1079
1000 507 3.251 29.26 960 431 1391 102.00 0.05938 1017
Note :
+ Ampacity calculated on : 25°C Ambient Temperature, 75°C conductor temperature, 0.61m/s wind speed, 900 W/m2 Intensity of Solar Radiation, 0.6 Solar Radiation
Absorption Coefficient, 0.5 Emissivity Coefficient.
www.eescable.com 29
ASTM B524
Aluminium Conductor
Aluminium Alloy Reinforced(ACAR)
S TRANDING 3 3 / 2 8
2000 1013 4.600 41.40 1509 1274 2783 212.00 0.03032 1540
1900 963 4.483 40.35 1434 1210 2644 201.00 0.03193 1493
1800 912 4.364 39.28 1358 1147 2505 191.00 0.03369 1446
1750 887 4.303 38.73 1321 1115 2436 186.00 0.03465 1422
1700 861 4.239 38.15 1282 1082 2364 180.00 0.03571 1397
1600 811 4.115 37.04 1208 1020 2228 160.00 0.03789 1348
1500 760 3.983 35.85 1131 955 2086 159.00 0.04045 1295
1400 709 3.848 34.63 1056 892 1948 148.00 0.04333 1241
1300 659 3.708 33.37 981 828 1809 139.00 0.04667 1186
1250 633 3.635 32.72 942 796 1738 133.00 0.04856 1157
1200 608 3.564 32.08 906 765 1671 128.00 0.05052 1129
1100 557 3.411 30.70 830 701 1531 119.00 0.05515 1069
1000 507 3.251 29.26 754 657 1391 110.00 0.06071 1007
S TRANDING 3 3 / 4
1300 659 4.760 33.32 1616 195 1811 109.00 0.04432 1211
1250 633 4.669 32.68 1555 187 1742 105.00 0.04607 1183
1200 608 4.575 32.03 1493 180 1673 101.00 0.04798 1154
1100 557 4.379 30.65 1367 165 1532 92.30 0.05237 1092
1000 507 4.176 29.23 1244 150 1394 83.90 0.05759 1030
950 481 4.069 28.48 1181 142 1323 79.70 0.06066 997
900 456 3.962 27.73 1120 135 1255 75.50 0.06398 964
850 431 3.851 26.96 1058 127 1185 71.30 0.06772 930
800 405 3.734 26.14 994 120 1114 68.20 0.07203 895
750 380 3.617 25.32 933 112 1045 64.00 0.07676 860
700 355 3.493 24.45 870 105 975 60.70 0.08231 823
650 329 3.366 23.56 808 97.4 905 56.30 0.08864 785
600 304 3.233 22.63 746 89.9 835 52.40 0.09608 746
550 279 3.096 21.67 684 82.6 767 48.10 0.10477 706
500 253 2.951 20.66 621 74.9 696 44.40 0.11532 665
Note :
+ Ampacity calculated on : 25°C Ambient Temperature, 75°C conductor temperature, 0.61m/s wind speed, 900 W/m2 Intensity of Solar Radiation, 0.6 Solar Radiation
Absorption Coefficient, 0.5 Emissivity Coefficient.
www.eescable.com 30
ASTM B524
Aluminium Conductor
Aluminium Alloy Reinforced(ACAR)
S TRANDING 3 0 / 7
1300 659 4.760 33.32 1469 341 1810 118.00 0.04485 1206
1250 633 4.669 32.68 1413 328 1741 114.00 0.04661 1177
1200 608 4.575 32.03 1357 315 1672 109.00 0.04855 1148
1198 607 4.570 31.99 1358 315 1673 109.00 0.04866 1146
1172 594 4.521 31.65 1329 308 1637 107.00 0.04972 1131
1109 562 4.397 30.78 1257 292 1549 101.00 0.05256 1093
1100 557 4.379 30.65 1244 289 1533 100.00 0.05299 1087
1024.5 519 4.227 29.59 1161 269 1431 93.20 0.05687 1040
1000 507 4.176 29.23 1131 262 1393 91.00 0.05827 1025
950 481 4.069 28.48 1074 249 1323 86.40 0.06137 992
900 456 3.962 27.73 1018 236 1254 81.90 0.06473 959
853.7 433 3.858 27.01 968 225 1192 77.60 0.06827 928
850 431 3.851 26.96 962 223 1185 77.30 0.06852 926
800 405 3.734 26.14 904 210 1114 73.80 0.07288 891
750 380 3.617 25.32 848 197 1045 69.20 0.07767 856
700 355 3.493 24.45 791 184 975 65.50 0.08329 819
650 329 3.366 23.56 735 171 906 60.80 0.08969 781
600 304 3.233 22.63 678 158 836 56.80 0.09722 742
550 279 3.096 21.67 622 144 766 52.10 0.10601 703
500 253 2.951 20.66 565 131 696 48.00 0.11669 661
S TRANDING 2 4 / 1 3
1300 659 4.760 33.32 1176 633 1809 131.00 0.04594 1193
1250 633 4.669 32.68 1131 610 1741 126.00 0.04775 1165
1200 608 4.575 32.03 1086 585 1671 121.00 0.04973 1136
1198 607 4.570 31.99 1086 585 1672 120.00 0.04984 1135
1109 562 4.397 30.78 1006 542 1547 111.00 0.05384 1082
1100 557 4.379 30.65 995 536 1531 111.00 0.05428 1076
1080.6 548 4.341 30.39 980 528 1508 109.00 0.05523 1065
1024.5 519 4.227 29.59 929 500 1430 103.00 0.05825 1030
1000 507 4.176 29.23 905 488 1393 101.00 0.05968 1014
950 481 4.069 28.48 858 463 1321 95.40 0.06286 982
927.2 470 4.021 28.15 841 453 1294 93.20 0.06437 967
900 456 3.962 27.73 814 439 1253 90.50 0.06631 949
853.7 433 3.858 27.01 774 417 1191 85.80 0.06993 918
850 431 3.851 26.96 769 415 1184 85.40 0.07018 916
800 405 3.734 26.14 723 390 1113 81.20 0.07465 881
750 380 3.617 25.32 679 366 1045 76.20 0.07956 847
700 355 3.493 24.45 632 341 973 71.80 0.08531 810
650 329 3.366 23.56 588 317 905 66.60 0.09187 773
600 304 3.233 22.63 542 292 834 62.80 0.09958 735
550 279 3.096 21.67 497 268 765 57.60 0.10859 695
500 253 2.951 20.66 452 244 696 52.90 0.11952 654
Note :
+ Ampacity calculated on : 25°C Ambient Temperature, 75°C conductor temperature, 0.61m/s wind speed, 900 W/m2 Intensity of Solar Radiation, 0.6 Solar Radiation
Absorption Coefficient, 0.5 Emissivity Coefficient.
www.eescable.com 31
ASTM B524
Aluminium Conductor
Aluminium Alloy Reinforced(ACAR)
S TRANDING 1 8 / 1 9
1300 659 4.760 33.32 882 926 1808 146.00 0.04708 1181
1250 633 4.669 32.68 848 890 1738 140.00 0.04893 1154
1200 608 4.575 32.03 814 855 1669 135.00 0.05096 1125
1172 594 4.521 31.65 797 837 1634 131.00 0.05219 1108
1100 557 4.379 30.65 746 784 1530 123.00 0.05563 1065
1080.6 548 4.341 30.39 735 771 1506 121.00 0.05661 1054
1000 507 4.176 29.23 678 713 1391 112.00 0.06117 1004
950 481 4.069 28.48 644 677 1321 106.00 0.06443 972
900 456 3.962 27.73 611 642 1253 101.00 0.06795 940
850 431 3.851 26.96 577 606 1183 95.30 0.07193 907
800 405 3.734 26.14 543 570 1113 90.30 0.07651 872
750 380 3.617 25.32 509 534 1043 84.70 0.08154 838
739.8 375 3.592 25.14 503 528 1031 83.50 0.08268 830
700 355 3.493 24.45 475 498 973 79.50 0.08743 802
650 329 3.366 23.56 440 463 903 73.80 0.09415 765
649.5 329 3.365 23.56 442 464 905 73.80 0.09421 765
600 304 3.233 22.63 406 427 833 70.10 0.10206 727
550 279 3.096 21.67 373 392 765 64.30 0.11129 688
500 253 2.951 20.66 339 356 695 58.80 0.12249 647
S TRANDING 1 5 / 4
600 304 4.513 22.57 661 175 836 55.40 0.09746 742
587.2 298 4.465 22.33 648 172 820 54.30 0.09957 732
550 279 4.321 21.61 606 161 767 50.80 0.10632 702
503.6 255 4.135 20.68 556 147 703 46.50 0.11610 664
500 263 4.120 20.60 550 146 696 46.20 0.11694 661
450 228 3.909 19.55 496 131 627 41.60 0.12991 618
400 203 3.685 18.43 440 117 557 37.50 0.14618 574
350 177 3.447 17.24 385 102 487 33.20 0.16707 527
300 152 3.193 15.97 331 87.7 418 28.90 0.19470 478
250 127 2.913 14.57 225 73 348 24.40 0.23393 426
S TRANDING 1 2 / 7
653.1 331 4.709 23.55 577 335 911 68.50 0.09164 773
600 304 4.513 22.57 528 307 835 62.90 0.09977 732
550 279 4.321 21.61 483 281 764 57.60 0.10884 693
500 253 4.120 20.60 440 256 696 52.40 0.11971 652
450 228 3.909 19.55 396 230 626 47.20 0.13299 610
400 203 3.685 18.43 352 204 556 42.40 0.14965 566
350 177 3.447 17.24 308 179 487 37.40 0.17102 520
300 152 3.193 15.97 265 153 418 32.80 0.19932 472
250 127 2.913 14.57 220 128 348 27.60 0.23947 420
Note :
+ Ampacity calculated on : 25°C Ambient Temperature, 75°C conductor temperature, 0.61m/s wind speed, 900 W/m2 Intensity of Solar Radiation, 0.6 Solar Radiation
Absorption Coefficient, 0.5 Emissivity Coefficient.
www.eescable.com 32
ASTM B524
Aluminium Conductor
Aluminium Alloy Reinforced(ACAR)
S TRANDING 4 / 3
246.9 125 4.770 14.31 197 147 344 26.90 0.24462 414
211.6 107 4.417 13.25 168 126 294 23.00 0.28528 376
195.7 99.1 4.247 12.74 156 116 272 21.30 0.30858 358
167.8 85 3.932 11.80 134 99.7 234 18.30 0.36000 324
155.4 78.7 3.785 11.36 124 92.4 216 17.10 0.38851 309
133.1 67.4 3.503 10.51 106 79.1 185 14.70 0.45358 280
123.3 62.5 3.371 10.11 98.2 73.3 171 13.65 0.48979 267
105.6 53.5 3.119 9.36 84.1 62.8 147 12.00 0.57214 242
77.47 39.3 2.672 8.02 61.7 46.1 108 8.94 0.77958 199
66.36 33.6 2.474 7.42 52.9 39.5 92.4 7.79 0.90935 180
48.69 24.7 2.118 6.35 38.8 29 67.8 5.76 1.24073 148
41.74 21.2 1.961 5.88 33.2 24.8 58 4.97 1.44736 135
30.59 15.5 1.679 5.04 24.4 18.2 42.6 3.67 1.97437 111
Note :
+ Ampacity calculated on : 25°C Ambient Temperature, 75°C conductor temperature, 0.61m/s wind speed, 900 W/m2 Intensity of Solar Radiation, 0.6 Solar Radiation
Absorption Coefficient, 0.5 Emissivity Coefficient.
www.eescable.com 33
ACCC
Aluminum Conductor Composite
Core(ACCC)
www.eescable.com 34
ACCC
Aluminum Conductor Composite
Core(ACCC)
www.eescable.com 35
ACCC
Aluminum Conductor Composite
Core(ACCC)
www.eescable.com 36
ASTM B416
Aluminium Clad Steel Strand(ACS)
Alumoweld wire and strand is used by power utilities, as well as formed wire and optical
ground wire manufacturers. Alumoweld outlasts other options by as much as 200%
in corrosive environments, significantly lowering maintenance and replacement costs.
When compared to solid aluminum wire, Alumoweld offers tremendous savings.
Features
Corrosion Resistance
Alumoweld overhead ground wire has excellent corrosion resistance. Its strength and
conductivity remain unchanged in any atmosphere where aluminum is satisfactory,
especially those known to be corrosive from industrial or atmosphericconditions.
This assurance against corrosion is obtained through the application of a thick covering of
pure aluminum, which provides a substantial barrier of protective metal. The minimum
Applications cladding thickness of Alumoweld is 10% of the radius of the wire. The cladding has a
• Overhead groundwire continuous, strong metallic bond to the steel core that will not crack or flake.
• Shield wire protecting transmission lines
against lightning damage Strength Comparable to Steel
Alumoweld also provides strength greater than or comparable to other overhead ground
wires. For commonly used wire sizes, the tensile strength of the individual wire can
approach 200,000 pounds per square inch. When used in a strand for overhead ground
wire, this high strength permits greater span lengths, less sag, and heavier loads under
storm loading conditions.
Lightweight
Directly related to strength and sag performance is the lighter weight of Alumoweld. Due
to its thick cladding of aluminum, Alumoweld is 15% lighter than a steel strand of
equivalent size. This lighter weight, combined with high strength, permits Alumoweld to
be installed to the same sags as steel with correspondingly lower tensions and lower
stresses on the towers or supporting structures.
www.eescable.com 37
ASTM B416
Aluminium Clad Steel Strand(ACS)
ALUMOWELDSTRANDASTMB-416
NUMBER& NOMINAL
NOMINAL STRAND BREAKING
SIZE OF WIRES WIRE WEIGHT RESISTANCE CROSSSECTION
DIAMETER LOAD
DIAMETER
LB/1000 KG/ OHMS/1000 OHMS/
AWG IN MM IN MM LB KG SQIN MM2
FT KM FT@68ºF KM@20ºC
37 No.6 0.1620 4.115 1.130 28.80 120,200 54,500 2222.00 3307.0 0.05356 0.1757 0.76264 492.20
37 No.7 0.1443 3.665 1.010 25.70 100,700 45,690 1762.00 2623.0 0.06754 0.2216 0.60509 390.30
37 No.8 0.1285 3.264 0.899 22.90 84,200 38,190 1398.00 2080.0 0.08516 0.2794 0.47984 309.50
37 No.9 0.1144 2.906 0.801 20.30 66,770 30,290 1108.00 1649.0 0.10740 0.3523 0.38032 245.50
37No.10 0.1019 2.588 0.713 17.90 52,950 24,020 879.00 1308.0 0.13540 0.4443 0.30174 194.70
19 No.5 0.1819 4.620 0.910 23.10 73,350 33,270 1430.00 2129.0 0.08224 0.2698 0.49438 318.70
19 No.6 0.1620 4.115 0.810 20.60 61,700 27,990 1134.00 1688.0 0.10370 0.3402 0.39163 252.70
19 No.7 0.1443 3.665 0.721 18.30 51,730 23,460 899.50 1339.0 0.13080 0.4290 0.31073 200.40
19 No.8 0.1285 3.264 0.642 16.30 43,240 19,610 713.50 1062.0 0.16490 0.5409 0.24641 158.90
19 No.9 0.1144 2.906 0.572 14.50 34,290 15,550 565.80 842.0 0.20790 0.6821 0.19530 126.10
19No.10 0.1019 2.588 0.509 12.90 27,190 12,330 448.70 667.7 0.26220 0.8601 0.15495 99.96
7 No.5 0.1819 4.620 0.546 13.90 27,030 12,260 524.90 781.1 0.22640 0.7426 0.18193 117.40
7 No.6 0.1620 4.115 0.486 12.40 22,730 10,310 416.30 619.5 0.28030 0.9198 0.14435 93.10
7 No.7 0.1443 3.665 0.433 11.00 19,060 8,645 330.00 491.1 0.35350 1.1600 0.11448 73.87
7 No.8 0.1285 3.264 0.385 9.78 15,930 7,226 261.80 389.6 0.44580 1.4630 0.09077 58.56
7 No.9 0.1144 2.906 0.343 8.71 12,630 5,729 207.60 308.9 0.56210 1.8440 0.07198 46.44
7No.10 0.1019 2.588 0.306 7.76 10,020 4,545 164.70 245.1 0.70880 2.3250 0.05708 36.83
7No.11 0.0907 2.304 0.272 6.91 7,945 3,604 130.60 194.4 0.89380 2.9320 0.04527 29.21
7No.12 0.0808 2.052 0.242 6.16 6,301 2,858 103.60 154.2 1.12700 3.6970 0.03590 23.16
3 No.5 0.1819 4.620 0.392 9.96 12,230 5,547 224.50 334.1 0.51770 1.6990 0.07796 50.32
3 No.6 0.1620 4.115 0.349 8.87 10,280 4,663 178.10 265.0 0.65280 2.1420 0.06185 39.90
3 No.7 0.1443 3.665 0.311 7.90 8,621 3,910 141.20 210.1 0.82320 2.7010 0.04905 31.65
3 No.8 0.1285 3.264 0.277 7.03 7,206 3,269 112.00 166.7 1.03800 3.4060 0.03890 25.10
3 No.9 0.1144 2.906 0.247 6.26 5,715 2,592 88.81 132.2 1.30900 4.2940 0.03085 19.90
3No.10 0.1019 2.588 0.220 5.58 4,532 2,056 70.43 104.8 1.65100 5.4150 0.02446 15.78
ALUMOWELDSTRANDASTMB-415
No.4 0.2043 5.189 115 109.0 5,081 2,305 93.63 139.3 1.222 4.009 0.03278 21.15
No.5 0.1819 4.620 165 116.0 4,290 1,946 74.25 110.5 1.541 5.056 0.02599 16.77
No.6 0.1620 4.115 175 123.0 3,608 1,637 58.88 87.6 1.943 6.375 0.02062 13.30
No.7 0.1443 3.665 185 130.1 3,025 1,372 46.69 69.5 2.450 8.038 0.01635 10.55
No.8 0.1285 3.264 195 137.1 2,529 1,147 37.03 55.1 3.089 10.130 0.01297 8.37
No.9 0.1144 2.906 195 137.1 2,005 909 29.37 43.7 3.896 12.780 0.01028 6.63
No.10 0.1019 2.588 195 137.1 1,590 721 23.29 34.7 4.912 16.120 0.00816 5.26
No.11 0.0907 2.304 195 137.1 1,261 572 18.47 27.5 6.194 20.320 0.00647 4.17
No.12 0.0808 2.052 195 137.1 1,000 454 14.65 21.8 7.811 25.630 0.00513 3.31
www.eescable.com 38
ASTM B549
Aluminium Conductor Aluminium Clad
Steel Reinforced(ACSR AW)
APPLICATIONS
Used as bare overhead transmission and as primary and secondary distribution cable. ACSR/AW offers
strength characteristics similar to ACSR, along with slightly greater ampacity and resistance to corrosion due
to aluminum-cladding of the steel core wires.
SPECIFICATIONS
Southwire's ACSR/AW bare conductor meets or exceeds the following ASTM specifications:
CONSTRUCTION
www.eescable.com 39
ASTM B549
Aluminium Conductor Aluminium Clad
Steel Reinforced(ACSR AW)
Swan/Aw 4 6/1 .0834 .0834 .0834 .25 39 16 55 1780 .3917 .4770 145
Swanate/Aw 4 7/1 .0772 .103 .103 .257 39 24 63 2280 .3814 .4642 148
Sparrow/Aw 2 6/1 .1052 .1052 .1052 .316 62 25 87 2760 .2462 .2997 194
Sparate/Aw 2 7/1 .0974 .1298 .1298 .325 62 38 100 3510 .2396 .2917 198
Robin/Aw 1 6/1 .1181 .1181 .1181 .354 78 31 109 3450 .1950 .2373 225
Raven/Aw 1/0 6/1 .1327 .1327 .1327 .398 99 39 138 4250 .1547 .1884 260
Quail/Aw 2/0 6/1 .1489 .1489 .1489 .447 124 50 174 5130 .1227 .1494 301
Pigeon/Aw 3/0 6/1 .1672 .1672 .1672 .502 156 63 219 6300 .09747 .1188 347
Penguin/Aw 4/0 6/1 .1878 .1878 .1878 .563 197 79 277 7690 .07726 .09422 402
Waxwing/Aw 266.8 18/1 .1217 .1217 .1217 .609 250 33 283 6820 .06364 .07776 451
Partridge/Aw 266.8 26/7 .1013 .0788 .2363 .642 251 98 349 10800 .06169 .07541 465
Ostrich/Aw 300.0 26/7 .1074 .0835 .2506 .68 283 110 393 12100 .05489 .06712 500
Merlin/Aw 336.4 18/1 .1367 .1367 .1367 .684 315 42 357 8540 .05044 .06175 522
Linnet/Aw 336.4 26/7 .1137 .0885 .2654 .72 317 123 440 13500 .04897 .05989 537
Oriole/Aw 336.4 30/7 .1059 .1059 .3177 .741 318 177 494 16700 .04795 .05861 547
Chickadee/Aw 397.5 18/1 .1486 .1486 .1486 .743 373 50 422 9780 .04268 .05230 580
Brant/Aw 397.5 24/7 .1287 .0858 .2574 .772 374 116 490 14100 .04185 .05124 592
Ibis/Aw 397.5 26/7 .1236 .0962 .2885 .783 374 146 520 15800 .04144 .05072 597
Lark/Aw 397.5 30/7 .1151 .1151 .3453 .806 375 209 584 19600 .04059 .04965 608
Pelican/Aw 477 18/1 .1628 .1628 .1628 .814 447 59 507 11500 .03556 .04344 651
Flicker/Aw 477 24/7 .141 .094 .2819 .846 449 139 589 16700 .03487 .04273 663
Hawk/Aw 477.0 26/7 .1354 .1053 .316 .858 449 175 624 18900 .03453 .04231 669
Hen/Aw 477.0 30/7 .1261 .1261 .3783 .883 450 251 701 23400 .03382 .04139 682
Osprey/Aw 556.5 18/1 .1758 .1758 .1758 .879 522 69 591 13200 .03050 .03749 715
Parakeet/Aw 556.5 24/7 .1523 .1015 .3045 .914 524 163 687 19300 .02989 .03667 731
Dove/Aw 556.5 26/7 .1463 .1138 .3413 .927 524 204 728 21900 .02958 .03627 737
Eagle/Aw 556.5 30/7 .1362 .1362 .4086 .953 525 293 818 26800 .02899 .03551 751
Peacock/Aw 605.0 24/7 .1588 .1058 .3175 .953 570 177 746 21000 .02749 .03377 770
Squab/Aw 605.0 26/7 .1525 .1186 .3559 .966 570 222 792 23600 .02588 .03341 777
Teal/Aw 605.0 30/19 .142 .0852 .426 .994 571 311 883 28500 .02672 .03274 791
Kingbird/Aw 636.0 18/1 .188 .188 .188 .94 596 79 675 15000 .02667 .03286 778
Rook/Aw 636.0 24/7 .1628 .1085 .3256 .977 599 186 785 22000 .02616 .03216 794
Grosbeak/Aw 636.0 26/7 .1564 .1216 .3649 .991 599 233 832 24800 .02588 .03179 801
Flamingo/Aw 666.6 24/7 .1667 .1111 .3333 1 628 195 823 23100 .02495 .03069 818
Gannet/Aw 666.6 26/7 .1601 .1245 .3736 1.014 628 245 872 26000 .02470 .03034 825
Starling/Aw 715.5 26/7 .1659 .129 .3871 1.051 674 263 936 27500 .02300 .02830 863
www.eescable.com 40
ASTM B549
Aluminium Conductor Aluminium Clad
Steel Reinforced(ACSR AW)
Redwing/Aw 715.5 30/19 .1544 .0927 .4633 1.081 676 368 1044 33400 .02260 .02777 878
Cuckoo/Aw 795.0 24/7 .182 .1213 .364 1.092 749 232 981 27500 .02093 .02582 913
Drake/Aw 795 26/7 .1749 .136 .408 1.107 749 292 1040 30500 .02070 .02549 922
Tern/Aw 795 45/7 .1329 .0886 .2658 1.063 749 124 873 21500 .02135 .02638 896
Condor/Aw 795 54/7 .1213 .1213 .364 1.092 749 232 981 27800 .02091 .02578 913
Mallard/Aw 795 30/19 .1628 .0977 .4884 1.139 751 409 1160 37100 .02033 .02500 938
Ruddy/Aw 900 45/7 .1414 .0943 .2828 1.131 848 140 988 24000 .01886 .02330 970
Canary/Aw 900 54/7 .1291 .1291 .3873 1.162 848 263 1111 31000 .01849 .02286 986
Rail/Aw 954 45/7 .1456 .0971 .2912 1.165 899 149 1047 25400 .01779 .02210 1003
Cardinal/Aw 954 54/7 .1329 .1329 .3987 1.196 899 279 1177 32900 .01744 .02161 1022
Ortolan/Aw 1033.5 45/7 .1515 .101 .3031 1.212 973 161 1134 27200 .01641 .02044 1054
Curlew/Aw 1033.5 54/7 .1383 .1383 .415 1.245 973 302 1275 35200 .01609 .01997 1074
Bluejay/Aw 1113 45/7 .1573 .1048 .3145 1.258 1048 173 1222 29300 .01606 .01905 1103
Pheasant/Aw 1272 54/19 .1535 .0921 .4604 1.381 1204 364 1568 42400 .01315 .01646 1216
Bobolink/Aw 1431 45/7 .1783 .1189 .3566 1.427 1348 223 1571 37600 .01186 .01503 1283
Lapwing/Aw 1590 45/7 .188 .1253 .3759 1.504 1498 248 1745 41800 .01069 .01366 1365
+Conductor temperature of 75°C ambient temperature 25°C, emissivity 0.5, wind 2 ft./sec., insun.
