NE-Q05 (P) : Instruction Manual

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

96M11365 Precautions on Regulations and Standards

„ CE Marking
KEYENCE Corporation has confirmed that this product complies with the essential
requirements of the applicable EC Directive, based on the following specifications. Be sure to

Ethernet Switch
consider the following specifications when using this product in the Member State of European
Union.

z EMC Directive (2004/108/EC)

NE-Q05(P) •

Applicable standard EMI: EN55011, Class AEMS; EN61000-6-2
When installing the NE-Q05(P), it must be installed in an conductive enclosure
(industrial control panel) with IP54 or higher.
• Use a shielded cable for the signal lines located outside of the conductive enclosure
(industrial control panel). The shielded cable must be grounded.

Instruction Manual • Be sure to use the functional earthing terminal on the unit for grounding.

Remarks:
These specifications do not give any guarantee that the end-product with this product
incorporated complies with the essential requirements of EMC Directive. The
manufacturer of the end-product is solely responsible for the compliance on the
end-product itself according to EMC Directive.
Read this manual before use.
Keep this manual in a safe place for future reference. „ UL Certificate
This product is an UL/C-UL Listed product.
• UL File No. E207185
Introduction • Category NRAQ, NRAQ7

This manual describes handling, operation, and safety information for the NE-Q05(P). Be sure to consider the following specifications when using this product as an UL/C-UL Listed
Read this manual thoroughly in order to take full advantage of product performance, and use Product.
the product only after fully understanding its contents. • For wiring to the power supply connector, use a power supply with Class 2 output defined in
Take care to store this manual in a convenient location so that it is readily accessible for NFPA70 (NEC: National Electric Code).
reference whenever necessary. • For wiring to the power supply connector, use the AWG 16 to 18 copper wire with tempera-
Please take care that the personnel who will actually operate the product have access to this ture rating 60 °C or more.
manual.Ensure that this manual is accessible by the end users. • Use this product under pollution degree 2.
• This product is an open type device. Therefore, it must be installed in an enclosure with
„ Safety Information for NE-Q05(P) Series IP54 or higher. (e.g. Industrial control panel)

z Symbols Outline
This manual uses the following headings to make important sections easy to notice and
understand. Always read these sections. The "Ethernet switch NE-Q05 (P)" is a five-port Ethernet switch in order to connect the
Ethernet/IP equipment and the Ethernet equipment. NE-Q05 (P) supports the QoS function,
It indicates a hazardous situation which, if not avoided, will result and the PoE function (NE-Q05P only).
DANGER in death or serious injury. • By using the QoS function, the NE-Q05 (P) can transfer cyclic communication data (Implicit
It indicates a hazardous situation which, if not avoided, could message) of the Ethernet/IP equipment preferentially.
WARNING result in death or serious injury. • By using the PoE (Power over Ethernet) function, the NE-Q05 (P) can also supply the PoE
power receiving equipment which is in conformity with IEEE802.3af using the LAN cable.
It indicates a hazardous situation which, if not avoided, could
CAUTION (NE-Q05P only)
result in minor or moderate injury.
It indicates a situation which, if not avoided, could result in • The following KEYENCE PoE power receiving equipment does not
NOTICE product damage as well as property damage. support IEEE802.3af. Even though the equipment is connected to
the NE-Q05P, the PoE function cannot be used.
Important It indicates cautions and limitations that must be followed during
operation. [NE-W11]
NOTICE • The following KEYENCE PoE power sourcing equipment does not
Point It indicates additional information on proper operation. support IEEE802.3af. Do not connect the NE-Q05P after the PoE
function is enabled. Doing so may damage the device.
Reference It indicates tips for better understanding or useful information. [NE-V08], [DT-100A], [DT-500]

z General Precautions
• Verify that this device is operating normally in terms of functionality and performance
Checking the Package Contents
before the start of work and when operating the device.
• Be aware that the product functions and performance are not warranted if the product is Before using the NE-Q05(P), make sure that the following equipment and accessories are
used outside the range of stated specifications or is modified by the customer. included in the package. We have thoroughly inspected the package contents before
• Combining this product with other equipment requires sufficient consideration because shipment.
the proper functions and performance may not be provided depending on the However, in the event of defective or broken items, contact your nearest KEYENCE office.
environment.
• Do not use this product for the purpose to protect a human body or a part of human „ Package contents
body.
NE-Q05(P) main unit x1 Power supply connector x1
• This product is not intended for use as explosion-proof product. Do not use this product
in hazardous location and/or potentially explosive atmosphere.
• Mount the NE-Q05(P) as far away as possible from power lines or high-voltage lines.
Noise from power lines and high-voltage lines may cause the NE-Q05(P) to
malfunction.

