TEST DETAILS
Material Surface Condition Weld Process Type
Wet Dry
Carbon Steel Visible
☒ ☐
Clean SMAW
Wet Dry
Thickness N/A Fluorescent
☐ ☐
Procedure Acceptance Criteria Equipment Current Type
DC Yoke & Battery AC – 10 LBS ☐
WI-OPR-MPI-1A AWS D1.1
S/N TIS/MTE-09-005 DC – 40 LBS ☒
Field Adequacy and
Background Lighting Technique
Direction
Longitudinal Indirect Magnetic Particle Field
White Contrast Natural
Continuous Method Indicator
TEST RESULTS
Results Photograph
PASS ☒ FAIL ☐
Inspected By Reviewed By
VIVEK SUEDATH KERRON DHORAY
SNT-TC-1A LEVEL II MT INTEGRITY ENGINEER
Page | 1
Corner Pacific Ave. & Caribbean Dr., Point Lisas
Industrial Estate, Couva, Trinidad, West Indies
Ph: (868) 679-1573 / (868) 636-3201
Fax: (868) 636-6175 • www.tistt.com
Inspection
Photo
Results
The indicated results of this test are only valid at the time of test. Post stress cracking, deterioration or
other defects may occur as a natural event or the result of usage. The owner or end user is responsible for
examining the (these) item (s) prior to each usage to determine suitability for every task.