Magnetic Particle Test Report


JOB DETAILS
Client Maritime Preservation Ltd Report Date 15th September, 2021
Attention Mr. Derek Williams Inspection Date 14th September, 2021
Project Vega Juno Expiry Date N/A
Job Location MS Vega Juno Ticket No. 92299
Job No. 04435 Report No. MPI04435-001
Job Description: To perform Post-Load-Test Magnetic Particle Inspection on:
Vega Juno Aft Crane SWL: 6.5TE

TEST DETAILS
Material Surface Condition Weld Process Type
Wet Dry
Carbon Steel Visible
☒ ☐
Clean SMAW
Wet Dry
Thickness N/A Fluorescent
☐ ☐
Procedure Acceptance Criteria Equipment Current Type
DC Yoke & Battery AC – 10 LBS ☐
WI-OPR-MPI-1A AWS D1.1
S/N TIS/MTE-09-005 DC – 40 LBS ☒
Field Adequacy and
Background Lighting Technique
Direction
Longitudinal Indirect Magnetic Particle Field
White Contrast Natural
Continuous Method Indicator

TEST RESULTS
Results Photograph
PASS ☒ FAIL ☐

At the time of inspection, no relevant indications were


found and all inspected welds were acceptable to
code.

Inspected By Reviewed By
VIVEK SUEDATH KERRON DHORAY
SNT-TC-1A LEVEL II MT INTEGRITY ENGINEER

Page | 1
Corner Pacific Ave. & Caribbean Dr., Point Lisas
Industrial Estate, Couva, Trinidad, West Indies
Ph: (868) 679-1573 / (868) 636-3201
Fax: (868) 636-6175 • www.tistt.com

Lifting Equipment Test Report


Client Maritime Preservation Ltd Job Location MS Vega Juno
Test Date 14th September, 2021 Ticket No. 92299
Work Order No. 04435 Report No. LDT04435-001
LIFTING EQUIPMENT DETAILS
Type / Description Vega Juno Aft Crane SWL: 6.5TE Identification No. N/A

MGW N/A TARE N/A Payload / SWL 6.5TE


TEST DETAILS
TO PERFORM PROOF LOAD TESTING ON VEGA JUNO AFT CRANE SWL:
Job Description
6.5TE
Type of Test Load Verification Load Test Proof Load Test

Reference/s BS 7121 Test Expiry Date N/A


N/A Load Cell/s WLS12T-TS
Certified Weight/s
S/N N/A S/N 40586
Rated Factor of Safety
1.25 Test Time 5 Minutes
(FoS)
Target Load 8.125 TE Measured Load 8.13 TE
We hereby certify that the aformentioned item
was load tested and the above particulars are
correct. The equipment was found to be safe to
operate after a subsequent thorough examination.

Inspection
Photo
Results

Fit for continued use Yes No

The indicated results of this test are only valid at the time of test. Post stress cracking, deterioration or
other defects may occur as a natural event or the result of usage. The owner or end user is responsible for
examining the (these) item (s) prior to each usage to determine suitability for every task.

Inspected By: ___________________ Reviewed By: _________________

Vivek Suedath Kerron Dhoray

Certified Lifting Inspector Integrity Engineer