• Do not lay cables during lightning. Lightning may cause electric


shock.
WARNING • Do not build a network using this device that may adversely
affect human life or damage equipment.

• Do not touch the Ethernet ports with a pen, screwdriver or other


fine-tipped object. Doing so might scratch or damage the
Ethernet ports.
NOTICE • Do not subject this device to impact, or exert more than
necessary force when inserting the STP/UTP cables into the
Ethernet ports. Doing so might damage the Ethernet
ports.Failure to observe may result in injury.

1
Names of Each Part and Functions „ Connection to the terminal block
The procedure to connect electrical wires to the terminal block are as follows:
„ Front view „ Side view
1 Remove the terminal block from the controller.
POWER
(2) Loosen the two screws with a screwdriver and pull
out the terminal block.
LINK 100M
1
(3)
(4)
LINK 100M
2
A power connector is removed and
Reference
3
LINK 100M packed when the unit is shipped
(1) from the factory.
LINK 100M
4

2
PoE
(5)
5
LINK 100M
Use a screwdriver to push in part (A) and
PoE
insert a lead wire into part (B) as indicated.
A
NE-Q05P

24V DC
0V (6) 3 Remove the screwdriver once the wire is fully
inserted. B
Pull each lead wire gently to confirm that it is
properly secured.
Name Description
10 Base-T/100 Base-TX Ethernet port For NE-Q05(P),
(1) Ethernet port
ports 4 and 5 are targeted for the PoE function.
Lit in green: Power ON
4 Attach the terminal block to the controller.
(2) Power LED
Out: Power OFF
Lit in green: Communications at 100 Mbps in progress
(3) 100M LED
Out: Communications at 10 Mbps in progress
Lit in green: Link ON
(4) LINK LED Blinking in green: Data transmission in progress
Out: Link OFF
Lit in orange: Power supply ON
(5) PoE LED*
Out: Power supply OFF „ Grounding precautions
(6) Power supply connector Power supply connector for 24V DC input. • Provide an exclusive ground of class D earth (maximum resistance of 100 Ohms) when
grounding the shielded lead on the earth terminal.
* When the NE-Q05P is used • If an exclusive ground cannot be obtained, share the ground with another device.

Ethernet Port I/O Specifications Body


dy
O
Other
Body
dy
O
Other
Body
y
Ot
Other
d
dev
device dev
device d
device
„ Pin assignment table (Ethernet)

Pin No. MDI-X MDI


1 RD+ TD+ Class D earth Class D earth
2 RD– TD– Max. resistance of 100 Ω Max. resistance of 100 Ω
(8) (1) 3 TD+ RD+ • Keep the grounding point as close as possible to the NE-Q05(P), and keep the ground lead
as short as possible.
RJ-45 modular connector 4 – –
• If the ground lead must be extended, use thick insulating cable, and pass the ground lead
* View from outside of NE-Q05(P) 5 – – through a duct before grounding.
6 TD– RD–
7 – – Installation
8 – –
This section describes how to attach and remove the Ethernet Switch to and from the DIN rail.
RD: Receive data TD: Send data
„ Mounting the Ethernet Switch

Item
10BASE-T
NE-Q05(P)
100BASE-TX
1 Hold the Ethernet Switch mounting claw
onto the upper groove on the DIN rail.
Compliant standards IEEE802.3, IEEE802.3u, IEEE802.3x
Baud rate 10 Mbit/s 100 Mbit/s

*1
Category 3 or higher UTP or Category 5 or higher UTP or
Transmission medium
STP STP
Max. cable length 100 m
*1 STP: Shielded Twist Pair cable
UTP: Unshielded Twist Pair cable

Important When using the PoE function of the NE-Q05P and supply the power
to the power receiving function, be sure to use the STP cable or the
UTP cable with the category of five or higher.
2 Fit the lower side of the DIN rail into the
DIN rail mounting claw on the lower side
of the Ethernet switch.
Power Connection and Ground • The lower black claw is designed to move
by a spring. Press against the claw until
you hear it click into place.
„ Connecting the Power Supply • At locations where it is difficult to mount
Connect the 24 VDC power supply to terminals 1 and 2 of the 3-pin terminal block. the Ethernet Switch, remove all locks,
mount the Ethernet Switch on the DIN rail,
Be sure to observe the following instructions. Otherwise, a and then lock.
connection failure may occur, causing a malfunction in the products.
• For the power supply cable, use lead wires with a nominal 3 Make sure that the DIN rail mounting claw
cross-section area of 0.8 mm2 to 1.3 mm2 (AWG16 to 18). on the lower side is pressed in (locked).
• The unsheathed wire length should be approx. 9 mm.
NOTICE • Do not use soldering (preliminary soldering) to connect the wires.
• Insert the wires into the innermost position of the terminal block
securely.
• Connect the wires to the terminal block directly, without using a
crimp terminal, etc.

