RealTime Analyzer - Operation Manual
RealTime Analyzer - Operation Manual
RealTime
real-time analyzer
2017
RealTime
Operation manual
Copyright
© 2017 BALTECH
retrieval system, or translated into any language in any form by any means without
the prior written permission of Baltech.
Trademark
The BALTECH trademark is officially registered in Russia, CIS countries and in the
territory of the European Union. Other registered trademarks, logotypes and names
Responsibility
The information contained in this operation manual may be changed at the discretion
BALTECH GmbH doesn’t take any responsibility for any damages, direct or indirect,
that might be originated from use of the information contained in this operation
manual.
Technical support
If any assistance is required please address to BALTECH GmbH. Please specify the
software version number, which can be found out by calling the dialogue About.
What error messages appear? (if possible, copy the error message and send it by
e-mail).
Please prepare the problem report and send it to the following address:
info@baltech.biz.
The BALTECH Expert software update is provided for free. To receive the latest ver-
sion of the operation manual and installation file please visit our website
Main offices
Russia
Baltech LLC.
Tel./Fax: +7-812-335-00-85
e-mail: info@baltech.ru, web: www.baltech.ru
Kazakhstan
Germany
BALTECH GmbH
Content
1. Purpose 7
2. User interface 9
2.1. Program startup 9
2.2. Connecting devices 11
2.3. Acquisition parameters setting 12
2.4. General settings 15
2.5. The process of measuring vibrational waveform 16
2.6. Measurement results 17
2.7. Computed data 18
3. Examples of application of the program 20
3.1. Calibration of the measuring device 20
3.2. Coast down measurement 23
6 Content
RealTime
Operation manual
1. Purpose
- BCM
The program is a complementary tool supplied within the main software such as
BALTECH-Expert. To install the RealTime program during the main system software
installation select the Custom installation type and mark the «RealTime» component.
The program allows to set the measurement parameters and run a single process of
Purpose 7
RealTime
Operation manual
Received data are processed using the calculated mathematical functions and are
displayed for report in the form of a table with scalar values. A series of measurements
waveforms, auto-spectra and octave spectra, the following additional analysis tools
are avaliable to the user:
1) polar plot
2) orbit plot
4) correlation plot
5) cepstrum
8 Purpose
RealTime
Operation manual
The program has a standard structure and control tools. Both personal computer
keyboard and the «mouse» manipulator can be used when working with the program.
When working with the BALTECH VP-3470 system, before starting the program,
connect the measuring device using the USB interface cable and activate the
function «Control from PC» (see BALTECH VP 3470 - Vibration-balancer manual).
The main program window will open after program startup (Figure 2).
User interface 9
RealTime
Operation manual
1) Ribbon.
2) Results window.
3) Status bar.
The ribbon at the top of the program contains two tabs: «Measurements» and
«Devices», as well as a button for opening the dialog box «About wxRealTime». The
«Measurements» tab is used to collect data directly and to analyze it, the «Devices»
10 User interface
RealTime
Operation manual
The results window allows to switch the way of displaying of measured data by
Information about the status of the connected device is displayed in the status bar
at the bottom of the main window (Figure 2). To control the current device, select
the «Devices» tab on the ribbon.
User interface 11
RealTime
Operation manual
When the RealTime program is launched for the first time, all devices with the
drivers located in the same folder as the executable file will be added. The short
name of the active device is displayed on the left button of the panel, which is used
to switch devices. The «Del» button is used to delete devices. To add a new device
click the «Add» button and specify the appropriate dll-file with the device driver.
If you add the device driver that has already been listed, a copy of the device will
be added to the device list. At the same time the measurement settings of the
copies can be different and that allows to quickly switch the acquisition parameters
if necessary.
The acquisition parameters are set in a separate window called by the «Settings»
button.
device (see examples Figure 6, Figure 7). Various parameters could be set including
the active channels, the type of the signal, sampling frequency and the length
(number of samples).
When working with BALTECH VP-3470 the settings window has buttons for selecting
parameters and the «Info» button which is avaliable when the communication
parameters are set correctly and the device is in the «Control from PC» mode. When
12 User interface
RealTime
Operation manual
clicking on the «Info» button the status window displays information about the
connected system (the name of the system - internal name, serial number, internal
User interface 13
RealTime
Operation manual
14 User interface
RealTime
Operation manual
The button «Settings» on the «Measurements» tab opens the general settings
window in which you can set additional parameters for processing and displaying
the measured waveforms. These settings are not associated with specific equipment.
• Centre waveforms
• Window type
• Octave type
• Averaging mode
• Averagings nums
User interface 15
RealTime
Operation manual
The following parameters are used for polar graphs and orbits:
• Filtering
• Harmonic
• Q-factor
You can set the basic levels for displaying waveforms in dB in the general settings
window.
select the appropriate function from the group «Measurement» (Figure 10). When
Switching the vibration units buttons requires a new measurement for the update.
The unit selection buttons are located in the appropriate group (Figure 11).
16 User interface
RealTime
Operation manual
«Octave spectra» and «Results». You can analyse data by switching between the
tabs. In continuous measurement mode graphs and results are updated continuously
as each data set is collected. In this case, when an averaging is specified, the results
Buttons in the «Analysis» group are used to open additional graphical tools to
Measurements on two channels are required for Orbit and Polar plots.
Working with the graphs is described in detail in the manual for the main software.
Measurement results can be printed or saved for later analysis. To display the report
use the «Save» button. To open the saved data press the «Load» button.
User interface 17
RealTime
Operation manual
When importing from file, you can select data to be displayed (Figure 14).
This scalar parameters are displayed in the table on the «Results» tab.To add
new parameters, use the «Add» or «Insert» buttons. You can change the existing
parameter by clicking on the «Edit» button after selecting this parameter in the
Double-clicking on the cell with the parameter opens the window with trend for
this parameter on the corresponding input channel. If you want to build a trend for
measurements the obtained trend can be saved in a binary file. To open a previously
18 User interface
RealTime
Operation manual
As the extension of the binary data files and trend files is the same, it is recommended
to save the measurement results and the built trends in different folders on the
disk. The attempts to load the binary file with the trend as a data file with the
results, and vice versa, will result in the «Invalid data format» error.
User interface 19
RealTime
Operation manual
You can create a set of parameters for recording the measured values when testing
the measuring device using a shaker.
The example of setting the computed data for the registration of RMS vibration
The example of measurement results in the form of waveforms, spectra and results
for a pure sinusoid is shown in the figures below (Figure 16 - Figure 18).
The figures show the trends of the following parameters, calculated from the data
When opening the stored trend data, you can select one of the parameters as an