Professional Documents
Culture Documents
Footing Calculations
Footing Calculations
Footing Calculations
Definitions:
1. A = Plan area of footing base in sqmm
2. Ast (min) = Area of longitudinal reinforcement as per code cl.
7.12.2.1 in sqmm
3. Ast Prv = Area of tensile reinforcement provided in sqmm
4. Ast Rqd = Area of longitudinal reinforcement from bearing
moment and minimum % steel provided by user and as
per code cl 7.12.2.1 in sqmm
5. Av = Area of shear reinforcement required in sqmm
6. AvPrv = Area of shear reinforcement provided in sqmm
7. A1 = Bearing area of footing at slope of 1:2 in sqmm
8. A2 = C/s Area of column in sqmm
9. B = Width of footing base in mm
10. Beff = Effective width of footing in mm
11. Boff = Footing offset along B in mm
12. BoffB = Footing offset along B above column in plan
13. BoffT = Footing offset along B below column in plan
14. B1 = Width of sloped footing at top in mm
15. ColOff = Column offset in sloped footing in mm
16. Cx = Width of column in mm
17. Cy = Length of Column in mm
18. D = Depth of footing in mm
19. d = Effective Depth of footing in mm
20. Dfd = Depth of founding layer in m
21. Dw = Ground water level in m
22. Ec = Modulus of elasticity of concrete in N/sqmm
23. Es = Modulus of elasticity of steel in N/sqmm
24. Foss = Safety factor against sliding
25. Fosu = Safety factor against uplift
26. Fst = Stress in steel in N/sqmm
27. F'c = Characteristic strength of concrete in N/sqmm
28. Icr = Moment of Inertia of concrete crack section N/sqmm
29. L = Length of footing base in mm
30. Leff = Effective length of footing in mm
31. Loff = Footing offset along L in mm
32. LoffL = Footing offset along L on left side of column
33. LoffR = Footing offset along L on right side of column
34. L1 = Length of sloped footing at top in mm
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 2 of 30
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 3 of 30
Code References:
ACI 318M - 2014
Sr.No. Item Clause / Table
1. Ptmax : 7.3.3.1, 8.3.3.1, 9.3.3.1
2. Ptmin : 7.6.1.1 & 8.6.1.1/7.7.2.3
3. Vc : 22.6.5
4. Av : 22.5.10.5 & 22.6.7
5. Max Stirrup Spacing : 9.7.6.2 & 10.7.6.5
6. Vs : 22.5.1.2
7. fs,perm : 10.6.4
8. fc,perm : 10.2.7.1
9. Wcr : Eq 4.2(a)
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 4 of 30
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 5 of 30
My/Zy = 0 kN/sqm
Deff = 317 mm
Beff = 1850 mm
SPu = 73.15 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 38.06 kNm
Ast Rqd = 2034 sqmm
Ast (min) = 2034 sqmm
Ast Prv = 14 - #16 @ 150
= 2815 sqmm
Distributed Across Total Width
Deff = 301 mm
Leff = 1850 mm
SPu = 73.15 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 38.06 kNm
Ast Rqd = 2034 sqmm
Ast (min) = 2034 sqmm
Ast Prv = 14 - #16 @ 150
= 2815 sqmm
Distributed Across Total Length
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 6 of 30
= 317 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 250.35 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.15 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 317 mm
Beff = 1850 mm
SPu = 73.15 kN/sqm
Vu = SPu X (Loff - d) X B
= 58.59 kN
φVc = 380.65 kN
Vu < φVc
= 301 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 250.35 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.15 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 301 mm
Leff = 1850 mm
SPu = 73.15 kN/sqm
Vu = SPu X (Boff - d) X L
= 60.76 kN
φVc = 363.25 kN
Vu < φVc
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 7 of 30
Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 73.15 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 218.58 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 8 of 30
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 9 of 30
Combination
Critical Load Combination = [3] : 1.2 (LOAD 9: DL)
+0.5 (LOAD 10: LL)
Pcomb = 108.61 kN
P = Pcomb + Effective Self Weight x 1.2
P = 128.89 kN
Mx = 0 kNm
My = 0 kNm
P/A = 76.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 76.27 kN/sqm
> 0
Deff = 317 mm
Beff = 1300 mm
SPu = 73.67 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 10.8 kNm
Ast Rqd = 1430 sqmm
Ast (min) = 1430 sqmm
Ast Prv = 10 - #16 @ 150
= 2011 sqmm
Distributed Across Total Width
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 10 of 30
Muy = 0 kNm
P/A = 73.67 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 301 mm
Leff = 1300 mm
SPu = 73.67 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 10.8 kNm
Ast Rqd = 1430 sqmm
Ast (min) = 1430 sqmm
Ast Prv = 10 - #16 @ 150
= 2011 sqmm
Distributed Across Total Length
Deff = 317 mm
Beff = 1300 mm
SPu = 73.67 kN/sqm
Vu = SPu X (Loff - d) X B
= 15.13 kN
φVc = 276.48 kN
Vu < φVc
= 301 mm
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 11 of 30
Deff = 301 mm
Leff = 1300 mm
SPu = 73.67 kN/sqm
Vu = SPu X (Boff - d) X L
= 16.66 kN
φVc = 262.53 kN
Vu < φVc
Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 73.67 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 92.5 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 12 of 30
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 13 of 30
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 14 of 30
My/Zy = 0 kN/sqm
Deff = 317 mm
Beff = 2300 mm
SPu = 73.47 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 80.32 kNm
Ast Rqd = 2529 sqmm
Ast (min) = 2529 sqmm
Ast Prv = 17 - #16 @ 150
= 3418 sqmm
Distributed Across Total Width
Deff = 301 mm
Leff = 2300 mm
