Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Tooling Dimensions IT100 and IT400

IT100 (3") IT400 (4")


MAS SS LTCS MAS LTCS
A Space Between Fittings, Minimum 16 16 16 16 16
B Pipe Insertion Depth 120 120 120 140 140
C Length of Installed Lokring End, Nominal 87 87 87 100 100
D Pipe Spool Length Between Fittings, Minimum 250 278 256 288 286
E Distance to Cut Point for Forward Install 324 332 324 332 332
E Distance to Cut Point for Reverse Install* 148 185 148 172 172
F Minimum Spacing Between Parallel Pipes, Centre to Centre 180 178 178 204 204
Minimum Spacing between Parallel Pipes with Lokrings 189 191 189 216 212
G adjacent to each other, Centre to Centre
H Tool Height 264 293
J Tool Width 261 286
K Tool Depth 268 432
Weight of Tool 27 KG 43 KG
All Dimensions in mm. *Lokring Flanges and Tees can only be installed using the forward method