HIGH MECHANICALSTRENGTH
Grouse/AW 80.0 8/1 .1000 .1670 .1670 .367 75.1 62.6 137.7 4,890 .1942 .2357 227
Petrel/AW 101.8 12/7 .0921 .0921 .2763 .460 96.0 133.9 229.9 9,910 .1425 .1736 281
Minorca/AW 110.8 12/7 .0961 .0961 .2883 .481 104.5 145.8 250.3 10,800 .1326 .1594 297
Leghorn/AW 134.6 12/7 .1059 .1059 .3177 .530 127.0 177.0 304.0 13,000 .1078 .1313 335
Guinea/AW 159.0 12/7 .1151 .1151 .3453 .576 150.0 209.1 359.1 15,300 .09123 .1112 372
Dotterel/AW 176.9 12/7 .1214 .1214 .3642 .607 166.8 232.7 399.5 16,900 .08201 .09988 398
Dorking/AW 190.8 12/7 .1261 .1261 .3783 .631 180.0 251.0 431.0 18,300 .07601 .09261 418
Brahma/AW 203.2 16/19 .1127 .0977 .4885 .714 191.7 411.0 602.7 27,100 .06570 .07994 464
Cochin/AW 211.3 12/7 .1327 .1327 .3981 .664 199.3 278.0 477.3 19,800 .06863 .08364 445
+Conductor temperature of 75°C ambient temperature 25°C, emissivity 0.5, wind 2 ft./sec., insun.
www.eescable.com 41
ASTM B232
Aluminium Conductor Steel
Reinforced(ACSR)
THRUSH 5 16.83 2.81 19.64 7 10.58 6/1.89 1/1.89 5.67 46.0 22 68 6.68 1.6987
SWAN 4 21.18 3.53 24.71 6 13.29 6/2.12 1/2.12 6.36 58.0 27 85 8.30 1.3501
SWANATE 4 21.12 5.35 26.47 6 13.29 7/1.96 1/2.61 6.53 58.0 42 100 10.68 1.3539
SWALLOW 3 26.69 4.45 31.14 5 16.77 6/2.38 1/2.38 7.14 73.0 35 108 10.21 1.0712
SPARROW 2 33.59 5.60 39.19 4 21.16 6/2.67 1/2.67 8.01 92.0 44 136 12.69 0.8512
SPARATE 2 33.54 8.55 42.09 4 21.16 7/2.47 1/3.30 8.24 92.0 67 159 16.14 0.8525
ROBIN 1 42.41 7.07 49.48 3 26.65 6/3.00 1/3.00 9.00 116.0 55 171 15.81 0.6742
RAVEN 1/0 53.52 8.92 62.44 2 33.61 6/3.37 1/3.37 10.11 147.0 69 216 19.35 0.5343
QUAIL 2/0 67.33 11.22 78.55 1 42.39 6/3.78 1/3.78 11.34 185.0 87 272 23.27 0.4247
PIGEON 3/0 85.12 14.19 99.31 1/0 53.48 6/4.25 1/4.25 12.75 234.0 110 344 29.42 0.3359
PENGUIN 4/0 107.20 17.87 125.10 2/0 67.42 6/4.77 1/4.77 14.31 294.0 139 433 36.54 0.2667
WAXWING 266.8 135.00 7.50 142.50 3/0 85.03 18/3.09 1/3.09 15.45 372.0 59 431 30.27 0.2118
OWL 266.8 135.40 17.62 153.00 3/0 85.03 6/5.36 7/1.79 16.09 371.0 138 512 42.95 0.2112
PARTRIDGE 266.8 134.90 21.99 156.90 3/0 85.03 26/2.57 7/2.00 16.28 373.0 172 545 50.23 0.2141
OSTRICH 300 152.20 24.71 176.90 189 95.48 26/2.73 7/2.12 17.28 422.0 193 615 56.55 0.1897
MERLIN 336.4 170.20 9.46 179.70 4/0 107.23 18/3.47 1/3.47 17.35 469.0 74 543 38.17 0.1688
LINNET 336.4 170.60 27.83 198.40 4/0 107.23 26/2.89 7/2.25 18.31 473.0 217 690 62.76 0.1693
ORIOLE 336.4 170.50 39.78 210.30 4/0 107.23 30/2.69 7/2.69 18.83 474.0 311 785 77.43 0.1698
CHICKADEE 397.7 200.90 11.16 212.10 250 126.45 18/3.77 1/3.77 18.85 555.0 87 642 43.37 0.1430
BRANT 397.5 201.60 26.13 227.70 250 126.45 24/3.27 7/2.18 19.62 558.0 204 762 64.72 0.1433
IBIS 397.5 201.30 32.73 234.00 250 126.45 26/3.14 7/2.44 19.88 558.0 256 814 72.05 0.1434
LARK 397.5 200.90 46.88 247.80 250 126.45 30/2.92 7/2.92 20.44 558.0 367 925 90.30 0.1441
www.eescable.com 42
ASTM B232
Aluminium Conductor Steel
Reinforced(ACSR)
477 241.60 31.40 273.00 300 152.26 24/3.58 7/2.39 21.49 669.0 245 914 76.78 0.1195
FLICKER
477 241.60 39.49 281.10 300 152.26 26/3.44 7/2.68 21.80 669.0 306 975 86.73 0.1195
HAWK
477 241.30 56.30 297.60 300 152.26 30/3.20 7/3.20 22.40 670.0 440 1110 105.16 0.1200
HEN
556.5 282.50 15.69 298.20 350 172 18/4.47 1/4.47 22.35 779.0 122 901 60.52 0.1017
OSPREY
PARAKEET 556.5 282.30 36.60 318.90 350 172 24/3.87 7/2.58 23.22 783.0 286 1069 88.29 0.1023
556.5 282.60 45.92 328.50 350 172 26/3.72 7/2.89 23.55 783.0 359 1142 101.10 0.1022
DOVE
556.5 282.10 65.82 347.90 350 172 30/3.46 7/3.46 24.21 784.0 515 1298 122.90 0.1026
EAGLE
PEACOCK 605 306.10 39.78 345.90 381 187 24/4.03 7/2.69 24.20 849.0 311 1160 95.86 0.0943
SQUAB 605 305.80 49.81 355.60 381 187 26/3.87 7/3.01 24.51 848.0 389 1237 109.60 0.0944
WOODDUCK 605 307.10 71.65 378.80 381 187 30/3.61 7/3.61 25.25 853.0 560 1413 129.00 0.0943
605 307.10 69.62 376.70 381 187 30/3.61 19/2.16 25.24 853.0 545 1398 136.10 0.0943
TEAL
636 323.00 17.95 341.00 400 197 18/4.78 1/4.78 23.90 891.0 140 1031 69.72 0.0890
KINGBIRD
ROOK 636 323.10 41.88 365.00 400 197 24/4.14 7/2.76 24.84 896.0 327 1223 101.00 0.0894
GROSBEAK 636 321.80 52.49 374.30 400 197 26/3.97 7/3.09 25.15 892.0 410 1302 111.90 0.0897
SCOTER 636 322.60 75.26 397.90 400 197 30/3.70 7/3.70 25.90 897.0 588 1485 135.50 0.0897
636 322.60 73.54 396.10 400 197 30/3.70 19/2.22 25.90 897.0 576 1473 140.60 0.0897
EGRET
666.6 337.30 43.72 381.00 419 206 24/4.23 7/2.82 25.34 935.0 342 1277 105.50 0.0856
FLAMINGO
GANNET 666.6 338.30 54.90 393.20 419 201 26/4.07 7/3.16 25.76 938.0 429 1367 117.30 0.0854
CROW 715.5 361.60 46.88 408.50 450 221 54/2.92 7/2.92 26.28 1003.0 366 1369 115.20 0.0799
STILT 715.5 363.30 46.88 410.20 450 222 24/4.39 7/2.92 26.32 1007.0 366 1373 113.30 0.0795
STARLING 715.5 361.90 59.15 421.10 450 221 26/4.21 7/3.28 26.68 1004.0 462 1466 125.90 0.0798
REDWING 715.5 362.10 82.41 444.50 450 221 30/3.92 19/2.35 27.43 1006.0 645 1651 153.70 0.0800
www.eescable.com 43
ASTM B232
Aluminium Conductor Steel
Reinforced(ACSR)
TERN 795 403.80 27.83 431.60 500 246 45/3.38 7/2.25 27.03 1120.0 217 1337 97.47 0.0715
CONDOR 795 402.30 52.15 454.50 500 245 54/3.08 7/3.08 27.72 1116.0 407 1523 124.30 0.0718
CUCKOO 795 402.30 52.15 454.50 500 245 24/4.62 7/3.08 27.72 1116.0 407 1523 123.80 0.0718
DRAKE 795 402.60 65.44 468.00 500 246 26/4.44 7/3.45 28.11 1116.0 511 1627 139.70 0.0717
MALLARD 795 403.80 91.78 495.60 500 246 30/4.14 19/2.48 28.96 1122.0 718 1840 171.20 0.0717
CRANE 874.5 442.50 57.36 499.90 550 270 54/3.23 7/3.23 29.07 1221.0 448 1669 136.70 0.0649
RUDDY 900 455.50 31.67 487.20 566 278 45/3.59 7/2.40 28.74 1268.0 247 1510 109.40 0.0634
CANARY 900 456.30 59.15 515.50 566 278 54/3.28 7/3.28 29.52 1265.0 462 1727 141.00 0.0633
RAIL 954 483.80 33.54 517.30 600 295 45/3.70 7/2.47 29.61 1342.0 262 1604 116.10 0.0597
CARDINAL 954 484.50 62.81 547.30 600 296 54/3.38 7/3.38 30.42 1343.0 491 1834 149.70 0.0596
ORLAN 1033.5 523.90 36.31 560.20 650 320 45/3.85 7/2.57 30.81 1453.0 283 1736 123.30 0.0551
CURLEW 1033.5 525.50 68.10 593.60 650 321 54/3.52 7/3.52 31.68 1457.0 532 1989 162.40 0.0550
BLUEJAY 1113 565.50 38.90 604.40 700 345 45/4.00 7/2.66 31.98 1568.0 304 1872 132.70 0.0511
FINCH 1113 565.00 71.57 636.60 700 345 54/3.65 19/2.19 32.85 1574.0 560 2134 174.60 0.0514
BUNTING 1192.5 605.80 41.90 647.70 750 370 45/4.14 7/2.76 33.12 1680.0 327 2007 142.40 0.0477
GRACKLE 1192.5 602.80 76.90 679.70 750 368 54/3.77 19/2.27 33.97 1680.0 601 2281 184.20 0.0481
BITTERN 1272 644.40 44.70 689.10 800 393 45/4.27 7/2.85 34.17 1787.0 349 2136 151.40 0.0448
PHEASANT 1272 645.10 81.71 726.80 800 394 54/3.90 19/2.34 35.10 1797.0 640 2137 194.10 0.0450
DIPPER 1351.5 684.20 47.20 731.10 850 417 45/4.40 7/2.92 35.16 1897.0 366 2263 160.30 0.0422
MARTIN 1351.5 685.40 86.70 772.10 850 418 54/4.02 19/2.41 36.17 1910.0 678 2588 206.10 0.0423
BOBOLINK 1431 725.20 50.10 775.40 900 442 45/4.53 7/3.02 36.24 2011.0 392 2403 168.60 0.0398
PLOVER 1431 726.90 91.80 818.70 900 443 54/4.14 19/2.48 37.24 2025.0 719 2744 218.40 0.0399
NUTHATCH 1510.5 764.20 52.80 817.00 950 466 45/4.65 7/3.10 37.20 2119.0 413 2532 177.60 0.0378
PARROT 1510.5 766.10 97.00 863.10 950 467 54/4.25 19/2.55 38.25 2134.0 760 2894 230.50 0.0379
www.eescable.com 44
ASTM B232
Aluminium Conductor Steel
Reinforced(ACSR)
LAPWING 1590 804.10 55.60 859.80 1000 491 45/4.77 7/3.18 38.16 2230.0 424 2664 186.90 0.0359
FALCON 1590 806.20 102.40 908.70 1000 492 54/4.36 19/2.62 39.26 2246.0 802 3048 243.00 0.0360
CHUKER 1780 903.20 73.50 976.70 1119 551 84/3.70 19/2.22 40.70 2516.0 576 3092 227.80 0.0321
GROUSE 80 40.54 14.12 54.66 50 25 8/2.54 1/4.24 9.32 111.0 110 221 23.06 0.7089
PETREL 101.8 51.61 30.10 81.71 64 32 12/2.34 7/2.34 11.70 143.0 235 378 46.16 0.5595
MIORCA 110.8 56.11 32.73 88.84 70 34 I 2/2.44 7/2.44 12.20 155.0 256 411 50.19 0.5146
LEGHORN 134.6 68.20 39.78 108.00 85 42 12/2.69 7/2.69 13.46 189.0 311 500 60.67 0.4234
GUINEA 159 80.36 46.88 127.20 100 49 12/2.92 7/2.92 14.60 223.0 367 590 71.10 0.3593
DOTTEREL 176.9 89.41 52.15 141.60 111 55 12/3.08 7/3.08 15.40 248.0 408 656 76.68 0.3230
DORKING 190.8 96.5 I 56.30 152.80 120 59 12/3.20 7/3.20 16.00 267.0 440 707 82.77 0.2992
COCHIN 211.3 107.00 62.44 169.40 133 65 12/3.37 7/3.37 16.85 296.0 488 784 91.79 0.2698
BRAHMA 203.2 102.80 91.78 194.60 128 63 16/2.86 19/2.48 18.12 285.0 718 1003 126.52 0.2809
www.eescable.com 45
BS 215
Aluminium Conductor Steel
Reinforced(ACSR)
Strand
ing
Calculat
Nominal Equivale and Maximumdc
Co Overall ed
aluminiu nt copper wire Totalarea Weights resistance at
de diamet breaking
m area area diamete 20 oC
Na er load
r
me
Aluminium Steel Aluminium Steel Total Aluminium Steel Total
mm2 mm2 mm mm mm mm2 mm2 mm2 kg/km kg/km kg/km kN Ω/km
MOLE 10 6.5 6/1.50 1/1.50 4.5 10.6 1.77 12.4 29 14 43 4.1 2.7060
SQUIRREL 20 12.9 6/2.11 1/2.11 6.33 20.98 3.49 24.5 58 27 85 7.9 1.3700
GOPHER 25 16.1 6/2.36 1/2.36 7.08 26.25 4.37 30.6 72 34 106 9.6 1.0930
WEASEL 30 19.4 6/2.59 1/2.59 7.77 31.61 5.27 36.9 87 41 128 11.4 0.9077
FOX 35 22.6 6/2.79 1/2.79 8.37 36.68 6.11 42.8 101 48 149 13.2 0.7822
FERRET 40 25.8 6/3.00 1/3.00 9 42.41 7.07 49.5 117 55 172 15.2 0.6766
RABBIT 50 32.3 6/3.35 1/3.35 10.05 52.88 8.81 61.7 145 69 214 18.4 0.5426
MINK 60 38.7 6/3.66 1/3.66 10.98 63.13 10.52 73.7 173 82 255 21.9 0.4545
SKUNK 60 38.7 12/2.59 7/2.59 12.95 63.22 36.88 100.1 175 290 465 52.9 0.4568
BEAVER 70 45.2 6/3.99 1/3.99 11.97 75.02 12.50 87.5 205 97 302 25.8 0.3825
HORSE 70 45.2 12/2.79 7/2.79 13.95 73.36 42.80 116.2 203 335 538 61.2 0.3936
RACOON 75 48.4 6/4.10 1/4.10 12.3 79.21 13.20 92.4 217 103 320 27.2 0.3623
OTTER 80 51.6 6/4.22 1/4.22 12.66 83.92 13.99 97.9 230 109 339 28.8 0.3419
CAT 90 58.1 6/4.50 1/4.50 13.5 95.43 15.90 111.3 262 124 386 32.7 0.3006
HARE 100 64.5 6/4.72 1/4.72 14.16 105 17.50 122.5 288 137 425 35.9 0.2733
DOG 100 64.5 6/4.72 7/1.57 14.15 105 13.55 118.6 288 106 394 32.7 0.2733
HYENA 100 64.5 7/4.39 7/1.93 14.57 106 20.48 126.5 290 160 450 41.0 0.2702
LEOPARD 125 80.7 6/5.28 7/1.75 15.81 131.4 16.84 148.5 360 132 492 40.8 0.2185
COYOTE 125 80.7 26/2.54 7/1.91 15.89 131.7 20.06 151.8 365 157 522 46.3 0.2191
COUGAR 125 80.7 18/3.05 1/3.05 15.25 131.5 7.31 138.8 362 57 419 30.1 0.2190
www.eescable.com 46
BS 215
Aluminium Conductor Steel
Reinforced(ACSR)
PANTHER 200 129 30/3.00 7/3.00 21 212.1 49.48 261.6 586 388 974 92.3 0.1363
LION 225 145 30/3.18 7/3.18 22.26 238.3 55.60 293.9 659 436 1095 100.5 0.1212
BEAR 250 161 30/3.35 7/3.35 23.45 264.4 61.70 326.1 730 483 1213 111.2 0.1093
GOAT 300 194 30/3.71 7/3.71 25.97 324.3 75.67 400.0 896 593 1489 135.8 0.0891
SHEEP 350 226 30/3.99 7/3.99 27.93 375.1 87.53 462.6 1034 684 1718 156.3 0.0770
ANTELOPE 350 226 54/2.97 7/2.97 26.73 374.1 48.49 422.6 1032 379 1411 118.5 0.0773
BISON 350 226 54/3.00 7/3.00 27 381.7 49.48 431.2 1056 388 1444 120.9 0.0757
JAGUAR 200 130 18/3.86 1/3.86 19.3 210.6 11.70 222.3 580 91 671 46.6 0.1367
DEER 400 258 30/4.27 7/4.27 29.89 429.6 100.20 529.8 1186 785 1971 178.5 0.0673
ZEBRA 400 258 54/3.18 7/3.18 28.62 428.9 55.60 484.5 1186 435 1621 131.9 0.0674
ELK 450 290 30/4.50 7/4.50 31.5 477.1 111.30 588.4 I318 872 2190 198.3 0.0606
CAMEL 450 290 54/3.35 7/3.35 30.15 475.9 61.70 537.6 I314 483 1797 145.9 0.0607
MOOSE 500 323 54/3.53 7/3.53 31.77 528.5 68.51 597.0 1462 537 1999 161.0 0.0547
www.eescable.com 47
DIN 48204
Aluminium Conductor Steel
Reinforced(ACSR)
Stran
Area
ding Calcula Maximum
Equival
and ted DC
ent Overall
wire Weight breaking resistance
Nominal copper Diame
Aluminium Steel Total diamet load at 20 oC
area ter
er
Aluminium Steel Aluminium Steel Aluminium Steel Total
mm2 mm2 mm2 mm2 mm2 mm2 mm mm mm kg/km kg/km kg/km kN Ω /km
16 2.5 15.3 2.6 17.9 9.3 6/1.80 1/1.80 5.4 41.8 19.9 61.7 5.81 1.8793
25 4.0 23.8 4.0 27.8 14.5 6/2.25 1/2.25 6.8 65.4 31.0 96.4 9.02 1.2028
35 6.0 34.3 5.7 40.0 20.9 6/2.70 1/2.70 8.1 94.2 44.7 138.9 12.70 0.8353
44 32.0 44.0 31.7 75.7 26.8 14/2.00 7/2.40 11.2 121.4 248.2 369.6 45.46 0.6573
50 8.0 48.3 8.0 56.3 29.5 6/3.20 1/3.20 9.6 132.2 62.7 194.9 17.18 0.5946
50 30 51.2 29.8 81.0 31.2 12/2.33 7/2.33 11.7 141.1 233.9 375.0 44.28 0.5644
70 12 69.9 11.4 81.3 42.6 26/ I .85 7/1.44 11.7 192.8 89.4 282.2 26.31 0.4130
95 15 94.4 15.3 109.7 57.6 26/2. I 5 7/1.67 13.6 260.3 120.1 380.4 35.17 0.3058
95 55 96.5 56.3 152.8 58.9 12/3.20 7/3.20 16.0 266.2 441.1 707.3 80.20 0.2992
105 75 105.7 75.5 181.5 64.5 14/3.10 19/2.25 17.5 291.8 594.0 885.8 106.69 0.2376
120 20 121.6 19.8 141.4 74.2 26/2.44 711.90 15.5 335.5 155.5 491.0 44.94 0.2374
120 70 122.0 71.3 193.3 74.4 12/3.60 7/3.60 18.0 337.0 558.0 895.0 98.16 0.2364
125 30 127.9 29.8 157.7 78.0 30/2.33 7/2.33 16.1 353.0 233.9 586.9 57.86 0.2259
150 25 148.9 24.2 173.1 90.8 26/2.70 7/2.10 17.1 410.6 190.0 600.6 54.37 0.1939
170 40 171.8 40.1 211.9 104.8 30/2.70 712.7 18.9 474.2 314.0 788.2 77.01 0.1682
185 30 183.8 29.8 213.6 112.1 26/3.00 7/2.33 19 507.0 233.9 740.9 66.28 0.1571
www.eescable.com 48
DIN 48204
Aluminium Conductor Steel
Reinforced(ACSR)
210 35 209.1 34.1 243.2 128 26/3.20 7/2.49 20.3 576.6 267.1 843.7 74.94 0.1380
210 50 212.1 49.5 261.6 129 30/3.00 7/3.00 21.0 585.5 387.7 973.2 92.23 0.1363
230 30 230.9 29.8 260.7 141 24/3.50 7/2.33 21.0 636.5 233.9 870.4 73.09 0.1249
240 40 243.0 39.5 282.5 148 26/3.45 7/2.68 21.8 670.4 309.4 979.8 86.46 0.1188
265 35 263.7 34.1 297.8 161 24/3.74 7/2.49 22.4 726.9 267.1 994.0 82.94 0.1094
300 50 304.3 49.5 353.7 186 26/3.86 7/3.00 24.5 839.0 387.7 1226.7 105.09 0.0949
305 40 304.6 39.5 344.1 186 54/2.68 7/2.68 24.1 841.2 309.4 1150.6 99.30 0.0949
340 30 339.3 29.8 369.1 207 48/3.00 7/2.33 25.0 936.8 233.9 1170.7 92.56 0.0851
380 50 382.0 49.5 431.5 233 54/3.00 7/3.00 27.0 1054.3 387.7 1442.0 120.91 0.0757
385 35 386.0 34.1 420.1 235 48/3.20 7/2.49 26.7 1065.4 267.1 1332.5 194.31 0.0748
435 55 434.3 56.3 490.6 265 54/3.20 7/3.20 28.8 1199.0 441.1 1631.1 136.27 0.0666
450 40 448.7 39.5 488.2 274 48/3.45 7/2.68 28.7 1238.6 309.4 1548.0 120.19 0.0644
490 65 490.3 63.6 553.9 299 54/3.40 7/3.40 30.6 1353.7 498.0 1851.7 152.85 0.0590
550 70 550.0 71.3 621.3 336 54/3.60 7/3.60 32.4 1518.3 558.3 2076.6 167.42 0.0526
560 50 561.7 49.5 611.2 343 48/3.86 7/3.00 32.2 1550.2 387.7 1937.9 146.28 0.0514
680 85 678.6 86.0 764.6 414 54/4.00 19/2.40 36.0 1874.5 675.8 2550.3 209.99 0.0426
www.eescable.com 49
NFC 34125
Aluminium Conductor Steel
Reinforced(ACSR)
Maximum dc
Totalarea
Equivalent Stranding and overall Weight Rated resistance at
copper wire diameter diameter Strength 20 oC
area
Code Aluminium Steel Total Aluminium Steel Aluminium Steel Total
Name mm2 mm2 mm2 mm2 mm mm mm kg/km kg/km kg/km kN Ω /km
Canna37.7 28.27 9.42 37.69 17.2 9/2.0 3/2.0 8.3 78 77 155 1625 1.020
Canna59.7 37.30 21.99 59.29 22.8 12/2.0 7/2.0 10.0 104 172 276 3270 0.766
Canna75.5 47.71 27.83 75.54 29.1 12/2.25 7/2.25 11.25 131 218 349 4115 0.605
Canna93.3 58.9 34.34 93.3 36.0 12/2.5 7/2.5 12.50 162 269 431 4950 0.490
Canna116.2 94.25 21.99 116.24 57.5 30/2.0 7/2.0 14.0 260 172 432 4315 0.306
Canna147.1 119.28 27.83 147.11 72.8 30/2.25 7/2.25 15.75 329 218 547 5400 0.2430
Crocus147.1 119.28 27.83 147.11 72.8 30/2.25 7/2.25 15.75 329 218 547 6180 0.2430
Canna181.6 147.26 34.26 181.62 89.8 30/2.5 7/2.5 17.5 406 269 675 6490 0.1970
Canna228 184.72 43.10 227.82 112.7 30/2.8 7/2.8 19.6 512 338 847 8050 0.1570
Crocus228 184.72 43.10 227.82 112.7 30/2.8 7/2.8 19.6 510 338 847 9210 0.1570
Canna288 233.8 54.55 288.35 142.6 30/3.15 7/3.15 22.05 645 426 1071 9850 0.1240
Crocus288 233.8 54.55 288.35 142.6 30/3.15 7/3.15 22.05 645 426 1071 11380 0.1240
Crocus297 221.67 75.54 297.21 135.2 36/2.8 19/2.25 22.45 618 592 1210 14720 0.1310
Crocus412 325.72 85.95 411.67 198.7 32/3.6 19/2.4 26.4 906 674 1580 17330 0.0890
Crocus612 507.83 104.79 611.8 309.8 66/4.24 19/2.65 32.03 1408 822 2230 23150 0.0571
Crocus865 717.33 148.06 865.4 437.9 66/3.72 19/3.15 38.01 1990 1161 3151 31900 0.0404
Crocus1185 956.66 227.82 1185 583.6 54/2.80 37/2.8 44.7 2668 1792 4460 48050 0.0304
www.eescable.com 50
ASTM B911
Twisted Pair Conductor ACSR (TP-
ACSR)
Application: The ACSR Twisted Pair Conductor is used for MV, HV and
EHV overhead, long distance transmission and distribution, especially
suitable for overhead applications subject to aeolian vibration and galloping
due to wind.
Operating Temperature: Max permissible continuous operating
temperature of conductor shall not exceed 90℃.
S Standard: ASTM B911, or other standards required by customers.