SPu = 73.47 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 80.32 kNm
Ast Rqd = 2529 sqmm
Ast (min) = 2529 sqmm
Ast Prv = 17 - #16 @ 150
= 3418 sqmm
Distributed Across Total Length
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 15 of 30
= 317 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 388.68 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.47 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 317 mm
Beff = 2300 mm
SPu = 73.47 kN/sqm
Vu = SPu X (Loff - d) X B
= 111.20 kN
φVc = 472.20 kN
Vu < φVc
= 301 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 388.68 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.47 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 301 mm
Leff = 2300 mm
SPu = 73.47 kN/sqm
Vu = SPu X (Boff - d) X L
= 113.90 kN
φVc = 450.57 kN
Vu < φVc
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 16 of 30
Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 73.47 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 356.77 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 17 of 30
Analysis No : 12
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 18 of 30
Deff = 317 mm
Beff = 1750 mm
SPu = 74.29 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 31.85 kNm
Ast Rqd = 1924 sqmm
Ast (min) = 1924 sqmm
Ast Prv = 13 - #16 @ 150
= 2614 sqmm
Distributed Across Total Width
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 19 of 30
Deff = 301 mm
Leff = 1750 mm
SPu = 74.29 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 31.85 kNm
Ast Rqd = 1924 sqmm
Ast (min) = 1924 sqmm
Ast Prv = 13 - #16 @ 150
= 2614 sqmm
Distributed Across Total Length
Deff = 317 mm
Beff = 1750 mm
SPu = 74.29 kN/sqm
Vu = SPu X (Loff - d) X B
= 49.79 kN
φVc = 359.45 kN
Vu < φVc
= 301 mm
Critical Analysis Load = 201
Combination
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 20 of 30
Deff = 301 mm
Leff = 1750 mm
SPu = 74.29 kN/sqm
Vu = SPu X (Boff - d) X L
= 51.87 kN
φVc = 342.99 kN
Vu < φVc
Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 74.29 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 195.25 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 21 of 30
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 227.51 kN
A2 = 0.12 sqm
A1 = 3.8 sqm
Base Area = 3.06 sqm
A1 > Base Area
Thus, A1 = 3.06
Modification Factor = SquareRoot(A1/A2) < =
2
SquareRoot(A1/A2) = 5.0498
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column
Area
= 3248.7 kN
Φ1Pnb > Pu, Hence Safe.
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 22 of 30
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 23 of 30
Deff = 317 mm
Beff = 2500 mm
SPu = 74.76 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 108 kNm
Ast Rqd = 2749 sqmm
Ast (min) = 2749 sqmm
Ast Prv = 18 - #16 @ 150
= 3619 sqmm
Distributed Across Total Width
Deff = 301 mm
Leff = 2500 mm
SPu = 74.76 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 108 kNm
Ast Rqd = 2749 sqmm
Ast (min) = 2749 sqmm
Ast Prv = 18 - #16 @ 150
= 3619 sqmm
Distributed Across Total Length
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 24 of 30
Deff = 317 mm
Beff = 2500 mm
SPu = 74.76 kN/sqm
Vu = SPu X (Loff - d) X B
= 141.67 kN
φVc = 512.04 kN
Vu < φVc
= 301 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 467.26 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.76 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 301 mm
Leff = 2500 mm
SPu = 74.76 kN/sqm
Vu = SPu X (Boff - d) X L
= 144.66 kN
φVc = 488.52 kN
Vu < φVc
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 25 of 30
Pu = 467.26 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.76 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 74.76 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 434.79 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 26 of 30
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 27 of 30
Pcomb = 242.62 kN
P = Pcomb + Effective Self Weight x 1.2
P = 288.25 kN
Mx = 0 kNm
My = 0 kNm
P/A = 75.81 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 75.81 kN/sqm
> 0
Deff = 317 mm
Beff = 1950 mm
SPu = 73 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 45.55 kNm
Ast Rqd = 2144 sqmm
Ast (min) = 2144 sqmm
Ast Prv = 14 - #16 @ 150
= 2815 sqmm
Distributed Across Total Width
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 28 of 30
My/Zy = 0 kN/sqm
Deff = 301 mm
Leff = 1950 mm
SPu = 73 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 45.55 kNm
Ast Rqd = 2144 sqmm
Ast (min) = 2144 sqmm
Ast Prv = 14 - #16 @ 150
= 2815 sqmm
Distributed Across Total Length
Deff = 317 mm
Beff = 1950 mm
SPu = 73 kN/sqm
Vu = SPu X (Loff - d) X B
= 68.76 kN
φVc = 399.29 kN
Vu < φVc
= 301 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 277.59 kN
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 29 of 30
Mux = 0 kNm
Muy = 0 kNm
P/A = 73 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Deff = 301 mm
Leff = 1950 mm
SPu = 73 kN/sqm
Vu = SPu X (Boff - d) X L
= 71.03 kN
φVc = 380.94 kN
Vu < φVc
Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 73 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 245.88 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 30 of 30
Pu = 277.59 kN
A2 = 0.12 sqm
A1 = 3.8 sqm
Base Area = 3.8 sqm
A1 > Base Area
Thus, A1 = 3.8
Modification Factor = SquareRoot(A1/A2) < =
2
SquareRoot(A1/A2) = 5.6273
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column
Area
= 3248.7 kN
Φ1Pnb > Pu, Hence Safe.
file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023