Footing Calculations

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 30

Footing Design: Design Calculation Page 1 of 30

FOOTING DESIGN CALCULATIONS


Project Name : TWO-STOREY RESIDENTIAL BUILDING
Client Name : MRS. AGUILLON
Engineer Name : ENGR. G. HANDAYAN
Design File : D:\projects\handayan structural\Structure1-Footing-1.rcdx
Analysis File : D:\projects\handayan structural\Structure1.STD
Analysis Last Modified : 20/01/2023 12:46:21 pm

Definitions:
1. A = Plan area of footing base in sqmm
2. Ast (min) = Area of longitudinal reinforcement as per code cl.
7.12.2.1 in sqmm
3. Ast Prv = Area of tensile reinforcement provided in sqmm
4. Ast Rqd = Area of longitudinal reinforcement from bearing
moment and minimum % steel provided by user and as
per code cl 7.12.2.1 in sqmm
5. Av = Area of shear reinforcement required in sqmm
6. AvPrv = Area of shear reinforcement provided in sqmm
7. A1 = Bearing area of footing at slope of 1:2 in sqmm
8. A2 = C/s Area of column in sqmm
9. B = Width of footing base in mm
10. Beff = Effective width of footing in mm
11. Boff = Footing offset along B in mm
12. BoffB = Footing offset along B above column in plan
13. BoffT = Footing offset along B below column in plan
14. B1 = Width of sloped footing at top in mm
15. ColOff = Column offset in sloped footing in mm
16. Cx = Width of column in mm
17. Cy = Length of Column in mm
18. D = Depth of footing in mm
19. d = Effective Depth of footing in mm
20. Dfd = Depth of founding layer in m
21. Dw = Ground water level in m
22. Ec = Modulus of elasticity of concrete in N/sqmm
23. Es = Modulus of elasticity of steel in N/sqmm
24. Foss = Safety factor against sliding
25. Fosu = Safety factor against uplift
26. Fst = Stress in steel in N/sqmm
27. F'c = Characteristic strength of concrete in N/sqmm
28. Icr = Moment of Inertia of concrete crack section N/sqmm
29. L = Length of footing base in mm
30. Leff = Effective length of footing in mm
31. Loff = Footing offset along L in mm
32. LoffL = Footing offset along L on left side of column
33. LoffR = Footing offset along L on right side of column
34. L1 = Length of sloped footing at top in mm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 2 of 30

35. Mcr = Cracking Moment


36. Mx = Bending Moment along column D in kN-m
37. Mex = Eccentricity moment along column D
38. Mxx = Total Bending Moment along column D (Mx + Mex)
39. My = Bending Moment along column B in kN-m
40. Mey = Eccentricity moment along column B
41. Myy = Total Bending Moment along column B (My + Mey)
42. Muy = Factored moment along column B in kN-m
43. Mux = Factored moment along column D in kN-m
44. Netdown = Net downward load in kN
45. OB = Maximum permissible offset on bottom side of column
46. OL = Maximum permissible offset on left side of column
47. OR = Maximum permissible offset on right side of column
48. OT = Maximum permissible offset on top side of column
49. P = Axial load for footing sizing in kN
50. Pcr(axial) = Design pressure at the critical section kN/sqm
51. P1 = Soil pressure at corner 1 in kN/sqm
52. P2 = Soil pressure at corner 2 kN/sqm
53. P3 = Soil pressure at corner 3 kN/sqm
54. P4 = Soil pressure at corner 4 kN/sqm
55. q = Surcharge Load in kN/sqm
56. sp = Spacing Between bars at outer most layer in mm
57. SPu = Upward Soil Pressure in kN/sqm
58. SPuL = Upward Soil Pressure from left
59. SPuR = Upward Soil Pressure from right
60. SPuB = Upward Soil Pressure from bottom
61. SPuT = Upward Soil Pressure from top
62. Temp1 = Peak Hydration temperature in Degree
63. Temp2 = Seasonal Temperature Variations in Degree
64. Vs Capacity = Shear strength capacity of provided shear
reinforcement kN
65. Vs = Nominal shear strength provided by shear
reinforcement, in KN
66. Vc = Nominal shear strength provided by concrete in kN
67. Vu = Design shear force in kN
68. Vus = Strength of shear reinforcement in kN
69. Vx = Shear along major axis in kN
70. Vy = Shear along minor axis in kN
71. Waterpr = Upward water pressure in kN/sqm
72. Waterup = Upward force due to water in kN/sqm
73. WFoot = Add. Wt. due to difference in concrete and soil density
in kN
74. WFootc = Weight of footing and column with concrete density in
kN
75. WSoil = Weight of soil covering footing area in kN
76. y = Neutral axis depth.
77. Zx = Section modulus of footing base along L in mm3