Major dimension
minor
www.eescable.com 51
ASTM B911
Twisted Pair Conductor ACSR (TP-
ACSR)
www.eescable.com 52
ASTM B911
Twisted Pair Conductor ACSR (TP-
ACSR)
www.eescable.com 53
ASTM B856
Aluminum Conductor Steel
Supported(ACSS)
Resistance
Diameter (mm) Weight kg/km Rated Strength
Ω/km
Standar
Code Size Stranding Wires Complet d High
Steel DC @ AC @
Word kcmil Al/St e
Al Steel Total
Stren Streng
Core 20°C 75°C
Al St Cable gth th kN
kN
Partridge/ACSS 266.8 26/7 2.57 2.00 6.00 16.31 374 172 546 39.50 43.28 0.2063 0.2537
Junco/ACSS 266.8 30/7 2.40 2.40 7.19 16.76 375 246 621 52.04 57.83 0.2050 0.2520
Ostrich/ACSS 300 26/7 2.73 2.12 6.37 17.27 421 193 614 44.48 48.49 0.1837 0.2257
Linnet/ACSS 336.4 26/7 2.89 2.25 6.74 18.29 471 217 688 49.82 54.71 0.1637 0.2013
Oriole/ACSS 336.4 30/7 2.69 2.69 8.07 18.82 473 311 783 65.83 72.51 0.1627 0.2000
Brant/ACSS 397.5 24/7 3.27 2.18 6.54 19.61 557 204 761 48.93 53.82 0.1390 0.1713
Ibis/ACSS 397.5 26/7 3.14 2.44 7.33 19.89 557 256 813 57.83 63.16 0.1387 0.1707
Lark/ACSS 397.5 30/7 2.92 2.92 8.77 20.47 558 367 925 77.84 85.85 0.1377 0.1693
Flicker/ACSS 477 24/7 3.58 2.39 7.16 21.49 669 245 913 57.83 63.16 0.1160 0.1430
Hawk/ACSS 477 26/7 3.44 2.67 8.03 21.79 669 307 976 69.39 76.06 0.1153 0.1423
Hen/ACSS 477 30/7 3.20 3.20 9.61 22.43 670 440 1110 93.41 100.97 0.1147 0.1413
Parakeet/ACSS 556.5 24/7 3.87 2.58 7.73 23.22 780 285 1065 67.61 73.84 0.0993 0.1227
Dove/ACSS 556.5 26/7 3.72 2.89 8.67 23.55 780 358 1138 80.96 88.52 0.0990 0.1220
Eagle/ACSS 556.5 30/7 3.46 3.46 10.38 24.21 782 514 1295 108.98 117.88 0.0983 0.1210
Peacock/ACSS 605 24/7 4.03 2.69 8.06 24.21 848 310 1158 73.40 80.51 0.0913 0.1130
Squab/ACSS 605 26/7 3.87 3.01 9.04 24.54 848 390 1238 87.63 94.75 0.0910 0.1123
WoodDuck/ACSS 605 30/7 3.61 3.61 10.82 25.25 850 558 1408 115.65 125.88 0.0903 0.1113
Teal/ACSS 605 30/19 3.61 2.16 10.82 25.25 850 547 1397 118.32 130.33 0.0907 0.1117
Rook/ACSS 636 24/7 4.14 2.76 8.27 24.82 891 326 1217 76.95 84.52 0.0870 0.1073
Grosbeak/ACSS 636 26/7 3.97 3.09 9.27 25.17 891 410 1301 92.08 99.64 0.0867 0.1070
Scoter/ACSS 636 30/7 3.70 3.70 11.09 25.88 894 587 1481 121.88 132.11 0.0860 0.1060
Egret/ACSS 636 30/19 3.70 2.22 11.09 25.88 894 575 1468 124.55 137.45 0.0860 0.1063
Flamingo/ACSS 666.6 24/7 4.23 2.82 8.47 25.40 934 342 1276 80.96 88.52 0.0830 0.1027
www.eescable.com 54
ASTM B856
Aluminum Conductor Steel
Supported(ACSS)
Resistance
Diameter (mm) Weight kg/km Rated Strength
Ω/km
Size Stranding Standard
Code Word Wires Complet
kcmil Al/St Steel
e Strength High DC @ AC @
Core Al Steel Total kN Streng 20°C 75°C
Al St Cable
th kN
Gannet/ACSS 666.6 26/7 4.07 3.16 9.49 25.76 934 429 1364 96.53 104.09 0.0827 0.1020
Stilt/ACSS 715.5 24/7 4.39 2.92 8.77 26.31 1003 367 1370 86.74 94.75 0.0773 0.0957
Starling/ACSS 715.5 26/7 4.21 3.28 9.83 26.70 1003 461 1464 103.64 112.10 0.0770 0.0953
Redwing/ACSS 715.5 30/19 3.92 2.35 11.77 27.46 1005 647 1652 137.01 151.24 0.0767 0.0947
Cuckoo/ACSS 795 24/7 4.62 3.08 9.25 27.74 1114 408 1522 96.53 103.64 0.0697 0.0863
Drake/ACSS 795 26/7 4.44 3.45 10.36 28.12 1114 512 1626 115.21 124.55 0.0697 0.0857
Macaw/ACSS 795 42/7 3.50 1.94 5.82 26.80 1114 162 1276 52.49 56.05 0.0703 0.0873
Tern/ACSS 795 45/7 3.38 2.25 6.75 27.00 1114 217 1332 63.16 67.61 0.0700 0.0877
Condor/ACSS 795 54/7 3.08 3.08 9.25 27.74 1114 408 1522 96.53 103.64 0.0697 0.0887
Mallard/ACSS 795 30/19 4.14 2.48 12.41 28.93 1117 718 1835 152.57 168.59 0.0690 0.0850
Ruddy/ACSS 900 45/7 3.59 2.40 7.18 28.73 1261 246 1507 70.28 75.62 0.0620 0.0777
Canary/ACSS 900 54/7 3.28 3.28 9.84 29.51 1261 461 1723 109.43 117.43 0.0613 0.0787
Redbird/ACSS 954 24/7 5.06 3.38 10.13 30.38 1337 489 1826 115.65 124.55 0.0580 0.0723
Rail/ACSS 954 45/7 3.70 2.47 7.40 29.59 1337 261 1598 74.29 80.07 0.0583 0.0733
Towhee/ACSS 954 48/7 3.58 2.79 8.36 29.85 1337 333 1670 87.63 94.75 0.0583 0.0727
Cardinal/ACSS 954 54/7 3.38 3.38 10.13 30.38 1337 489 1826 115.65 124.55 0.0580 0.0743
Canvasback/ACSS 954 30/19 4.53 2.72 13.59 31.70 1340 862 2202 182.82 201.95 0.0573 0.0713
Snowbird/ACSS 1033.5 42/7 3.99 2.21 6.64 30.56 1448 210 1659 68.50 73.40 0.0540 0.0680
Ortolan/ACSS 1033.5 45/7 3.85 2.57 7.70 30.78 1448 283 1731 80.51 86.74 0.0540 0.0680
Curlew/ACSS 1033.5 54/7 3.51 3.51 10.54 31.62 1448 530 1978 125.44 134.78 0.0537 0.0687
Bluejay/ACSS 1113 45/7 4.00 2.66 7.99 31.95 1560 304 1864 86.74 93.86 0.0500 0.0633
Finch/ACSS 1113 54/19 3.65 2.19 10.94 32.82 1567 559 2126 135.23 147.68 0.0500 0.0643
Bunting/ACSS 1192.5 45/7 4.14 2.76 8.27 33.07 1671 326 1997 95.19 104.53 0.0467 0.0593
www.eescable.com 55
ASTM B856
Aluminum Conductor Steel
Supported(ACSS)
Resistance
Diameter (mm) Weight kg/km Rated Strength
Ω/km
Wires
Code Word Size Stranding
Steel
Complet
Standard High DC @ AC @
kcmil Al/St e Strength Streng
Core Al Steel Total 20°C 75°C
Cable kN th kN
Al St
Bittern/ACSS 1272 45/7 4.27 2.85 8.54 34.16 1783 348 2131 99.20 106.76 0.0437 0.0557
Pheasant/ACSS 1272 54/19 3.90 2.34 11.69 35.08 1791 639 2430 151.68 165.92 0.0437 0.0563
Dipper/ACSS 1351 45/7 4.40 2.93 8.80 35.20 1893 369 2263 105.42 113.43 0.0413 0.0527
Martin/ACSS 1351 54/19 4.02 2.41 12.05 36.17 1903 678 2581 161.03 176.15 0.0410 0.0533
Bobolink/ACSS 1431 45/7 4.53 3.02 9.06 36.25 2006 391 2397 111.65 120.10 0.0390 0.0500
Plover/ACSS 1431 54/19 4.14 2.48 12.41 37.21 2015 718 2734 170.81 186.38 0.0390 0.0503
Nuthatch/ACSS 1510 45/7 4.65 3.10 9.31 37.21 2116 413 2529 117.88 125.00 0.0370 0.0477
Parrot/ACSS 1510 54/19 4.25 2.55 12.74 38.23 2127 758 2885 179.71 196.61 0.0367 0.0480
Ratite/ACSS 1590 42/7 4.94 2.75 8.24 37.90 2228 323 2552 104.09 111.21 0.0350 0.0453
Lapwing/ACSS 1590 45/7 4.78 3.18 9.55 38.20 2228 435 2663 124.11 131.67 0.0350 0.0453
Falcon/ACSS 1590 54/19 4.36 2.62 13.08 39.22 2239 798 3038 189.49 207.29 0.0350 0.0457
Chukar/ACSS 1780 84/19 3.70 2.22 11.09 40.67 2507 575 3081 157.47 169.92 0.0313 0.0407
Mockingbird/ACSS 2034.5 72/7 4.27 2.85 8.54 42.70 2865 348 3213 120.99 128.55 0.0277 0.0367
Roadrunner/ACSS 2057 76/19 4.18 1.95 9.75 43.18 2897 444 3341 141.01 150.79 0.0273 0.0360
Bluebird/ACSS 2156 84/19 4.07 2.44 12.21 44.75 3036 696 3732 187.27 202.39 0.0260 0.0343
Kiwi/ACSS 2167 72/7 4.41 2.94 8.81 44.07 3052 370 3422 129.00 137.01 0.0260 0.0347
Thrasher/ACSS 2312 76/19 4.43 2.07 10.34 45.77 3256 499 3755 158.36 169.48 0.0243 0.0327
Joree/ACSS 2515 76/19 4.62 2.16 10.78 47.75 3542 543 4085 172.15 184.16 0.0223 0.0307
www.eescable.com 56
ASTM B452
Copper Clad Steel Strand(CCS)
www.eescable.com 57
ASTM B452
Copper Clad Steel Strand(CCS)
www.eescable.com 58
ASTM B452
Copper Clad Steel Strand(CCS)
19#4 19 0.2043 5.19 1.022 25.95 793,000 401.8 92.96 2346.4 3491.8 0.0451 0.1479 24474 11101
19#5 19 0.1819 4.62 0.910 23.10 628,700 318.6 73.70 1860.1 2768.1 0.0569 0.1866 19402 8800
19#6 19 0.1620 4.11 0.810 20.57 498,600 252.6 58.45 1475.3 2195.5 0.0717 0.2352 15389 6980
19#7 19 0.1443 3.67 0.722 18.33 395,600 200.5 46.38 1170.6 1742.0 0.0904 0.2965 12210 5538
19#8 19 0.1285 3.26 0.643 16.32 313,700 159.0 36.78 928.3 1381.4 0.1140 0.3739 9682 4392
19#9 19 0.1144 2.91 0.572 14.53 248,700 126.0 29.15 735.7 1094.9 0.1438 0.4717 7674 3481
4/0 19 0.1055 2.68 0.528 13.40 211,500 107.2 24.79 625.7 931.1 0.1691 0.5547 6526 2960
19#10 19 0.1019 2.59 0.510 12.94 197,300 100.0 23.13 583.7 868.7 0.1812 0.5946 6089 2762
7#4 7 0.2043 5.19 0.613 15.57 292,200 148.1 34.25 861.0 1281.4 0.1219 0.3999 9017 4090
7#5 7 0.1819 4.62 0.546 13.86 231,600 117.4 27.15 682.6 1015.8 0.1538 0.5045 7148 3242
7#6 7 0.1620 4.11 0.486 12.34 183,700 93.1 21.54 541.4 805.7 0.1939 0.6360 5670 2572
7#7 7 0.1443 3.67 0.433 11.00 145,800 73.9 17.09 429.6 639.3 0.2443 0.8016 4498 2040
2/0 7 0.1379 3.50 0.414 10.51 133,100 67.4 15.60 392.3 583.8 0.2675 0.8777 4108 1863
7#8 7 0.1285 3.26 0.386 9.79 115,600 58.6 13.55 340.6 506.9 0.3081 1.0108 3567 1618
1/0 7 0.1228 3.12 0.368 9.35 105,600 53.5 12.37 311.1 463.0 0.3374 1.1069 3258 1478
7#9 7 0.1144 2.91 0.343 8.72 91,610 46.4 10.74 270.0 401.8 0.3887 1.2754 2827 1282
7#10 7 0.1019 2.59 0.306 7.76 72,690 36.8 8.52 214.2 318.8 0.4900 1.6075 2243 1017
3#4 3 0.2043 5.19 0.440 11.18 125,200 63.4 14.68 368.3 548.1 0.2838 0.9313 4079 1850
3#5 3 0.1819 4.62 0.392 9.96 99,260 50.3 11.64 292.0 434.5 0.3581 1.1747 3234 1467
3#6 3 0.1620 4.11 0.349 8.86 78,730 39.9 9.23 231.6 344.6 0.4514 1.4811 2565 1163
3#7 3 0.1443 3.67 0.311 7.90 62,470 31.7 7.32 183.7 273.4 0.5690 1.8667 2035 923
3#8 3 0.1285 3.26 0.277 7.04 49,540 25.1 5.81 145.7 216.8 0.7175 2.3540 1614 732
3#9 3 0.1144 2.91 0.247 6.27 39,260 19.9 4.60 115.5 171.9 0.9053 2.9700 1279 580
3#10 3 0.1019 2.59 0.220 5.59 31,150 15.8 3.65 91.6 136.3 1.1410 3.7433 1015 460
#2AWG 7 0.0860 2.18 0.258 6.55 51,770 26.2 6.07 152.6 227.1 0.6879 2.2568 1614 732
#4AWG 7 0.0680 1.73 0.204 5.18 32,370 16.4 3.79 95.4 142.0 1.1002 3.6097 1009 458
#2AWG 1 0.2576 6.54 0.258 6.54 66,370 33.6 7.78 193.7 288.2 0.5313 1.7430 2276 1032
#4AWG 1 0.2043 5.19 0.204 5.19 41,740 21.2 4.89 121.8 181.2 0.8448 2.7716 1431 649
#6AWG 1 0.1620 4.12 0.162 4.12 26,250 13.3 3.08 76.6 114.0 1.3432 4.4069 900 408
#8AWG 1 0.1285 3.26 0.129 3.26 16,510 8.4 1.94 48.2 71.7 2.1354 7.0059 566 257
#9AWG 1 0.1144 2.91 0.114 2.91 13,090 6.6 1.53 38.2 56.8 2.6942 8.8393 449 204
#10AWG 1 0.1019 2.59 0.102 2.59 10,380 5.3 1.22 30.3 45.1 3.3957 11.1409 356 162
www.eescable.com 59
GSW
Galvanized Steel Wire Strand(GSW)
APPLICATIONS
Zinc-Coated steel wire is suitable for use as guys, messengers, stay wires, span wires,
suspension of telecommunication cables, the earth wire/ground wire in overhead lines,
barrier cable along the road or structure cable in construction, and for similar purposes
STANDARD
Produced according to standard IEC61089, ASTM A475, ASTM A363, BS183 or specific
requirements from customers
www.eescable.com 60
GSW
Galvanized Steel Wire Strand(GSW)
IEC61089
Diameter Rated Strenghth
Nominal Code Number o f Max.D.C.
Area Liner Mass
Area St Number Wires Resistance at20
Wire Cond. S1A S1B S2A S3A
℃
mm2 mm mm kg/km kn kn kn kn Ω/km
30 4 27.1 7 2.22 6.66 213.3 36.3 33.6 39.3 43.9 7.1445
40 6.3 42.7 7 2.79 8.36 335.9 55.9 51.7 60.2 67.9 4.5362
65 10 67.8 7 3.51 10.53 553.2 87.4 80.7 93.5 103 2.8578
85 12.5 84.7 7 3.93 11.78 666.5 109.3 100.8 116.9 128.8 2.2862
100 16 108.4 7 4.44 13.32 853.1 139.9 129 199.7 164.8 1.7861
100 16 108.4 19 2.7 13.48 857 142.1 131.2 152.9 172.4 1.7944
150 25 169.4 19 3.37 16.85 1339.1 218.6 201.6 238.9 262.6 1.1484
250 40 271.1 19 4.26 21.31 2141.6 349.7 322.6 374.1 412.1 0.7177
250 40 271.1 37 3.05 21.38 2148.1 349.7 322.6 382.3 420.2 0.7196
400 63 427 37 3.83 26.83 3383.2 550.8 508.1 589.3 649 0.4569
ASTM A475
P hysical P roperties of Zinc-C oated Steel W ire Strand
The num bers in boldface type indicate sizes and grades m ost com m only used and readily available
Nominal Num ber of Nominal Diameter Approximate Weight M inim um Breaking Strength of Strand,Ibf[KN]
Diameter of W ires in of Coated Wiresin of Strand Ib/1000
Strand in.[mm] Strand Strand in.[mm] ft[kg/km] Common Grade Siemens-Martin Grade High-Strength Grade Extra High-Strength Grade
1/8 3.18 7 0.041 1.04 32 48 540 2.402 910 4.048 1 330 5.916 1 830 8.140
5/32 3.97 7 0.052 1.32 51 76 870 3.870 1 470 6.539 2 140 9.519 2 940 13.078
3/16 4.76 7 0.062 1.57 73 109 1 150 5.115 1 900 8.452 2 850 12.677 3 990 17.748
3/16 4.76 7 0.065 1.65 80 119
7/32 5.56 3 0.104 2.64 88 131 1 400 6.228 2 340 10.409 3 500 15.569 4 900 21.796
7/32 5.56 7 0.072 1.83 98 146 1 540 6.850 2 560 11.387 3 850 17.126 5 400 24.020
1/4 6.35 3 0.120 3.05 117 174 1 860 8.274 3 40 13.523 4 730 21.040 6 740 29.981
1/4 6.35 3 0.120 3.05 117 174
1/4 6.35 7 0.080 2.03 121 180 1 900 8.452 3 150 14.012 4 750 21.129 6 650 29.581
9/32 7.14 3 0.130 3.30 137 204 2 080 9.252 3 380 15.035 5 260 23.398 7 500 33.362
9/32 7.14 7 0.093 2.36 164 244 2 570 11.432 4 250 18.905 6 400 28.469 8 950 39.812
5/16 7.94 3 0.145 3.68 171 255 2 490 11.076 4 090 18.193 6 350 28.246 9 100 40.479
5/16 7.94 7 0.104 2.64 205 305 3 200 14.234 5 350 23.798 8 000 35.586 11 200 49.82
5/16 7.94 7 1.109 2.77 225 335
3/8 9.52 3 0.165 4.19 220 328 3 330 14.813 5 560 24.732 8 360 37.187 11 800 52.489
3/8 9.52 7 0.120 3.05 273 407 4 250 18.905 6 950 30.915 10 800 48.040 15 400 68.503
7/16 11.11 7 0.145 3.68 399 595 5 700 25.355 9 350 41.591 14 500 64.499 20 800 92.523
1/2 12.70 7 0.165 4.19 517 770 7 400 32.917 12 100 53.823 18 800 83.627 26 900 119.657
1/2 12.70 19 0.100 2.54 504 751 7 620 33.895 12 700 56.492 19 100 84.961 26 700 118.768
9/16 14.29 7 0.188 4.78 671 1000 9 600 42.703 15 700 69.837 24 500 108.981 35 000 155.688
9/16 14.29 19 0.113 2.87 637 949 9 640 42.881 16 100 71.616 24 100 107.202 33 700 14.905
5/8 15.88 7 0.207 5.26 813 1211 11 600 51.599 19 100 84.961 29 600 131.667 42 400 188.605
5/8 15.88 19 0.125 3.18 796 1186 11 000 48.930 18 100 80.513 28 100 124.995 40 200 178.819
3/4 19.05 19 0.150 3.81 1 155 1721 16 000 71.172 26 200 116.543 40 800 181.487 58 300 259.331
7/8 22.22 19 0.177 4.50 1 581 2356 21 900 97.416 35 900 159.691 55 800 248.211 79 700 354.523
1 25.40 19 0.200 5.08 2 073 3089 28 700 127.664 47 000 209.066 73 200 325.610 104 500 464.839
1 25.40 37 0.143 3.63 2 057 3065 28 300 125.885 46 200 205.508 71 900 319.827 102 700 456.832
11/8 28.58 37 0.161 4.09 2 691 4010 36 000 160.136 58 900 262.000 91 600 407.457 130 800 581.827
11/4 31.75 37 0.179 4.55 3 248 4840 44 600 198.391 73 000 324.720 113 600 505.318 162 200 721.502
www.eescable.com 61
GSW
Galvanized Steel Wire Strand(GSW)
ASTM A363
Physical propertles of Zinc- coated steel Overhead Ground Wire Strand
Number of
Nominal Diameter
Wires in Nominal Diameter Approximate Weight
of Strand. Minimum Breaking Strength of Strand, lbf (KN)
of Strand. Strand of Coated Wire in
Strand.
In. mm in. mm lb/1000ft kg/km High-Strength Grade Extra-High- Strength Grade Utilities Grade
5/16 7.94 3 0.145 3.68 171 255 … … … … 6500 28.9
5/16 7.94 7 0.104 2.64 205 305 8000 35.6 11200 49.8 …
3/8 9.52 7 0.12 3.05 273 407 10800 48 15400 68.4 11500 51.2
7/16 11.11 7 0.145 3.68 399 595 14500 64.5 20800 92.5 … …
1/2 12.7 7 0.165 4.19 517 770 18800 83.6 26900 119.6 … …
BS 183
Construcrion Minimum breaking load ofstrand
Number of wores/ Approximate Approx.
strand diamerer Mass
wire diamerer Grade350 Grade480 Grade700 Grade850 Grade1000 Grade1150 Grade1300
mm KN KN KN KN KN KN KN kg/1000m
7/0.56 1.7 0.60 0.83 1.20 -- 1.70 1.98 2.24 14
7/0.71 2.1 0.97 1.33 1.94 -- 2.75 3.19 3.60 28
7/0.85 2.6 1.39 1.90 2.80 -- 3.95 4.57 5.15 31
7/0.90 2.7 1.55 2.14 3.10 -- 4.45 5.12 5.80 35
7/1.00 3.0 1.92 2.64 3.85 -- 5.50 6.32 7.15 43
7/1.25 3.8 3.01 4.10 6.00 -- 8.55 9.88 11.15 67
7/1.40 4.2 3.75 5.17 7.54 9.16 10.75 12.35 14.00 84
7/RS 4.3 3.85 5.28 7.70 9.35 11.00 12.65 14.30 86
7/1.60 4.8 4.90 6.75 9.85 11.95 14.10 16.20 18.30 110
7/1.80 5.4 6.23 8.55 12.45 -- 17.80 20.50 23.20 140
7/2.00 6.0 7.70 10.55 15.40 -- 22.00 25.30 38.60 170
7/2.36 7.1 10.70 14.70 21.40 -- 30.60 35.20 39.80 240
7/2.65 8.0 13.50 18.50 27.00 -- 38.60 44.40 50.20 300
7/3.00 9.0 17.30 23.75 34.65 -- 49.50 56.90 64.30 392
7/3.15 9.5 19.10 26.20 38.20 -- 54.55 62.75 70.90 430
7/3.25 9.8 20.30 27.85 40.65 -- 58.05 66.80 75.50 460
7/3.65 11.0 25.60 35.15 51.25 -- 73.25 84.20 95.20 570
7/4.00 12.0 30.90 42.20 61.60 -- 88.00 101.0 114.0 690
7/4.25 12.8 34.75 47.65 69.50 -- 99.30 114.0 129.0 780
7/4.75 14.0 43.40 59.45 86.80 -- 124.0 142.7 161.3 970
19/1.00 5.0 5.22 7.16 10.45 -- 14.92 17.16 19.40 120
19/1.25 6.3 8.16 11.19 16.32 -- 23.32 26.81 30.31 180
19/1.40 7.0 10.24 14.04 20.47 -- 29.25 33.64 38.02 230
19/1.60 8.0 13.37 18.34 26.75 -- 38.20 43.93 49.66 300
19/2.00 10.0 20.90 28.65 41.78 50.74 59.69 68.64 77.60 470
19/2.50 12.5 32.65 44.80 65.29 79.28 93.27 107.3 121.3 730
19/3.00 15.0 47.00 64.50 94.00 114.1 134.3 154.5 174.6 1050
19/3.55 17.8 65.80 90.27 131.6 159.9 188.0 216.3 244.5 1470
19/4.00 20.0 83.55 114.6 167.1 203.0 238.7 274.6 310.4 1870
19/4.75 23.8 117.85 161.6 235.7 286.0 336.7 387.2 437.7 2630
www.eescable.com 62
HDBC
Hard-drawn Bare Copper
Conductor(HDBC)
Standards / Testing
Specifications
• Bare conductors have been designed
according to ASTM B1, B8 specifications
and requirements of the latest version
Stranded
of the National Electrical Code (NEC).
Application Installation
For aerial power transmission and Hard drawn copper conductor can be
distribution line, circuit ground connections installed in air. It is recommended that the
as well as machinery and equipment installation instructions indicated by the Local
grounding. Electric Code, or any equivalent, be followed,
so that the safeguarding of persons and the
integrity of the product will not be affected
by deficiencies in the installation.
www.eescable.com 63
HDBC
Hard-drawn Bare Copper
Conductor(HDBC)
SOLID
Minimum
Diameter Resistance Minimum Tensile Total
Size Section Wire
DC @ 20°C
Elongation Strength Weight
CLASS “A”
Minimum
Minimum
Wire Tensile
Conductor Resistance
Minimu Total
Size Section Number Wire Elongatio m Strenght
DC @ 20°C n Before Tensile Weight
Of Wires Diameter Diameter Stranding After
Strenght
Stranding
AWG/MCM Cmils mm² mm mm Ω / km % kg / mm² kg kg / km
www.eescable.com 64
HDBC
Hard-drawn Bare Copper
Conductor(HDBC)
CLASS “B”
Minimum Minimu
Wire Minimu m Tensile
Size Section Wire Conducto Resistance Elongatio m Strenght Total
Number Diamete r DC @ 20°C n Before Tensile After Weigh
Of r Diameter Stranding Strenght Strandin t
Wires g
AWG/MCM Cmils mm² mm mm Ω / km % kg / mm² kg kg / km
www.eescable.com 65
Central Tube OPGW
Single/Double Armour layers
Optical Fiber Composite Overhead
Ground Wire(OPGW)
Opticalfibers
Characteristic andApplication
Small cable diameter and short-circuit current capacity, light weight.
The stainless steel tube can form a suitable primary fiber excess length.
The OPGW has slightly worse tensile, torsion and crush resistance
performance.
Apply to the transformation of old lines.
www.eescable.com 66
Central Tube OPGW
Single/Double Armour layers
Optical Fiber Composite Overhead
Ground Wire(OPGW)
Typical Parameters:
Single Layer
Double Layers
www.eescable.com 67
OPGW With Stranded Layers
Optical Fiber Composite Overhead
Ground Wire(OPGW)
Opticalfibers
Characteristic andApplication
larger cable diameter and much more fiber count.
larger tensile strength and fault current capacity to reach a better balance of
electrical and mechanicalperformance.
The amount of Stainless Steel Tube could be 1, 2 or 3 (max. at present).
Optimum stranding design to reach a suitable secondary fiber excess length.
The stranded layers could be double layers or three layers, the stranded wires
could be ASwires with/or AA and Al wires.
www.eescable.com 68
OPGW With Stranded Layers
Optical Fiber Composite Overhead
Ground Wire(OPGW)
Typical Parameters:
Double Layers
Three Layers
www.eescable.com 69
Central Al-covered stainless
steel tube OPGW
Optical Fiber Composite Overhead
Ground Wire(OPGW)
Characteristic andApplication
Al-covered Stainless Steel tube design increases the cross section of AL, to
reach a better fault current and lightning resistance performance.
Good anti-corrosion performance.
Apply to the transmission line which requires small diameter and large fault
current.
www.eescable.com 70
Central Al-covered stainless
steel tube OPGW
Optical Fiber Composite Overhead
Ground Wire(OPGW)
Typical Parameters:
Single Layer
Double Layers
www.eescable.com 71
Aluminium tube OPGW
Optical Fiber Composite Overhead
Ground Wire(OPGW)
FRP
Thermal barrier
AL-coveredlayer
Characteristic andApplication
Good anti-corrosion performance.
Material and structure are uniform, good resistance to vibration fatigue.
Short circuit current has small effect on the optical fiber transmission
properties.
Good anti-lightning performance.
www.eescable.com 72
Aluminium tube OPGW
Optical Fiber Composite Overhead
Ground Wire(OPGW)
Typical Parameters:
Single Layer
Double Layers
www.eescable.com 73
Central Type Aluminum Tube OPGW
Optical Fiber Composite Overhead Ground
Wire(OPGW)
Loosetube
Optical fibers and gel
Glassyarn
Aramid yarns
AL-coveredlayer
Characteristic andApplication
Good anti-corrosion performance.
Material and structure are uniform, good resistance to vibration fatigue.
Short circuit current has small effect on the optical fiber transmission
properties.
Good anti-lightning performance.
www.eescable.com 74
Central Type Aluminum Tube OPGW
Optical Fiber Composite Overhead Ground
Wire(OPGW)
Typical Parameters:
Single Layer
Double Layers
www.eescable.com 75
Single Conductor 600 Voltage
Aerial Bundled Cables Low Voltage
(ABC LV URD)
www.eescable.com 76
Triplex Conductor 600 Voltage
Aerial Bundled Cables Low Voltage
(ABC LV URD)
APPLICATION: Directly buried or installed in ducts for 600 volt or less secondary distribution.
CONSTRUCTION: Concentric stranded or compressed 1350-H19 aluminum conductors, cross-linked
polyethylene insulation. Insulated conductors surface printed, neutral, yellow striped. Two phase and one
neutral conductor twisted together (LH lay).
SPECIFICATIONS: ASTM B-230, B-231, B-609, B-901, ICEA S-105-692, Federal Specification A-A-59544A.
UL854.
OPTIONS: Cable in Duct (CIC) • Abrasion Resistant.
RUS ACCEPTED
Bergen 1/0 19/w 80 1/0 19/w 80 0.522 1.133 465 215 180
Hunter 2/0 19/w 80 2/0 19/w 80 0.566 1.228 560 245 180
Hollins 3/0 19/w 80 1/0 19/w 80 0.616 1.276 608 280 205
Sweetbriar 4/0 19/w 80 2/0 19/w 80 0.672 1.389 739 315 240
Monmouth 4/0 19/w 80 4/0 19/w 80 0.672 1.457 828 315 240
Pratt 250 37/w 95 3/0 19/w 80 0.748 1.538 893 345 265
Wesleyan 350 37/w 95 4/0 19/w 80 0.851 1.736 1166 415 320
Rider 500 37/w 95 350 37/w 95 0.979 2.035 1663 495 395
www.eescable.com 77
Quadruplex Conductor 600
Voltage
Aerial Bundled Cables Low Voltage
(ABC LV URD)
Windham 750 61/w 110 500 37/w 95 2.850 3147 615 492
www.eescable.com 78
800 Series Voltage
Aerial Bundled Cables Low Voltage
(ABC LV URD)
APPLICATION: Triplex Type RHH or RHW-2 or USE-2 is primarily used for secondary
distribution and underground service at 600 volts or less, either direct burial or in ducts,
where increased flexibility is needed. May also be used with conduit as specified by the NEC.
CONSTRUCTION: Type RHH or RHW-2 or USE-2 conductors are compressed stranded AA-
8000 series Aluminum Alloy insulated with cross-linked polyethylene. A triplex construction
consists of two-phase conductors and one neutral. The neutral conductor contains yellow
extruded stripes and sequential footage marks. Conductors are surface printed for
identification.
SPECIFICATIONS: Triplex Type RHH or RHW-2 or USE-2 600 volt cable meets or exceeds the
following applicable ASTM specifications: B-800 8000 Series Aluminum Alloy Wire for
Electrical Purposes • Annealed and intermediate tempers. B-801 Compressed Conductors of
8000 Series. Aluminum Alloy for Subsequent Covering or Insulations. Triplex 600 Volt
secondary UD Cable meets or exceeds all applicable requirements of S-105-682 for cross-
linked polyethylene insulated conductors, UL Standard 44 for type RHW-2, and UL Standard
854 for Type USE-2.
Sweetbriar 4/0 19/w 80 2/0 19/w 80 658 1421 709 315 240
Monmouth 4/0 19/w 80 4/0 19/w 80 658 1421 796 315 240
Pratt 250 37/w 95 3/0 19/w 80 732 1581 853 345 265
Wake
Fores
4/0 37/w 95 2/0 19/w 80 831 1795 1118 415 320
t
Wesleyan 350 37/w 95 4/0 19/w 80 831 1795 1118 415 320
www.eescable.com 79
IEC 60502
Aerial Bundled Cables Low
Voltage(ABC LV)
www.eescable.com 80
IEC 60502
Aerial Bundled Cables Low
Voltage(ABC LV)
www.eescable.com 81
AS/NZS 3560.I 0.6/I (1.2) kV
Aerial Bundled Cables Low
Voltage(ABC LV)
www.eescable.com 82
AS/NZS 3560.I 0.6/I (1.2) kV
Aerial Bundled Cables Low
Voltage(ABC LV)
www.eescable.com 83
AERIAL BUNDLED CABLES LV
www.eescable.com 84
BS 7870-5 0.6/I (1.2) kV
Aerial Bundled Cables Low
Voltage(ABC LV)
www.eescable.com 85
IEC 60502 LV/ABC 0.6/I
(1.2) kV
Aerial Bundled Cables Low Voltage(ABC LV)
AERIAL BUNDLED CABLES LV
www.eescable.com 86
IEC 60502 LV/ABC 0.6/I
(1.2) kV
Aerial Bundled Cables Low Voltage(ABC LV)
www.eescable.com 87
AERIAL BUNDLED CABLES LV
Weight
Insulati
on
Outside Rated Strength Ampacity
Thickne
CodeWord SizeAWG Strand Diameter(in) (lbs/mft) XLP POLY (Amps)XLP
ss (mils)
www.eescable.com 88
Duplex Overhead
Aluminum Conductor
Aerial Bundled Cables Low Voltage(ABC LV)
APPLICATION: To supply 120 volt aerial service for temporary service at construction sites,
outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of
75°C maximum.
CONSTRUCTION: Concentric strand or compressed 1350-H19 conductor, polyethylene or
cross-linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy neutral
messenger.
SPECIFICATIONS: Duplex service drop cable meets or exceeds the following ASTM
specifications: B-230 Aluminum Wire, 1350-H19 or electrical purposes • B-231 Aluminum
conductors, Concentric-lay-Stranded. • B-232 Aluminum conductors, Concentric-lay-
Stranded, Coated Steel Reinforced (ACSR) • B-399 Concentric-lay-Stranded, 6201-T81
Aluminum • Service Drop cable meets or exceeds all applicable requirements of ICEA S-76-
474
RUS ACCEPTED
PhaseConductors Bare Neutral Messenger Weight Per 1000 ft. (lbs) Rating(Amps)
Insulati
on Breaki
CodeWord SizeAWG Strand Thickne SizeAWG Strand ng XLP POLY XLP POLY
ss (mls) Strengt
h
AAC
Pekingese 6 SOLID 45 6 7/w 563 63.5 61.7 85 70
Bull 1/0 19/w 60 1/0 6/1 4,380 288.7 280.3 200 155
6201 ALLOYNEUTRALMESSENGER
Heeler 1/0 19/w 60 1/0 7/w 4,460 259.2 250.8 200 155
www.eescable.com 89
Triplex Overhead
Aluminum Conductor
Aerial Bundled Cables Low Voltage(ABC LV)
APPLICATION: To supply power from the utility lines to the consumer weather head. For
service at 600 volts or less (phase to phase) at a conductor temperature of 75°C
maximum for polyethylene insulation or 90°C maximum for cross-linked insulation.
CONSTRUCTION: Concentric strand or compressed 1350-H19 conductor, polyethylene or
cross-linked polyethylene insulation, concentric strand AAC, ACSR or 6201 alloy neutral
messenger.
SPECIFICATIONS: Triplex service drop cable meets or exceeds the following ASTM
specifications: B-230 Aluminum Wire, 1350-H19 for electrical purposes • B-231 Aluminum
conductors, Concentric-Lay-Stranded • B-232 Aluminum Conductors, Concentric-Lay-
Stranded, Coated Steel Reinforced (ACSR) • B-399 Concentric-Lay-Stranded, 6201-T81
Aluminum Service Drop cable meets or exceeds all applicable requirements of ICEA S-76-
474.
