Instruction Manual: Power Supply Unit KV-PU1
Instruction Manual: Power Supply Unit KV-PU1
Instruction Manual: Power Supply Unit KV-PU1
UL Certificate
This product complies with the following UL and CSA standards and has been certified by UL.
• UL File No. E207185
• Category NRAQ, NRAQ7
• Applicable Standard UL61010-1
UL61010-2-201
CAN/CSA C22.2 No.61010-1
CAN/CSA C22.2 No.61010-2-201
Be sure to consider the following specifications when using this product as a product certified
by UL.
Introduction • The KV-PU1 is open equipment. Therefore, it must be installed in an enclosure with IP54 or
higher. (e.g. Industrial control panel)
This instruction manual describes the handling, operation, and safety information for the KV-PU1 • Use stranded copper wire (twisted wire) with a wire gauge of AWG #12 to #22 and
Power Supply Unit. Read this manual thoroughly in order to take full advantage of the product temperature rating of 105°C or higher when wiring to the terminal block on the KV-PU1. The
features, and use the product only after fully understanding its contents. tightening torque is 1.4 N·m. (12.4 lb.-In)
Be sure to store this manual in a convenient place so that it is readily accessible for reference. • Do not supply power via terminal block on the CPU unit when you use the KV-PU1.
Ensure that the personnel who will actually operate the product have access to this manual.
• Use this product under pollution degree 2.
Safety Precautions • Overvoltage Category Ⅱ
Symbol Guide • Use this product at the altitude of 2000 m or less.
The following symbols are used to show potentially hazardous situations or to provide extra • Indoor use only.
information. Be sure to read this section carefully. • Ensure the circuits to be connected to the output terminals (power supply output, error
Indicates a hazardous situation which, if not avoided, will result in death or output) are SELV circuits.
DANGER
serious injury.
Certificat UL
Indicates a hazardous situation which, if not avoided, could result in death Ce produit est conforme aux normes UL et CSA suivantes et a été certifié par UL.
WARNING
or serious injury.
• Fichier UL No. E207185
Indicates a hazardous situation which, if not avoided, could result in minor
CAUTION
or moderate injury. • Catégorie NRAQ, NRAQ7
Indicates a situation which, if not avoided, could result in product damage • Norme applicable UL61010-1
NOTICE
as well as property damage. UL61010-2-201
CAN/CSA C22.2 No.61010-1
Important Indicates cautions and limitations that must be followed during operation. CAN/CSA C22.2 No.61010-2-201
Wipe off any dirt on the units with a clean, dry cloth. Isolation transformer,
Remove any dust or dirt on connectors and other small parts with a cotton wool bud or similar noise filter, etc.
after temporarily disconnecting the connector.
• To reduce line noise, connect a 1:1 isolation transformer or noise filter.
Point
• Use twisted cables to reduce the influence of induced currents.
Specifications • When connecting the Power Supply Unit, be sure to connect it to a functional
earth terminal.
General specifications Use the following crimp terminals. The terminal screw is M3.5.
Shock resistance Acceleration 150 m/s2, application time 11 ms, applied three times in each Amount of Space to Leave Between Devices
direction: X, Y, and Z Ensure that there is a gap of at least 30 mm between the device, the inner wall, and other
Insulation resistance 50 M or more (500 V DC mega between all external terminals and case) devices.
Operating atmosphere An environment with as little dust and corrosive gas present as possible
Operating altitude 2,000 m or less
Overvoltage 30mm Space above and to left of device
Category Ⅱ Allow 30 mm of space for heat dissipation.
30mm
Pollution degree 2
Below
Weight Approx. 300g Allow 30 mm of space so that you can insert your finger
*1 Guaranteed range as a system. and remove the lock lever.
*2 Stipulated by the temperature at the bottom side of the unit, inside the control panel 30mm
REALTIME
Logic Controller
OUT AX2
CARD
V0+ V0+
MENU ENTER I0+ I0+
CH0 CH0
0- COM
COM NC
CARD SW V1+ V1+
I1+ I1+
CH1 CH1
PULL 1- COM
USB TEACHING
COM NC UNIT
V2+ V2+
I2+ I2+
CH2 CH2
2- COM
COM NC
Point Always make connections when the unit power is turned OFF.
-2-
1 Remove the cover on the left side of 2 Release the lock levers on the top and Dimensions
the CPU Unit. bottom of the Power Supply Unit.
• Place your finger on the depression, Unit: mm
and slide the lever toward the front of
2.5
8
the unit to release.
1.2
27.3
41.3
35.9
92.5
26.3
75
KV-
PU1
PO
WE KV-
KV-
R 750
0
750
0
CA
CA RD
4
RD
ME
ME
NU
NU
12.5 53 46.6 95
(with the cover open)
CA
PU RD
CA LL
RD EN
TE
EN R
TE
R
SW
SW
US
B
US
B
3 Connect the units by inserting the 4 Lock the lock levers on the top and
12.5
CPU Unit's lock levers into the lock bottom of the CPU Unit.
lever slots on the Power Supply Unit. • As in step 2, place your finger on the
• The units can be connected easily by depression, and slide the lever toward
holding them parallel and lining up the the back of the unit to lock it.
connectors. At this time, check whether there is a
gap between the units. A gap indicates
that the units are not properly
connected.
KV-
PU1
PO
WE
R
KV-
PU1
PU
LL
PO
WE
R
KV- KV-
750 750
0 0
PU
LL
CA CA
RD RD
ME ME
NU NU
CA CA
RD RD
EN EN
TE TE
R R
SW SW
US US
B B
LIN LIN
BA K BA K
T T
Eth Eth
erN erN
et/I NS et/I NS
P™ P™
5 Hook the upper clip on the back of the 6 Press the DIN rail until it clicks.
unit onto the upper groove on the DIN • This locks it into the lower black clip.
rail. Confirm that the black clip is pressed
in.
Top clip
Lower
DIN rail black clip
To remove the DIN rail, pull the lower black clip out.