Locked Unlocked

2
„ Removing the Ethernet Switch PoE (Power over Ethernet) function(NE-Q05P)
1 Draw out the lower side DIN rail mounting claw PoE (Power over Ethernet) of the NE-Q05P is a function that supplies the power via the STP
downwards. cable or the UTP cable with category five or higher to the PoE power receiving equipment
which is in conformity with IEEE802.3af.
2 Remove the Ethernet Switch from the DIN rail by
• The port which supports the PoE function: 2 ports
following the mounting procedure in reverse. • Available power supply: 15.4 W/1 port
• Possible to supply the power to the PoE power receiving equipment which is in conformity
with IEEE802.3af
Unlocked

Installation cautions POWER

LINK 100M

„ Installation environment LINK 100M

Do not install NE-Q05(P) in the following locations: Power supply PoE power receiving
LINK 100M

• Locations where the device is exposed to direct sunlight.


equipment which is in
• Locations where the surrounding air temperature range exceeds 0 to +50°C.
conformity with
LINK 100M

• Locations where relative humidity exceeds 10 to 95% RH.


IEEE802.3af
PoE

• Locations subject to condensation due to rapid change in temperature. LINK 100M

• Locations where corrosive or flammable gases are present. PoE

• Locations where there is excessive dust, salt, iron powder, or soot. NE-Q05P

• Locations where series devices are subject to direct vibrations or mechanical shocks.
• Locations where series devices are exposed to splashes of substances such as water, oil,
24V DC
0V

or chemical agents.
• Locations where strong magnetic or electrical fields are generated.
• At altitude of 2,000 m at minimum.

„ Setting orientation
When mounting the Ethernet Switch in a panel, be sure to mount the switch so that the side of
the switch with the Ethernet port is towards you. Important • When using the PoE function of the NE-Q05P and supply the power
to the power receiving function, be sure to use the STP cable or the
Front mount Ceiling mount UTP cable with the category of five or higher.
• When the port which supports the PoE function is connected other
than the PoE power receiving equipment, the port can be used as
same as the other Ethernet port.

• The following KEYENCE PoE power receiving equipment does not


support IEEE802.3af. Even though the equipment is connected to
the NE-Q05P, the PoE function cannot be used.
[NE-W11]
NOTICE • The following KEYENCE PoE power sourcing equipment does not
support IEEE802.3af. Do not connect the NE-Q05P after the PoE
function is enabled. Doing so may damage the device.
[NE-V08], [DT-100A], [DT-500]
Face up Vertical mount

Periodic Maintenance and Inspection Items


„ Maintenance
• If you cannot remove dirt or dust on the NE-Q05(P) by wiping with a soft, dry cloth, wipe
with a firmly wrung cloth moistened with watered down neutral detergent.
• If rubber, vinyl products or adhesive tape are left attached to the NE-Q05(P) for a long
period of time, the NE-Q05(P) may become stained. Remove any of these during cleaning
if attached to the NE-Q05(P).

Inspection Item Inspection Standard


Power Voltage fluctuations on Voltage fluctuation must be within the allowable range.
supply power terminal 24 VDC±10%
„ Distance between surrounding areas
Must be within the operating ambient temperature range.
Be sure to allow at least 30 mm of space at the rear of the Ethernet Switch and between the Ambient temperature
0 to +50°C
switch and other devices. Ambient
environmen Must be within the operating ambient humidity range.
Ambient humidity
t conditions 10 to 95%RH
Dust, dirt, etc. Dirt or dust is not allowed to accumulate.
Loose lock switch The unit must be firmly locked onto the DIN rail.
30 mm
The connector must be completely inserted and
Cable connections
must not be loose.
Mounting The cable must free from abnormalities such as
30 mm conditions State of cables
broken leads.
Ethernet Loose screws on
Bottom:
Switch power supply terminal The screws must not be loose.
Allow 30 mm of space so that
you can insert your fingers block
into the lock lever and unlock
the lever.

30 mm

Top/left:
Allow 30 mm of space for heat to escape.

QoS function
QoS is a function which transfers the communication packet preferentially.
QoS function is included in the NE-Q05(P) in advance, and transfers the communication
packet with the following priority level.

Priority level Description


1 Cyclic communication data of Ethernet/IP communication (Implicit message)
2 IGMP packet
3 Other communication packet

Point QoS function of the NE-Q05(P) is always enable.