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 3 of 30

78. Zy = Section modulus of footing base along B in mm3


79. Φ = Strength reduction factor in shear
80. Φ1 = Strength reduction factor in concrete bearing
81. Φ1Pnb = Bearing strength of column in kN

Code References:
ACI 318M - 2014
Sr.No. Item Clause / Table
1. Ptmax : 7.3.3.1, 8.3.3.1, 9.3.3.1
2. Ptmin : 7.6.1.1 & 8.6.1.1/7.7.2.3
3. Vc : 22.6.5
4. Av : 22.5.10.5 & 22.6.7
5. Max Stirrup Spacing : 9.7.6.2 & 10.7.6.5
6. Vs : 22.5.1.2
7. fs,perm : 10.6.4
8. fc,perm : 10.2.7.1
9. Wcr : Eq 4.2(a)

Design Code : ACI 318M - 2014


Footing No : FC1
Column No : C1 ( 350mm X 350mm)
Analysis No : 8

Concrete Grade : C24


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 4M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 90 kN/sqm
Permissible SBC Increase for EQ = 33 %
Permissible SBC Increase for = 0 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of = 0 %
contact

Design cross section by : Average pressure


Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 1850mm X 1850mm X 400mm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 4 of 30

Effective Self Weight = 34.23 KN

Offset Along L (Loff) = 750 mm


Offset Along B (Boff) = 750 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 201
Combination
Critical Load Combination = [1] : 1.4 (LOAD 9: DL)
Pcomb = 250.35 kN
P = Pcomb + Effective Self Weight x 1.4
P = 298.26 kN
Mx = 0 kNm
My = 0 kNm
P/A = 87.15 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Maximum Soil Pressure = 87.15 kN/sqm
Allowable Soil Pressure = 1x90 kN/sqm
= 90 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 203
Combination
Critical Load Combination = [3] : 1.2 (LOAD 9: DL)
+0.5 (LOAD 10: LL)
Pcomb = 218.21 kN
P = Pcomb + Effective Self Weight x 1.2
P = 259.28 kN
Mx = 0 kNm
My = 0 kNm
P/A = 75.76 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 75.76 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 250.35 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.15 kN/sqm
Mx/Zx = 0 kN/sqm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 5 of 30

My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 1850 mm
SPu = 73.15 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 38.06 kNm
Ast Rqd = 2034 sqmm
Ast (min) = 2034 sqmm
Ast Prv = 14 - #16 @ 150
= 2815 sqmm
Distributed Across Total Width

Top Steel Along L:


Ast Prv = 14 - #16 @ 150 c/c
= 2815 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 250.35 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.15 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 1850 mm
SPu = 73.15 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 38.06 kNm
Ast Rqd = 2034 sqmm
Ast (min) = 2034 sqmm
Ast Prv = 14 - #16 @ 150
= 2815 sqmm
Distributed Across Total Length

Top Steel Along B:


Ast Prv = 14 - #16 @ 150 c/c
= 2815 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 6 of 30

= 317 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 250.35 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.15 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 1850 mm
SPu = 73.15 kN/sqm
Vu = SPu X (Loff - d) X B
= 58.59 kN
φVc = 380.65 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 301 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 250.35 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.15 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 1850 mm
SPu = 73.15 kN/sqm
Vu = SPu X (Boff - d) X L
= 60.76 kN
φVc = 363.25 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 154 mm

Critical Analysis Load = 201


Combination

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 7 of 30

Critical Load Combination = [4] : 1.4 (LOAD 9: DL)


Pu = 250.35 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.15 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 73.15 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 218.58 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 250.35 kN
A2 = 0.12 sqm
A1 = 3.8 sqm
Base Area = 3.42 sqm
A1 > Base Area
Thus, A1 = 3.42
Modification Factor = SquareRoot(A1/A2)  < =
2
SquareRoot(A1/A2) = 5.3385
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column
Area
= 3248.7 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2014


