SERV1783 - 105 -

04/04

To discontinue the use of the continuous flow feature, the operator must actuate the auxiliary
proportional control or ON/OFF switches or depress and release the continuous flow switch.
The hydraulic lockout switch or opening the operator’s door will also disable the feature.

The continuous flow and interlock override switches are normally open, momentary
switch-to-ground switches. If the Auxiliary Hydraulic ECM detects the ground signal for either
switch for more than 30 seconds, the ECM determines that the switch is shorted to ground and
generates a fault.

In the event of a short to ground on the continuous flow switch circuit, the Auxiliary Hydraulic
ECM disables the continuous flow feature. Normal proportional tool control will still function.

In the event of a short to ground on the interlock override switch circuit, the Auxiliary
Hydraulic ECM disables the interlock override function. Normal proportional tool control and
continuous flow will still function.