RUS ACCEPTED
PhaseConductor Bare Neutral Messanger Weight Per 1000 ft. (lbs) Ampacity(Amps)
Insulatio Breakin
n g
CodeWord SizeAWG Strand Thicknes SizeAWG Strand Strengt XLP POLY XLP POLY
s (mls) h (lbs)
6201 ALLOYNEUTRALMESSENGER
Minex 6 Solid 45 6 7/w 1,110 106.6 102.9 85 70
Hippa 6 7/w 45 6 7/w 1,110 107.0 105.7 85 70
Prawn 4 Solid 45 4 7/w 1,760 158.4 154.1 110 90
Barnacles 4 7/w 45 4 7/w 1,760 160.0 157.0 110 90
Shrimp 2 7/w 45 2 7/w 2,800 243.0 238.0 150 115
Gammarus 1/0 7/w 60 1/0 7/w 4,460 390.0 384.0 200 155
Leda 1/0 19/w 60 1/0 7/w 4,460 384.0 378.0 200 155
Dungeness 2/0 7/w 60 2/0 7/w 5,390 481.0 474.0 230 180
Cyclops 2/0 19/w 60 2/0 7/w 5,390 473.0 467.0 230 180
Flustra 3/0 19/w 60 3/0 7/w 6,790 596.0 589.1 260 205
Lepas 4/0 19/w 60 4/0 7/w 8,560 725.0 716.0 300 235
6201 ALLOYREDUCEDNEUTRALMESSENGER
Artemia 4 Solid 45 6 7/w 1,110 134.0 132.0 110 90
Crab 4 7/w 45 6 7/w 1,110 144.0 141.2 110 90
Solaster 2 7/w 45 4 7/w 1,760 216.0 212.6 150 115
Sandcrab 1/0 7/w 60 2 7/w 2,800 348.0 341.0 200 155
Echinus 1/0 19/w 60 2 7/w 2,800 342.0 336.0 200 155
Crayfish 2/0 7/w 60 1 7/w 3,530 452.6 422.5 230 180
Sipho 2/0 19/w 60 1 7/w 3,530 441.0 422.5 230 180
Fulgar 3/0 19/w 60 1/0 7/w 4,460 525.0 518.0 260 205
Arca 4/0 19/w 60 2/0 7/w 5,390 640.0 632.0 300 235
www.eescable.com 90
Triplex Overhead
Aluminum Conductor
Aerial Bundled Cables Low Voltage(ABC LV)
PhaseConductor Bare Neutral Messenger Weight Per 1000 ft. (lbs) Ampacity(Amps)
Insulati Breaki
on ng
CodeWord SizeAWG Strand Thickne SizeAWG Strand Strengt XLP POLY XLP POLY
ss (mils) h (lbs)
AACNEUTRALMESSENGER
Haiotis 6 Solid 45 6 7/w 563 102.5 98.8 85 70
Patella 6 7/w 45 6 7/w 563 104.0 101.6 85 70
Fusus 4 Solid 45 4 7/w 881 151.9 147.6 110 90
Oyster 4 7/w 45 4 7/w 881 154.0 151.7 110 90
Clam 2 7/w 45 2 7/w 1,350 232.0 228.0 150 115
Murex 1/0 7/w 60 1/0 7/w 1,990 374.0 367.0 200 155
Purpura 1/0 19/w 60 1/0 7/w 1,990 368.0 362.0 200 155
Nassa 2/0 7/w 60 2/0 7/w 2,510 461.0 453.0 230 180
Melita 3/0 19/w 60 3/0 19/w 3,310 585.2 562.9 260 205
Portunus 4/0 19/w 60 4/0 19/w 4,020 693.0 684.0 300 235
Nannynose 336 19/w 80 336 19/w 6,146 1111.0 1096.0 380 290
FULL SIZE ACSRMESSENGER
Paludina 6 Solid 45 6 6/1 1,190 114.0 113.0 85 70
Valuta 6 7/w 45 6 6/1 1,190 115.0 112.0 85 70
Whelk 4 Solid 45 4 6/1 1,860 163.0 161.0 110 90
Periwinkle 4 7/w 45 4 6/1 1,860 172.0 169.0 110 90
Conch 2 7/w 45 2 6/1 2,850 262.0 257.0 150 115
Neritina 1/0 7/w 60 1/0 6/1 4,380 420.0 414.0 200 155
Cenia 1/0 19/w 60 1/0 6/1 4,380 414.0 408.0 200 155
Runcina 2/0 7/w 60 2/0 6/1 5,310 519.0 512.0 230 180
Triton 2/0 19/w 60 2/0 6/1 5,310 511.0 505.0 230 180
Cherrystone 3/0 7/w 60 3/0 6/1 6,620 656.0 643.0 260 205
Mursia 3/0 19/w 60 3/0 6/1 6,620 633.0 626.0 260 205
Razor 4/0 7/w 60 4/0 6/1 8,350 814.0 799.0 300 235
Zuzara 4/0 19/w 60 4/0 6/1 8,350 785.0 777.0 300 235
Limpet 336 19/w 80 336 18/1 8,680 1161.0 1147.0 380 290
ACSRREDUCEDSIZEMESSENGER
Scallop 4 Solid 45 6 6/1 1,190 142.0 139.0 110 90
Strombus 4 7/w 45 6 6/1 1,190 151.0 148.0 110 90
Cockle 2 7/w 45 4 6/1 1,860 228.0 224.0 150 115
Janthina 1/0 7/w 60 2 6/1 2,850 367.0 360.0 200 155
Ranella 1/0 19/w 60 2 6/1 2,850 361.0 356.0 200 155
Cavolinia 2/0 7/w 60 1 6/1 3,550 452.0 444.0 230 180
Clio 2/0 19/w 60 1 6/1 3,550 444.0 437.0 230 180
Sanddollar 3/0 7/w 60 1/0 6/1 4,380 570.0 557.0 260 205
Aega 3/0 19/w 60 1/0 6/1 4,380 565.0 552.0 260 205
Cuttlefish 4/0 7/w 60 2/0 6/1 5,310 706.0 691.0 300 235
Cerapus 4/0 19/w 60 2/0 6/1 5,310 678.0 670.0 300 235
Cowry 336 19/w 80 4/0 6/1 8,350 1135.0 1093.0 380 290
www.eescable.com 91
Quadruplex Overhead
Aluminum Conductor
Aerial Bundled Cables Low Voltage(ABC LV)
APPLICATION: Used to supply 3 phase power, usually from a pole-mounted transformer, to the user’s service
head where connection to the service entrance cable is made. To be used at voltages of 600 volts or less phase to
phase and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-
linked-polyethylene (XLP) insulated conductors.
CONSTRUCTION: Conductors are concentrically stranded, compressed 1350-H19 aluminum Insulated with either
polyethylene or XLP cross-linked- polyethylene. Neutral messengers are concentrically stranded 6201, AAC, or
ACSR.
SPECIFICATIONS: Quadruplex service drop cable meets or exceeds the following ASTM specifications: B-230
Aluminum Wire, 1350-H19 for electrical purposes. B-231 Aluminum conductors, Concentric-Lay-Stranded. B-232
Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-399 Concentric-Lay-Stranded,
6201-T81 Aluminum. Service Drop cable meets or exceeds all applicable requirements of ICEA S-76-474.
RUSACCEPTED
PhaseConductors Bare Neutral Messenger Weight Per 1000 ft. (lbs) Ampacity(Amps)
Insulatio Breakin
n g
SizeAWG Strand Thicknes SizeAWG Strand Strengt XLP POLY XLP POLY
CodeWord
s (mils) h (lbs)
AAC- NEUTRALMESSENGER
Clydesdale 4 Solid 45 4 7/w 881 208 201 100 80
Pinto 4 7/w 45 4 7/w 881 223 207 100 80
Mustang 2 7/w 45 2 7/w 1,350 333 312 135 105
Griollo 1/0 19/w 60 1/0 7/w 1,990 529 504 180 135
Percheron 2/0 19/w 60 2/0 7/w 2,510 649 620 205 155
Hanoverian 3/0 19/w 60 3/0 19/w 3,310 799 765 235 180
Oldenburg 4/0 19/w 60 4/0 19/w 4,020 986 946 270 205
Lippizaner 336.4 19/w 80 336.4 19/w 6,146 1546 1,519 330 240
ACSR- NEUTRALMESSENGER
Morchuca 6 Solid 45 6 6/1 1,190 152 147 75 60
Chola 6 7/w 45 6 6/1 1,190 162 151 75 60
Morgan 4 Solid 45 4 6/1 1,860 226 220 100 80
Hackney 4 7/w 45 4 6/1 1,860 241 226 100 80
Palomino 2 7/w 45 2 6/1 2,850 362 342 135 105
Costena 1/0 19/w 60 1/0 6/1 4,380 575 550 180 135
Grullo 2/0 19/w 60 2/0 6/1 5,310 707 678 205 155
Suffolk 3/0 19/w 60 3/0 6/1 6,620 872 838 235 180
Appaloosa 4/0 19/w 60 4/0 6/1 8,350 1079 1,039 270 205
Bronco 336.4 19/w 80 336.4 18/1 8,580 1613 1,568 330 240
Gelding 336.4 19/w 80 4/0 6/1 8,350 1548 1,494 330 240
Hurricane 500 37/w 80 336.4 26/7 8,580 2196 2186 458 398
6201 - ALLOYNEUTRALMESSENGER
Bay 6 Solid 45 6 7/w 1,110 145 140 75 60
FrenchCoach 6 7/w 45 6 7/w 1,110 155 144 75 60
GermanCoach 4 Solid 45 4 7/w 1,760 214 208 100 80
Arabian 4 7/w 45 4 7/w 1,760 229 214 100 80
Belgian 2 7/w 45 2 7/w 2,800 344 323 135 105
Shetland 1/0 19/w 60 1/0 7/w 4,460 546 521 180 135
Thoroughbred 2/0 19/w 60 2/0 7/w 5,390 670 641 205 155
Trotter 3/0 19/w 60 3/0 7/w 6,790 825 791 235 180
Walking 4/0 19/w 60 4/0 7/w 8,560 1019 979 270 205
www.eescable.com 92
CAAI Y CAAI-S
Aerial Bundled Cables Low Voltage(ABC LV)
CONSTRUCCIÓN
Los conductores tipo CAAI están formados por dos o tres conductores de fase trenzados concéntricamente más uno o dos
conductores para alumbrado cableados alrededor de un soporte o portante. Los conductores de fase y de alumbrado son de
aleación de aluminio 1350-H19 de temple duro. El soporte es un cable de acero galvanizado, clase A, tipo Extra High Strengh
(EHS) para cables tipo CAAI-S y de aleación de aluminio 6201-T81 (que sirve como neutro) para los cables tipo CAAI. Los
conductores y el soporte son aislados con Polietileno Reticulado (XLPE). Los conductores de fase son diferenciados por
nervaduras extruidas longitudinalmente sobre el aislamiento. Su forma de embalaje son carretes en longitudes de acuerdo a
las necesidades del cliente.
APLICACIONES
Los conductores de aluminio tipo CAAI y CAAI-S son trenzados clases AA y A y son utilizados para líneas de distribución
secundaria de energía eléctrica, pueden ser instalados directamente enterrados, en ductos o canalizaciones eléctricas. Este
tipo de conductor puede ser utilizado en lugares secos y húmedos, su temperatura máxima de operación es 90 °C y su
tensión de servicio para todas las aplicaciones es 1 kV.
ESPECIFICACIONES
Los conductores de aluminio tipo CAAI y CAAI-S fabricados por EES CABLE., cumplen con las siguientes especificaciones y
normas:
www.eescable.com 93
CAAI
Aerial Bundled Cables Low Voltage(ABC LV)
Conductor Adicional
Conductor de Fase (Alumbrado) Conductor Neutro Soporte Aislado
Diámetro
Aprox. Cable PesoTotal Capacidad de
CABLECAAI
Sección Diámetro Sección Diámetro Sección Diámetro Carga de Total (mm) (kg /km ) Corriente (A)
(mm²) Transversal Aislado Transversal Aisla Transversal Aislado Rotura
(mm²) (mm) (mm²) (mm) (mm²) (mm) (kgf)
2 X25 +1X 16+N 25 25 8,68 16 7,40 25 8,68 805 18,39 362,42 114
2 X35 +1X 16+N 25 35 9,85 16 7,40 25 8,68 805 20,88 428,86 141
2 X50 +1X 16+N 35 50 12,19 16 7,40 35 9,85 1136 25,84 577,48 171
2 X70 +1X 16+N 50 70 13,87 16 7,40 50 12,09 1623 29,40 767,68 215
2 X95 +1X16+N 70 95 15,66 16 7,40 70 13,87 2201 33,19 992,10 265
2 X120+1X 16+N 70 120 18,28 16 7,40 70 13,87 2201 37,48 1191,69 305
3 X25 +1X 16+N 25 25 8,68 16 7,40 25 8,68 805 24,29 460,84 114
3 X35 +1X 16+N 25 35 9,85 16 7,40 25 8,68 805 27,58 560,50 141
3 X50 +1X 16+N 35 50 12,19 16 7,40 35 9,85 1136 34,13 766,90 171
3 X70 +1X 16+N 50 70 13,87 16 7,40 50 12,09 1623 38,84 1021,35 215
3 X120+1X 16+N 70 120 18,28 16 7,40 70 13,87 2201 51,20 1624,05 305
www.eescable.com 94
CAAI-S
Aerial Bundled Cables Low Voltage(ABC LV)
www.eescable.com 95
ABC SANS 1418-2009
Five-Core
Aerial Bundled Cables Low Voltage(ABC LV)
3 16 1 54.6 1 25 7 4.8 1.2 0.98 7.2 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 27.05
3 25 1 54.6 1 25 7 6.0 1.4 1.16 8.8 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 30.25
3 35 1 54.6 1 25 7 7.0 1.6 1.34 10.2 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 33.05
3 50 1 54.6 1 25 7 8.3 1.6 1.34 11.5 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 35.65
3 70 1 54.6 1 25 19 10.0 1.8 1.52 13.6 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 39.85
3 95 1 54.6 1 25 19 11.6 1.8 1.52 15.2 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 43.05
3 120 1 54.6 1 25 19 13.0 1.8 1.52 16.6 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 45.85
3 150 1 54.6 1 25 19 14.6 1.8 1.52 18.2 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 49.05
3 16 1 54.6 2 25 7 4.8 1.2 0.98 7.2 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 27.05
3 25 1 54.6 2 25 7 6.0 1.4 1.16 8.8 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 30.25
3 35 1 54.6 2 25 7 7.0 1.6 1.34 10.2 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 33.05
3 50 1 54.6 2 25 7 8.3 1.6 1.34 11.5 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 35.65
3 70 1 54.6 2 25 19 10.0 1.8 1.52 13.6 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 39.85
3 95 1 54.6 2 25 19 11.6 1.8 1.52 15.2 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 43.05
3 120 1 54.6 2 25 19 13.0 1.8 1.52 16.6 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 45.85
3 150 1 54.6 2 25 19 14.6 1.8 1.52 18.2 7 3.15 9.45 1.6 1.34 12.65 7 6.0 1.4 1.16 8.8 49.05
3 16 1 70 1 25 7 4.8 1.2 0.98 7.2 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 28.1
3 25 1 70 1 25 7 6.0 1.4 1.16 8.8 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 31.3
3 35 1 70 1 25 7 7.0 1.6 1.34 10.2 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 34.1
3 50 1 70 1 25 7 8.3 1.6 1.34 11.5 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 36.7
3 70 1 70 1 25 19 10.0 1.8 1.52 13.6 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 40.9
www.eescable.com 96
ABC SANS 1418-2009
Five-Core
Aerial Bundled Cables Low Voltage(ABC LV)
3 95 1 70 1 25 19 11.6 1.8 1.52 15.2 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 44.1
3 120 1 70 1 25 19 13.0 1.8 1.52 16.6 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 46.9
3 150 1 70 1 25 19 14.6 1.8 1.52 18.2 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 50.1
3 16 1 70 2 25 7 4.8 1.2 0.98 7.2 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 28.1
3 25 1 70 2 25 7 6.0 1.4 1.16 8.8 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 31.3
3 35 1 70 2 25 7 7.0 1.6 1.34 10.2 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 34.1
3 50 1 70 2 25 7 8.3 1.6 1.34 11.5 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 36.7
3 70 1 70 2 25 19 10.0 1.8 1.52 13.6 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 40.9
3 95 1 70 2 25 19 11.6 1.8 1.52 15.2 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 44.1
3 120 1 70 2 25 19 13.0 1.8 1.52 16.6 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 46.9
3 150 1 70 2 25 19 14.6 1.8 1.52 18.2 7 3.5 10.5 1.6 1.34 13.7 7 6.0 1.4 1.16 8.8 50.1
3 16 1 54.6 1 16 7 4.8 1.2 0.98 7.2 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 27.05
3 25 1 54.6 1 16 7 6.0 1.4 1.16 8.8 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 30.25
3 35 1 54.6 1 16 7 7.0 1.6 1.34 10.2 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 33.05
3 50 1 54.6 1 16 7 8.3 1.6 1.34 11.5 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 35.65
3 70 1 54.6 1 16 19 10.0 1.8 1.52 13.6 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 39.85
3 95 1 54.6 1 16 19 11.6 1.8 1.52 15.2 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 43.05
3 120 1 54.6 1 16 19 13.0 1.8 1.52 16.6 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 45.85
3 150 1 54.6 1 16 19 14.6 1.8 1.52 18.2 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 49.05
3 16 1 54.6 2 16 7 4.8 1.2 0.98 7.2 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 27.05
3 25 1 54.6 2 16 7 6.0 1.4 1.16 8.8 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 30.25
3 35 1 54.6 2 16 7 7.0 1.6 1.34 10.2 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 33.05
3 50 1 54.6 2 16 7 8.3 1.6 1.34 11.5 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 35.65
3 70 1 54.6 2 16 19 10.0 1.8 1.52 13.6 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 39.85
3 95 1 54.6 2 16 19 11.6 1.8 1.52 15.2 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 43.05
3 120 1 54.6 2 16 19 13.0 1.8 1.52 16.6 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 45.85
3 150 1 54.6 2 16 19 14.6 1.8 1.52 18.2 7 3.15 9.45 1.6 1.34 12.65 7 4.8 1.2 0.98 7.2 49.05
3 16 1 70 1 16 7 4.8 1.2 0.98 7.2 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 27.9
3 25 1 70 1 16 7 6.0 1.4 1.16 8.8 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 31.1
3 35 1 70 1 16 7 7.0 1.6 1.34 10.2 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 33.9
3 50 1 70 1 16 7 8.3 1.6 1.34 11.5 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 36.5
3 70 1 70 1 16 19 10.0 1.8 1.52 13.6 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 40.7
3 95 1 70 1 16 19 11.6 1.8 1.52 15.2 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 43.9
3 120 1 70 1 16 19 13.0 1.8 1.52 16.6 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 46.7
3 150 1 70 1 16 19 14.6 1.8 1.52 18.2 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 49.9
3 16 1 70 2 16 7 4.8 1.2 0.98 7.2 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 27.9
3 25 1 70 2 16 7 6.0 1.4 1.16 8.8 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 31.1
3 35 1 70 2 16 7 7.0 1.6 1.34 10.2 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 33.9
3 50 1 70 2 16 7 8.3 1.6 1.34 11.5 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 36.5
3 70 1 70 2 16 19 10.0 1.8 1.52 13.6 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 40.7
3 95 1 70 2 16 19 11.6 1.8 1.52 15.2 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 43.9
3 120 1 70 2 16 19 13.0 1.8 1.52 16.6 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 46.7
3 150 1 70 2 16 19 14.6 1.8 1.52 18.2 7 3.5 10.5 1.5 1.25 13.5 7 4.8 1.2 0.98 7.2 49.9
www.eescable.com 97
ABC SANS 1418-2009
Four-Core
Aerial Bundled Cables Low Voltage(ABC LV)
3 35 1 54.6 7 7.0 1.6 1.3 10.2 7 3.1 9.45 1.6 1.34 12.6 26.17 4.5 16.6 0.868 0.63
4 5 5
3 50 1 54.6 7 8.3 1.6 1.3 11.5 7 3.1 9.45 1.6 1.34 12.6 28.53 6.2 16.6 0.641 0.63
4 5 5
3 70 1 54.6 19 10.0 1.8 1.5 13.6 7 3.1 9.45 1.6 1.34 12.6 32.34 8.9 16.6 0.443 0.63
2 5 5
3 95 1 54.6 19 11.6 1.8 1.5 15.2 7 3.1 9.45 1.6 1.34 12.6 35.24 12.3 16.6 0.320 0.63
2 5 5
3 120 1 54.6 19 13.0 1.8 1.5 16.6 7 3.1 9.45 1.6 1.34 12.6 37.78 15.6 16.6 0.253 0.63
2 5 5
3 150 1 54.6 19 14.6 1.8 1.5 18.2 7 3.1 9.45 1.6 1.34 12.6 40.69 19.2 16.6 0.206 0.63
2 5 5
3 16 1 70 7 4.8 1.2 0.9 7.2 7 3.5 10.5 1.6 1.34 13.7 21.36 2.07 20.1 1.91 0.50
8
3 25 1 70 7 6.0 1.4 1.1 8.8 7 3.5 10.5 1.6 1.34 13.7 24.26 3.3 20.1 1.20 0.50
6
3 35 1 70 7 7.0 1.6 1.3 10.2 7 3.5 10.5 1.6 1.34 13.7 26.8 4.5 20.1 0.868 0.50
4
3 50 1 70 7 8.3 1.6 1.3 11.5 7 3.5 10.5 1.6 1.34 13.7 29.16 6.2 20.1 0.641 0.50
4
3 70 1 70 19 10.0 1.8 1.5 13.6 7 3.5 10.5 1.6 1.34 13.7 32.97 8.9 20.1 0.443 0.50
2
3 95 1 70 19 11.6 1.8 1.5 15.2 7 3.5 10.5 1.6 1.34 13.7 35.88 12.3 20.1 0.320 0.50
2
3 120 1 70 19 13.0 1.8 1.5 16.6 7 3.5 10.5 1.6 1.34 13.7 38.42 15.6 20.1 0.253 0.50
2
3 150 1 70 19 14.6 1.8 1.5 18.2 7 3.5 10.5 1.6 1.34 13.7 41.32 19.2 20.1 0.206 0.50
2
One to Four core ABC cable without neutral and lighting conductor.
www.eescable.com 98
ABC SANS 1418-2009
1-4 Core ABC Cable without Neutral
and Lighting Conductor
Aerial Bundled Cables Low Voltage(ABC LV)
www.eescable.com 99
IEC 60502 & TNB
Aerial Bundled Cables Medium Voltage
(ABC MV)
www.eescable.com 100
IEC 60502 & TNB
Aerial Bundled Cables Medium Voltage
(ABC MV)
www.eescable.com 101
IEC 60502 & TNB
Aerial Bundled Cables Medium Voltage
(ABC MV)
www.eescable.com 102
AS/NZS 3599.1
Aerial Bundled Cables Medium Voltage
(ABC MV)
www.eescable.com 103
AS/NZS 3599.1
Aerial Bundled Cables Medium Voltage
(ABC MV)
www.eescable.com 104
AS/NZS 3599.1
Aerial Bundled Cables Medium Voltage
(ABC MV)
www.eescable.com 105
AS/NZS 3599.2
Aerial Bundled Cables Medium Voltage
(ABC MV)
www.eescable.com 106
AS/NZS 3599.2
Aerial Bundled Cables Medium Voltage
(ABC MV)
www.eescable.com 107
FIRE RESISTANT CABLES N2XB
(AL)Y 1 x (16-800) mm² 0.6/1 kV
N2XBY-FR CU XLPE PVC with
Double ATA Armor
(Copper Conductor, Mica Tape, XLPE Insulated, Double Aluminium Tape Armor, PVC Sheathed)
Standard Specification : IEC 60502-1 and IEC 60331
Construction Data
Application : Copper Conductor
Nom. Overall Cable
For wiring of fire resistant safety circuits, such
Cross Diameter Weight as fire alarm system, emergency lighting and
Mica Tape
Section power, public address and emergency voice
Area approx. approx. communication systems in highrise building,
XLPE Insulation
Electrical Data
Conductor Inductance Current - Carrying Capacity at 30° C *
Short circuit
Nom. DC AC Trefoil Flat
formatio formatio current at 1
Cross Resistance Resistance in air in ground in air in ground
Sect. at 20°C at 90°C n n sec
www.eescable.com 108
FIRE RESISTANT CABLES N2XBY
2 x (1.5-300) mm² 0.6/1 kV
N2XBY-FR CU XLPE PVC with
Double STA Armor
(Copper Conductor, Mica Tape, XLPE Insulated, Double Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-1 and IEC 60331
Construction Data
Application : Copper
Nom. Overall Cable
For wiring of fire resistant safety circuits, Conductor
Cross Diameter Weight such as fire alarm system, emergency Mica Tape
Section lighting and power, public address and
approx. approx. XLPE Insulation
Area emergency voice communication systems in
PVC Inner Sheath
mm kg/km highrise building, control and
mm²
instrumentation services in industrial,
1.5 15.6 336 Double Galvanized Steel Tape
commercial and residential complexes.
Armor
Special Features on Request :
2.5 16.5 387
• Oil Resistance
PVC Sheath
4 17.6 456 • UV Resistance
• Flame Retardant Cat. A, B, C
6 19.1 543 • Flame Retardant Non
10 21.0 694 Category
• Anti Termite
16 22.5 831 • Anti Rodent
• Low Smoke Zero Halogen
25 25.5 1,130
35 27.5 1,408
Note :
50 30.5 1,738 Conductor Shape
70 35.0 2,386 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded
(rm) conductor shape
95 39.5 3,391 16 sqmm supplied in non compacted circular stranded (rm) conductor
shape 25 - 300 sqmm supplied in compacted circular stranded (cm)
120 43.5 4,056 conductor shape
150 48.5 4,964
Standard Packing
185 53.0 5,944 1.5 - 95 sqmm supplied in wooden drum @ 1000 m
240 58.5 7,407 120 - 300 sqmm will be suplied in wooden drum on available
length Length Tolerance per drum ± 2%
300 64.0 9,001
Electrical Data
Conductor Inductance Current - Carrying
Nom. DC AC Capacity at
30°C * Max.
Cross Resistance Resistance (kA)
in air in ground
Sect. at 20°C at 90°C
Max. Max.
Max. Max. (A) (A)
(mm²) (mH/km)
(Ω/km) (Ω/km)
1.5 12.1 15.429 0.315 29 34 0.21
2.5 7.41 9.449 0.293 39 45 0.36
4 4.61 5.878 0.275 51 59 0.57
6 3.08 3.927 0.263 65 74 0.86
10 1.83 2.334 0.248 89 100 1.43
16 1.15 1.466 0.238 118 130 2.29
25 0.727 0.927 0.240 157 167 3.58
35 0.524 0.668 0.233 193 201 5.01
50 0.387 0.494 0.232 233 239 7.15
70 0.268 0.342 0.229 295 293 10.01
95 0.193 0.247 0.224 360 350 13.59
120 0.153 0.196 0.223 423 401 17.16
150 0.124 0.160 0.224 482 449 21.45
185 0.0991 0.128 0.225 551 505 26.46
240 0.0754 0.099 0.223 652 584 34.32
300 0.0601 0.080 0.221 744 656 42.90
www.eescable.com 109
FIRE RESISTANT CABLES N2XBY
3 x (1.5-300) mm² 0.6/1 kV
N2XBY-FR CU XLPE PVC with
Double STA Armor
(Copper Conductor, Mica Tape, XLPE Insulated, Double Galvanized Steel Tape Armor, PVC Sheathed)
Standard Specification : IEC 60502-1 and IEC 60331
Construction Data
Application : Copper Conductor
Nom. Overall Cable For wiring of fire resistant safety circuits, Mica Tape
Cross Diameter Weight such as fire alarm system, emergency
XLPE Insulation
Section lighting and power, public address and
Area approx. approx. emergency voice communication systems
PVC Inner Sheath
in highrise building, control and
mm² mm kg/km instrumentation services in industrial, Double Galvanized Steel Tape
1.5 16.3 371 commercial and residential complexes. Armor
2.5 17.3 433 Special Features on Request
4 18.5 517 • Oil Resistance PVC Sheath
6 20.5 624 • UV Resistance
• Flame Retardant Cat. A, B, C
10 22.5 813
• Flame Retardant Non Category
16 23.5 998
• Anti Termite
25 27.0 1,382
• Anti Rodent
35 29.5 1,745 • Low Smoke Zero Halogen
50 32.5 2,168
70 38.5 3,346 Note :
Conductor Shape
95 42.0 4,251
1.5 - 10 sqmm supplied in solid (re) or non compacted circular
120 46.0 5,122 stranded (rm) conductor shape
150 51.5 6,268 16 sqmm supplied in non compacted circular stranded (rm) conductor
185 56.5 7,573 shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
240 62.5 9,633
Standard Packing
300 68.5 11,670 1.5 - 70 sqmm supplied in wooden drum @ 1000 m
95 - 300 sqmm will be suplied in wooden drum on available
length Length Tolerance per drum ± 2%
Electrical Data
Conductor
Current – Carrying Short circuit
DC AC Inductance Capacityat 30°C * current at 1
Nom.
Cross Resistance Resistance
in air in ground
sec
Sect. at 20°C at 90°C
www.eescable.com 110
FIRE RESISTANT CABLES N2XBY
4 x (1.5-300) mm² 0.6/1 kV
N2XBY-FR CU XLPE PVC with
Double STA Armor
(Copper Conductor, Mica Tape, XLPE Insulated, Double Galvanized Steel Tape Armor, PVC Sheathed)
Standard Specification : IEC 60502-1 and IEC 60331
Construction Data
Application : Copper Conductor
Nom. Overall Cable
For wiring of fire resistant safety circuits,
Cross Diameter Weight Mica Tape
such as fire alarm system, emergency
Section lighting and power, public address and XLPE Insulation
Area approx. approx. emergency voice communication systems in
highrise building, control and PVC Inner Sheath
mm² mm kg/km
instrumentation services in industrial,
1.5 17.6 423 commercial and residential complexes. Double Galvanized Steel Tape
Armor
2.5 18.7 499 Special Features on Request :
• Oil Resistance
4 20.0 603 • UV Resistance PVC Sheath
Electrical Data
Conductor Inductance Current - Carrying
Capacity Short circuit
Nom. DC AC
Cross at 30°C* current at 1
Resistance Resistance
Sect.
at20°C at90°C inair inground
sec
www.eescable.com 111
FIRE RESISTANT CABLES N2XY 1 x
(1.5-800) mm2 0.6/1 kV
N2XY-FR CU XLPE PVC without armor
(Copper Conductor, Mica Tape, XLPE Insulated, PVC Sheathed) Standard Specification : IEC
60502-1 and IEC 60331
Construction Data
Application :
Nom. Cross Overall Cable Weight For wiring of fire resistant safety circuits, Copper Conductor
Section Area Diameter such as fire alarm system, emergency
Mica Tape
lighting and power, public address and
approx. approx. emergency voice communication systems XLPE Insulation
in highrise building, control and
mm² mm kg/km instrumentation services in industrial,
commercial and residential complexes.