Footing No : FC2

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 8 of 30

Column No : C2 ( 350mm X 350mm)


Analysis No : 9

Concrete Grade : C24


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 4M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 90 kN/sqm
Permissible SBC Increase for EQ = 33 %
Permissible SBC Increase for = 0 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of = 0 %
contact

Design cross section by : Average pressure


Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 1300mm X 1300mm X 400mm
Effective Self Weight = 16.90 KN

Offset Along L (Loff) = 475 mm


Offset Along B (Boff) = 475 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 201
Combination
Critical Load Combination = [1] : 1.4 (LOAD 9: DL)
Pcomb = 124.49 kN
P = Pcomb + Effective Self Weight x 1.4
P = 148.15 kN
Mx = 0 kNm
My = 0 kNm
P/A = 87.67 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Maximum Soil Pressure = 87.67 kN/sqm
Allowable Soil Pressure = 1x90 kN/sqm
= 90 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 203

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 9 of 30

Combination
Critical Load Combination = [3] : 1.2 (LOAD 9: DL)
+0.5 (LOAD 10: LL)
Pcomb = 108.61 kN
P = Pcomb + Effective Self Weight x 1.2
P = 128.89 kN
Mx = 0 kNm
My = 0 kNm
P/A = 76.27 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 76.27 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 124.49 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.67 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 1300 mm
SPu = 73.67 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 10.8 kNm
Ast Rqd = 1430 sqmm
Ast (min) = 1430 sqmm
Ast Prv = 10 - #16 @ 150
= 2011 sqmm
Distributed Across Total Width

Top Steel Along L:


Ast Prv = 10 - #16 @ 150 c/c
= 2011 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 124.49 kN
Mux = 0 kNm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 10 of 30

Muy = 0 kNm
P/A = 73.67 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 1300 mm
SPu = 73.67 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 10.8 kNm
Ast Rqd = 1430 sqmm
Ast (min) = 1430 sqmm
Ast Prv = 10 - #16 @ 150
= 2011 sqmm
Distributed Across Total Length

Top Steel Along B:


Ast Prv = 10 - #16 @ 150 c/c
= 2011 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 317 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 124.49 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.67 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 1300 mm
SPu = 73.67 kN/sqm
Vu = SPu X (Loff - d) X B
= 15.13 kN
φVc = 276.48 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 301 mm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 11 of 30

Critical Analysis Load = 201


Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 124.49 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.67 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 1300 mm
SPu = 73.67 kN/sqm
Vu = SPu X (Boff - d) X L
= 16.66 kN
φVc = 262.53 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 154 mm

Critical Analysis Load = 201


Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 124.49 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.67 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 73.67 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 92.5 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 12 of 30

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 124.49 kN
A2 = 0.12 sqm
A1 = 3.8 sqm
Base Area = 1.69 sqm
A1 > Base Area
Thus, A1 = 1.69
Modification Factor = SquareRoot(A1/A2)  < =
2
SquareRoot(A1/A2) = 3.7528
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column
Area
= 3248.7 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2014


Footing No : FC3
Column No : C3 ( 350mm X 350mm)
Analysis No : 10

Concrete Grade : C24


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 4M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 90 kN/sqm
Permissible SBC Increase for EQ = 33 %
Permissible SBC Increase for = 0 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of = 0 %
contact

Design cross section by : Average pressure


Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 2300mm X 2300mm X 400mm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 13 of 30

Effective Self Weight = 52.90 KN

Offset Along L (Loff) = 975 mm


Offset Along B (Boff) = 975 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 201
Combination
Critical Load Combination = [1] : 1.4 (LOAD 9: DL)
Pcomb = 388.68 kN
P = Pcomb + Effective Self Weight x 1.4
P = 462.74 kN
Mx = 0 kNm
My = 0 kNm
P/A = 87.47 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Maximum Soil Pressure = 87.47 kN/sqm
Allowable Soil Pressure = 1x90 kN/sqm
= 90 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 203
Combination
Critical Load Combination = [3] : 1.2 (LOAD 9: DL)
+0.5 (LOAD 10: LL)
Pcomb = 340.27 kN
P = Pcomb + Effective Self Weight x 1.2
P = 403.75 kN
Mx = 0 kNm
My = 0 kNm
P/A = 76.32 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 76.32 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 388.68 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.47 kN/sqm
Mx/Zx = 0 kN/sqm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 14 of 30