3
Specifications Warranty
„ General specifications KEYENCE products are strictly factory-inspected. However, in the event of a failure, contact
your nearest KEYENCE office with details of the failure.
Item Specifications
Power voltage 24 VDC ± 10 % 1. WARRANTY PERIOD
Internal power The warranty period shall be for one year from the date that the product has been deliv-
NE-Q05: 180 mA/NE-Q05P: 2.2 A
dissipation ered to the location specified by the purchaser.
Operating
surrounding air 0 to +50°C* (icing not allowed) 2. WARRANTY SCOPE
temperature (1) If a failure attributable to KEYENCE occurs within the abovementioned warranty
Storage period, we will repair the product, free of charge. However, the following cases shall
-20 to +70°C
temperature be excluded from the warranty scope.
Operating • Any failure resulting from improper conditions, improper environments, improper
surrounding air 10 to 95% RH (no condensation) handling, or improper usage other than described in the instruction manual, the
humidity user’s manual, or the specifications specifically arranged between the purchaser
Voltage AC 1,500 V for 1 min. between power supply terminal and input/output and KEYENCE.
endurance terminals, and between all external terminals and case
• Any failure resulting from factors other than a defect of our product, such as the
Resistance to purchaser’s equipment or the design of the purchaser’s software.
1,500 Vp-p or more Pulse width: 1 μs, 50 ns (from noise simulator)
line noise
• Any failure resulting from modifications or repairs carried out by any person other
Number of
In presence of an intermittent vibration than KEYENCE staff.
sweeps
• Any failure that can certainly be prevented when the expendable part(s) is main-
Frequency Acceleration Amplitude
In tained or replaced correctly as described in the instruction manual, the user’s
10 to 57 Hz – 0.075 mm manual, etc.
conformity 10 times in
Resistance to 57 to 150 Hz 9.8 m/s2 –
with JIS B each of X-, • Any failure caused by a factor that cannot be foreseen at a scientific/technical
vibration
3502 In presence of a continuous vibration Y- and level at the time when the product has been shipped from KEYENCE.
IEC61131-2 Frequency Acceleration Amplitude Z-axes (for • Any disaster such as fire, earthquake, and flood, or any other external factor, such
80 mins.) as abnormal voltage, for which we are not liable.
10 to 57 Hz – 0.035 mm
57 to 150 Hz 4.9 m/s 2 – (2) The warranty scope is limited to the extent set forth in item (1), and KEYENCE
assumes no liability for any purchaser’s secondary damage (damage of equipment,
Shock 150 m/s2 (15 G), working time: 11 ms, twice in each of X, Y and Z axis
resistance direction loss of opportunities, loss of profits, etc.) or any other damage resulting from a failure
of our product.
Insulation 50 MΩ or more (500 VDC mega between power supply terminal and
resistance input/output terminals, and between all external terminals and case) 3. PRODUCT APPLICABILITY
Operating KEYENCE products are designed and manufactured as general-purpose products for
No excessive dust or corrosive gases
atmosphere
general industries.
Altitude during
2,000 m at maximum Therefore, our products are not intended for the applications below and are not applica-
operation
Over voltage ble to them. If, however, the purchaser consults with us in advance regarding the employ-
I ment of our product, understands the specifications, ratings, and performance of the
category
Pollution product on their own responsibility, and takes necessary safety measures, the product
2
degree may be applied. In this case, the warranty scope shall be the same as above.
Weight NE-Q05: approx. 180 g/NE-Q05P: approx. 260 g • Facilities where the product may greatly affect human life or property, such as
* Stipulated by temperature at bottom side of unit inside the control panel nuclear power plants, aviation, railroads, ships, motor vehicles, or medical equip-
ment
„ Functional and performance specifications • Public utilities such as electricity, gas, or water services
• Usage outdoors, under similar conditions or in similar environments
Item Specifications E 1040-1
Data transmission rate 10 Mbps/100 Mbps, full duplex/half duplex automatically supported
Switching function Store-and-forward
MDI/MDI-X
Available
auto-switching function
Auto negotiation function Available
MAC address hold time 300 secs.
Max. number of registrable
2048
MAC addresses
Half duplex: Backpressure
Flow control
Full duplex: Flow control by IEEE802.3x compliant pause packets
QoS function Ethernet/IP cyclic data is controlled preferentially
NE-Q05: N/A
PoE function NE-Q05P: 2 ports Conformity with IEEE802.3af
Power supply: 15.4 W/1 port (DC 44 to 57 V)

Dimensions

7.8
14.9
70

POWER

LINK 100M
36.3

LINK 100M
R2
4

LINK 100M
35.9
110

LINK 100M

PoE

LINK 100M

PoE
NE-Q05P

24V DC
20.8

0V

14 14 3.5
15.9

45 16.1 91.7
3.5

Copyright (c) 2010 KEYENCE CORPORATION. All rights reserved.


11365E 1080-1 96M11365 Printed in Japan
4

You might also like