1.5 6.8 58
Special Features on Request
2.5 7.2 72 PVC Sheath
• Oil Resistance
4 7.8 92 • UV Resistance
6 8.4 115 • Flame Retardant Cat. A, B, C
10 9.4 162 • Flame Retardant Non
16 10.4 222 Category
• Heat Resistance
25 12.2 332
• Anti Termite
35 13.3 427 • Anti Rodent
50 15.0 576 • Low Smoke Zero Halogen
70 16.9 782 • Nylon Coated
95 18.9 1,030
120 21.0 1,274 Note :
150 23.0 1,550 Conductor Shape
185 25.5 1,951 1.5 - 10 sqmm supplied in solid (re) or non compacted circular
240 29.0 2,543 stranded (rm) conductor shape
300 31.5 3,080 16 sqmm supplied in non compacted circular stranded (rm) conductor
shape 25 - 800 sqmm supplied in non compacted circular stranded (rm)
400 35.0 3,935
or compacted circular stranded (cm) conductor shape
500 39.5 5,025
630 44.0 6,526 Standard Packing
800 49.0 8,181 1.5 - 10 sqmm supplied in coil @ 100 m
16 - 400 sqmm supplied in wooden drum @ 1000 m
500 - 800 sqmm supplied in wooden drum on available
Electrical Data length Length Tolerance per drum ± 2%
(mm²) Max. Max. (mH/km) (mH/km) Max. Max. Max. Max. Max.(kA)
(Ω/km) (Ω/km) (A) (A) (A) (A)
1.5 12.1 15.429 0.478 0.524 25 33 26 33 0.21
2.5 7.41 9.449 0.441 0.487 34 43 35 43 0.36
4 4.61 5.878 0.409 0.455 45 56 46 55 0.57
6 3.08 3.927 0.387 0.433 57 69 58 68 0.86
10 1.83 2.333 0.356 0.402 78 92 80 91 1.43
16 1.15 1.466 0.333 0.379 104 118 107 117 2.29
25 0.727 0.927 0.317 0.363 141 152 145 151 3.58
35 0.524 0.668 0.303 0.349 173 182 178 180 5.01
50 0.387 0.494 0.290 0.336 213 216 220 214 7.15
70 0.268 0.342 0.280 0.326 271 265 279 261 10.01
95 0.193 0.247 0.272 0.318 335 316 346 312 13.59
120 0.153 0.196 0.268 0.314 392 359 404 355 17.16
150 0.124 0.160 0.267 0.313 451 403 466 397 21.45
185 0.0991 0.128 0.265 0.311 526 455 543 449 26.46
240 0.0754 0.099 0.260 0.306 630 527 650 519 34.32
300 0.0601 0.080 0.255 0.301 728 593 751 584 42.90
400 0.0470 0.064 0.254 0.300 848 671 875 660 57.20
500 0.0366 0.052 0.251 0.297 985 757 1018 744 71.50
630 0.0283 0.043 0.247 0.293 1141 849 1179 834 90.09
800 0.0221 0.036 0.244 0.291 1295 937 1339 921 114.40
www.eescable.com 112
FIRE RESISTANT CABLES N2XY 2 x
(1.5-300) mm2 0.6/1 kV
N2XY-FR CU XLPE PVC without armor
(Copper Conductor, Mica Tape, XLPE Insulated, PVC Sheathed) Standard Specification : IEC 60502-1
and IEC 60331
Construction Data
Copper Conductor
Application :
Nom. Cross Overall For wiring of fire resistant safety circuits, such Mica Tape
Cable Weight
Section Diameter as fire alarm system, emergency lighting XLPE Insulation
and power, public address and emergency
Area
approx. approx. voice communication systems in highrise PVC Inner Sheath
building, control and instrumentation services
mm² mm kg/km in industrial, commercial and residential
complexes.
Special Features on Request PVC Sheath
1.5 14.5 255 • Oil Resistance
2.5 15.5 301 • UV Resistance
4 16.6 363 • Flame Retardant Cat. A, B, C
6 18.0 441 • Flame Retardant Non Category
10 19.9 582 • Anti Termite
16 22.0 758 • Anti Rodent
25 25.0 1,050 • Low Smoke Zero Halogen
• Nylon Coated
35 27.5 1,324
50 30.0 1,626
Note :
70 34.5 2,248
Conductor Shape
95 38.0 2,873
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
120 41.5 3,486 16 sqmm supplied in non compacted circular stranded (rm) conductor shape 25 - 300 sqmm
150 46.5 4,337 supplied in compacted circular stranded (cm) conductor shape
185 51.0 5,256 Standard Packing
240 56.5 6,644 1.5 - 120 sqmm supplied in wooden drum @ 1000 m
300 62.5 8,207 150 - 300 sqmm will be suplied in wooden drum on available length Length Tolerance per
drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying
Capacity Short circuit
Nom. DC AC
at 30°C * current at 1
Cross Resistance Resistance
Sect. at 20°C at 90°C in air in ground sec
www.eescable.com 113
FIRE RESISTANT CABLES N2XY 3 x
(1.5-300) mm² 0.6/1 kV
N2XY-FR CU XLPE PVC without armor
(Copper Conductor, Mica Tape, XLPE Insulated, PVC Sheathed) Standard Specification : IEC 60502-1
and IEC 60331
Construction Data
Copper Conductor
Overall Application :
Mica Tape
Nom. Cross Cable Weight
Diameter For wiring of fire resistant safety circuits, such as XLPE Insulation
Section Area fire alarm system, emergency lighting and
approx. approx. power, public address and emergency voice
PVC Inner Sheath
communication systems in highrise building,
mm² mm kg/km control and instrumentation services in industrial,
commercial and residential complexes.
Special Features on Request PVC Sheath
1.5 15.2 282 • Oil Resistance
2.5 16.2 338 • UV Resistance
4 17.4 415 • Flame Retardant Cat. A, B, C
6 18.9 511 • Flame Retardant Non Category
10 21.0 689 • Anti Termite
16 23.5 915 • Anti Rodent
25 26.5 1,289 • Low Smoke Zero Halogen
35 29.0 1,646 • Nylon Coated
50 32.0 2,039
70 37.0 2,828 Note :
95 40.5 3,682 Conductor Shape
120 44.5 4,496 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape 25 - 300 sqmm
150 50.0 5,575
supplied in compacted circular stranded (cm) conductor shape
185 54.5 6,814
Standard Packing
240 61.0 8,794 1.5 - 95 sqmm supplied in wooden drum @ 1000 m
300 66.5 10,755 120 - 300 sqmm will be suplied in wooden drum on available length Length Tolerance per drum
± 2%
Electrical Data
Conductor Inductance Current - Carrying
Capacity at 30°C * Short circuit
Nom. DC AC
Cross Resistance Resistance current at 1
Sect. at 20°C at 90°C in air in ground
sec
www.eescable.com 114
FIRE RESISTANT CABLES N2XY 4 x
(1.5-300) mm 0.6/1 kV
N2XY-FR CU XLPE PVC without armor
(Copper Conductor, Mica Tape, XLPE Insulated, PVC Sheathed) Standard Specification : IEC 60502-1
and IEC 60331
Construction Data
Application : Copper Conductor
Overall For wiring of fire resistant safety circuits, such as fire
Nom. Cross Cable Weight Mica Tape
Diameter alarm system, emergency lighting and power,
Section Area public address and emergency voice XLPE Insulation
approx. approx. communication systems in highrise building,
control and instrumentation services in industrial, PVC Inner Sheath
mm² mm kg/km commercial and residential complexes.
Special Features on Request
1.5 15.2 282 • Oil Resistance PVC Sheath
2.5 16.2 338 • UV Resistance
4 17.4 415 • Flame Retardant Cat. A, B, C
6 18.9 511 • Flame Retardant Non Category
10 21.0 689 • Anti Termite
16 23.5 915 • Anti Rodent
25 26.5 1,289 • Low Smoke Zero Halogen
35 29.0 1,646 • Nylon Coated
50 32.0 2,039
70 37.0 2,828 Note :
95 40.5 3,682 Conductor Shape
120 44.5 4,496 1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm) conductor shape
150 50.0 5,575 16 sqmm supplied in non compacted circular stranded (rm) conductor shape 25 - 300 sqmm supplied
185 54.5 6,814 in compacted circular stranded (cm) conductor shape
240 61.0 8,794 Standard Packing
300 66.5 10,755 1.5 - 95 sqmm supplied in wooden drum @ 1000 m
120 - 300 sqmm will be suplied in wooden drum on available length Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying
Short circuit
Nom. DC AC Capacity
Cross
at 30°C * current at 1
Resistance Resistance
Sect. at 20°C at 90°C in air in ground sec
www.eescable.com 115
NYR(AL)Y 1 x (10-500)
mm² 0.6/1 kV
NYRY-CU PVC PVC with AWA Armor Cu / PVC / AWA / PVC
www.eescable.com 116
NYRGbY 2 x (1.5-300)
mm² 0.6/1 kV
NYRY-CU PVC PVC with SWA Armor
www.eescable.com 117
NYRGbY 3 x (1.5-300)
mm² 0.6/1 kV
NYRY-CU PVC PVC with SWA Armor
www.eescable.com 118
NYRGbY 4 x (1.5-300)
mm² 0.6/1 kV
NYRY-CU PVC PVC with SWA Armor
www.eescable.com 119
NYRGbY 5 x (1.5-50)
mm² 0.6/1 kV
NYRY-CU PVC PVC with SWA Armor
Cu / PVC / SWA / PVC
www.eescable.com 120
NYY 1 x (1.5-800)
mm² 0.6/1 kV
NYY(CU PVC PVC)
(Copper Conductor, PVC Insulated, PVC Sheathed) Standard Specification : IEC 60502-1
Construction Data
Application :
Nom. Overall Cable
Power cable : Indoors, cable trunking, outdoors
Cross Diameter Weight and burried in the ground, for power stations, Copper Conductor
Section industry and switchgear as well as for urban
Area approx. approx. supply networks, if mechanical damage is PVC Insulation
mm² mm kg/km unlikely.
Electrical Data
Conductor Inductance Current - Carrying Capacity at 30° C *
Short circuit
Nom. DC AC Trefoil Flat
Cross Resistance Resistance formation formation current at 1
inair inground inair inground
Sect. at20°C at70°C
sec
Max. Max. Max. Max. Max. Max.
(mm²) (Ω/km) (Ω/km) (mH/km) (mH/km) (A) (A) (A) (A) Max.(kA)
1.5 12.1 14.478 0.459 0.505 21 27 21 27 0.17
2.5 7.41 8.866 0.423 0.470 27 35 28 35 0.29
4 4.61 5.516 0.404 0.450 37 46 38 45 0.46
6 3.08 3.685 0.380 0.426 46 57 48 57 0.69
10 1.83 2.190 0.350 0.396 64 76 65 76 1.15
16 1.15 1.376 0.327 0.374 84 98 87 97 1.84
25 0.727 0.870 0.312 0.358 114 127 117 125 2.88
35 0.524 0.627 0.299 0.345 140 152 144 150 4.03
50 0.387 0.464 0.290 0.336 172 180 177 178 5.75
70 0.268 0.321 0.280 0.326 218 220 225 218 8.05
95 0.193 0.232 0.274 0.321 270 264 278 260 10.93
120 0.153 0.184 0.269 0.315 315 300 325 296 13.80
150 0.124 0.150 0.266 0.313 362 336 373 331 17.25
185 0.0991 0.121 0.264 0.310 420 379 433 374 21.28
240 0.0754 0.093 0.261 0.307 503 439 518 432 27.60
300 0.0601 0.075 0.258 0.305 580 494 598 486 34.50
400 0.0470 0.061 0.256 0.302 674 558 695 549 41.20
500 0.0366 0.049 0.252 0.299 781 629 806 618 51.50
630 0.0283 0.041 0.247 0.293 901 704 930 692 64.89
800 0.0221 0.035 0.242 0.289 1018 775 1052 762 82.40
www.eescable.com 121
NYY 2 x (1.5-300)
mm² 0.6/1 kV
NYY(CU PVC PVC)
(Copper Conductor, PVC Insulated, PVC Sheathed) Standard Specification : IEC 60502-1
Construction Data
Application :
Nom. Overall Cable Copper Conductor
Power cable : Indoors, cable trunking, outdoors
Cross Diameter Weight and burried in the ground, for power stations,
Section industry and switchgear as well as for urban PVC Insulation
Area approx. approx. supply networks, if mechanical damage is
mm² mm kg/km unlikely. PVC Inner Sheath
Electrical Data
Conductor Inductance Current - Carrying
Short circuit
Nom. DC AC Capacity
Cross
at 30°C* current at 1
Resistance Resistance
Sect. at20°C at70°C inair inground sec
www.eescable.com 122
NYY 3 x (1.5-400)
mm² 0.6/1 kV
NYY(CU PVC PVC)
(Copper Conductor, PVC Insulated, PVC Sheathed). Standard Specification : IEC 60502-1\
Construction Data
Application :
Nom. Overall Cable
Power cable : Indoors, cable trunking, outdoors Copper Conductor
Cross Diameter Weight and burried in the ground, for power stations,
Section industry and switchgear as well as for urban
Area approx. approx. supply networks, if mechanical damage is
PVC Insulation
Electrical Data
Conductor Inductance Current - Carrying
Short circuit
Nom. DC AC Capacity
Cross
at 30°C* current at 1
Resistance Resistance
Sect. at20°C at70°C inair inground sec
www.eescable.com 123
NYY 4 x (1.5-400)
mm² 0.6/1 kV
NYY(CU PVC PVC)
(Copper Conductor, PVC Insulated, PVC Sheathed) Standard Specification : IEC 60502-1
Construction Data
Application :
Nom. Overall Cable
Power cable : Indoors, cable trunking, outdoors
Cross Diameter Weight and burried in the ground, for power stations,
Copper Conductor
Section industry and switchgear as well as for urban
Area approx. approx. supply networks, if mechanical damage is
PVC Insulation
Electrical Data
Conductor Inductance Current -
Carrying Short circuit
Nom. DC AC
Capacity current at 1
Cros Resistance Resistance
at 30°C *
s at 20°C at 70°C in air in ground sec
Sect.
Max. Max.
Max. Max.
(Ω/km) (Ω/km) (A) (A) Max.(kA)
(mH/km)
(mm²)
1.5 12.1 14.478 0.328 22 27 0.17
2.5 7.41 8.866 0.304 29 35 0.29
4 4.61 5.516 0.303 39 46 0.46
6 3.08 3.685 0.288 50 57 0.69
10 1.83 2.190 0.269 68 77 1.15
16 1.15 1.376 0.255 90 99 1.84
25 0.727 0.870 0.255 121 128 2.88
35 0.524 0.627 0.246 149 154 4.03
50 0.387 0.464 0.247 173 173 5.75
70 0.268 0.321 0.238 215 212 8.05
95 0.193 0.232 0.238 266 255 10.93
120 0.153 0.184 0.233 308 289 13.80
150 0.124 0.150 0.233 357 327 17.25
185 0.0991 0.121 0.233 405 366 21.28
240 0.0754 0.093 0.232 482 425 27.60
300 0.0601 0.075 0.231 552 479 34.50
400 0.0470 0.060 0.229 643 545 41.20
www.eescable.com 124
NYY 5 x (1.5-50) mm²
0.6/1 kV
NYY(CU PVC PVC)
(Copper Conductor, PVC Insulated, PVC Sheathed) Standard Specification : IEC 60502-1
Construction Data
Application :
Nom. Overall Cable PVC Filler
Power cable : Indoors, cable trunking, outdoors
Cross Diameter Weight and burried in the ground, for power stations, Copper Conductor
Section industry and switchgear as well as for urban
Area approx. approx. supply networks, if mechanical damage is PVC Insulation
35 33.0 2,478
50 38.0 3,161
Note :
Conductor Shape
1.5 - 10 sqmm supplied in solid (re) or non compacted circular stranded (rm)
conductor shape
16 sqmm supplied in non compacted circular stranded (rm) conductor shape
25 - 50 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
1.5 - 50 sqmm supplied in wooden drum @ 1000 m
Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying
Capacity Short circuit
Nom. DC AC
at 30°C*
Cross Resistance Resistance current at 1
Sect. at20°C at70°C inair inground sec
www.eescable.com 125
Pairs x 1.5 mm² &(1-50) Pairs
x 2.5 mm² 300/500 V
RE2YRY-Instrument cable with SWA
armor, PE insulated
(Copper Conductor, PE Insulated, Collective Screen, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : BS 5308-1 & IEC 60502
Construction Data
Size Application :
Copper Conductor
Instrumentation cables are suitable for
1.5mm 2 2.5mm 2 PE Insulation
No. industrial control system as needed in
of Overall Cable Overall Cable measurement, control, signalling and
pairs Diameter Weight Diameter Weight
data system technology.
Tinned Copper -
approx. approx. approx. approx. Drain Wires
mm kg/km mm kg/km Collective Screen
1 12.7 302 14.7 398 Special Features on Request PVC Inner Sheath
2 15.5 410 18.6 629 • Fire Resistance
Galvanized Steel Wire Armor
• Oil Resistance
3 19.1 632 21.0 745 Non-hygroscopic Tape
• UV Resistance
4 21.0 720 23.5 993
• Flame Retardant Cat. A, B, C
5 22.5 826 25.5 1,152 • Flame Retardant Non Category
PVC Sheath
Electrical Data
Conductor Insulation
AC
Nominal Mutual
Resistance Resistance at Voltage
Cross Capacitance Test
Section at 20°C 20°C
www.eescable.com 126
Pairs x 1.5 mm² & (2-50)
Pairs x 2.5 mm² 300/500 V
RE2YRY-Instrument cable with SWA
armor, PE insulated
(Copper Conductor, PE Insulated, Individual Screen, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : BS 5308-1 & IEC 60502
Construction Data
Electrical Data
Conductor Insulation
AC
Nominal Mutual
Voltage
Cross Resistance at Resistance at Capacitance
Test
Section 20°C 20°C
max. min. max. -
mm2 ohm/km G.ohm.km pF/m volt/1min
1.5 12.3 5 120 1000
2.5 7.56 5 120 1000
www.eescable.com 127
Pairs x 1.5 mm² & (1-50)
Pairs x 2.5 mm² 300/500 V
RE2YY-Instrument cable without
armor, PE Insulated
Construction Data
Size Application :
Copper Conductor
Instrumentation cables are suitable for
1.5mm2 2.5mm2
No. industrial control system as needed in
of Overall Cable Overall Cable measurement, control, signalling and PEInsulation
pairs Diameter Weight Diameter Weight
data system technology.
approx. approx. approx. approx.
Tinned Copper -
mm kg/km mm kg/km Drain Wires
1 7.7 89 10.5 157 Special Features on Request
Collective Screen
2 10.4 137 14.0 234 • Fire Resistance
• Oil Resistance
3 12.9 186 16.0 289 PVC Sheath
• UV Resistance
4 14.5 233 18.0 363
• Flame Retardant Cat. A, B, C
5 15.8 298 19.5 464
• Flame Retardant Non Category
6 17.2 340 21.0 520 • Heat Resistance
7 18.4 374 22.5 576 • Anti Termite
9 20.5 462 25.5 725 • Anti Rodent
10 21.5 506 26.5 806 • Low Smoke Zero Halogen
12 24.0 612 29.0 945 • Nylon Coated
14 25.5 699 31.0 1,095
15 26.0 761 32.0 1,192
Note :
16 27.0 803 33.0 1,260
Conductor Shape
18 28.5 870 35.0 1,380 All construction supplied in solid (re) or non compacted circular
19 29.0 913 35.5 1,448 stranded (rm)
20 29.5 974 36.5 1,561 Standard Packing
24 32.5 1,151 40.0 1,829 Size 1.5 mm² :
30 36.0 1,402 44.5 2,250 All conductor supplied in wooden drum @ 1000 m
Size 2.5 mm² :
36 39.5 1,714 48.5 2,692 1 - 36 pairs supplied in wooden drum @ 1000 m
40 41.5 1,882 51.0 2,981 40 - 50 pairs supplied in wooden drum on available length
48 45.0 2,214 56.0 3,561 Length tolerance per drum ± 2%
Size of drain wire : 0.5 mm²
50 46.0 2,296 57.0 3,694
Electrical Data
Conductor Insulation
AC
Mutual
Nominal Voltage
Capacitance
Cross Resistance Resistance Test
Section at 20°C at 20°C
www.eescable.com 128
Pairs x 1.5 mm2 & (2-50)
Pairs x 2.5 mm2 300/500 V
RE2YY-Instrument cable without
armor, PE Insulated
Construction Data
Size Application : Copper Conductor
Instrumentation cables are suitable for PE Insulation
1.5mm 2 2.5mm 2
No. industrial control system as needed in Tinned Copper -
of Overall Cable Overall Cable measurement, control, signalling and Drain Wires
pairs Diameter Weight Diameter Weight
data system technology.
approx. approx. approx. approx. Individual Screen
mm kg/km mm kg/km
Special Features on Request Tinned Copper -
2 12.6 244 15.4 362 Drain Wires
• Fire Resistance
3 13.6 287 16.4 419 Collective Screen
• Oil Resistance
4 14.9 339 17.9 496
• UV Resistance PVC Sheath
5 16.3 345 19.6 506
• Flame Retardant Cat. A, B, C
6 19.1 442 23.0 624 • Flame Retardant Non Category
7 19.1 457 23.0 646 • Heat Resistance
9 23.0 576 27.5 830 • Anti Termite
10 24.5 633 29.5 927 • Anti Rodent
12 27.5 767 32.5 1,092 • Low Smoke Zero Halogen
14 28.5 869 34.0 1,258 • Nylon Coated
15 30.0 946 36.0 1,370
16 31.5 1,008 38.0 1,459
Note :
18 33.5 1,095 40.0 1,606 Conductor Shape
19 33.5 1,141 40.0 1,675 All construction supplied in solid or non compacted circular stranded
20 35.0 1,271 42.5 1,886
Standard Packing
24 41.5 1,492 50.0 2,168 Size 1.5 mm² :
30 44.0 1,792 53.5 2,640 2 - 36 pairs supplied in wooden drum @ 1000 m
40 - 50 pairs supplied in wooden drum on available length
36 48.5 2,161 58.0 3,158
Size 2.5 mm² :
40 50.0 2,366 61.0 3,490 2 - 20 pairs supplied in wooden drum @ 1000 m
48 55.5 2,795 68.0 4,189 24 - 50 pairs supplied in wooden drum on available length
Length tolerance per drum ± 2%
50 57.0 2,900 69.5 4,347
Size of drain wire : 0.5 mm²
Electrical Data
Conductor Insulation
AC
Nominal Mutual Voltage
Cross Resistance at Resistance at Capacitance Test
Section 20°C 20°C
www.eescable.com 129
Pairs x 1.5 mm² & (1-50)
Pairs x 2.5 mm² 300/500 V
REYRY-Instrument cable with SWA
armor, PVC insulated
(Copper Conductor, PVC Insulated, Collective Screen, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : BS 5308-2 & IEC 60502
Construction Data
Electrical Data
Conductor Insulation
AC
Mutual
Nominal Voltage
Capacitance
Cross Resistance at Resistance at Test
Section 20°C 20°C
www.eescable.com 130
Pairs x 1.5 mm² & (2-50)
Pairs x 2.5 mm² 300/500 V
REYRY-Instrument cable with SWA
armor, PVC insulated
(Copper Conductor, PVC Insulated, Individual Screen, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : BS 5308-2 & IEC 60502
Construction Data
Size Application : Copper Conductor
Instrumentation cables are suitable for PVC Insulation
1.5mm2 2.5mm2
No. industrial control system as needed in Tinned Copper -
of Overall Cable Overall Cable measurement, control, signalling and Drain Wires
pairs Diameter Weight Diameter Weight Individual Screen
data system technology.
approx. approx. approx. approx.
Tinned Copper -
mm kg/km mm kg/km Drain Wires
Special Features on Request Collective Screen
2 18.9 687 21.5 869
PVC Inner Sheath
• Fire Resistance
3 21.0 884 23.0 1,077 Galvanized Steel Wire Armor
• Oil Resistance
4 22.5 984 24.5 1,222
• UV Resistance Non-hygroscopic Tape
5 23.5 1,039 26.5 1,294
• Flame Retardant Cat. A, B, C PVC Sheath
6 27.0 1,269 30.0 1,536 • Flame Retardant Non Category
7 27.0 1,289 30.0 1,563 • Heat Resistance
9 30.5 1,549 36.0 2,203 • Anti Termite
10 32.0 1,675 38.5 2,407 • Anti Rodent
12 36.0 2,170 41.5 2,717 • Low Smoke Zero Halogen
14 37.0 2,317 43.0 2,969 • Nylon Coated
15 38.5 2,464 45.5 3,206
16 40.5 2,610 48.5 3,770
Note :
18 42.0 2,808 51.5 4,124
Conductor Shape
19 42.0 2,858 51.5 4,204 All construction supplied in solid (re) or non compacted circular stranded (rm)
20 44.0 3,061 54.0 4,583
Standard Packing
24 52.5 4,103 62.0 5,291 Size 1.5 mm² :
30 55.0 4,540 66.0 6,103 2 - 20 pairs supplied in wooden drum @ 1000 m
36 59.5 5,267 71.0 6,913 24 - 50 pairs supplied in wooden drum on available length
Size 2.5 mm² :
40 61.5 5,594 73.5 7,435 2 - 16 pairs supplied in wooden drum @ 1000 m
48 67.0 6,372 82.5 9,460 18 - 50 pairs supplied in wooden drum on available length
50 68.5 6,543 84.0 9,718 Length tolerance per drum ± 2%
Size of drain wire : 0.5 mm²
Electrical Data
Conductor Insulation
AC
Mutual
Nominal Voltage
Capacitance
Cross Resistance at Resistance at Test
Section 20°C 20°C
www.eescable.com 131
Pairs x 1.5 mm² & (1-50)
Pairs x 2.5 mm² 300/500 V
REYY-Instrument cable without
armor, PVC insulated
(Copper Conductor, PVC Insulated, Collective Screen, PVC Sheathed) Standard Specification : BS
5308-2 & IEC 60502
Construction Data
Size Application :
Copper Conductor
Instrumentation cables are suitable for
1.5mm
2 2.5mm 2
PVC Insulation
No. industrial control system as needed in
of Overall Cable Overall Cable measurement, control, signalling and
pairs Diameter Weight Diameter Weight
data system technology.
approx. approx. approx. approx.