My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 2300 mm
SPu = 73.47 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 80.32 kNm
Ast Rqd = 2529 sqmm
Ast (min) = 2529 sqmm
Ast Prv = 17 - #16 @ 150
= 3418 sqmm
Distributed Across Total Width

Top Steel Along L:


Ast Prv = 17 - #16 @ 150 c/c
= 3418 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 388.68 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.47 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 2300 mm
SPu = 73.47 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 80.32 kNm
Ast Rqd = 2529 sqmm
Ast (min) = 2529 sqmm
Ast Prv = 17 - #16 @ 150
= 3418 sqmm
Distributed Across Total Length

Top Steel Along B:


Ast Prv = 17 - #16 @ 150 c/c
= 3418 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 15 of 30

= 317 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 388.68 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.47 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 2300 mm
SPu = 73.47 kN/sqm
Vu = SPu X (Loff - d) X B
= 111.20 kN
φVc = 472.20 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 301 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 388.68 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.47 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 2300 mm
SPu = 73.47 kN/sqm
Vu = SPu X (Boff - d) X L
= 113.90 kN
φVc = 450.57 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 154 mm

Critical Analysis Load = 201


Combination

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 16 of 30

Critical Load Combination = [4] : 1.4 (LOAD 9: DL)


Pu = 388.68 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73.47 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 73.47 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 356.77 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 388.68 kN
A2 = 0.12 sqm
A1 = 3.8 sqm
Base Area = 5.29 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2)  < =
2
SquareRoot(A1/A2) = 5.6273
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column
Area
= 3248.7 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2014


Footing No : FC4
Column No : C4 ( 350mm X 350mm)

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 17 of 30

Analysis No : 12

Concrete Grade : C24


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 4M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 90 kN/sqm
Permissible SBC Increase for EQ = 33 %
Permissible SBC Increase for = 0 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of = 0 %
contact

Design cross section by : Average pressure


Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 1750mm X 1750mm X 400mm
Effective Self Weight = 30.63 KN

Offset Along L (Loff) = 700 mm


Offset Along B (Boff) = 700 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 201
Combination
Critical Load Combination = [1] : 1.4 (LOAD 9: DL)
Pcomb = 227.51 kN
P = Pcomb + Effective Self Weight x 1.4
P = 270.39 kN
Mx = 0 kNm
My = 0 kNm
P/A = 88.29 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Maximum Soil Pressure = 88.29 kN/sqm
Allowable Soil Pressure = 1x90 kN/sqm
= 90 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 203
Combination

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 18 of 30

Critical Load Combination = [3] : 1.2 (LOAD 9: DL)


+0.5 (LOAD 10: LL)
Pcomb = 199.51 kN
P = Pcomb + Effective Self Weight x 1.2
P = 236.26 kN
Mx = 0 kNm
My = 0 kNm
P/A = 77.15 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 77.15 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 227.51 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.29 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 1750 mm
SPu = 74.29 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 31.85 kNm
Ast Rqd = 1924 sqmm
Ast (min) = 1924 sqmm
Ast Prv = 13 - #16 @ 150
= 2614 sqmm
Distributed Across Total Width

Top Steel Along L:


Ast Prv = 13 - #16 @ 150 c/c
= 2614 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 227.51 kN
Mux = 0 kNm
Muy = 0 kNm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 19 of 30

P/A = 74.29 kN/sqm


Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 1750 mm
SPu = 74.29 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 31.85 kNm
Ast Rqd = 1924 sqmm
Ast (min) = 1924 sqmm
Ast Prv = 13 - #16 @ 150
= 2614 sqmm
Distributed Across Total Length

Top Steel Along B:


Ast Prv = 13 - #16 @ 150 c/c
= 2614 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 317 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 227.51 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.29 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 1750 mm
SPu = 74.29 kN/sqm
Vu = SPu X (Loff - d) X B
= 49.79 kN
φVc = 359.45 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 301 mm
Critical Analysis Load = 201
Combination

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 20 of 30

Critical Load Combination = [4] : 1.4 (LOAD 9: DL)


Pu = 227.51 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.29 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 1750 mm
SPu = 74.29 kN/sqm
Vu = SPu X (Boff - d) X L
= 51.87 kN
φVc = 342.99 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 154 mm

Critical Analysis Load = 201


Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 227.51 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.29 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 74.29 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 195.25 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 201

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 21 of 30

Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 227.51 kN
A2 = 0.12 sqm
A1 = 3.8 sqm
Base Area = 3.06 sqm
A1 > Base Area
Thus, A1 = 3.06
Modification Factor = SquareRoot(A1/A2)  < =
2
SquareRoot(A1/A2) = 5.0498
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column
Area
= 3248.7 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2014


Footing No : FC5
Column No : C5 ( 350mm X 350mm)
Analysis No : 11

Concrete Grade : C24


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 4M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 90 kN/sqm
Permissible SBC Increase for EQ = 33 %
Permissible SBC Increase for = 0 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of = 0 %
contact

Design cross section by : Average pressure


Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 2500mm X 2500mm X 400mm
Effective Self Weight = 62.50 KN

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 22 of 30

Offset Along L (Loff) = 1075 mm


Offset Along B (Boff) = 1075 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 201
Combination
Critical Load Combination = [1] : 1.4 (LOAD 9: DL)
Pcomb = 467.26 kN
P = Pcomb + Effective Self Weight x 1.4
P = 554.76 kN
Mx = 0 kNm
My = 0 kNm
P/A = 88.76 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Maximum Soil Pressure = 88.76 kN/sqm
Allowable Soil Pressure = 1x90 kN/sqm
= 90 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 203
Combination
Critical Load Combination = [3] : 1.2 (LOAD 9: DL)
+0.5 (LOAD 10: LL)
Pcomb = 412.30 kN
P = Pcomb + Effective Self Weight x 1.2
P = 487.3 kN
Mx = 0 kNm
My = 0 kNm
P/A = 77.97 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 77.97 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 467.26 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.76 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 23 of 30

Deff = 317 mm
Beff = 2500 mm
SPu = 74.76 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 108 kNm
Ast Rqd = 2749 sqmm
Ast (min) = 2749 sqmm
Ast Prv = 18 - #16 @ 150
= 3619 sqmm
Distributed Across Total Width

Top Steel Along L:


Ast Prv = 18 - #16 @ 150 c/c
= 3619 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 467.26 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.76 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 2500 mm
SPu = 74.76 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 108 kNm
Ast Rqd = 2749 sqmm
Ast (min) = 2749 sqmm
Ast Prv = 18 - #16 @ 150
= 3619 sqmm
Distributed Across Total Length

Top Steel Along B:


Ast Prv = 18 - #16 @ 150 c/c
= 3619 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 317 mm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 24 of 30

Critical Analysis Load = 201


Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 467.26 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.76 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 2500 mm
SPu = 74.76 kN/sqm
Vu = SPu X (Loff - d) X B
= 141.67 kN
φVc = 512.04 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 301 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 467.26 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.76 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 2500 mm
SPu = 74.76 kN/sqm
Vu = SPu X (Boff - d) X L
= 144.66 kN
φVc = 488.52 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 154 mm

Critical Analysis Load = 201


Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 25 of 30

Pu = 467.26 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 74.76 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 74.76 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 434.79 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 467.26 kN
A2 = 0.12 sqm
A1 = 3.8 sqm
Base Area = 6.25 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2)  < =
2
SquareRoot(A1/A2) = 5.6273
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column
Area
= 3248.7 kN
Φ1Pnb > Pu, Hence Safe.