mm kg/km mm kg/km Tinned Copper -
Drain Wires
1 7.7 93 10.9 174 Special Features on Request
Collective Screen
• Fire Resistance
2 10.4 146 14.1 261
• Oil Resistance PVC Sheath
3 12.9 200 16.6 324
• UV Resistance
4 14.4 251 18.6 409
• Flame Retardant Cat. A, B, C
5 15.8 320 20.5 525 • Flame Retardant Non Category
6 17.5 368 22.0 590 • Heat Resistance
7 18.4 407 23.5 654 • Anti Termite
9 20.5 504 27.0 837 • Anti Rodent
10 21.5 552 28.0 917 • Low Smoke Zero Halogen
12 24.0 667 30.5 1,091 • Nylon Coated
14 25.5 763 32.5 1,249
15 26.0 830 34.0 1,376
Note :
16 27.0 877 35.0 1,455 Conductor Shape
18 28.5 953 37.0 1,594 All construction supplied in solid (re) or non compacted circular stranded (rm)
19 29.0 1,000 37.5 1,673
Standard Packing
20 29.5 1,096 39.0 1,853 Size 1.5 mm² :
24 32.5 1,261 42.5 2,111 All conductor supplied in wooden drum @ 1000 m
Size 2.5 mm² :
30 36.0 1,539 47.0 2,598
1 - 36 pairs supplied in wooden drum @ 1000 m
36 39.5 1,879 51.5 3,107 40 - 50 pairs supplied in wooden drum on available length
40 41.5 2,065 54.0 3,440 Length tolerance per drum ± 2%
Size of drain wire : 0.5 mm²
48 45.0 2,434 59.0 4,109
50 46.0 2,526 60.0 4,263
Electrical Data
Conductor Insulation
AC
Mutual
Nominal Voltage
Capacitance
Cross Resistance at Resistance at Test
Section 20°C 20°C
1Pair 2Pair
www.eescable.com 132
Pairs x 1.5 mm² & (2-50)
Pairs x 2.5 mm² 300/500 V
REYY-Instrument cable without
armor, PVC insulated
(Copper Conductor, PVC Insulated, Individual Screen, PVC Sheathed) Standard Specification :
BS 5308-2 & IEC 60502
Construction Data
Electrical Data
Conductor Insulation
AC
Mutual
Nominal Voltage
Capacitance
Cross Resistance Resistance at Test
Section at 20°C 20°C
www.eescable.com 133
N2XSB(AL)Y 1 x (25-630)
mm² 3.6/6 kV
N2XSB(AL)Y-1 core CU XLPE PVC with
ATA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Fire Resistance
25 21.5 729 • Oil Resistance
35 22.5 856 • UV Resistance
• Flame Retardant Cat. A, B, C
50 23.5 998 • Flame Retardant Non Category
70 25.5 1,244 • Anti Termite
• Anti Rodent
95 27.0 1,531
• Low Smoke Zero Halogen
120 28.5 1,804
150 30.0 2,058
185 32.0 2,451 Note :
240 35.0 3,077 Conductor Shape
25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
300 37.5 3,720
400 41.0 4,554 Standard Packing
25 - 300 sqmm supplied in wooden drum @ 1000 m
500 45.5 5,715
400 - 630 sqmm will be suplied in wooden drum on available length
630 49.0 7,136 Length Tolerance per drum ± 2%
Electrical Data
Conductor Inductance Current - Carrying Capacity at 30° C * Short current
Nom. DC AC Trefoil Flat circuit at 1 sec
Cross Resistance Resistance formation formation inair inground inair inground Conductor Screen
Sect. at 20°C at 90°C
www.eescable.com 134
N2XSB(AL)Y 1 x (25-630)
mm² 6/10 kV
N2XSB(AL)Y-1 core CU XLPE PVC with
ATA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Tape Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a risk
Section that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Fire Resistance
25 23.5 812 • Oil Resistance
35 24.5 941 • UV Resistance
• Flame Retardant Cat. A, B, C
50 25.5 1,086 • Flame Retardant Non Category
• Anti Termite
70 27.0 1,337
• Anti Rodent
95 29.0 1,641 • Low Smoke Zero Halogen
120 30.5 1,862
150 32.0 2,175
Note :
185 34.0 2,589
Conductor Shape
240 36.5 3,196 25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
300 39.0 3,762
Standard Packing
400 42.0 4,631 25 - 300 sqmm supplied in wooden drum @ 1000 m
400 - 630 sqmm will be suplied in wooden drum on available length
500 46.0 5,767 Length Tolerance per drum ± 2%
630 49.5 7,192
Electrical Data
www.eescable.com 135
N2XSB(AL)Y 1 x (25-630)
mm² 8.7/15 kV
N2XSB(AL)Y-1 core CU XLPE PVC with
ATA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
25 25.5 919 • UV Resistance
35 26.5 1,052 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
50 27.5 1,200 • Anti Termite
70 29.5 1,428 • Anti Rodent
• Low Smoke Zero Halogen
95 31.0 1,722
120 33.0 2,033
150 34.5 2,339
185 36.5 2,745 Note :
240 39.0 3,303 Conductor Shape
25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
300 41.0 3,913
400 45.0 4,834 Standard Packing
25 - 300 sqmm supplied in wooden drum @ 1000 m
500 48.5 5,942
400 - 630 sqmm will be suplied in wooden drum on available length
630 52.0 7,379 Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 136
N2XSB(AL)Y 1 x (35-630)
mm2 12/20 kV
N2XSB(AL)Y-1 core CU XLPE PVC with
ATA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a risk
Section that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
35 29.0 1,172 • UV Resistance
50 30.0 1,281 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
70 31.5 1,554 • Anti Termite
• Anti Rodent
95 33.5 1,884
• Low Smoke Zero Halogen
120 35.5 2,173
150 37.0 2,483
185 38.5 2,839
Note :
240 41.0 3,441
Conductor Shape
300 43.5 4,076 35 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
400 47.0 5,011 Standard Packing
500 50.5 6,131 35 - 240 sqmm supplied in wooden drum @ 1000 m
300 - 630 sqmm will be suplied in wooden drum on available length
630 54.0 7,580 Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 137
N2XSB(AL)Y 1 x (50-630)
mm² 18/30 kV
N2XSB(AL)Y-1 core CU XLPE PVC with
ATA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
50 35.5 1,639 • UV Resistance
70 37.5 1,913 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
95 39.0 2,185 • Anti Termite
120 40.5 2,467 • Anti Rodent
• Low Smoke Zero Halogen
150 42.5 2,806
• Nylon Coated
185 44.5 3,252
240 47.0 3,895
300 49.5 4,553 Note :
400 52.5 5,475 Conductor Shape
50 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
500 56.0 6,623
630 60.0 8,158 Standard Packing
50 - 240 sqmm supplied in wooden drum @ 1000 m
300 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 138
N2XSEBY 3 x (25-300)
mm² 3.6/6 kV
N2XSEBY-3 core CU XLPE PVC with
STA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Fire Resistance
25 38.5 2,417 • Oil Resistance
35 41.0 2,865 • UV Resistance
Galvanized Steel Tape
• Flame Retardant Cat. A, B, C Armor
50 44.0 3,391 • Flame Retardant Non Category
70 48.0 4,272 • Anti Termite
• Anti Rodent
95 51.5 5,266 • Low Smoke Zero Halogen
120 55.5 6,232
150 59.0 7,271
185 63.0 8,585 Note :
240 69.0 10,679 Conductor Shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 75.5 12,965
Standard Packing
25 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 139
N2XSEBY 3 x (25-300)
mm² 6/10 kV
N2XSEBY-3 core CU XLPE PVC with
STA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Fire Resistance
25 43.0 2,767 • Oil Resistance
35 46.0 3,279 • UV Resistance
Galvanized Steel Tape
• Flame Retardant Cat. A, B, C Armor
50 48.5 3,799 • Flame Retardant Non Category
70 52.5 4,687 • Anti Termite
• Anti Rodent
95 56.5 5,753 • Low Smoke Zero Halogen
120 60.0 6,690
150 63.5 7,761
185 67.5 9,091 Note :
240 73.0 11,235 Conductor Shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 78.0 13,326
Standard Packing
25 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 140
N2XSEBY 3 x (25-300)
mm2 8.7/15 kV
N2XSEBY-3 core CU XLPE PVC with
STA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
25 48.5 3,293 • UV Resistance
35 51.0 3,790 • Flame Retardant Cat. A, B, C
Galvanized Steel Tape
• Flame Retardant Non Category Armor
50 53.5 4,324 • Anti Termite
70 58.0 5,310 • Anti Rodent
• Low Smoke Zero Halogen
95 61.5 6,354
120 65.0 7,321
150 69.0 8,412
185 73.0 9,854 Note :
240 78.5 11,980 Conductor Shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 85.0 14,914
Standard Packing
25 sqmm supplied in wooden drum @ 1000 m
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 141
N2XSEBY 3 x (35-300)
mm² 12/20 kV
N2XSEBY-3 core CU XLPE PVC with
STA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
35 56.5 4,322 • UV Resistance
50 59.0 4,883 • Flame Retardant Cat. A, B, C
Galvanized Steel Tape
• Flame Retardant Non Category Armor
70 63.0 5,836 • Anti Termite
95 66.5 6,905 • Anti Rodent
• Low Smoke Zero Halogen
120 70.0 7,907
150 74.0 9,096
185 77.5 10,488
240 84.5 13,454 Note :
300 89.5 15,722 Conductor Shape
35 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 142
N2XSEBY 3 x (50-300)
mm² 18/30 kV
N2XSEBY-3 core CU XLPE PVC with
STA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
50 71.0 6,335 • UV Resistance
70 75.0 7,435 • Flame Retardant Cat. A, B, C
Galvanized Steel Tape
• Flame Retardant Non Category Armor
95 79.0 8,574 • Anti Termite
120 83.5 10,439 • Anti Rodent
• Low Smoke Zero Halogen
150 87.0 11,661
185 91.0 13,200
240 96.5 15,483
Note :
300 102.0 17,950 Conductor Shape
50 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 143
N2XSEFGbY 3 x (25-300)
mm² 3.6/6 kV
N2XSEFGbY-3 core CU XLPE PVC with
SFWA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 38.5 2,603 Special Features on Request
• Fire Resistance Galvanized Steel Tape
35 41.5 3,074
• Oil Resistance Galvanized Steel Flat
50 44.5 3,641 • UV Resistance
Wire Armor
Standard Packing
25 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 144
N2XSEFGbY 3 x (25-300)
mm² 6/10 kV
N2XSEFGbY-3 core CU XLPE PVC with
SFWA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 43.0 2,984 Special Features on Request
• Fire Resistance Galvanized Steel Tape
35 46.0 3,515
• Oil Resistance Galvanized Steel Flat
50 48.5 4,061 • UV Resistance Wire Armor
Standard Packing
25 - 35 sqmm supplied in wooden drum @ 1000 m
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 145
N2XSEFGbY 3 x (25-300)
mm² 8,7/15 kV
N2XSEFGbY-3 core CU XLPE PVC with
SFWA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 49.0 3,552 Special Features on Request
• Oil Resistance Galvanized Steel Tape
35 51.5 4,072
• UV Resistance Galvanized Steel Flat
50 54.0 4,606 • Flame Retardant Cat. A, B, C
Wire Armor
Standard Packing
25 sqmm supplied in wooden drum @ 1000 m
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 146
N2XSEFGbY 3 x (35-300)
mm² 12/20 kV
N2XSEFGbY-3 core CU XLPE PVC with
SFWA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
35 56.5 4,624 Special Features on Request
• Oil Resistance Galvanized Steel Tape
50 59.0 5,185 Galvanized Steel Flat
• UV Resistance
70 63.0 6,194 • Flame Retardant Cat. A, B, C
Wire Armor
Standard Packing
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 147
N2XSEFGbY 3 x (50-300)
mm² 18/30 kV
N2XSEFGbY-3 core CU XLPE PVC with
SFWA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
50 71.0 6,738 Special Features on Request
Galvanized Steel Tape
70 75.5 7,869 • Oil Resistance
• UV Resistance Galvanized Steel Flat
95 79.0 9,021 • Flame Retardant Cat. A, B, C Wire Armor
120 82.5 10,109 • Flame Retardant Non Category
• Anti Termite
150 86.0 11,335
• Anti Rodent
185 90.0 12,808 • Low Smoke Zero Halogen
240 95.5 15,124
300 101.0 17,512
Note :
Conductor Shape
50 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 148
N2XSERY 3 x (25-300)
mm² 3.6/6 kV
N2XSEFGbY-3 core CU XLPE PVC with
SWA Armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 41.0 3,102 Special Features on Request
Galvanized Steel Wire Armor
35 43.5 3,587 • Fire Resistance
• Oil Resistance
50 48.0 4,576 • UV Resistance
70 52.0 5,579 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
95 55.5 6,642
• Anti Termite
120 59.5 7,711 • Anti Rodent
150 63.0 8,859 • Low Smoke Zero Halogen
Standard Packing
25 - 35 sqmm supplied in wooden drum @ 1000 m
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 149
N2XSERY 3 x (25-300)
mm² 6/10 kV
N2XSEFGbY-3 core CU XLPE PVC with
SWA Armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 46.5 3,907 Special Features on Request
Galvanized Steel Wire Armor
35 50.0 4,496 • Fire Resistance
• Oil Resistance
50 52.5 5,103 • UV Resistance
70 56.5 6,093 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
95 60.5 7,262
• Anti Termite
120 64.0 8,309 • Anti Rodent
150 67.5 9,448 • Low Smoke Zero Halogen
Standard Packing
25 sqmm supplied in wooden drum @ 1000 m
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 150
N2XSERY 3 x (25-300)
mm² 8.7/15 kV
N2XSEFGbY-3 core CU XLPE PVC with
SWA Armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 52.5 4,594 Special Features on Request
Galvanized Steel Wire Armor
35 55.0 5,174 • Oil Resistance
• UV Resistance
50 57.5 5,755 • Flame Retardant Cat. A, B, C
70 62.0 6,876 • Flame Retardant Non Category
• Anti Termite
95 65.5 7,989 • Anti Rodent
120 69.0 9,065 • Low Smoke Zero Halogen
150 73.0 10,266
185 78.5 12,655
240 84.0 14,959
Note :
300 89.0 17,314 Conductor Shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
25 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 151
N2XSERY 3 x (35-300)
mm² 12/20 kV
N2XSEFGbY-3 core CU XLPE PVC with
SWA Armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
35 60.5 5,831 Special Features on Request
Galvanized Steel Wire Armor
50 62.5 6,479 • Oil Resistance
• UV Resistance
70 66.5 7,534 • Flame Retardant Cat. A, B, C
95 70.5 8,673 • Flame Retardant Non Category
• Anti Termite
120 74.0 9,784 • Anti Rodent
150 79.5 11,920 • Low Smoke Zero Halogen
185 83.0 13,514
240 89.0 15,860
300 93.5 18,224
Note :
Conductor Shape
35 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 152
N2XSERY 3 x (50-300)
mm² 18/30 kV
N2XSEFGbY-3 core CU XLPE PVC with
SWA Armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
50 76.0 9,043 Special Features on Request
Galvanized Steel Wire Armor
70 80.5 10,271 • Oil Resistance
• UV Resistance
95 84.0 11,550 • Flame Retardant Cat. A, B, C
120 87.5 12,764 • Flame Retardant Non Category
• Anti Termite
150 91.5 14,133 • Anti Rodent
185 95.5 15,733 • Low Smoke Zero Halogen
240 100.5 18,203
300 106.0 20,795
Note :
Conductor Shape
50 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 153
N2XSEY 3 x (25-300) mm²
3.6/6 kV
N2XSEY-3 core CU XLPE PVC without
armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
Indoors, cable trunking, outdoors and in ground;
Cross Diameter Weight For power stations, industry and switchgear.
Section
Area approx. approx. Special Features on Request
• Fire Resistance
mm² mm kg/km
• Oil Resistance
25 37.0 1,868 • UV Resistance
35 39.5 2,275 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
50 42.5 2,778 • Anti Termite
70 46.5 3,577 • Anti Rodent
• Low Smoke Zero Halogen
95 50.0 4,517 • Nylon Coated
120 54.0 5,422
150 57.5 6,406
185 61.5 7,662 Note :
240 67.5 9,664 Conductor Shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 74.0 11,852
Standard Packing
25 - 70 sqmm supplied in wooden drum @ 1000 m
95 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 154
N2XSEY 3 x (25-300) mm²
6/10 kV
N2XSEY-3 core CU XLPE PVC without
armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard Specification :
IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
Indoors, cable trunking, outdoors and in ground;
Cross Diameter Weight For power stations, industry and switchgear.
Section
Area approx. approx. Special Features on Request
• Fire Resistance
mm² mm kg/km
• Oil Resistance
25 41.0 2,153 • UV Resistance
• Flame Retardant Cat. A, B, C
35 44.0 2,618
• Flame Retardant Non Category
50 46.5 3,101 • Anti Termite
70 50.5 3,927 • Anti Rodent
• Low Smoke Zero Halogen
95 55.0 4,957 • Nylon Coated
120 58.5 5,841
150 62.0 6,858
185 66.0 8,132 Note :
240 71.5 10,156 Conductor Shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 76.5 12,205
Standard Packing
25 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 155
N2XSEY 3 x (25-300) mm²
8.7/15 kV
N2XSEY-3 core CU XLPE PVC without
armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard Specification
: IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
Indoors, cable trunking, outdoors and in ground;
Cross Diameter Weight For power stations, industry and switchgear.
Section
Area approx. approx. Special Features on Request
• Oil Resistance
mm² mm kg/km
• UV Resistance
25 47.0 2,592 • Flame Retardant Cat. A, B, C
35 49.5 3,048 • Flame Retardant Non Category
• Anti Termite
50 52.0 3,546 • Anti Rodent
70 56.5 4,463 • Low Smoke Zero Halogen
• Nylon Coated
95 60.0 5,452
120 63.5 6,364
150 67.0 7,401
185 71.5 8,778 Note :
240 77.0 10,820 Conductor Shape
25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 82.0 12,912
Standard Packing
25 - 35 sqmm supplied in wooden drum @ 1000 m
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 156
N2XSEY 3 x (35-300) mm²
12/20 kV
N2XSEY-3 core CU XLPE PVC without
armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard Specification : IEC
60502-2
Construction Data
Application :
Nom. Overall Cable
Indoors, cable trunking, outdoors and in ground;
Cross Diameter Weight For power stations, industry and switchgear.
Section
Area approx. approx. Special Features on Request
• Oil Resistance
mm² mm kg/km
• UV Resistance
35 54.5 3,501 • Flame Retardant Cat. A, B, C
50 57.0 4,026 • Flame Retardant Non Category
• Anti Termite
70 61.0 4,917 • Anti Rodent
95 65.0 5,960 • Low Smoke Zero Halogen
• Nylon Coated
120 68.5 6,909
150 72.5 8,039
185 76.5 9,374
240 82.0 11,458 Note :
300 86.5 13,563 Conductor Shape
35 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 157
N2XSEY 3 x (50-300) mm²
18/30 kV
N2XSEY-3 core CU XLPE PVC without
armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard Specification : IEC
60502-2
Construction Data
Application :
Nom. Overall Cable
Indoors, cable trunking, outdoors and in ground;
Cross Diameter Weight For power stations, industry and switchgear.
Section
Area approx. approx. Special Features on Request
• Oil Resistance
mm² mm kg/km
• UV Resistance
50 69.0 5,294 • Flame Retardant Cat. A, B, C
70 73.5 6,326 • Flame Retardant Non Category
• Anti Termite
95 77.0 7,410 • Anti Rodent
120 81.0 8,466 • Low Smoke Zero Halogen
• Nylon Coated
150 84.5 9,600
185 88.5 11,005
240 93.5 13,151
Note :
300 99.0 15,481 Conductor Shape
50 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 158
N2XSR(AL)Y 1 x (25-630)
mm² 3.6/6 kV
N2XSR(AL)Y-1 core CU XLPE PVC with
AWA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Wire Armor,PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 23.0 821 Special Features on Request
35 24.0 953 • Fire Resistance
• Oil Resistance
50 25.0 1,101 • UV Resistance
70 27.0 1,355 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
95 28.5 1,664 • Anti Termite
120 30.0 1,927 • Anti Rodent
150 31.5 2,206 • Low Smoke Zero Halogen
• Nylon Coated
185 33.5 2,592
240 37.5 3,336
300 40.0 3,994 Note :
400 44.0 4,857 Conductor Shape
500 49.5 6,229 25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
Electrical Data
www.eescable.com 159
N2XSR(AL)Y 1 x (25-630)
mm² 6/10 kV
N2XSR(AL)Y-1 core CU XLPE PVC with
AWA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radius in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm² mm kg/km
25 25.0 917 Special Features on Request
35 26.0 1,051 • Fire Resistance
• Oil Resistance
50 27.0 1,196 • UV Resistance
• Flame Retardant Cat. A, B, C
70 29.0 1,468
• Flame Retardant Non Category
95 30.5 1,768 • Anti Termite
• Anti Rodent
120 32.0 2,007
• Low Smoke Zero Halogen
150 34.5 2,412 • Nylon Coated
185 36.5 2,842
240 39.0 3,465
Note :
300 41.5 4,049
Conductor Shape
400 45.0 4,939 25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
500 50.0 6,258 Standard Packing
630 53.5 7,723 25 - 240 sqmm supplied in wooden drum @ 1000 m
300 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 160
N2XSR(AL)Y 1 x (25-630)
mm² 8.7/15 kV
N2XSR(AL)Y-1 core CU XLPE PVC with
AWA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 27.0 1,035 Special Features on Request
35 28.5 1,180 • Oil Resistance
• UV Resistance
50 29.5 1,334 • Flame Retardant Cat. A, B, C
70 31.0 1,572 • Flame Retardant Non Category
• Anti Termite
95 32.5 1,875
• Anti Rodent
120 35.5 2,282 • Low Smoke Zero Halogen
150 37.5 2,598 • Nylon Coated
Electrical Data
www.eescable.com 161
N2XSR(AL)Y 1 x (35-630)
mm² 12/20 kV
N2XSR(AL)Y-1 core CU XLPE PVC with
AWA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
35 30.5 1,299 Special Features on Request
50 31.5 1,429 • Oil Resistance
• UV Resistance
70 33.5 1,696 • Flame Retardant Cat. A, B, C
95 36.0 2,131 • Flame Retardant Non Category
• Anti Termite
120 38.0 2,431 • Anti Rodent
• Low Smoke Zero Halogen
150 39.5 2,760
• Nylon Coated
185 41.0 3,127
240 43.5 3,744
300 47.0 4,549
Note :
400 51.0 5,524
Conductor Shape
500 54.5 6,672 35 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
630 58.5 8,188 Standard Packing
35 - 240 sqmm supplied in wooden drum @ 1000 m
300 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 162
N2XSR(AL)Y 1 x (50-630)
mm² 18/30 kV
N2XSR(AL)Y-1 core CU XLPE PVC with
AWA armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
50 38.5 1,904 Special Features on Request
70 40.0 2,187 • Oil Resistance
• UV Resistance
95 41.5 2,472 • Flame Retardant Cat. A, B, C
120 43.0 2,764 • Flame Retardant Non Category
• Anti Termite
150 45.0 3,114
• Anti Rodent
185 48.5 3,756 • Low Smoke Zero Halogen
240 51.0 4,395 • Nylon Coated
Standard Packing
50 - 185 sqmm supplied in wooden drum @ 1000 m
240 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 163
N2XSY 1 x (25-630) mm²
3.6/6 kV
N2XSY-1 core CU XLPE PVC without
armor
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radius in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm² mm kg/km
25 17.1 531 Special Features on Request
35 18.2 646 • Fire Resistance
• Oil Resistance
50 19.2 777 • UV Resistance
70 21.0 1,005 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
95 22.5 1,276
• Anti Termite
120 24.5 1,519 • Anti Rodent
150 25.5 1,759 • Low Smoke Zero Halogen
• Nylon Coated
185 27.5 2,131
240 30.5 2,711
300 33.0 3,308 Note :
400 36.5 4,116 Conductor Shape
500 40.5 5,192 25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
Electrical Data
www.eescable.com 164
N2XSY 1 x (25-630) mm²
6/10 kV
N2XSY-1 core CU XLPE PVC without
armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radius in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm² mm kg/km
25 18.9 594 Special Features on Request
35 20.5 712 • Fire Resistance
• Oil Resistance
50 21.5 846 • UV Resistance
• Flame Retardant Cat. A, B, C
70 23.0 1,078
• Flame Retardant Non Category
95 24.5 1,353 • Anti Termite
• Anti Rodent
120 26.0 1,559
• Low Smoke Zero Halogen
150 27.5 1,853 • Nylon Coated
185 29.5 2,218
240 32.0 2,794
Note :
300 34.0 3,334
Conductor Shape
400 37.5 4,163 25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
500 41.0 5,217 Standard Packing
630 44.5 6,595 25 - 300 sqmm supplied in wooden drum @ 1000 m
400 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 165
N2XSY 1 x (25-630) mm²
8.7/15 kV
N2XSY-1 core CU XLPE PVC without
armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radius in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm² mm kg/km
25 21.5 678 Special Features on Request
35 22.5 799 • Oil Resistance
• UV Resistance
50 23.5 936 • Flame Retardant Cat. A, B, C
70 25.0 1,134 • Flame Retardant Non Category
• Anti Termite
95 27.0 1,423
• Anti Rodent
120 28.5 1,673 • Low Smoke Zero Halogen
150 30.0 1,974 • Nylon Coated
Electrical Data
www.eescable.com 166
N2XSY 1 x (35-630) mm²
12/20 kV
N2XSY-1 core CU XLPE PVC without
armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radius in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm² mm kg/km
35 24.5 884 Special Features on Request
50 25.5 984 • Oil Resistance
• UV Resistance
70 27.5 1,236 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
95 29.0 1,518
• Anti Termite
120 30.5 1,786 • Anti Rodent
• Low Smoke Zero Halogen
150 32.0 2,078
• Nylon Coated
185 34.0 2,414
240 36.5 3,004
300 38.5 3,595
Note :
400 42.0 4,447
Conductor Shape
500 45.5 5,523 35 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
630 49.0 6,926 Standard Packing
35 - 300 sqmm supplied in wooden drum @ 1000 m
400 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 167
N2XSY 1 x (50-630) mm²
18/30 kV
N2XSY-1 core CU XLPE PVC without
armor
(Copper Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard Specification
: IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radius in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm² mm kg/km
50 31.0 1,249 Special Features on Request
70 33.0 1,517 • Oil Resistance
• UV Resistance
95 34.5 1,756 • Flame Retardant Cat. A, B, C
120 36.0 2,036 • Flame Retardant Non Category
• Anti Termite
150 37.5 2,337 • Anti Rodent
185 39.5 2,741 • Low Smoke Zero Halogen
240 42.0 3,334 • Nylon Coated
Standard Packing
50 - 300 sqmm supplied in wooden drum @ 1000 m
400 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 168
NA2XSB(AL)Y 1 x (25-630)
mm² 3.6/6 kV
NA2XSB(AL)Y-1 core AL XLPE PVC
with ATA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
25 21.0 570 • UV Resistance
35 22.5 640 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
50 23.5 712 • Anti Termite
70 25.5 832 • Anti Rodent
• Low Smoke Zero Halogen
95 27.0 962
120 28.5 1,092
150 30.0 1,165
Note :
185 32.0 1,337 Conductor Shape
240 34.5 1,607 25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
300 37.5 1,883 Standard Packing
400 41.0 2,214 25 - 630 sqmm supplied in wooden drum @ 1000 m
500 45.0 2,694 Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 169
NA2XSB(AL)Y 1 x (25-630)
mm² 6/10 kV
NA2XSB(AL)Y-1 core AL XLPE PVC
with ATA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a risk
Section that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
25 23.0 652 • UV Resistance
35 24.5 725 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
50 25.5 800 • Anti Termite
70 27.0 925 • Anti Rodent
• Low Smoke Zero Halogen
95 29.0 1,031
120 30.5 1,150
150 32.0 1,281 Note :
Conductor Shape
185 34.0 1,476
25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
240 36.5 1,725
Standard Packing
300 38.5 1,924 25 - 500 sqmm supplied in wooden drum @ 1000 m
400 42.0 2,290 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
500 45.5 2,746
630 50.5 3,333
Electrical Data
www.eescable.com 170
NA2XSB(AL)Y 1 x (25-630)
mm² 8.7/15 kV
NA2XSB(AL)Y-1 core AL XLPE PVC
with ATA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
25 25.5 759 • UV Resistance
35 26.5 836 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
50 27.5 914 • Anti Termite
70 29.5 1,016 • Anti Rodent
• Low Smoke Zero Halogen
95 31.0 1,153
120 33.0 1,321
150 34.5 1,444
Note :
185 36.5 1,631 Conductor Shape
240 38.5 1,832 25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
300 41.0 2,074 Standard Packing
400 45.0 2,493 25 - 500 sqmm supplied in wooden drum @ 1000 m
500 47.5 2,919 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
630 52.5 3,522
Electrical Data
www.eescable.com 171
NA2XSB(AL)Y 1 x (35-630)
mm² 12/20 kV
NA2XSB(AL)Y-1 core AL XLPE PVC
with ATA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a risk
Section that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
35 29.0 956 • UV Resistance
50 29.5 995 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
70 31.5 1,142 • Anti Termite
• Anti Rodent
95 34.0 1,316
• Low Smoke Zero Halogen
120 35.5 1,461
150 36.5 1,588
185 38.5 1,725 Note :
Conductor Shape
240 41.0 1,969
35 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
300 43.0 2,236
Standard Packing
400 47.0 2,670 35 - 400 sqmm supplied in wooden drum @ 1000 m
500 50.0 3,105 500 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
630 55.0 3,725
Electrical Data
www.eescable.com 172
NA2XSB(AL)Y 1 x (50-630)
mm² 18/30 kV
NA2XSB(AL)Y-1 core AL XLPE PVC
with ATA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
50 35.5 1,352 • UV Resistance
70 37.5 1,501 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
95 39.0 1,618 • Anti Termite
120 40.5 1,755 • Anti Rodent
• Low Smoke Zero Halogen
150 42.0 1,909
185 44.5 2,138
240 46.5 2,422
Note :
300 49.0 2,710 Conductor Shape
400 52.5 3,133 50 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
500 55.5 3,592 Standard Packing
630 61.0 4,308 50 - 300 sqmm supplied in wooden drum @ 1000 m
400 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 173
NA2XSEBY 3 x (25-300)
mm² 3.6/6 kV
NA2XSEBY-3 core AL XLPE PVC with
STA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
25 38.0 1,922 • UV Resistance
35 41.0 2,206 • Flame Retardant Cat. A, B, C Galvanized Steel Tape
• Flame Retardant Non Category Armor
50 43.5 2,517 • Anti Termite
70 48.0 3,016 • Anti Rodent
• Low Smoke Zero Halogen
95 52.0 3,534
120 55.5 4,062
150 59.0 4,531
Note :
185 63.0 5,191 Conductor Shape
240 68.5 6,180 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 75.0 7,327 Standard Packing
25 - 70 sqmm supplied in wooden drum @ 1000 m
95 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 174
NA2XSEBY 3 x (25-300)
mm² 6/10 kV
NA2XSEBY-3 core AL XLPE PVC with
STA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
25 42.5 2,270 • UV Resistance
35 45.5 2,619 • Flame Retardant Cat. A, B, C Galvanized Steel Tape
• Flame Retardant Non Category Armor
50 48.0 2,918 • Anti Termite
70 52.5 3,431 • Anti Rodent
• Low Smoke Zero Halogen
95 56.5 4,030
120 60.0 4,520
150 63.0 5,018
Note :
185 67.5 5,697 Conductor Shape
240 73.0 6,733 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 77.5 7,697
Standard Packing
25 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 175
NA2XSEBY 3 x (25-300)
mm² 8.7/15 kV
NA2XSEBY-3 core AL XLPE PVC with
STA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
25 48.0 2,792 • UV Resistance
35 51.0 3,122 • Flame Retardant Cat. A, B, C Galvanized Steel Tape
• Flame Retardant Non Category Armor
50 53.5 3,448 • Anti Termite
70 58.0 4,054 • Anti Rodent
• Low Smoke Zero Halogen
95 62.0 4,624
120 65.0 5,151
150 68.5 5,666
Note :
185 73.0 6,460 Conductor Shape
240 78.0 7,474 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 84.0 9,262 Standard Packing
25 sqmm supplied in wooden drum @ 1000 m
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 176
NA2XSEBY 3 x (35-300)
mm² 12/20 kV
NA2XSEBY-3 core AL XLPE PVC with
STA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
35 56.0 3,659 • UV Resistance
50 58.5 3,998 • Flame Retardant Cat. A, B, C Galvanized Steel Tape
• Flame Retardant Non Category Armor
70 63.0 4,581 • Anti Termite
95 66.5 5,186 • Anti Rodent
• Low Smoke Zero Halogen
120 70.0 5,737
150 73.5 6,346
185 77.5 7,094
Note :
240 84.0 8,941 Conductor Shape
300 89.0 10,064 35 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 177
NA2XSEBY 3 x (50-300)
mm² 18/30 kV
NA2XSEBY-3 core AL XLPE PVC with
STA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Tape Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation indoor, in ground direct burried,
Cross Diameter Weight for power station and switchgear, if there is a
Section risk that low mechanical damage may occur.
Area approx. approx.
mm² mm kg/km Special Features on Request
• Oil Resistance
50 70.5 5,444 • UV Resistance
70 75.0 6,180 • Flame Retardant Cat. A, B, C Galvanized Steel Tape
• Flame Retardant Non Category Armor
95 79.0 6,860 • Anti Termite
120 83.5 8,269 • Anti Rodent
• Low Smoke Zero Halogen
150 87.0 8,898
185 91.0 9,807
240 96.0 10,961
Note :
300 101.5 12,278 Conductor Shape
50 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 178
NA2XSEFGbY 3 x (25-300)
mm² 3.6/6 kV
NA2XSEFGbY-3 core AL XLPE PVC with
SFWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight
trunking and outdoors if increased mechanical
Section
protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
mm² mm kg/km operation.
Standard Packing
25 - 70 sqmm supplied in wooden drum @ 1000 m
95 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 179
NA2XSEFGbY 3 x (25-300)
mm² 6/10 kV
NA2XSEFGbY-3 core AL XLPE PVC with
SFWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 42.5 2,492 Special Features on Request
• Oil Resistance Galvanized Steel Tape
35 46.0 2,857 Galvanized Steel Flat
• UV Resistance
50 48.5 3,182 • Flame Retardant Cat. A, B, C
Wire Armor
Standard Packing
25 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 180
NA2XSEFGbY 3 x (25-300)
mm² 8.7/15 kV
NA2XSEFGbY-3 core AL XLPE PVC with
SFWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 48.5 3,056 Special Features on Request
• Oil Resistance Galvanized Steel Tape
35 51.0 3,380 Galvanized Steel Flat
• UV Resistance
50 53.5 3,732 • Flame Retardant Cat. A, B, C
Wire Armor
Standard Packing
25 sqmm supplied in wooden drum @ 1000 m
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 181
NA2XSEFGbY 3 x (35-300)
mm² 12/20 kV
NA2XSEFGbY-3 core AL XLPE PVC with
SFWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
35 56.5 3,964 Special Features on Request
• Oil Resistance Galvanized Steel Tape
50 59.0 4,302 Galvanized Steel Flat
• UV Resistance
70 63.0 4,938 • Flame Retardant Cat. A, B, C
Wire Armor
Standard Packing
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 182
NA2XSEFGbY 3 x (50-300)
mm² 18/30 kV
NA2XSEFGbY-3 core AL XLPE PVC with
SFWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Flat Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
50 71.0 5,850 Special Features on Request
• Oil Resistance Galvanized Steel Tape
70 75.5 6,613 Galvanized Steel Flat
• UV Resistance
95 79.0 7,305 • Flame Retardant Cat. A, B, C
Wire Armor
Standard Packing
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 183
NA2XSERY 3 x (25-300)
mm² 3.6/6 kV
NA2XSERY-3 core AL XLPE PVC with
SWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 40.5 2,589 Special Features on Request
Galvanized Steel Wire Armor
35 43.5 2,993 • Oil Resistance
• UV Resistance
50 48.0 3,705 • Flame Retardant Cat. A, B, C
70 52.0 4,324 • Flame Retardant Non Category
• Anti Termite
95 56.0 4,947 • Anti Rodent
120 59.5 5,541 • Low Smoke Zero Halogen
150 62.5 6,126
185 67.0 6,886
240 72.5 8,037 Note :
Conductor Shape
300 80.0 10,170 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
25 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 184
NA2XSERY 3 x (25-300)
mm² 6/10 kV
NA2XSERY-3 core AL XLPE PVC with
SWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 46.5 3,417 Special Features on Request
Galvanized Steel Wire Armor
35 49.5 3,840 • Oil Resistance
• UV Resistance
50 52.0 4,225 • Flame Retardant Cat. A, B, C
70 56.5 4,837 • Flame Retardant Non Category
• Anti Termite
95 60.5 5,535 • Anti Rodent
120 64.0 6,139 • Low Smoke Zero Halogen
150 67.0 6,712
185 71.0 7,490
240 78.0 9,474 Note :
Conductor Shape
300 83.0 10,662 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
25 - 35 sqmm supplied in wooden drum @ 1000 m
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 185
NA2XSERY 3 x (25-300)
mm² 8.7/15 kV
NA2XSERY-3 core AL XLPE PVC with
SWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 52.0 4,099 Special Features on Request
Galvanized Steel Wire Armor
35 55.0 4,509 • Oil Resistance
• UV Resistance
50 57.5 4,882 • Flame Retardant Cat. A, B, C
70 62.0 5,620 • Flame Retardant Non Category
• Anti Termite
95 66.0 6,296 • Anti Rodent
120 69.0 6,895 • Low Smoke Zero Halogen
150 72.5 7,486
185 78.5 9,262
240 83.5 10,461 Note :
Conductor Shape
300 88.5 11,679 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
25 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 186
NA2XSERY 3 x (35-300)
mm² 12/20 kV
NA2XSERY-3 core AL XLPE PVC with
SWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Wire Armor, PVC Sheathed)
Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
35 60.0 5,172 Special Features on Request
Galvanized Steel Wire Armor
50 62.5 5,557 • Oil Resistance
• UV Resistance
70 66.5 6,279 • Flame Retardant Cat. A, B, C
95 70.5 6,990 • Flame Retardant Non Category
• Anti Termite
120 74.0 7,614 • Anti Rodent
150 79.0 9,176 • Low Smoke Zero Halogen
185 83.0 10,120
240 88.5 11,358
300 93.0 12,519 Note :
Conductor Shape
35 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 187
NA2XSERY 3 x (50-300)
mm² 18/30 kV
NA2XSERY-3 core AL XLPE PVC with
SWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Galvanized Steel Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
50 76.0 8,156.2 Special Features on Request
Galvanized Steel Wire Armor
70 80.5 9,015.5 • Oil Resistance
• UV Resistance
95 84.5 9,832.9 • Flame Retardant Cat. A, B, C
120 87.5 10,594.3 • Flame Retardant Non Category
• Anti Termite
150 91.0 11,381.5 • Anti Rodent
185 95.5 12,339.3 • Low Smoke Zero Halogen
240 100.0 13,628.8
300 105.5 15,076.6
Note :
Conductor Shape
50 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 188
NA2XSEY 3 x (25-300)
mm2 3.6/6 kV
NA2XSEY-3 core AL XLPE PVC without
armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
Indoors, cable trunking, outdoors and in ground;
Cross Diameter Weight For power stations, industry and switchgear.
Section
Area approx. approx. Special Features on Request
mm² mm kg/km • Oil Resistance
• UV Resistance
25 36.5 1,380 • Flame Retardant Cat. A, B, C
35 39.5 1,620 • Flame Retardant Non Category
• Anti Termite
50 42.0 1,908 • Anti Rodent
70 46.5 2,322 • Low Smoke Zero Halogen
• Nylon Coated
95 50.0 2,781
120 54.0 3,252
150 57.0 3,673
Note :
185 61.5 4,268 Conductor Shape
240 67.0 5,172 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 73.0 6,226 Standard Packing
25 - 70 sqmm supplied in wooden drum @ 1000 m
95 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 189
NA2XSEY 3 x (25-300)
mm² 6/10 kV
NA2XSEY-3 core AL XLPE PVC without
armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
Indoors, cable trunking, outdoors and in ground;
Cross Diameter Weight For power stations, industry and switchgear.
Section
Area approx. approx. Special Features on Request
mm² mm kg/km • Oil Resistance
• UV Resistance
25 40.5 1,663 • Flame Retardant Cat. A, B, C
35 44.0 1,962 • Flame Retardant Non Category
• Anti Termite
50 46.5 2,224 • Anti Rodent
70 50.5 2,672 • Low Smoke Zero Halogen
• Nylon Coated
95 55.0 3,230
120 58.5 3,671
150 61.5 4,122
Note :
185 66.0 4,738 Conductor Shape
240 71.0 5,661 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 76.0 6,586
Standard Packing
25 - 50 sqmm supplied in wooden drum @ 1000 m
70 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 190
NA2XSEY 3 x (25-300)
mm2 8.7/15 kV
NA2XSEY-3 core AL XLPE PVC without
armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard Specification :
IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
Indoors, cable trunking, outdoors and in ground;
Cross Diameter Weight For power stations, industry and switchgear.
Section
Area approx. approx. Special Features on Request
mm² mm kg/km • Oil Resistance
• UV Resistance
25 46.5 2,097 • Flame Retardant Cat. A, B, C
35 49.5 2,384 • Flame Retardant Non Category
• Anti Termite
50 52.0 2,673 • Anti Rodent
70 56.5 3,207 • Low Smoke Zero Halogen
• Nylon Coated
95 60.0 3,719
120 63.5 4,194
150 66.5 4,662
Note :
185 71.5 5,384 Conductor Shape
240 76.5 6,321 25 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
300 81.5 7,277
Standard Packing
25 - 35 sqmm supplied in wooden drum @ 1000 m
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 191
NA2XSEY 3 x (35-300)
mm² 12/20 kV
NA2XSEY-3 core AL XLPE PVC without
armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
Indoors, cable trunking, outdoors and in ground;
Cross Diameter Weight For power stations, industry and switchgear.
Section
Area approx. approx. Special Features on Request
mm² mm kg/km • Oil Resistance
• UV Resistance
35 54.5 2,842 • Flame Retardant Cat. A, B, C
50 57.0 3,144 • Flame Retardant Non Category
• Anti Termite
70 61.0 3,661 • Anti Rodent
95 65.0 4,238 • Low Smoke Zero Halogen
• Nylon Coated
120 68.5 4,739
150 72.0 5,296
185 76.5 5,980
Note :
240 81.5 6,956 Conductor Shape
300 86.0 7,922 35 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
35 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 192
NA2XSEY 3 x (50-300)
mm² 18/30 kV
NA2XSEY-3 core AL XLPE PVC without
armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard Specification :
IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
Indoors, cable trunking, outdoors and in ground;
Cross Diameter Weight For power stations, industry and switchgear.
Section
Area approx. approx. Special Features on Request
mm² mm kg/km • Oil Resistance
• UV Resistance
50 69.0 4,407 • Flame Retardant Cat. A, B, C
70 73.5 5,071 • Flame Retardant Non Category
• Anti Termite
95 77.5 5,693 • Anti Rodent
120 81.0 6,296 • Low Smoke Zero Halogen
• Nylon Coated
150 84.0 6,848
185 88.5 7,611
240 93.0 8,641
Note :
300 98.5 9,826 Conductor Shape
50 - 300 sqmm supplied in compacted circular stranded (cm) conductor shape
Standard Packing
50 - 300 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 193
NA2XSR(AL)Y 1 x (25-630)
mm² 3.6/6 kV
NA2XSR(AL)Y-1 core AL XLPE PVC
with AWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 22.5 663 Special Features on Request
35 24.0 738 • Oil Resistance
• UV Resistance
50 25.0 816 • Flame Retardant Cat. A, B, C
70 27.0 943 • Flame Retardant Non Category
• Anti Termite
95 28.5 1,094 • Anti Rodent
120 30.0 1,215 • Low Smoke Zero Halogen
150 31.5 1,313 • Nylon Coated
Electrical Data
www.eescable.com 194
NA2XSR(AL)Y 1 x (25-630)
mm2 6/10 kV
NA2XSR(AL)Y-1 core AL XLPE PVC
with AWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 24.5 752 Special Features on Request
35 26.0 830 • Oil Resistance
• UV Resistance
50 27.0 911 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
70 29.0 1,056
• Anti Termite
95 30.5 1,159 • Anti Rodent
• Low Smoke Zero Halogen
120 32.0 1,295
• Nylon Coated
150 34.5 1,518
185 36.5 1,729
240 39.0 1,996 Note :
Conductor Shape
300 41.0 2,204 25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
400 44.5 2,599
Standard Packing
500 49.5 3,239 25 - 500 sqmm supplied in wooden drum @ 1000 m
630 54.0 3,875 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 195
NA2XSR(AL)Y 1 x (25-630)
mm2 8.7/15 kV
NA2XSR(AL)Y-1 core AL XLPE PVC
with AWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
25 27.0 870 Special Features on Request
35 28.5 964 • Oil Resistance
• UV Resistance
50 29.5 1,049 • Flame Retardant Cat. A, B, C
70 31.0 1,160 • Flame Retardant Non Category
• Anti Termite
95 33.0 1,306
• Anti Rodent
120 35.5 1,570 • Low Smoke Zero Halogen
150 37.0 1,695 • Nylon Coated
Electrical Data
www.eescable.com 196
NA2XSR(AL)Y 1 x (35-630)
mm2 12/20 kV
NA2XSR(AL)Y-1 core AL XLPE PVC
with AWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
35 30.5 1,084 Special Features on Request
50 31.5 1,138 • Oil Resistance
• UV Resistance
70 33.5 1,284 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
95 36.5 1,562
• Anti Termite
120 38.0 1,719 • Anti Rodent
• Low Smoke Zero Halogen
150 39.5 1,857
• Nylon Coated
185 41.0 2,014
240 43.5 2,274
300 47.0 2,697 Note :
Conductor Shape
400 51.0 3,170 35 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
500 54.0 3,635
Standard Packing
630 59.0 4,344 35 - 300 sqmm supplied in wooden drum @ 1000 m
400 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 197
NA2XSR(AL)Y 1 x (50-630)
mm2 18/30 kV
NA2XSR(AL)Y-1 core AL XLPE PVC
with AWA armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, Aluminium Wire Armor, PVC
Sheathed) Standard Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For installation in the ground, indoors, cable
Cross Diameter Weight trunking and outdoors if increased mechanical
Section protection is required or where high-pulling
Area approx. approx. stresses may occur during installation or
operation.
mm² mm kg/km
50 38.0 1,617 Special Features on Request
70 40.0 1,776 • Oil Resistance
• UV Resistance
95 41.5 1,903 • Flame Retardant Cat. A, B, C
120 43.0 2,052 • Flame Retardant Non Category
• Anti Termite
150 44.5 2,218
• Anti Rodent
185 48.5 2,642 • Low Smoke Zero Halogen
240 50.5 2,923 • Nylon Coated
Standard Packing
50 - 185 sqmm supplied in wooden drum @ 1000 m
240 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 198
NA2XSY 1 x (25-630) mm²
3.6/6 kV
NA2XSR(AL)Y-1 core AL XLPE PVC
without Armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radii in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm mm kg/km
25 16.9 374 Special Features on Request
35 18.1 431 • Oil Resistance
• UV Resistance
50 19.1 492 • Flame Retardant Cat. A, B, C
70 21.0 593 • Flame Retardant Non Category
• Anti Termite
95 23.0 706
• Anti Rodent
120 24.5 807 • Low Smoke Zero Halogen
150 25.5 867 • Nylon Coated
Electrical Data
www.eescable.com 199
NA2XSY 1 x (25-630) mm²
6/10 kV
NA2XSR(AL)Y-1 core AL XLPE PVC
without Armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard Specification
: IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radii in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm mm kg/km
25 18.7 437 Special Features on Request
35 19.9 497 • Oil Resistance
• UV Resistance
50 21.0 561 • Flame Retardant Cat. A, B, C
70 23.0 666 • Flame Retardant Non Category
• Anti Termite
95 24.5 744 • Anti Rodent
• Low Smoke Zero Halogen
120 26.0 847
• Nylon Coated
150 27.5 961
185 29.5 1,104
240 31.5 1,326 Note :
Conductor Shape
300 34.0 1,500
25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
400 37.5 1,824
Standard Packing
500 40.5 2,204 25 - 630 sqmm supplied in wooden drum @ 1000 m
630 45.0 2,728 Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 200
NA2XSY 1 x (25-630) mm²
8.7/15 kV
NA2XSR(AL)Y-1 core AL XLPE PVC
without Armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radii in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm mm kg/km
25 21.0 520 Special Features on Request
35 22.5 584 • Oil Resistance
• UV Resistance
50 23.5 651 • Flame Retardant Cat. A, B, C
70 25.0 722 • Flame Retardant Non Category
• Anti Termite
95 27.0 853 • Anti Rodent
120 28.5 961 • Low Smoke Zero Halogen
150 30.0 1,081 • Nylon Coated
Electrical Data
www.eescable.com 201
NA2XSY 1 x (35-630) mm²
12/20 kV
NA2XSR(AL)Y-1 core AL XLPE PVC
without Armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radii in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm mm kg/km
35 24.5 669 Special Features on Request
50 25.5 698 • Oil Resistance
• UV Resistance
70 27.5 824 • Flame Retardant Cat. A, B, C
• Flame Retardant Non Category
95 29.0 948
• Anti Termite
120 30.5 1,074 • Anti Rodent
• Low Smoke Zero Halogen
150 32.0 1,185
• Nylon Coated
185 34.0 1,300
240 36.5 1,535
300 38.5 1,759 Note :
Conductor Shape
400 42.0 2,107 25 - 630 sqmm supplied in compacted circular stranded (cm) conductor shape
500 45.0 2,506
Standard Packing
630 49.5 3,063 25 - 630 sqmm supplied in wooden drum @ 1000 m
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 202
NA2XSY 1 x (50-630) mm²
18/30 kV
NA2XSR(AL)Y-1 core AL XLPE PVC
without Armor
(Aluminium Conductor, XLPE Insulated, Copper Tape Screen, PVC Sheathed) Standard
Specification : IEC 60502-2
Construction Data
Application :
Nom. Overall Cable
For power stations and switchgear as well as
Cross Diameter Weight stations because of small bending radii in
Section confined spaces indoors. As underground
Area approx. approx. because of light weight where installation
conditions are difficult.
mm mm kg/km
50 31.0 963 Special Features on Request
70 33.0 1,105 • Oil Resistance
• UV Resistance
95 34.5 1,187 • Flame Retardant Cat. A, B, C
120 36.0 1,324 • Flame Retardant Non Category
• Anti Termite
150 37.5 1,443 • Anti Rodent
185 39.5 1,628 • Low Smoke Zero Halogen
240 41.5 1,863 • Nylon Coated
Standard Packing
50 - 400 sqmm supplied in wooden drum @ 1000 m
500 - 630 sqmm will be suplied in wooden drum on available length
Length Tolerance per drum ± 2%
Electrical Data
www.eescable.com 203
CU/XLPE/CORRUGATED
AL/PVC
Power Cable High Voltage(Power
Cable HV)
www.eescable.com 204
2/3/4 Core Copper/ Aluminium
Concentric Cable
Concentric Cable Low Voltage
Application
The concentric cable 600/1000V is used as electric service
from the power distribution ,to transmit the power to the
business center ,residential and rural areas.
Cable construction
Popular size: 8AWG ~ 4AWG , 6 ~ 25mm2
Insulation : XLPE/PVC/PE
www.eescable.com 205
ASTM Standard
Concentric Cable Low Voltage
ASTM Standard
No. of cores Nominal Conductor Thickness of Concentric Thickness of Approx. Max. DC resistance of
cross section Insulation Neutral Sheath overall Dia. conductor at 20℃
conductor
Ω/km Ω/km
AWG No. Dia. mm No. Dia. mm mm
(Phase) (Neutral)
Copper Conductor (ASTM Standard)
2X #12 7 0.78 1.14 39 0.321 1.14 7.74 5.43 5.5
2X #10 7 0.98 1.14 25 0.511 1.14 8.72 3.41 3.5
2X #8 7 1.23 1.14 25 0.643 1.14 9.74 2.14 2.2
2X #6 7 1.55 1.14 25 0.813 1.14 11.04 1.35 1.4
2X #4 7 1.96 1.14 26 1.02 1.14 12.68 0.848 0.85
3X #8 7 1.23 1.14 65 0.405 1.14 11.3X17.3 2.14 2.2
3X #6 7 1.55 1.14 65 0.511 1.52 13.2X20.2 1.35 1.4
3X #4 7 1.96 1.14 65 0.643 1.52 14.7X22.9 0.848 0.85
3X #2 7 2.47 1.14 65 0.823 1.52 16.6X26.3 0.524 0.53
www.eescable.com 206
IEC Standard
Concentric Cable Low Voltage
IEC Standard
Ω/km Ω/km
mm2 No. Dia. mm No. Dia. mm mm
(Phase) (Neutral)
Copper Conductor (IEC Standard)
2X10 7 1.35 1.55 20 0.85 1.4 11.8 1.83 1.9
2X16 7 1.7 1.55 32 0.85 1.4 12.84 1.15 1.2
2X25 7 2.14 1.6 29 1.13 1.5 15.02 0.727 0.76
2X35 19 1.53 1.65 27 1.35 1.6 17 0.524 0.55
8000Aluminum Alloy Conductor (IEC Standard)
2X10 7 1.35 1.55 23 1.13 1.4 12.41 3.08 1.335
2X16 7 1.7 1.55 26 1.13 1.4 13.46 1.91 1.808
2X25 7 2.14 1.6 29 1.13 1.5 15.08 1.2 1.0586
2X35 19 1.53 1.65 27 1.35 1.6 17.05 0.868 0.7966
IEC Standard
Outer sheath
Cable Conductor size Insulation thickness Concentric conductor Overall Cable
thickness
Size (AAC) (XLPE) (AAAC 8000) Diameter Mass
(PVC)
www.eescable.com 207
15kV Aluminum Conductor
90°C (100% – .175")
Concentric Cable Medium Voltage
Underground Residential
Distribution Cable (URD)
15kV Aluminum Conductor 90°C
(100% – .175")
• Conductor Shield – Semi-Conducting Layer
• Insulation – TRXLPE Concentric Insulation Conductor
Jacket Wires Shield Shield
• Insulation Shield – Semi-Conducting Layer Insulation
• Concentric Wires – One-third and Full Neutral Conductor
• Jacket – Non-Conducting Polyethylene (LLDPE) with 3
Red Stripes, Semi-Conducting Available
Copper Diameter*
Conductor (per ANSI/ICEAS-94-649) Weights (lbs/ft)
Neutral
Aluminum Number Number Over Total Total With
AWGor Size Min.Over Max.Over Embedded
of of Wires Conductor Conductor Neutral Without Embedded
kcmil AWG Insulation Insulation Jacket
Strands Jacket Jacket
www.eescable.com 208
15kV Copper Conductor
90°C (100% – .175")
Concentric Cable Medium Voltage
Underground Residential
Distribution Cable (URD)
15kV Copper Conductor 90°C
(100% – .175")
• Conductor Shield – Semi-Conducting Layer
• Insulation – TRXLPE Jacket
Concentric Insulation
Wires Shield
Conductor
Shield
• Insulation Shield – Semi-Conducting Layer Insulation
• Concentric Wires – One-third and Full Neutral Conductor
• Jacket – Non-Conducting Polyethylene (LLDPE) with 3
Red Stripes, Semi-Conducting Available
Copper Diameter*
Conductor (per ANSI/ICEAS-94-649) Weights (lbs/ft)
Neutral
Copper Number Number Over Total Total With
AWGor Size Conductor Min.Over Max.Over Embedded
of of Wires Conductor Neutral Without Embedded
kcmil AWG Insulation Insulation Jacket
Strands Jacket Jacket
www.eescable.com 209
15kV Aluminum Conductor
90°C (133% – .220")
Concentric Cable Medium Voltage
Underground Residential
Distribution Cable (URD)
15kV Aluminum Conductor 90°C
(133% – .220")
• Conductor Shield – Semi-Conducting Layer
• Insulation – TRXLPE Concentric Insulation Conductor
Jacket Wires Shield Shield
• Insulation Shield – Semi-Conducting Layer Insulation
• Concentric Wires – One-third and Full Neutral Conductor
• Jacket – Non-Conducting Polyethylene (LLDPE) with 3
Red Stripes, Semi-Conducting Available
Copper Diameter*
Conductor (per ANSI/ICEAS-94-649) Weights (lbs/ft)
Neutral
Aluminum Number Number Over Total Total With
AWGor Size Conductor Min.Over Max.Over Embedded
of of Wires Conductor Neutral Without Embedded
kcmil AWG Insulation Insulation Jacket
Strands Jacket Jacket
www.eescable.com 210
15kV Copper Conductor
90°C (133% – .220")
Concentric Cable Medium Voltage
Underground Residential
Distribution Cable (URD)
15kV Copper Conductor 90°C
(133% – .220")
• Conductor Shield – Semi-Conducting Layer
• Insulation – TRXLPE Concentric Insulation Conductor
Jacket Wires Shield Shield
• Insulation Shield – Semi-Conducting Layer Insulation
• Concentric Wires – One-third and Full Neutral Conductor
• Jacket – Non-Conducting Polyethylene (LLDPE) with 3
Red Stripes, Semi-Conducting Available
Copper Diameter*
Conductor (per ANSI/ICEAS-94-649) Weights (lbs/ft)
Neutral
Copper Number Number Over Total Total With
AWGor Size Conductor Min.Over Max.Over Embedded
of of Wires Conductor Neutral Without Embedded
kcmil AWG Insulation Insulation Jacket
Strands Jacket Jacket
www.eescable.com 211
25kV Aluminum Conductor
90°C (100% – .260")
Concentric Cable Medium Voltage
Underground Residential
Distribution Cable (URD)
25kV Aluminum Conductor 90°C
(100% – .260")
• Conductor Shield – Semi-Conducting Layer
• Insulation – TRXLPE Concentric Insulation Conductor
Jacket Wires Shield Shield
• Insulation Shield – Semi-Conducting Layer Insulation
• Concentric Wires – One-third and Full Neutral Conductor
• Jacket – Non-Conducting Polyethylene (LLDPE) with 3
Red Stripes, Semi-Conducting Available
Copper Diameter*
Conductor (per ANSI/ICEAS-94-649) Weights (lbs/ft)
Neutral
Aluminum Number Number Over Total Total With
AWGor Size Min.Over Max.Over Embedded
of of Wires Conductor Conductor Neutral Without Embedded
kcmil AWG Insulation Insulation Jacket
Strands Jacket Jacket
www.eescable.com 212
25kV Copper Conductor
90°C (100% – .260")
Concentric Cable Medium Voltage
Underground Residential
Distribution Cable (URD)
25kV Copper Conductor 90°C
(100% – .260")
• Conductor Shield – Semi-Conducting Layer
• Insulation – TRXLPE Concentric Insulation Conductor
Jacket Wires Shield Shield
• Insulation Shield – Semi-Conducting Layer Insulation
• Concentric Wires – One-third and Full Neutral Conductor
• Jacket – Non-Conducting Polyethylene (LLDPE) with 3
Red Stripes, Semi-Conducting Available
Copper Diameter*
Conductor (per ANSI/ICEAS-94-649) Weights (lbs/ft)
Neutral
Copper Number Number Over Total Total With
AWGor Size Min.Over Max.Over Embedded
of of Wires Conductor Conductor Neutral Without Embedded
kcmil AWG Insulation Insulation Jacket
Strands Jacket Jacket
www.eescable.com 213
35kV Aluminum Conductor
90°C (100% – .345")
Concentric Cable Medium Voltage
Underground Residential
Distribution Cable (URD)
35kV Aluminum Conductor 90°C
(100% – .345")
• Conductor Shield – Semi-Conducting Layer
• Insulation – TRXLPE Concentric Insulation Conductor
Jacket Wires Shield Shield
• Insulation Shield – Semi-Conducting Layer Insulation
• Concentric Wires – One-third and Full Neutral Conductor
• Jacket – Non-Conducting Polyethylene (LLDPE) with 3
Red Stripes, Semi-Conducting Available
Copper Diameter*
Conductor Neutral (per ANSI/ICEAS-94-649) Weights (lbs/ft)
Aluminum Number Number Over Total Total With
AWGor of of Wires Size Min.Over Max.Over Embedded Without Embedded
kcmil Strands AWG Conductor Insulation Insulation Jacket Conductor Neutral Jacket Jacket
1/0 SOLID 16 14 0.325 1.010 1.110 1.405 0.0972 0.212 0.745 0.934
1/0 19 16 14 0.362 1.045 1.145 1.430 0.0990 0.212 0.768 0.957
Full 2/0 19 13 12 0.406 1.090 1.190 1.475 0.1250 0.275 0.885 1.105
Neutral
3/0 19 16 12 0.456 1.140 1.240 1.520 0.1575 0.340 1.010 1.231
4/0 19 20 12 0.512 1.195 1.295 1.575 0.1986 0.425 1.170 1.421
1/0 SOLID 6 14 0.325 1.010 1.110 1.405 0.0972 0.080 0.610 0.817
1/0 19 6 14 0.362 1.045 1.145 1.430 0.0991 0.080 0.635 0.840
2/0 19 7 14 0.406 1.090 1.190 1.475 0.1249 0.093 0.703 0.911
3/0 19 9 14 0.456 1.140 1.240 1.500 0.1575 0.120 0.790 1.003
4/0 19 11 14 0.512 1.195 1.295 1.575 0.1986 0.145 0.890 1.120
One-Third
Neutral 250 37 13 14 0.558 1.250 1.350 1.705 0.2347 0.173 1.005 1.305
350 37 11 12 0.661 1.355 1.455 1.810 0.3286 0.240 1.225 1.584
500 37 16 12 0.789 1.480 1.580 2.000 0.4694 0.340 1.599 2.001
750 61 15 10 0.968 1.670 1.770 2.190 0.7040 0.506 2.125 2.623
1000 61 20 10 1.117 1.815 1.920 2.380 0.9387 0.681 2.730 3.137
www.eescable.com 214
35kV Copper Conductor
90°C (100% – .345")
Concentric Cable Medium Voltage
Underground Residential
Distribution Cable (URD)
35kV Copper Conductor 90°C
(100% – .345")
• Conductor Shield – Semi-Conducting Layer
• Insulation – TRXLPE Concentric Insulation Conductor
Jacket Wires Shield Shield
• Insulation Shield – Semi-Conducting Layer Insulation
• Concentric Wires – One-third and Full Neutral Conductor
• Jacket – Non-Conducting Polyethylene (LLDPE) with 3
Red Stripes, Semi-Conducting Available
Copper Diameter*
Conductor Neutral (per ANSI/ICEAS-94-649) Weights (lbs/ft)
Copper Number Number Over Total Total With
AWGor of of Wires Size Min.Over Max.Over Embedded Without Embedded
kcmil Strands AWG Conductor Insulation Insulation Jacket Conductor Neutral Jacket Jacket
Full 2/0 19 20 12 0.406 1.090 1.190 1.505 0.411 0.463 1.414 1.522
Neutral 3/0 19 25 12 0.456 1.140 1.240 1.620 0.518 0.579 1.653 1.760
4/0 19 20 10 0.512 1.195 1.295 1.720 0.653 0.741 1.992 2.099
1/0 19 9 14 0.362 1.045 1.145 1.430 0.326 0.131 .999 1.102
2/0 19 11 14 0.406 1.090 1.190 1.475 0.411 0.160 1.139 1.244
3/0 19 14 14 0.456 1.140 1.240 1.520 0.518 0.203 1.316 1.423
4/0 19 11 12 0.512 1.195 1.295 1.575 0.653 0.255 1.576 1.707
One-Third 250 37 13 12 0.558 1.250 1.350 1.640 0.772 0.301 1.799 1.971
Neutral
350 37 12 10 0.661 1.355 1.455 1.845 1.080 0.441 2.269 2.427
500 37 17 10 0.789 1.480 1.580 2.045 1.544 0.624 3.177 3.337
750 61 25 10 0.968 1.670 1.770 2.255 2.316 0.918 4.300 4.531
1000 61 26 9 1.117 1.815 1.920 2.600 3.088 1.212 5.435 5.671
www.eescable.com 215
28kV Aluminum Conductor
90°C (100% – .280 in.)