Design Code : ACI 318M - 2014


Footing No : FC6
Column No : C6 ( 350mm X 350mm)
Analysis No : 13

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 26 of 30

Concrete Grade : C24


Steel Grade : Fy275
Clear Cover : 75 mm
Dfd : 4M
Dw : 1M

Density of Soil = 18 KN/cuM


Soil Bearing Capacity = 90 kN/sqm
Permissible SBC Increase for EQ = 33 %
Permissible SBC Increase for = 0 %
Wind
Live Load Reduction = 0 %
Permissible area of loss of = 0 %
contact

Design cross section by : Average pressure


Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 1950mm X 1950mm X 400mm
Effective Self Weight = 38.03 KN

Offset Along L (Loff) = 800 mm


Offset Along B (Boff) = 800 mm

Check For Maximum Soil Pressure:


Critical Analysis Load = 201
Combination
Critical Load Combination = [1] : 1.4 (LOAD 9: DL)
Pcomb = 277.59 kN
P = Pcomb + Effective Self Weight x 1.4
P = 330.82 kN
Mx = 0 kNm
My = 0 kNm
P/A = 87 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Maximum Soil Pressure = 87 kN/sqm
Allowable Soil Pressure = 1x90 kN/sqm
= 90 kN/sqm

Check For Minimum Soil Pressure:


Critical Analysis Load = 203
Combination
Critical Load Combination = [3] : 1.2 (LOAD 9: DL)
+0.5 (LOAD 10: LL)

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 27 of 30

Pcomb = 242.62 kN
P = Pcomb + Effective Self Weight x 1.2
P = 288.25 kN
Mx = 0 kNm
My = 0 kNm
P/A = 75.81 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm
Minimum Soil Pressure = 75.81 kN/sqm
> 0

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 277.59 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 1950 mm
SPu = 73 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 45.55 kNm
Ast Rqd = 2144 sqmm
Ast (min) = 2144 sqmm
Ast Prv = 14 - #16 @ 150
= 2815 sqmm
Distributed Across Total Width

Top Steel Along L:


Ast Prv = 14 - #16 @ 150 c/c
= 2815 sqmm

Bottom Reinforcement Along B:


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 277.59 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73 kN/sqm
Mx/Zx = 0 kN/sqm

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 28 of 30

My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 1950 mm
SPu = 73 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 45.55 kNm
Ast Rqd = 2144 sqmm
Ast (min) = 2144 sqmm
Ast Prv = 14 - #16 @ 150
= 2815 sqmm
Distributed Across Total Length

Top Steel Along B:


Ast Prv = 14 - #16 @ 150 c/c
= 2815 sqmm
Design For Shear:
One Way Shear Along L:
Critical Section @ d from Column Face
= 317 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 277.59 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 317 mm
Beff = 1950 mm
SPu = 73 kN/sqm
Vu = SPu X (Loff - d) X B
= 68.76 kN
φVc = 399.29 kN
Vu < φVc

One Way Shear Along B:


Critical Section @ d from Column Face

= 301 mm
Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 277.59 kN

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 29 of 30

Mux = 0 kNm
Muy = 0 kNm
P/A = 73 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 301 mm
Leff = 1950 mm
SPu = 73 kN/sqm
Vu = SPu X (Boff - d) X L
= 71.03 kN
φVc = 380.94 kN
Vu < φVc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 154 mm

Critical Analysis Load = 201


Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)
Pu = 277.59 kN
Mux = 0 kNm
Muy = 0 kNm
P/A = 73 kN/sqm
Mx/Zx = 0 kN/sqm
My/Zy = 0 kN/sqm

Deff = 309 mm
Leff = 659 mm
Beff = 659 mm
Punching Perimeter = 2636 mm
Punching Area = 814524 sqmm
SPu = Average Pressure
= 73 kN/sqm
Vu = { SPu [ (L x B)- (Leff x
Beff)]}
= 245.88 kN
φVn = 1496.376 kN
φVc = 987.608 kN
No Shear Reinforcement
Vu < φVc
Required

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load = 201
Combination
Critical Load Combination = [4] : 1.4 (LOAD 9: DL)

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023
Footing Design: Design Calculation Page 30 of 30

Pu = 277.59 kN
A2 = 0.12 sqm
A1 = 3.8 sqm
Base Area = 3.8 sqm
A1 > Base Area
Thus, A1 = 3.8
Modification Factor = SquareRoot(A1/A2)  < =
2
SquareRoot(A1/A2) = 5.6273
Thus, Modification Factor = 2
Φ1 = 0.65
Φ1Pnb = Φ1 X 0.85 X Fck X Modication Factor X Column
Area
= 3248.7 kN
Φ1Pnb > Pu, Hence Safe.

file:///C:/Users/GL702VM-EV032T/AppData/Local/Temp/tmp69F9.tmp 20/01/2023