Concentric Cable Medium Voltage
Underground Residential
Distribution Cable (URD)
28kV Aluminum Conductor 90°C
(100% – .280 in.)
• Conductor – Compact Aluminum
• Conductor Shield – Semiconducting Layer Concentric Insulation Conductor
Jacket Wires Shield Shield
• Insulation – TRXLPE Insulation
• Insulation Shield – Semiconducting Layer Conductor
• Concentric Wires – One-Third and Full Neutral
• Jacket – Nonconducting Polyethylene (LLDPE) with 3 Red
Stripes, Semiconducting Available
Diameter(mm/in)
Conductor CopperNeutral (per CSA C68.5 AppendixC) Weight(lbs/ft)
www.eescable.com 216
28kV Aluminum Conductor
90°C (100% – .280 in.)
Concentric Cable Medium Voltage
Underground Residential
Distribution Cable (URD)
28kV Aluminum Conductor 90°C
(100% – .280 in.)
• Conductor – Compressed Aluminum
• Conductor Shield – Semiconducting Layer Concentric Insulation Conductor
Jacket Wires Shield Shield
• Insulation – TRXLPE Insulation
• Insulation Shield – Semiconducting Layer Conductor
• Concentric Wires – One-Third and Full Neutral
• Jacket – Nonconducting Polyethylene (LLDPE) with 3 Red
Stripes, Semiconducting Available
Diameter(mm/in)
Conductor CopperNeutral (per CSA C68.5 AppendixC) Weight(lbs/ft)
www.eescable.com 217
15 kV .175" TRXLPE Concentric
neutral underground cable
Concentric Cable Medium Voltage
Electrical Data
.175" TRXLPE 15kV concentric neutral underground cable, 100% insulation thickness,
compressed stranding and solid conductors.
Inductive Ampacity – 20°CAmbient
Conductor CopperNeutral Resistance DC Reactance 100% LF, RHO-90
Aluminum OHMSper 1000'
AWGor Numberof Numberof @ 90°C OHMSper 1/CDirect 1/CDuct 1/CDuct
SizeAWG
kcmil Strands Wires 1000' Buried Buried In Air
2 SOLID 10 14 .3280 .032 170 115 100
2 7 10 14 .3360 .030 170 115 100
1 SOLID 13 14 .2600 .030 195 140 123
1 19 13 14 .2650 .029 195 140 123
Full 1/0 SOLID 16 14 .2060 .028 230 155 135
Neutral
1/0 19 16 14 .2110 .028 230 155 135
2/0 19 13 12 .1670 .025 270 185 162
3/0 19 16 12 .1320 .024 295 210 184
4/0 19 20 12 .1050 .023 335 240 210
OHMS to 3/C Direct
3/CTriplex 3/CDuct
Neutralper Buried 8"
in Duct In Air
1000' Spacing
1/0 SOLID 6 14 .2060 .102 230 165 145
1/0 19 6 14 .2110 .099 230 165 145
2/0 19 7 14 .1670 .097 250 190 167
3/0 19 9 14 .1320 .094 280 215 189
4/0 19 11 14 .1050 .092 320 245 215
One-Third
Neutral 250 37 13 14 .0890 .089 345 270 237
350 37 11 12 .0635 .085 405 325 285
500 37 16 12 .0445 .082 460 385 338
750 61 15 10 .0296 .077 515 475 417
1000 61 20 10 .0222 .074 565 540 475
www.eescable.com 218
15kV .220" TRXLPE concentric
neutral underground cable
Concentric Cable Medium Voltage
Electrical Data
.220" TRXLPE 15kV concentric neutral underground cable, 133% insulation thickness,
compressed stranding and solid conductors.
www.eescable.com 219
25kV .260" TRXLPE concentric
neutral underground cable
Concentric Cable Medium Voltage
Electrical Data
.260" TRXLPE 25kV concentric neutral underground cable, 100% insulation thickness,
compressed stranding and solid conductors.
www.eescable.com 220
35kV .345" TRXLPE concentric
neutral underground cable
Concentric Cable Medium Voltage
Electrical Data
.345" TRXLPE 35kV concentric neutral underground cable, 100% insulation thickness,
compressed stranding and solid conductors.
www.eescable.com 221
6381 Y 450/750
V & 0.6/1 KV
6381Y-RVV
BS6004
Conductor: Class 5Copper / Insulation:PVC
Sheath:PVC
Section
InsulationThickness SheathThickness OverallDiameter CableWeight ElectricalResistance
No.xmm2 ClassofConductor °
mm kg/km DC.2OC
mm mm
Ω/km
450/750V
1.5 s 0.9 0.8 4.91 38 13.3
2.5 s 0.9 0.8 5.4 49 7.98
4 5 1 0.9 6.25 71 4.95
6 5 1.1 0.9 7.6 101 3.30
10 s 1.2 1.1 8.56 152 1.91
16 5 1.2 1.1 9.8 215 1.21
25 5 1.4 1.1 115 307 0.78
35 5 1.4 1.1 125 405 O.554
so s 1.4 1.4 15.1 580 0.386
0.6/1KV
70 s 1.4 1.4 17.0 769 0.272
95 5 1.6 1.5 19.1 1008 0.210
120 5 1.6 1.8 21.6 1282 0.164
150 s 1.8 1.8 23.4 1571 0.132
185 5 2 1.8 25.5 1895 0.108
240 5 2.2 1.8 285 2435 0.081
300 5 2.4 2 31.2 3050 0.065
400 5 2.6 2.1 35.3 4035 0.050
www.eescable.com 222
Flat Cable 300/500 V
Flat Cable-BVVB
IEC 60227
Conductor: Class 1/2 Copper
■ Insulation: PVC
■ Sheath: PVC
Secion Insulation Thickness Sheath Thickness Overall Diameter CableWeight Electrical Resistance
www.eescable.com 223
H03VV-F 300/300 V &
HOSVV-F 300/500 V
H03VV-F & H05VV-F(RVV)
HD 21.5
Conductor: Class 5Copper Insulation: PVC Sheath: PVC
Secion Insulation Thickness SheathThickness Overall Diameter Cable Weight Electrical Resistance
Class of Conductor mm DC.200c
No.xmm2 mm mm kg/km Ω /km
H03VV-F 300/300
V
HO5W-F 300/500V
www.eescable.com 224
H05V-K 300/500 V & HO7V-K/2491
X/N07V-K/NYAF 450/750 V
H05V-K&H07V-K&N07V-K(Flexible 5 CU PVC)
www.eescable.com 225
H05V-R 300/500 V & H07V-R/6491
X/NYA 450/750 V
H05V-R&H07V-R&NYA(Stranded 2 CU PVC)
Application
The products are suitable for installation indoors, in cable ducts and in industrial plants or
switching stations, under ground installation.
www.eescable.com 226
H05V-U 300/500 V & H07V-
U/NYA 450/750 V
H05V-U& H07V-UNYA(Solid CU PVC)
www.eescable.com 227
H05Z-K 300/500 V & H07Z-
K 450/750 V
H05Z-K& H07Z-K(Flexible 5 CU LSZH)
Insulation Thickness
H05Z-K 300/500 V
www.eescable.com 228
H05Z-R/6491 B
450/750 V
H07Z-R-6491B(Stranded 2 CU LSZH)
kg/km
www.eescable.com 229
H07Z-U 450/750 V
H07Z-U(Solid CU LSZH)
www.eescable.com 230
SER Aluminum Service
Entrance Cable
SER Aluminum Service Entrance Cable
Insulated
Cond(s) Size Amps in
BareConductor NominalOD Approx.Weight Amps at
Partnumber (AWG/KCM Dwellin
Size(AWG) (inches) (lbs/1000’) 90°C
) g
Two Conductor SERplus BareGround
8-02ALUMG-SER 8 8 0.559 109 45 N/A
6-02ALUMG-SER 6 6 0.630 148 55 N/A
4-02ALUMG-R-SER 4 6 0.720 191 75 N/A
4-02ALUMG-SER 4 4 0.720 206 75 N/A
2-02ALUMG-R-SER 2 4 0.831 270 100 100
2-02ALUMG-SER 2 2 0.831 293 100 100
1-02ALUMG-SER 1 1 0.937 369 115 110
1/0-02ALUMG-R-SER 1/0 2 1.016 407 135 125
1/0-02ALUMG-SER 1/0 1/0 1.016 443 135 125
2/0-02ALUMG-R-SER 2/0 1 1.094 489 150 150
2/0-02ALUMG-SER 2/0 2/0 1.094 535 150 150
4/0-02ALUMG-R-SER 4/0 2/0 1.291 720 205 200
4/0-02ALUMG-SER 4/0 4/0 1.291 794 205 200
Three Conductor SERplus BareGround
8-03ALUMG-SER 8 8 0.606 143 45 N/A
6-03ALUMG-SER 6 6 0.689 195 55 N/A
4-03ALUMG-R-SER 4 6 0.776 257 75 N/A
2-03ALUMG-R-SER 2 4 0.902 365 100 100
1-03ALUMG-R-SER 1 3 1.020 461 115 110
1/0-03ALUMG-R-SER 1/0 2 1.106 556 135 125
2/0-03ALUM-R-SER 2/0 1 1.197 668 150 150
3/0-03ALUMG-R-SER 3/0 1/0 1.307 809 175 175
4/0-03ALUMG-R-SER 4/0 2/0 1.421 987 205 200
250-03ALUMG-R-SER 250 3/0 1.601 1202 230 225
300-03ALUMG-R-SER 300 4/0 1.740 1350 260 250
Four Conductor SERplus BareGround
2-04ALUMG-R-SER 2 4 1.043 465 100 100
2/0-04ALUMG-R-SER 2/0 1 1.398 853 150 150
4/0-04ALUMG-R-SER 4/0 2/0 1.673 1262 205 200
250-04ALUMG-R-SER 250 3/0 1.805 1485 230 225
Application: Aluminum SER cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits.
Maximum operating temperature is not to exceed 90°C in wet locations. Voltage rating is 600 volts.
Conductors: Compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801
Insulation: Type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum alloy ground.
www.eescable.com 231
SEU Aluminum Service
Entrance Cable
SEU Aluminum Service Entrance Cable
Insulated
BareConductor NominalOD Approx.Weight Amps at Amps in
Partnumber Cond(s) Size
Size(AWG) (inches) (lbs/1000’) 90°C Dwellin
(AWG/KCM
g
)
Two Conductor SERplus BareGround
8-02ALUMG-SER 8 8 0.559 109 45 N/A
6-02ALUMG-SER 6 6 0.630 148 55 N/A
4-02ALUMG-R-SER 4 6 0.720 191 75 N/A
4-02ALUMG-SER 4 4 0.720 206 75 N/A
2-02ALUMG-R-SER 2 4 0.831 270 100 100
2-02ALUMG-SER 2 2 0.831 293 100 100
1-02ALUMG-SER 1 1 0.937 369 115 110
1/0-02ALUMG-R-SER 1/0 2 1.016 407 135 125
1/0-02ALUMG-SER 1/0 1/0 1.016 443 135 125
2/0-02ALUMG-R-SER 2/0 1 1.094 489 150 150
2/0-02ALUMG-SER 2/0 2/0 1.094 535 150 150
4/0-02ALUMG-R-SER 4/0 2/0 1.291 720 205 200
4/0-02ALUMG-SER 4/0 4/0 1.291 794 205 200
Three Conductor SERplus BareGround
8-03ALUMG-SER 8 8 0.606 143 45 N/A
6-03ALUMG-SER 6 6 0.689 195 55 N/A
4-03ALUMG-R-SER 4 6 0.776 257 75 N/A
2-03ALUMG-R-SER 2 4 0.902 365 100 100
1-03ALUMG-R-SER 1 3 1.020 461 115 110
1/0-03ALUMG-R-SER 1/0 2 1.106 556 135 125
2/0-03ALUM-R-SER 2/0 1 1.197 668 150 150
3/0-03ALUMG-R-SER 3/0 1/0 1.307 809 175 175
4/0-03ALUMG-R-SER 4/0 2/0 1.421 987 205 200
250-03ALUMG-R-SER 250 3/0 1.601 1202 230 225
300-03ALUMG-R-SER 300 4/0 1.740 1350 260 250
Four Conductor SERplus BareGround
2-04ALUMG-R-SER 2 4 1.043 465 100 100
2/0-04ALUMG-R-SER 2/0 1 1.398 853 150 150
4/0-04ALUMG-R-SER 4/0 2/0 1.673 1262 205 200
250-04ALUMG-R-SER 250 3/0 1.805 1485 230 225
Application: Aluminum SER cable is primarily used as panel feeder in multiple unit dwellings and for branch circuits.
Maximum operating temperature is not to exceed 90°C in wet locations. Voltage rating is 600 volts.
Conductors: Compact strand soft drawn 8000 series aluminum conductor, per ASTM B-801
Insulation: Type XHHW-2 cross linked polyethylene (XLP) insulation. The conductors are cabled together with a bare aluminum alloy ground.
www.eescable.com 232
AGR Silicone Wire
Silicone Wire
l Rated Voltage:500V
l Rated Temperature:-60°C~+200°C
Composition:
Application:
www.eescable.com 233
Aluminum THHN/THWN-2/T90
600V PVC/Nylon Insulation
THHN-THWN-2
APPLICATION: JACKET:
THHN / THWN-2 / T90 cables are primarily used for power • A clear abrasion, heat, moisture resistant and low coefficient of
distribution. The cables may be used in wet or dry locations, friction nylon jacket. Standard stock colors include: black, red,
with conductor temperatures not exceeding 90°C. Voltage blue, white, brown, orange, yellow, gray, purple and green
rating for cable is 600V.
STANDARDS:
CONDUCTORS:
• UL 83, UL 1685,cUL
• Compact bare AA-8000 series aluminum, with Class B • CSA C22.2 No. 75
stranded per ASTM • 1/0 & larger are rated for CT use
• Requirements of the National Electrical Code
INSULATION: • NEMA WC-70 / ICEAS-95-658
• Low coefficient of friction (“slick”), abrasion, heat and • ASTM B800, B801, B836
moisture resistant Polyvinyl Chloride (PVC) • VW-1/FT1
www.eescable.com 234
COPPER
THHN/THWN-2
THHN-THWN-2
Copper THHN/THWN-2
Application: Copper THHN/THWN-2 conductors are primarily used in conduit and cable trays, when approved, for
services, feeders and branch circuits in commercial or industrial applications as specified in the National
Electric Code. THHN applications are suitable for use in dry locations only at temperatures not to exceed
90°C. THHN-2 applications are suitable for use in either wet or dry applications, with temperatures that do
not exceed 90°C.
Conductors: Either solid or stranded soft drawn copper, per ASTM Standards.
Insulation: Heat and moisture resistant colored polyvinyl chloride (PVC) insulation, with a clear nylon (polyamide) or UL-
listed equal jacket, which provides abrasion resistance.
Standards: UL 83
UL VW-1
Size 1/0 & larger suitable for cable tray use
MTW per UL 1063
ASTM B1, B3, B8
Federal Spec A-A-59544
www.eescable.com 235
Twisted Flexible Electric
Wire 450/750 V
Twisted Flexible Electric Wire
The products are suitable for power installation fixed wiring or flexible connection for electrical
applications with rated voltage up to and including 450/750V respectively
www.eescable.com 236
Aluminum XHHW-2
600V, XLPE Insulation
XHHW-2
APPLICATION:
Type XHHW-2 or RW90 wires are primarily use for power
distribution; and are sometimes referred to as feeders. They
may beused in wet or dry locations with conductor temperatures
not exceeding 90°C and may be used in conduit and recognized
raceways as specified in the National Electrical Code. Voltage
rating for XHHW-2 or RW90 conductors is 600V. STANDARDS:
• UL 44 / CSA C22.2 No.38
CONDUCTORS: • ANSI / NEMA WC-70 / ICEAS-95-658
• ASTM B800,B801
• Compact bare AA-8000 series aluminum alloy, Class B
• Sunlight resistant on sizes 6 AWG and larger
stranded per ASTM
INSULATION:
• Abrasion, heat and moisture resistant cross-linked
polyethylene insulation (XLPE), low coefficient of friction,
“slippery” or “slick” material. It is available in ten solid
colors.
www.eescable.com 237
Copper XHHW-2 600V
XLPE Insulation
XHHW-2
Insulation Overall
Size No. of Weight Ampacity*
PartNumber Thickness (mils) Diameter
(AWG/kcmil) Strands lbs./kft (amps)
(inches)
Application: XHHW-2 cables are primarily used for power distribution. The cables may be used in wet or dry locations, with ambient
temperatures not exceeding 90°C. Voltage rating for XHHW-2 cable is 600V.
Conductors: Compressed soft drawn bare copper with class B stranding per ASTM Standards.
Insulation: Abrasion, heat, moisture, and flame resistant cross-linked polyethylene (XLPE) insulation.
Standards: UL 44
Requirements of the National Electrical Code
ASTM standards B3, B8, B787
ICEA S-95-658/NEMA WC-70
Federal Specification A-A-59544
Flame Rated: CT Use (1/0 AWG and larger available upon request)
Temperature Rated at 90°C Wet/Dry, Cold Temperature Rated at -40°C
Sunlight Resistant, Gasoline and Oil Resistant II
RoHS Compliant
www.eescable.com 238
Aluminum RHH/RHW-2/USE-
2 600V 90°C XLPE insulation
XLP USE RHH-RHW-2
Aluminum RHH/RHW-2/USE-2
600V 90°C XLPE insulation
All values are nominal and subject to correction
Size
Conductor Insulation Overall
PWC AWG Diameter Thickness Diameter Weight Ampacity
Stranding
Part Number /KC lbs/1000' at 90C *
(inches) (inches) (inches)
M
8-01XL-USE-2-ALUM 8 7 0.134 0.060 0.257 36 45
6-01XL-USE-2-ALUM 6 7 0.169 0.060 0.292 49 55
4-01XL-USE-2-ALUM 4 7 0.213 0.060 0.336 65 75
3-01XL-USE-2-ALUM 3 7 0.240 0.060 0.368 78 85
2-01XL-USE-2-ALUM 2 7 0.268 0.060 0.391 94 100
1-01XL-USE-2-ALUM 1 18 0.299 0.080 0.462 126 115
1/0-01XL-USE-2-ALUM 1/0 18 0.335 0.080 0.499 151 135
2/0-01XL-USE-2-ALUM 2/0 18 0.378 0.080 0.539 182 150
3/0-01XL-USE-2-ALUM 3/0 18 0.423 0.080 0.586 221 175
4/0-01XL-USE-2-ALUM 4/0 18 0.476 0.080 0.638 269 205
250-01XL-USE-2-ALUM 250 35 0.520 0.095 0.713 326 230
300-01XL-USE-2-ALUM 300 35 0.571 0.095 0.763 381 260
350-01XL-USE-2-ALUM 350 35 0.614 0.095 0.809 435 280
400-01XL-USE-2-ALUM 400 35 0.657 0.095 0.852 489 305
500-01XL-USE-2-ALUM 500 35 0.736 0.095 0.929 595 350
750-01XL-USE-2-ALUM 750 58 0.909 0.110 1.131 881 435
1000-01XL-USE-2-
ALUM 1000 58 1.059 0.110 1.283 1145 500
Application: USE-2 cables are primarily used for power distribution, in raceways in accordance with National Electrical Code, except that the
cable is not rated for use in cable tray. USE-2 is approved for direct burial and for service entrance below ground. USE-2 cables may
be used in wet or dry locations, with conductor temperatures not exceeding 90 C. Voltage rating for USE-2 cable is 600V.
Conductors: Compact soft drawn bare 8000 series aluminum, with Class B stranding per ASTM
Insulation: Abrasion, heat and moisture resistant cross-linked polyethylene insulation XLPE
www.eescable.com 239
ASTM STANDARD
XLP USE RHH-RHW-2
Copper RHH/RHW-2/USE-2
600V 90°C XLPE Insulation
Insulation Overall
Part Size No. of Weight Ampacity**
Thickness(mils) Diameter
Number (AWG/kcmil) Strands lbs./kft (amps)
(inches)
14-01XLP-USE 14* 7 45 0.163 21 25
12-01XLP-USE 12 7 45 0.182 30 30
10-01XLP-USE 10 7 45 0.205 43 40
8-01XLP-USE 8 7 60 0.263 69 55
6-01XLP-USE 6 7 60 0.301 103 75
4-01XLP-USE 4 7 60 0.350 156 95
2-01XLP-USE 2 7 60 0.404 238 130
1-01XLP-USE 1 19 80 0.476 307 145
1/0-01XLP-USE 1/0 19 80 0.517 384 170
2/0-01XLP-USE 2/0 19 80 0.562 476 195
3/0-01XLP-USE 3/0 19 80 0.610 590 225
4/0-01XLP-USE 4/0 19 80 0.669 735 260
250-01XLP-USE 250 37 95 0.762 868 290
350-01XLP-USE 350 37 95 0.866 1192 350
500-01XLP-USE 500 37 95 0.986 1673 430
750-01XLP-USE 750 61 110 1.205 2493 520
1000-01XLP-USE 1000 61 110 1.370 3292 615
Application: USE-2 cables are primarily used for power distribution and may be installed in raceway, conduit, direct burial, and aerial
installations. The cables may be used in wet or dry locations, with ambient temperatures not exceeding 90°C. Voltage
rating for USE-2 cable is 600V. Sizes 1/0 and larger rated for use in cable tray.
Conductors: Soft drawn bare copper with Class B stranding per ASTM.
Insulation: Abrasion, heat, moisture, and flame resistant cross-linked polyethylene (XLPE) insulation.
www.eescable.com 240
H07RN-F
Rubber Cable
2
Nominal conductor area mm and Approx. overall Approx. weight
Part No.
number of cores Ø mm kg/km
2
G-022938 16mm 1 core 11.1 248
2
G-022940 25mm 1 core 12.9 356
2
G-022944 35mm 1 core 14.3 476
2
G-022945 50mm 1 core 16.8 657
2
G-022946 70 mm 1 core 19.0 884
2
G-023032 95 mm 1 core 21.9 1156
2
G-023033 120mm 1 core 23.4 1420
2
G-023034 150mm 1 core 26.0 1762
2
G-023035 185mm 1 core 29.1 2145
2
G-023036 240mm 1 core 31.2 2720
2
G-023028 1mm 2 core 7.9 89
2
G-023029 1.5mm 2 core 8.9 116
2
G-023030 2.5mm 2 core 10.6 167
2
G-023041 4mm 2 core 12.8 227
2
G-023042 6mm 2 core 15.0 390
www.eescable.com 241
H07RN-F
Rubber Cable
2
Nominal conductor area mm and Approx. overall Approx. weight
Part No.
number of cores Ø mm kg/km
2
G-023011 1mm 2 core + earth 8.5 107
2
G-023012 1.5mm 2 core + earth 9.5 137
2
G-023013 2.5mm 2 core + earth 11.3 202
2
G-023014 4mm 2 core + earth 13.8 292
2
G-023015 6mm 2 core + earth 15.0 390
2
G-023016 10mm 2 core + earth 20.2 684
2
G-023017 16mm 2 core + earth 23.1 944
2
G-022879 1mm 3 core + earth 9.4 131
2
G-022880 1.5mm 3 core + earth 10.4 167
2
G-022981 2.5mm 3 core + earth 12.5 247
2
G-022982 4mm 3 core + earth 14.3 340
2
G-022983 6mm 3 core + earth 16.3 463
2
G-022984 10mm 3 core + earth 22.1 831
2
G-022985 16mm 3 core + earth 25.3 1166
2
G-022986 25mm 3 core + earth 30.1 1711
2
G-022987 35mm 3 core + earth 32.5 2190
2
G-022988 50mm 3 core + earth 37.8 3101
2
G-022989 70mm 3 core + earth 44.2 4143
2
G-022990 95mm 3 core + earth 49.6 5517
2
G-022991 120mm 3 core + earth 54.4 6611
2
G-022992 150mm 3 core + earth 60.9 8244
2
G-022993 185mm 3 core + earth 68.2 10113
2
G-022994 240mm 3 core + earth 74.1 12838
2
G-022910 1.5mm 4 core + earth 11.5 206
2
G-022951 2.5mm 4 core + earth 13.7 304
2
G-022952 4mm 4 core + earth 15.9 426
2
G-022953 6mm 4 core + earth 18.1 579
2
G-022954 10mm 4 core + earth 24.3 1024
2
G-022955 16mm 4 core + earth 28.7 1440
2
G-022956 25mm 4 core + earth 33.3 2105
2
G-024457 35mm 4 core + earth 36.2 2618
2
G-024459 50mm 4 core + earth 43.9 3730
2
G-024460 70mm 4 core + earth 49.5 4985
2
G-025754 95mm 4 core + earth 57.5 6765
2
G-029183 120mm 4 core + earth 60.5 7920
2
G-027746 150mm 4 core + earth 67.5 9800
2
G-029184 185mm 4 core + earth 75.9 12040
2
G-022973 1.5mm 6 core + earth 15.7 339
2
G-022974 2.5mm 6 core + earth 18.3 482
2
G-022975 1.5mm 11 core + earth 19.1 497
2
G-022976 2.5mm 11 core + earth 22.3 707
2
G-022977 1.5mm 17 core + earth 22.3 700
www.eescable.com 242
WELDING CABLE
Rubber Cable
CONSTRUCTION:
Ø CONDUCTOR: 6 AWG- 4/0AWG Stranded bare copper flexible, fully
annealed, Class K, Bare-copper.
Ø INSULATION: Chlorinated Polyethylene (CPE) Lead free
COLOR: Black
Nominal Nominal
Conductor Weight per
Conductor Insulation Overall Nom. DCR
Stranding 1000 ft.
Thickness Diameter
www.eescable.com 243
NETWORKING DATA
CABLES
Control Cable
www.eescable.com 244
Instrumentation,
Signal Cables
Control Cable
EES
www.eescable.com 245
Instrumentation,
Signal Cables
Control Cable
www.eescable.com 246
Instrumentation,
Signal Cables
Control Cable
www.eescable.com 247
Winding Wire PVC Insulated
for Submersible Pump Motors
Control Cable
EES
EES
www.eescable.com 248
CONTROL CABLE
Control Cable
EES
www.eescable.com 249
CONTROL CABLE
Control Cable
EES
www.eescable.com 250
ASTM/ ICE/ EN
SOLAR CABLE
Application
Cable construction
www.eescable.com 251
ASTM STANDARD
SOLAR CABLE
Min.
Diameter of Insulation Nominal Maximum conductor
Size Number of Net Weight
conductor Thickness O.D. resistance at 20ºC
Strands
AWG
mm mm mm kg/km Ω/km
or kcmil n
12 2.16 7 1.90 6.0 46 8.880
10 2.72 7 1.90 6.5 56 5.590
8 3.40 7 2.15 7.7 80 3.520
6 4.29 7 2.15 8.6 102 2.210
4 5.41 7 2.15 9.7 135 1.390
3 6.02 7 2.15 10.3 156 1.100
2 6.81 7 2.15 11.1 183 0.875
1 7.59 18 2.66 12.9 244 0.693
1/0 8.53 18 2.66 13.9 286 0.550
2/0 9.55 18 2.66 14.9 337 0.436
3/0 10.74 18 2.66 16.1 400 0.346
4/0 12.07 18 2.66 17.4 477 0.274
250 13.21 35 3.04 19.3 579 0.232
300 14.48 35 3.04 20.6 665 0.194
350 15.65 35 3.04 21.7 750 0.166
400 16.74 35 3.04 22.8 836 0.145
450 17.78 35 3.04 23.9 914 0.129
500 18.69 35 3.04 24.8 1028 0.116
550 19.69 58 3.43 26.6 1133 0.1060
600 20.65 58 3.43 27.5 1217 0.0967
650 21.46 58 3.43 28.3 1298 0.0893
700 22.28 58 3.43 29.1 1382 0.0829
750 23.06 58 3.43 29.9 1463 0.0774
800 23.83 58 3.43 30.7 1543 0.0725
900 25.37 58 3.43 32.2 1707 0.0645
1000 26.92 58 3.43 33.8 1871 0.0580
www.eescable.com 252